OUTLINE 

 
 

1. Important safety information

………………………

2. Main technical parameters

       

………………………

3. Installation

     

…………………………………………

4. Connecting

 

…………………………………………

5. Control

       

……………………………………………

10 

6. Check

           

……………………………………………

14 

7. Maintenance

………………………………………

14 

8.Troubleshooting

         

…………………………………

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

1.Important safety information 

Carefully read and follow all safety precaution and warnings before attempting to install and use this operator, incorrect 

installation can lead to severe injury. 

 

The  gate  operator  should  be  installed  by  a  qualified  technician;  otherwise,  serious  personal  injury  or  property 

damage may occur. 

 

The  auto-reverse  function  must  be  checked  during  installation  to  ensure  that  the  gate  can  auto-reverse  in  the 

event of obstruction. 

 

This auto-reverse function should be regularly inspected and adjusted, if necessary. 

 

When opening or closing the gate, do not attempt to walk or drive through the gate. 

 

Children should not be allowed to play near or operate automatic gates. 

 

The automatic gate operator must be grounded.

 

 

Install the gate operator on the inside of the property, DO NOT install it on the outside of the property where the 

public has access to it. 

 

Be careful when in close proximity to moving parts where hands or fingers could be pinched. 

 

Do not allow control devices to be placed so that a person can access them by reaching through the gate. 

 

In the event of power failure, an emergency release key allows you to operate the gate manually. 

 

The operator should be switched off before repairing it or opening its cover. 

 

Please erase and reprogram the code after installing the operator. 

 

2. Main technical parameters 

 

 

 

 

 

 

 

 

 

 

3. Installation 

 

The HATO 400 Y rack-driven gate operator operates by forcing a drive rack past a drive gear. The entire configuration 

is shown in Fig.1. The gate operator must be installed on the inside of the gate. 
 

 

Gate preparation 

Be  sure  the  gate  is  properly  installed  and  slides  smoothly  before  installing  the  DKC400Y  sliding  gate  operator.  The 

gate must be plumb, level, and move freely. 

Conduit 

In order to protect the wires, use PVC conduit for wires, conduit must be set into the concrete when it is poured. Wires 

within the conduit shall be located or protected so that no damage can result from contact with any rough or sharp 

part. 

Type 

HATO 400Y 

Power supply

 

AC 220V, 50Hz

 

Motor speed

 

1400 r/min

 

Gate moving speed

 

11m/min (19 teeth)

 

Output torque

 

14N

·

m

 

Limit switch

 

Spring limit switch

 

Noise

 

62dB;

 

Environmental temperature 

-20

º

C~+50

º

C

 

 


background image

 

 

Fig.1 

Concrete pad 

The base unit of the gate operator requires a concrete pad in order to maintain proper stability. The concrete pad 

should be approximately 300mm x 200mm x 200mm deep in order to provide for adequate operation. 

Anchors 

You can use the anchors, bolts, washers and nuts that are provided with the operator. These anchors must be set into 

the concrete when it is poured, or you can use wedge anchors. 

Operator 

In locations where ground freeze is possible, mount the gate operator on installation pad as shown in Fig.2. Check the 

operator and make sure it is lined up with the gate.

 

Conduit

Installation pad

Gate operator

Gear

Nut

Spring washer

Plain washer

Anchor

Bolt

Nut

Spring limit switch

Wires

 

  Fig.2       

 

Installation of rack (see Fig.3) 

 

If  you  have  installed  an  external 

button  switch,  you  must  use  two 

conduits:  one  for  main  power  wire, 

another  one  for  low  voltage  wire 

(button switch). 

 


background image

 

 

Fix the three nuts (in the same package with rack) on the rack element. 

 

Lay the first piece of rack on the gear and weld the first nut on the gate. 

 

Move the gate manually, checking if the rack is resting on the gear, and weld the second and third nut. 

 

Bring another rack element near to the previous one. Move the gate manually and weld the three nuts as the first 

rack, thus proceeding until the gate is fully covered. 

 

When the rack has been installed, to ensure it meshes correctly with the gear. 

 

The space between rack and gear is about 1mm.

 

 

 

Fig.3 

 

Spring limit switch 

 

To ensure safety, it is recommended to install plastic blocks at both ends of the gate to prevent the gate from 

sliding out of the rail. The rail must be installed horizontally. 

