HCW SWIMMING POOL HEAT PUMP  

NO REVERSIBLE 

 

PASHW030 - 50 000 btu 
PASHW045 - 80 000 btu 

 

Installation & Instruction Manual 

 

 

 

 

 

 

 


background image

CONTENTS

   

 

 

 

 

 

 

           

 

 

 1. Preface

 ……………………………………………………………  1 

 2.  Specifications

 ……………………………..………………………  2 

     

2.1 Performance Data of Swimming Pool Heat Pump Unit 2.2 …………………   2 

     2.2 Dimensions for Swimming Pool Heat Pump Unit …………………………...

..  3 

3. Installation and Connection …………………………………………......   4 
    3.1  Installation of system ………………………………………………...  4 
    3.2 Swimming Pool Heat Pump Location ………………………………...  5 
    3.3 How Close your Pool ? ………………………………………………..  5 
    3.4 Swimming Pool Heat Pump Plumbing ……………………………….  6 
    3.5 Swimming Pool Heat Pump Electrical Wiring ……………………….  7 
    3.6 Initial Start-up of the Unit ……………………………………………  7 

 

4. Usage and Operation …………………………………………………….   8 
   4.1  Function of the controller …………………………………………….  8  
   4.2 Usage of the controller  …..…………………………………………...   9 
   4.3 Parameter table ……………………………………………………...... 14 

5. Maintenance and Inspection ………………………………………….. …15 
   5.1  Maintenance  ………………………………………………………… 15 
   5.2  Malfunction table  …………………………………………………… 15 

6. Appendix ………………………………………………………………… 16 

 

     6.1 Appendix   1  …..……………………………………………………  17 

           Appendix   2  …..……………………………………………………  17 

           Appendix   3  .….……………………………………………………  18 

           Appendix   4  …..……………………………………………………. 19 

           Appendix   5  …...…………………………………………………… 20 

           Appendix   6  ………………………………………………………... 21 

 

 

 

 

 

 

 

 


background image

   

1.  PREFACE                                                                

 

 

 

In order to provide our customers with quality, reliability and versatility, this product  
has been made to strict production standards. This manual includes all the necessary 
information about installation, debugging, discharging and maintenance. Please read  
this manual carefully before you open or maintain the unit. The manufacture of this 
product will not be held responsible if someone is injured or the unit is damaged, as a result 
of improper installation, debugging, or unnecessary maintenance. It is vital that  
the instruction within this manual are adhered to at all times. The unit must be installed  
by qualified personnel. 

 

 

The unit can only be repaired by qualified installer centre, personnel or an authorized 
dealer. 

 

 

Maintenance and operation must be carried out according to the recommended time  
and frequency, as started in this manual. 

 

 

Use genuine standard spare parts only. 
Failure to comply with these recommendations will invalidate the warranty. 

 

 

Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature 
constant. For split type unit, The indoor unit can be Discretely hidden or semi-hidden to 
suit a luxury house. 

 

1.

 

Durable 
The heat exchanger is made of PVC & Copper Nickel tube which can withstand 
prolonged exposure to swimming pool water. 

 

2.

 

Installation flexibility 
The unit can be installed outdoors or indoors. 

 

3.

 

Quiet operation 
The unit comprises an efficient rotary/scroll compressor and low-noise fan motor, 
which guaranteed its quiet operation. 

 

4.

 

Advanced controlling 
The unit includes micro-computer controlling, allowing all operation parameters to  
be set. Operation status can be displayed on the LED wire controller. Remote controller 
can be chosen as future option. 
 

 

 

 


background image

 2.  SPECIFICATION                                                              

 

 

2.1 Performance data of Swimming Pool Heat Pump Unit 
       **** REFRIGERANT:  R410A 

 

UNIT 

 

PASHW030-P 

PASHW045-P 

Heating Capacity 

Kw 

14.7 

23.4 

Btu/h 

50 000 

80 000 

Heating Power Input 

kw 

2.1 

3.6 

Running Current 

10.2 

16 

Power Supply 

 

208-230V-/60Hz 

208-230V-60Hz 

Compressor Quantity 

 

Compressor 

 

Rotary 

Scroll 

Fan Number 

 

Fan Power Input 

120 

180 

Fan Rotate Speed 

RPM 

850 

850 

Fan Direction 

 

Horizontal 

Horizontal 

Noise 

dB(A) 