 

Install the plastic block as shown in Fig.4 and Fig.5. The spring limit switch and blocks are used to control the 

position of the gate. 

 

Release the gear clutch with the key and push the sliding gate manually to pre-determine the position, fix the 

block to the rack and then tighten the gear clutch with the key. Moving the gate electrically, adjust the block to the 

proper position until the position of the opening and closing meet the requirement. 

 

Block

Gate

Rack

Gear

Guide rail

Spring limit switch

Nut

 

Fig.4 

 

 


background image

 

Rack

Left block

Right block

 

 

Fig.5 

 

 

 

 

CONFORMITY DECLARATION: 

 

Motor Hato 400Y meets the requirements set out in the following provisions: 

It

s in accordance with Machine Directive 2006/42/WE and following modify. 

It

s in accordance with the following directive CE: 

Electromagnetic compatibility Directive EMC 2014/30/UE and following modify. 
Low tension Directive LDV 2014/35/UE and following modify.  
Have been applied the following harmonized norms: 
EN60335-1:2012, EN60335-2-103:2015-3, EN 55014-1:2012, EN 55014-2:2015-06,  
EN 61000-3-2-2014-10, EN 61000-3-3:2013-10 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Controller of Gate 

Drives for 230Vac   

500W Motors 

USER’S MANUAL 

 


background image

 

 

SOFTWARE

 

MARKING 

NOTES 

1.2.0-C-NO 

11:8.2.2/6.1.0 

HEL11C 

Before the installation and first use of the controller read the manual carefully and keep it for future reference.   

According to the Machinery Directive 2006/42/CE, the product must not be put into service until the final 
machinery into which it is to be incorporated or of which it is to be a subassembly has been declared in 
conformity  with  the  provisions  of  directives  and  relevant  regulations  which  the  final  machinery  must 
comply with.     

 
Safety recommendations and precautions: 

  

Before  installing  and  using  the  drive  read  all  safety  warnings  and  rules.  Incorrect  installation  and  failure  to 
observe the standards included in the manual can cause serious accidents.   

 

  The controller can be installed only by qualified personnel with relevant licences.   

  A basic protection against electrostatic discharges (ESD) shall be provided during the installation. 

  Caution  shall  be  exercised  during  the  installation.  The  controller  uses  the  230Vac  voltage  (hazardous  to 

health and life). 

  All works related to the correct functioning of the device (connection, start-up, operation) must be performed 

in  accordance  with  relevant  regulations  concerning  the  use  of  electrical  machines  and  in  line  with  the  OHS 
regulations.   

  Do  not  connect  the  supply  voltage  earlier  than  specified  in  this  manual!  Failure  to  comply  with  this 

recommendation can cause an electric shock.   

  Check the gate condition before starting the installation: the gate should not swing too much, it should move 

easily and smoothly.   

  Before the installation, remove unnecessary ropes and secure the equipment, e.g. locks.   

  Children,  disabled  persons  and mechanical  vehicles  should  not  be  present  in  the  vicinity  of  the  gate during 

the installation.   

  All  fixed  controls  should  be  located  near  the  gate,  but  away  from  the  moving  parts  and  out  of  reach  of 

outsiders.   

  Disconnect the power supply before repairing or removing any part of the gate.   

  Children and mentally disabled persons must not operate the gate by themselves. 

  Motor and applicable force can be done by qualified personnel equipped with gauge force meter.   

  In the controller without encoder input it is necessary to connect gate optical    curtain or other safety elements 

preventing from accidentally crush. 

  Fluorescent lamps cannot be connected to the controller.   

 

The controller can be used only in specified applications.   

 

Failure  to  observe  these  instructions  can  lead  to  serious  injuries  or  destruction  of  the  equipment.  The 
manufacturer will not be liable for losses and disruption in work resulting from non-observance of this installation 
and operation manual. 

 
 

According to relevant regulations concerning the disposal of used equipment by the private 

users  in  the  European  Union,  an  object  bearing  this  symbol 

MUST  NOT

  be  disposed  of 

together  with  regular  wastes.  In  such  case  the  user  is  responsible  for  correct  disposal  by 
delivering the equipment to a specialized outlet or to the manufacturer who will take care of 

the  further  disposal.  Separate  collection  and  recycling  of  used  equipment  facilitates  the 
environmental protection and ensures that disposal is carried out in a manner safe to human 
life  and  the  environment.  This  remark  also  applies  to  spent  batteries,  disposable  and 
rechargeable. 