54 

56 

Water Connection 

inch 

1.5 

Water Flow Volume 

gal/min 

30 

36 

Water Pressure Drop (max) 

kPa 

10 

10 

Unit Net Dimensions (L/W/H) 

inch 

See the drawing of the unit 

Unit Ship Dimensions (L/W/H) 

inch 

See package label 

Net Weight 

 

See nameplate 

Shipping Weight 

 

See package label 

 

  

Heating  : Ambient temp. (DB/WB) : 80.6°F / 71.2°F, Inlet water temp: 80°F 

  Heating mode : Ambient temp. Operating envelope  45°F - 95°F 

 

 

 

 

 

 

 

 

 


background image

 

  2.  SPECIFICATION   

    2.2 The dimensions for Swimming Pool Heat Pump Unit 

 

           

PASHW030-P              Unit : inch

 

 

    

 

 

            PASHW045-P              Unit : inch

     

 

 

 

 


background image

3.  INSTALLATION AND CONNECTION

   

     

3.1 Installation illustration 

 

 

 
     Installation items: 
     The factory only provides the main unit and the water unit; the other items in the   
     illustration are necessary spare parts for the water system, that provided by users or   
     installer. 
 
    ATTENTION :   
 
    Please follow these steps when using for the first time: 

1-

 

Open valve and charge water 

2-

 

Make sure that the pump and water-in-pipe have been filled with water 

3-

 

Close the valve and start the unit 

ATTN: It is necessary that the water-in-pipe is higher than the pool surface. 

 

Installation must be performed in accordance with the requirements of NEC and CEC 

        by authorized personnel only. 
 
 

 

 

 

 

 

 
 

 

 


background image

3.  INSTALLATION AND CONNECTION

  

 
3.2 Swimming Pool Heat Pumps Location 
    
      The unit will perform well in any outdoor location provided that the following three   

     

factors are presented: 

 

1.

 

Fresh  -  2. Electricity -  3. Pool filter piping 

 
     The unit may be installed virtually anywhere outdoor. For indoor pools please consult  
     the supplier. Unlike a gas heater, it has no draft or pilot light problem in a windy area. 
 
     DO NOT place the unit in an enclosed area with a limited air volume, where the units   
     discharge air will be re-circulated. 
     DO NOT place the unit to shrubs which can block air inlet. These locations deny the  
     unit of a continuous source of fresh air which reduces it efficiency and may prevent   
     adequate heat delivery. 

 

 

 

   3.3 How Close To Your Pool? 
 
         Normally, the pool heat pump is installed within 7.5 meters of the pool. The longer the  
         distance from the pool, the greater the heat loss from the piping. For the most part, the 
         piping is buried. Therefore, the heat loss is minimal for runs of to 15 meters (15 meters   
         to and from the pump = 30 meters total), unless the ground is wet or the water table is     
         high. A very rough estimate of heat loss per 30 meters is 0.6 kW-hour, (2000 BTU) for  
         every 5˚C difference in temperature between the pool water and the ground surrounding   
         the pipe, which translates to about 3% increase in run time. 
 

 

 

 


background image

    

3.  INSTALLATION AND CONNECTION

 

 
    3.2 Swimming Pool Heat Pumps Plumbing 

 

          The Swimming Pool Heat Pump exclusive rated flow titanium heat exchanger requires   
          no special plumbing arrangements except  bypass (please set the flow rate according to  
          the nameplate). The water pressure drop in less than 10 kPa at max. Flow rate. Since  
          there is no residual heat or flame Temperature, The unit does not need copper heat sink  
          piping. PVC pipe can be run straight into the unit. 

 

         Location : Connect the unit in the pool pump discharge (return) line downstream of all  
         filter and pool pumps, and upstream of any chlorinators, ozonators or chemical pumps. 

 

         Standard model have slip glue fittings which accept 1.5 inch PVC pipe for connection to  
         the pool or spa filtration piping. When the water connector is 1 inch to 1.5 inch you can  
         plumb 1.5 inch PVC piping straight into the unit. 

 

         Give serious consideration to adding a quick coupler fitting at the unit inlet and outlet to  
         allow easy draining od unit for winterizing and to provide easier access should servicing  
         be required. 

 

 

      

 

       Condensation: Since the Heat pump cools down the air about 4-5˚C, water may condense  

       on the fins of the horseshoe shaped evaporator. If the relative humidity is very high, this  
       could be as much as several liters an hour. The water will run down the fins into the  
       basepan and drain out through the barbed plastic condensation drain fitting on the side  
       of the basepan. This fitting is designed to accept ½ inch clear vinyl tubing which can be  
       pushed on by hand and run to suitable drain. It is easy to mistake the condensation for a  
       water leak inside the heat pump.  

        

       NB: A quick way to verify that the water is condensation is to shut off the unit and keep  
       the pool pump running. If the water stops running out the basepan. It is condensation.  
       AN EVEN QUICKER WAY is to TEST THE DRAIN WATER FOR CHLORINE – if there no      
       chlorine present, then it’s condensation 
 

 


background image

3.  INSTALLATION AND CONNECTION

 

 

     

3.5 Swimming Pool Heat Pumps Electrical Wiring

 

 

     

NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit,  

      it simply prevents the flow of electricity to or from the pool water. Grounding the unit is   
      still required to protect you against short circuits inside the unit. Bonding is also required.

  

 

    

The unit has a separate molded-in junction box with a standard electrical conduit nipple  

     already in place. Just remove the screws and the front panel, feed your supply lines in  
     through the conduit nipple and wire-nut the electric supply wires to the three connections  
     already in the junction box (four connections if three phase). To complete electrical   
     hookup, connect Heat Pump by electrical conduit, UF cable or other suitable means as  
     specified (as permitted by local electrical authorities) to a dedicated AC power supply   
     branch circuit equipped with the proper circuit breaker, disconnect or time delay fuse  
     protection.

 

     Disconnect – A disconnect means (circuit breaker, fuse or un-fused switch) should be     
     located within sight of and readily accessible from the unit. This is common practice on  
     commercial and residential air conditioners and heat pumps. It prevents remotely-energi-    
     zing unattended equipment and permits turning off power at the unit while the unit is  
     being serviced. 

 

    3.6 Initial Startup of the Unit 

 

    

NOTE: In order for the unit to heat the pool or spa, the filter pump must be running to  

    circulate water through the heat exchanger.

 

 

    Startup Procedure – After installation is completed, you should follow these steps: 
1.

 

Turn on your filter pump. Check for water leaks and verify flow to and from the pool. 

2.

 

Turn on electrical power supply to the unit, then press the key ON/OFF of wire controller. It 
should start in several seconds. 

3.

 

After running a few minutes make sure the air leaving the top (side) of the unit is cooler 
(Between 5-10˚C) 

4.

 

With the unit operating turn the filter pump off. The unit should also turn of automatically. 

5.

 

Allow the unit and pool pump to run 24 hours per day until desired pool water temperature 
is reached. When the water-in temperature reach setting. The unit just shuts off. The unit 
will now automatically restart (as long as your pool pump is running) when the pool 
temperature drops more than 2˚C bellow set temperature 

  Time Delay – The unit is equipped with a 3 minutes built-in solid state restart delay included  
  to protect control circuit components and to eliminate restart cycling and contactor chatter.   
  This time delay will automatically restart the unit approximately 3 minutes after each control   
  circuit interruption. Even a brief power interruption will activate the solid state 3 minute   
  restart delay and prevent the unit from starting until the 5 minute countdown is completed.  

  Power interruptions during the delay period will have no effect on the 3 minute countdown. 

 
 

 


background image

4.  USAGE  AND OPERATION

 

 

 

4.1 Function of wire controller

 

 

 

 

 

 

Key 

Key Name 

Key function 

 

ON/OFF 

Pressure this key to turn on/off the unit 

MODE 

Mode 

Press this key to change the working mode 

CLOCK 

Timer 

Press this key to set system time 

˚C/˚F 

Choose key 

Press this key to choose the Celsius degree or Fahrenheit degree 

TIMER ON 

TIMER ON 

Press this key to set timer-on 

TIMER OFF 

TIMER OFF 

Press this key to set timer 

 

Up 

Press this key to select the upward option or increase the 
parameter value. 

 

Down 

Press this key to select the downward option or decrease the 
parameter value. 

 
 
 
 
 

 


background image

 

4.  USAGE  AND OPERATION

 

 
4.2    Usage of wire controller 
4.2.1 Turn ON/OFF the unit 

          When the unit is off, press the key  "

"  0.5s to turned on the unit 

          When the unit is on, press the key  "

"  0.5s to show down the unit 

 

 

 

4.2.2 Mode switch 
         You can choose unit mode (The function is only available for heating & cooling unit).   
         In the unit on or off state, you can choose cooling, heating or automatic mode by   
         pressing ‘’MODE’’ button. 