 


background image

 

Version : 

HEL11C

 

 

 

cooperates with 

Hato’s transmitters operating at a 433.92 MHz frequency and compatible with 

Keeloq protocol. 

 

 

– with encoder input 

 

– lamp control by relay   

 
Table of contents: 

OUTLINE

 ........................................................................................................................................................................................... 2

 

Anchors

 ............................................................................................................................................................................................. 4

 

1. Application and functionality of HEL11C

. ......................................................................................................................... 10

 

2. Installation

 .................................................................................................................................................................................. 10

 

2.1 Limit switches connection .................................................................................................................................... 10 

2.3 Photocell connection ........................................................................................................................................... 10 

2.4 Step-By-Step pushbutton connection .................................................................................................................. 11 

2.5 Capacitor connection ........................................................................................................................................... 11 

2.6 Motor connection ................................................................................................................................................ 11 

2.7 Signalling lamp connection .................................................................................................................................. 11 

2.8 Mains supply connection ..................................................................................................................................... 11 

2.9 Open direction check ........................................................................................................................................... 11 

2.10.1 Motor power adjustment (HEL11C version) ................................................................................................... 11 

2.10.2 Applicable force adjustment -(HEL11C)   ........................................................................................................ 11 

2.11 Optional STOP button connection ..................................................................................................................... 11 

3. 

Settings and programming

 .................................................................................................................................................... 11

 

3.1 Autoclose.............................................................................................................................................................. 11 

3.2 Autoclose time setting ......................................................................................................................................... 12 

3.3 Open only function ............................................................................................................................................... 12 

3.4 Automatic wicket ................................................................................................................................................. 12 

3.5 Signalling lamp ..................................................................................................................................................... 12 

4. 

Transmitters deleting and programming

 ........................................................................................................................... 12

 

4.1 Deleting all transmitters....................................................................................................................................... 12 

4.2 Transmitters programming .................................................................................................................................. 12 

4.3 Remote transmitter programming (not available in HEL11H) ............................................................................. 12 

5. Technical specification:

.......................................................................................................................................................... 14

 

6. Dimension

 .................................................................................................................................................................................. 14

 

7. Controller wiring diagram

 ...................................................................................................................................................... 16

 

 

 

 


background image

1. Application and functionality 

of HEL11C

 

 
The  controller  is  designed  for  gate  drives  with  230Vac 

motors.  A  perfect  choice  for  continuous  operation,  the 
controller  can  be  used  in  community  car  parks,  private 
homes  and  corporate  compounds.    Applied  Microchip 

rolling  code  technology  prevents  from  not  authorized 
entrance.

 

The  controller  cooperates  with  monostable 

pushbutton with Step-By-Step functionality,   
(OPEN-STOP-CLOSE-STOP)  The  control  unit  perform 

following operations: Autoclose, Open only and Automatic 
wicket    The  are  two  available  main  versions.  First  one 
with encoder input, and second one without it.   

  

2. Installation   

  

Install  the  controller  into  drive.  All  dimensions  are  in  the 
Picture  1.    After  correct  installation  continue  with 
electrical connection. 

 
The  manufacturer  will  not  be  liable  for  losses  and 

disruption  in  work  resulting  from  non-observance  of  this 
installation, operation manual and applicable regulations. 
 

2.1 Limit switches connection 

 

At  first  connect  limit  switches  to  the  controller  inputs 
marked as (

16,17,18

). Check the gate condition: the gate 

should  not  swing  too  much,  it  should  move  easily  and 
smoothly  between  limit  positions.  If  necessary  adjust 
placements of magnetic parts. 

16 (OL)

 

open limit,   

17 (CL)

 

 close limit,   

18 (COM)

 

 common, (white wire) 

 
The controller cooperates with Normally Open or Normally 
Closed  limit  switches.  To  change  type  of  limit  switches 
solder  the  ZS  jumper  on  PCB.  With  soldered  jumper   

version marked as NO cooperates with NC type switches 
and version marked as NC cooperates with NO switches. 
                         

 

 

If you have cotroller without encoder input - skip point 2.2. 

   

2.2 Encoder connection 

 
Motor encoder must be connected to the inputs marked as 
"ENCODER" (Pic.2)(

21,22,23,24

).   