 

Attention : if the unit is for heating only or coling only, the mode switching operation is invalid 

 

 

 

4.2.3 Temperature selection 
          Choose display type of unit temperature, when the unit is on, press mode button ˚C/˚F  
          And choose Celsius degree or Fahrenheit degree freely. 

 


background image

 

 

 

 

4.  USAGE  AND OPERATION

 

 
4.2.4 Setting temperature 
        

In main interface, press ‘’     ‘’  or  ‘’      ‘’ and the current mode target-temprature   

      

flashes, then press ‘’    ‘’ to increase the temp. Value, or press ‘’    ‘’ to decrease it.   

       Press ‘’MODE’’ can save setting parameter and back to the main interface. 

       Press "

" can not save setting parameter but back to the main interface. 

ATTENTION : If there is no opearation fir 5s, system would remember parameter setting and  
                       back to the main interface. 
 

 

 
 
 
 

 


background image

 
 
 
 
 
 
 
 
 
 
 

10 

4.  USAGE  AND OPERATION 

 

 

4.2.5 Clock setting

 

        

In the main interface, press

 

‘’CLOCK’’ twice. Hours start to flashing, and press ‘’     ‘’   

        to increase value or press ‘’      ‘’ to decrease value, and press ‘’CLOCK’’ to setting. 
        At the same time, minute start to flashing, press ‘’     ‘’  to increase value or press  ‘’     ‘’    

       

to decrease value, and press ‘’CLOCK’’ to save setting. 

        Press "

" can not save setting parameter and back to main interface. 

ATTENTION : If there is no operation for 5s system will remember parameter setting and   
                       back to the main interface. 

Hours      Minute 

 


background image

 

 

 

11 

4.  USAGE  AND OPERATION

 

 
4.2.6 Timer  setting 

 

(1) You can set the timer of the unit on     

        In the on or off state, press ‘’TIMER ON’’ to enter timer-on interface.  
        Press ‘’TIMER ON’’  And time-hour-bit flashing. Press ‘’     ‘’  or ‘’      ‘’ to change the   
        hours value. Press ‘’TIMER ON’’ to save hours. At the same time, minutes-bit flashing.   
        Press ‘’     ‘’  or ‘’      ‘’ to change the minute value. Press ‘’TIMER ON’’ to save and exit.  
        At this time, ‘’TIMER ON’’ LED light is on. (The time-off setting is to pressn’’TIMER  

 


background image

        OFF’’, the other operation is the same as timer-on).  

 

        For example :  

 

 

 
 

12 

4.  USAGE  AND OPERATION

 

 
(2) The setting of cancelling the timer 
      If there is no need to set timer on or timer off, the timer setting can be cancelled. At unit   
      on or off state, press ‘’TIMER ON’’  to enter timer-on setting interface, then press  

      "

" to cancel the timer-on, at this timer, the timer-on light turn off.  

      (Press ‘’TIMER OFF’’ to enter timer-off setting interface, then press "

" to cancel   

           the timer-off, at this timer, the timer-off light turn off. 

Hour           Minute 

 

 


background image

 

 

        

4.2.6 Keyboard Lock 

             To avoid mis-operation, please lock the controller after parameter setting. At the main   

             interface, pressing "

" for 5 seconds, when hearing one sound, the keyboard is locked. 

             When the keyboard is locked, pressin "

" for 5 seconds, when hearing one sound, the   

             keyboard lock is open. 
             

NOTE: When the unit is alarming state, the key lock can be removed automaticly.

  

 
 
 
 
 
 
 

13 

4.  USAGE  AND OPERATION

 

  
     4.2.8 Malfunction display 
         There will be malfunction code showing on the controller screen when relative   
         malfunction occurs. You can refer to the malfunction table to find out the failure cause  
         and solution. 

 

         For example: 

 

 


background image

 

 

 
                 

                  

4.3 Parameter table 

 

 

Digit 

meaning 

Range 

Default 

Adjust (yes/no) 

R01 

Return water temp.  

Setting (cooling model) 

 

81˚F 

Adjustable 

R02 

Return water temp.  

Setting (heatin model) 

 

81˚F 

Adjustable 

R03 

Return water temp.  

Setting (auto mode) 

 

81˚F 

Adjustable 

T02 

Inlet water temp. 

 

True testing figure 

T03 

Outlet water temp. 

 

True testing figure 

T04 

Pipe temp. 

 

True testing figure 

T05 

Ambient temp. 

 

True testing figure 

T01 

Evaporator temp. 