Connect the encoder wires to the plug according to wiring 
diagram description. The controller uses encoder impulses 
to  calculate  applicable  force.  Uncorrect  connection  may 

cause unproper operation and hazardous situation to healt 
and life.   
 

21

 -   

─ ─ 

    - encoder signal 

22

 -    + + +    - GND 

23

 -   

─x─     

- GND 

24

 -   

        - supply (+5V) 

 

Enkoder parameters: 717 impulses per second (speed 
1450rpm) 
 

2.3 Photocell connection 

 
Photocell  barrier  is  a  necessary  safety  element  which 

must  be  connected  to  the  controller.  It  increases  safety 
and prevents a gate wing from hitting a car, a person or an 
object 

which  are  within  the  photocells’

  range.  In  the 

controller without encoder input it is necessary to connect 
gate optical    curtain or other safety elements preventing 
from  accidentally  crush.  It  should  be  in  series  with 
photocell.   

12

 

 Photocell supply +24Vdc 

13

 

 Photocell supply GND 

13-14 

Normally Closed contact 

 

Output  (+24V)  current  cannot  exceed  <  450mA.  Make 
sure power consumption of all connected accesorries.       

Example  of  photocell  connection  is  shown  on  the  wiring 
diagram. 

The controller uses the 230Vac voltage and 
it  can  be  installed  only  by  qualified 
personnel with relevant licences   

 

 

 


background image

11 

 

                                                                                                                                                             

Mains  supply  must  be  protected  by  earth 
leakage circuit breaker

 

 

2.4 Step-By-Step pushbutton connection 

 
Connect the SBS pushbutton using 2x 0,5mm

2

 wire which 

parameters are according to regulations: CEI 20-22; CEI 

EN50267-2-1.  Maximum  distance of  connection  depends 
on  selected  wire.  Series  resistance  should  not  exceed 
100ohms.   

Connect  momentary  pushbutton  switch  to  the  inputs 
marked as S1 (

15

) and COM (

18

).   

 

2.5 Capacitor connection 

 

Connect capacitor to the inputs on the left side marked as 

8

 i 

9

.   

 

2.6 Motor connection 

 

 

Connect motor’s wires to the left connector plug according 

to description or wiring diagram: 

11 (COM)

 

 common       

10 (OPEN)

 

open direction 

7 (CLOSE)

 

close direction 

1 (PE)

 

 protective earth PE (yellow-green wire) 

 

2.7 Signalling lamp connection   

 

Connect signalling lamp (230Vac) to the inputs on the left 
side marked as 

5 (neutral 

 blue wire)

 and 

6 (phase 

 

brown  wire). 

Lamp  power  cannot  exceed  15W/230V. 

When  used  lamp  with  built-in  flashing  module  before 
installation switch off the flashing function in the controller 
(according to 3.5 point).           

 

2.8 Mains supply connection 

 

Mains  connection  should  be  applied  at  the  end  of 

installation. Connect mains wires to the inputs on the left 
side marked as: 
2 (PE) 

 protective ground (yellow-green wire) 

3(L) 

 phase wire (brown wire) 

4 (N) 

 neutral wire (blue wire) 

 

Before  first  using  check  the  correct    power  supply, 

ground  protection  and  wire  connections.  Wires 
should  be  as  short  as  possible.  Keep  control  wires 
away from high current wires. Avoid wires loop. 
 

2.9 Open direction check 

 

Set  the  gate  manually  in  the  middle  position.  The  first 

command after powering up is “open”

. Press the SBS or 

programmed  transmitter  button.  If  drive  works  in  closing 

direction stop the motor, switch off the power supply and 

switch  motor’s  leads  connected  to  the  inputs

  OPEN(

10

and CLOSE(

7

). 

 
If  the  drive  operates  properly  check  functionality  of  all 
connected accessories. In case of problems check wiring 
connection  and  adjust  motor  force  or  applicable  force 

setting. 
 

 

2.10.1 

Motor 

power 

adjustment 

(HEL11C 

version) ?? 

 

Fitted  on  the  control  unit  “P”  potentiometer  adjusts 

maximum  motor  power.  Take  great  care  when  adjusting 
the  power  as  this  may  affect  the  level  of  safety  of  the 
automatic  system. 

Measure  the  force  applied  to  the 

gate and compare it with regulatory values. 