 

True testing figure 

 
 
 
 
 
 
 
 

 

 

 

14 

5.  MAINTENANCE AND INSPECTION

 

 
    5.1 Maintenance 

     

 

 

Check the water supply device and the release often. You should avoid the condition of  

no water or air entering into system, as this will influence unit’s. 

 

The area around the unit should be dry, clean and well ventilated. Clean the side heating  

Exchanger regularity to maintain good heat exchange as conserve energy. 

 


background image

 

The operation pressure of the refrigerant system should only be serviced by a certified 

technician. 

 

Check the power supply and cable connection often. Should the unit begin to operate 

abnormally switch it off and contact the qualified technician. 

 

Discharge all water in the water pump and water system, so that freezing of the water  

in the pump or water system does not occur. You should discharge the water at the bottom of 
water pump if the unit will not be used for an extended period of time. You should check the 
unit thoroughly and fill the system with water fully before using it for the first time after a 
prolonged of no usage. 

 

5.2 Trouble Shooting Guide  

 

Malfunction 

LED 

Controller 

Reason 

Resolution 

Water inlet temp. 
Sensor failure 

P01 

The sensor is open or short circuit 

Check or change the sensor 

Water outlet temp.  Sensor failure 

P02 

The sensor is open or short circuit 

Check or change the sensor 

Coil sensor failure 

P05 

The sensor is open or short circuit 

Check or change the sensor 

Ambient sensor falure 

P04 

The sensor is open or short circuit 

Check or change the sensor 

Temp. differencial between water-in 
and water-out is too large 

E06 

Water flow volume not enough, 
water pressure difference is too low 

Check the water flow volume or 
system obstruction 

Anti freezing under cooling mode 

E07 

Outlet water is too low 

Check the water flow volume or outlet 
water temp. sensor 

The first class freezing protection in 
winter 

E19 

Ambient or inlet water temp. is too 
low 

 

The second class freezing protection 
in winter 

E29 

Ambient or inlet water temp. is too 
lower 

 

High pressure protect 

E01 

Gas System pressure is too high 

Check through the high pressure 
switch and the gas system pressure to 
judge wheter the gas loop is blocked 
or the freon is suitable 

Low pressure protect 

E02 

Gas System pressure is too low 

Check through the low pressure 
switch and the gas system pressure to 
judge whether there is leaking or the 
freon is not enough 

Flow switch failure 

E03 

No water/little water in water 
system 

 

3times water-in and water-out temp. 
difference protection in 30 minutes 

E06 

Water flow rate not enough 

Check the water flow rate, or water 
system is jammed or not 

Defrosting 

Defrost Code 

Display 

 

 

Communication failure 

E08 

LED controller and the PCB 
connection failure 

Check the wire connection 

 

 

 

15 

6.  APPENDIX 

 

 
Appendix 1:  Connection of PCB illustration

 

 


background image

 

 

 

 

Connections explanation :  

 

No. 

Symbol 

Meaning 

OUT1 

Compressor of system 1 (220-230VAC) 

OUT2 

Water pump (220-230VAC) 

OUT3 

4way valve (220-230VAC) 

OUT4 

High speed of fan motor (220-230VAC) 

OUT5 

Low speed of fan motor (220-230VAC) 

AC-N 

Neutral wire 

NET GND 12V  Wire controller 

DI01 GND 

On/Off Switch (input) (no use) 

DI02 GND

 

Flow switch (input) (normal close) 

10 

DI03 GND

 

Low pressure protect 

11 

DI04 GND

 

High pressure protect 

12 

DI05 GND

 

No use 

13 

DI06 GND

 

No use 

14 

AI01 GND

 

Suction temp. (Input) 

15 

AI02 GND

 

Water in temp. (input) 

16 

AI03 GND

 

Water out temp. (inlet) 

17 

AI04 GND

 

Temp. Of Coil (input) 

18 

AI05 GND

 

Ambient temp. (input) 

19 

AI06 GND

 

No use 

 

16 

6.  APPENDIX 

 

 
Appendix 2:  Cable specification 

 


background image

 
1. Single phase unit 

MCA 

Phase line 

(AWG) 

Earth line 

(AWG) 

No more than 13A 

16 

16 

13-18A 

14 

14 

18-25A 

12 

12 

25-30A 

10 

10 

30-40A 

40-55A 

55-70A 

 
 
 
2. Recommend circuit breaker to use 
 

UNIT 

BREAKER 

PASHW030-P-JI 

20A 

PASHW045-P-JI 

40A 

 
 
When the unit be installed at outdoor, please use the cable which can against UV. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

17 

6.  APPENDIX 

 

 


background image

 

Appendix 3:  Explosive view of the unit  

MODEL : PASHW030-P 

 

No. 