 

2.10.2 Applicable force adjustment -(HEL11C) 

 

The  controller  uses  encoder  impulses  to  calculate 
applicable  force.  To  adjust  the  sensivity  of  the  controller 
use  the 

“P”  potentiome

ter.  In  minus  direction  sensitivity 

decreases, in plus direction sensitivity increases.   

Adjustment  must  be  carried  out  according  to 
applicable regulations.   

 
 
 
 

2.11 Optional STOP button connection   

Connect  external  normally  closed  switch  according  to 
wiring diagram. 

 

3. 

Settings and programming

 

 

 

3.1 Autoclose 

 

In the autoclose operation mode, an opening manoeuvre 

is  followed  by  a  pause  and  then  an  automatic  closing 
manoeuvre. The closing time is determined by the delay in 
turning  off  the  light.  It  is  activated  when  the  OPT1 
(DIPSWITCH)  micro-switch  is  put  to  ON.  When  the 

Auto-close  function  is  active,  the  principle  of  light 
operation is different: the light is slowly flashing when the 
gate is opening, the light is on when the gate stays open, 

and      is  flashing  during  automatic  closing.  When  the 
gate  stops,  the  light  is  off.  The  Auto-close  function 

Disconnect  the  power  supply  before  checking 
wire connection.

   

 

The controller uses the 230Vac voltage and 

it  can  be  installed  only  by  qualified 
personnel with relevant licences   

 

 

 


background image

12 

 

necessitates photocells to ensure user safety (to prevent 
gate from closing when an obstacle is within its range!). in 

addition, the photocells will reduce the opening time. The 
controller  will  detect  the  passage  of  a  vehicle  and  will 
close  the  gate  after  5  seconds.  When  the  Auto-close 

function  is  active,  all  programming  procedures  can  be 
performed only when the gate is stopped after closing. 
 

3.2 Autoclose time setting 

 
To program the controller use the LEARN button and the 
LED on the controller board. Press the LEARN button less 

than 3s, the LED will light up. Then, by pressing the same 
button  you  can  set  the  delay  time.  One  keystroke 
corresponds  to  15  seconds,  (e.g.  4  keystrokes  mean  1 

minute; the LED dims at each keystroke). When you have 
finished  programming,  the  processor  will  automatically 
save the settings after 3s, flash the LED three times and 

return to normal operation. 
 
Example of autoclose time setting shows Tab1.1 
 

3.3 Open only function 

   

 

Open-only  function  facilitates  communication 

through entry-exit and guarantees that a third party will not 
close  or  stop  the  gate  in  the  least  opportune  moment. 
Photocells are necessary for safety. It works only with the 

Auto-close function and is activated by putting the  OPT1 
and  OPT2  micro-switches  to  ON.  A  command  from  the 
remote  or  from  manual  control  will  tell  the  controller  to 

open  the  gate  in  each  case,  and  then  the  gate  will  be 
closed by the Auto-close function.   
 

3.4 Automatic wicket 

 

It is activated when the OPT3 (DIPSWITCH) micro-switch 
is  put  to  ON.  In  the  automatic  wicket  operation  mode, 

when the controller will detect the passage of a vehicle or 
person  (photocell)  during  opening  the  gate  will  stop.  To 
c

lose the gate push the SBS or programmed transmitter’s 

button.  When  autoclose  function  is  also  activated  when 
the  controller  will  detect  passage  the  gate  will  stop  and 
after 5s will close.   
 

3.5 Signalling lamp 

 

It  can  work  in  two  modes.  In  the  first  mode,  as  warning 

signals when the gate is moving. In the second one, as an 
auxiliary lighting of a vehicle or garage with delayed off. In 
the second mode    the lamp is on when gate is moving. 

To  switch  off  second  mode  put  the  OPT1  (DIPSWITCH) 
micro-switch to OFF. Press the LEARN button less than 3s, 
the LED will light up.    Wait 3s, the controller will flash the 

LED tree times and return to normal operation. 

4. 

Transmitters deleting and 

programming 

 

 

4.1 Deleting all transmitters 

 

Press the LEARN button and hold,  the LED will light up, 
go out  and  then  it  will  start  to flash.  Release the  button. 
The deleting procedure is completed. We recommend that 

this procedure is performed right after installation.   
 