Code 

Parts name 

  No. 

Code 

Parts name 

 

32012-210246 

Chassis 

 

22 

20000-360005  Water flow switch 

 

32012-210245 

Front panel 

 

23 

2000-2111 

Water-proof box 

 

20000-220188 

Fan protection net 

 

24 

20000-220243  Handle 

 

3500-2701 

Axial fan 

 

25 

95005-310188  LED200 

 

20000-330124 

Axial fan motor 

 

26 

20000-140353  Needle valve 

 

32012-210229 

Fan bracket 

 

27 

20000-260068  Rubber ring 

 

32012-210226 

Top support plate 3 

 

28 

20000-260069  Rubber ring 

 

32012-210247 

Left rear plate 

 

29 

20000-140353  Needle valve 

 

32012-210228 

Electrical box 

 

30 

32012-210248  Right-side panel 

 

10 

20000-360006 

AC Contactor 

 

31 

32012-120033  Titanium heat exchanger   

11 

95005-310145 

HW200 PC 1000 

 

32 

20000-110110  compressor 

 

12 

2000-3502 

Compressor capacitor 

 

33 

2000-3603 

Pressure switch 

 

13 

2000-3501 

Fan capacitor 

 

34 

20000-360059  Pressure switch 

 

14 

20000-370006 

Transformer 

 

35 

2004-1445 

(R410A) Filter 

 

15 

2000-3909 

Two-seat connector 

 

36 

2001-3605 

Pressure switch 

 

16 

2001-3907 

Five-seat connector 

 

 

 

 

 

17 

32012-210244 

Top Cover 

 

 

 

 

 

18 

32012-210225 

Top support plate 2 

 

 

 

 

 

19 

32012-120029 

Fin heat exchanger 

 

 

 

 

 

20 

32012-210227 

Middle separation panel 

 

 

 

 

 

21 

32012-210224 

Top support plate 1 

 

 

 

 

 

 
 

18 

6.  APPENDIX 

 

 


background image

 

Appendix 3:  Explosive view of the unit  

MODEL : PASHW045-P

 

 

No. 

Code 

Parts name 

  No. 

Code 

Parts name 

 

20000-110038 

Compressor 

 

22 

2001-3906 

Three-seat connector 

 

20000-140353 

Needle valve 

 

23 

2000-3510 

Compressor capacitor 

 

3500-1401 

Liquid-gas separator 

 

24 

2000-3524 

Compressor capacitor 

 

2004-1445 

Filter 

 

25 

32009-210118  Cover of electrical box 

 

2000-3603 

Pressure switch 

 

26 

95005-310145  Main controller 

 

2001-3605 

Pressure switch 

 

27 

20000-360007  AC contactor 

 

20000-360059 

Pressure switch 

 

28 

20000-360035  Start Relay 

 

32010-210015 

Chasis 

 

29 

2000-3509 

Fan capacitor 

 

32010-210017 

Front pannel 

-  30 

20000-370006  Transformer 

 

10 

20000-220169 

Fan protection net 

 

31 

32009-210117  Electrical box 

 

11 

20000-270004 

Axial fan 

 

32 

20000-360005  Water flow switch 

 

12 

20000-330143 

Axian fan motor 

 

33 

32010-120012  Titanium heat exchanger   

13 

32009-210204 

Fan bracket 

 

34 

32009-120021  Fin heat exchanger 

 

14 

32010-210018 

Left rear plate 

   

 

 

 

15 

32009-210202 

Support plate 

   

 

 

 

16 

32009-210025 

Support panel 

 

 

 

 

 

17 

32009-210205 

Top cover 

 

 

 

 

 

18 

32009-210023 

Middle separation panel 

 

 

 

 

 

19 

32010-210016 

Right-side panel 

 

 

 

 

 

20 

95005-310188 

Wire controller 

 

 

 

 

 

21 

2001-3909 

Three-seat connector 

 

 

 

 

 

 
 

19 

6.  APPENDIX 

 

 


background image

 

Appendix 5:  Circuit diagram of the unit 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

20 

6.  APPENDIX 

 

PASHW030-P 

 


background image

 

Appendix 6:  Circuit diagram of the unit 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

21 

PASHW045-P