4.2 Transmitters programming 

 

 

 

You can program up to  40 remot

e controls with Keeloq’s 

rolling  code.  Each  remote  must  be  programmed 

separately. Press LEARN and hold until the LED lights up 
and  goes  out.  Release  the  button.  Now  you  have  10 
seconds to press a selected button in the remote control. 
When  the  LED  flashes  three  times,  the  learning process 

has been completed successfully. If you wish to program 
more transmitters, after three LED flashes you have next 
10 seconds to program the second remote, etc. A single 

LED  flash  means  that  the  learning  process  is  finished. 
When you have programmed 40 remotes, the memory is 
full and the LED will flash only two times and will return to 

the  normal  operation.  If  the  memory  is  full,  check  if  you 
really use 40 remotes. If you use fewer than 40 remotes, 
clear  the  memory  and  reprogram  all  remotes,  and  when 
you use more than 40 remotes use an additional module 

eL3 which will increase the number of transmitters to 64. 
When the learning error occurs, repeat the programming 
and if this does not help either use another remote in good 

working  order.  If  you  still  fail,  contact  the  authorized 
service. 
 

4.3 Remote transmitter programming 

 

 

 

 

It  is  possible  to  program  new  transmitter  using 

four-channel  earlier  programmed  transmitter.  The  gate 

must  be  fully  open.  Push  the  C  and  D  buttons  of  the 
programmed  transmitter  for  5s.  The  signalling  lamp  will 
light  up.  Now  you  have  5  seconds  to  press  a  selected 

button  in  the  new  remote  controller.  When  the  lamp 
flashes  three  times,  the  learning  process  has  been 
completed successfully. A single LED flash means that the 

learning process is finished.     
 
 
 

 
 
 

 
 
 

 


background image

13 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

Tab.1.1. Autoclose time setting   

(e.g.) 

1.    Press the LEARN button. 

 

The LED will light up. Release the button.   

  
  
                       

2.  Then,  by  pressing  the  same  button  you  can  set  the  delay  time.  One  keystroke 

corresponds to 15 seconds, (e.g. 4 keystrokes mean 1 minute; the LED dims at 

each keystroke).

 

  

  
                             

4x 

3.    Wait 3s, the controller flash the LED three times and return to normal operation. 

  
  

3s                                       
3x 

Tab.1.2 Deleting all transmitters   

 

1. 

 

Press the LEARN button and hold, the LED will light up, go out and then it will start 

to flash. We recommend that this procedure is performed right after installation. 

  
  
                                                         
                                                               

5x 

2.    Release the button. The deleting procedure is completed.   

  
  
                            

Tab.1.3 Tranmistters programming 

 

1.    Press LEARN and hold until the LED lights up and goes out. Release the button. 

  

  
                       

2.    Now you have 10 seconds to press a selected button in the remote control. When 
the LED flashes three times, the learning process has been completed successfully. 

  
  

                             10s   

3.    When  the  LED  flashes  three  times,  the  learning  process  has  been  completed 
successfully.    A single LED flash means that the learning process is finished. 

  
  
    3x                  10s               

1x 

   
LEAR
N

 

   
LEAR
N

 

   
LEAR
N

 

   
SW1

 

   
SW1

 

 

 

 


background image

14 

 

 

 

5. Technical specification: 

 

Power supply:

   

 

 

AC 230V, 50Hz 

Curren consumption in standby:

 

< 25mA AC 

Powe consumption in standby:

 

< 10 W 

Transmitters range:

     

 

<200m   

Frequency:

 

 

 

 

433,92MHz 

Transmitters type:   

 

Version 

 

 

 

 

HATO Keeloq   

Transmitters memory:

   

 

40 pcs 

Autoclose max time:

     

 

5s - 10min 

Operation max time:

     

 

120 sec. 

Operating temperature:

   

 

-

20ºC +70ºC

 

Fuse type: 

   

 

 

5A/230V, ø5x20

 

 

6. Dimension

 


background image

 

 

 


background image

HATO 400Y SLIDING GATE OPERATOR USER

’S MANUAL 

16

 

7. Controller wiring diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Picture 2 
 

 


background image

HATO 400Y SLIDING GATE OPERATOR USER

’S MANUAL 

17

 

DISTRIBUTOR/SALESMAN

 

                                                       
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

Hato Polska S.C 

Tomas

z Słodkowski –

 Harmeet Singh 

ul. Tunelowa 57 

40-676 Katowice 

POLAND 

Warehouse/sales/service 

ul. Żeromskiego 1

 

41-205 Sosnowiec 

tel. 032/ 785-25-42 

www.hato.com.pl