PDF User Manual

  1. Home
  2. Manuals
  3. Gentec-EO Uno User Manual

Gentec-EO Uno User Manual

Made by: Gentec-EO
Type: User Manual
Category: Monitor
Pages: 14
Size: 0.75 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

WARRANTY 

The  Gentec-EO  UNO  Single  Channel  Laser  Power  Meter comes with a one-year warranty (from date of 
shipment)  against  material  and/or  workmanship  defects,  when  used  under  normal  operating  conditions. 
The warranty does not cover damages related to battery leakage or misuse.  

Gentec-EO Inc. will repair or replace, optionally, any UNO that proves to be defective during the warranty 
period, except in the case of product misuse. 

Any attempt by an unauthorized person to alter or repair the product voids the warranty. 

The manufacturer is not liable for consequential damages of any kind. 

Customers must fill in and mail the warranty card in order to activate the warranty. 

In case of malfunction, contact your local Gentec-EO distributor or nearest Gentec-EO Inc. office to obtain 
a return authorization number. The material should be returned to: 

 

 

 

Gentec Electro-Optics, Inc. 

445, St-Jean-Baptiste, Suite 160 

Québec, QC 

Canada   G2E 5N7 

 

Tel:  (418)  651-8003 

Fax:  (418)  651-1174 

e-mail: info@gentec-eo.com 

 
 

Website: www.gentec-eo.com 

 

CLAIMS 

To obtain warranty service, contact your nearest Gentec-EO agent or send the product, with a description 
of  the  problem,  prepaid  shipping  and  insurance,  to  the  nearest  Gentec-EO  agent.  Gentec-EO  Inc. 
assumes no risk for damage in transit.  Gentec-EO Inc. will, at its option, repair or replace the defective 
product free of charge or refund your purchase price.  However, if Gentec-EO Inc. deems that the failure 
is caused by misuse, alterations, accident or abnormal condition of operation or handling, you will be billed 
for the repair and the repaired product will be returned to you (repetitive, see above). 

 

 


background image

UNO User’s Manual                                             Revision – 6

 

  1

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

WARRANTY 

The Gentec-EO   UNO  Single  Channel Laser Power, Energy and Power/Energy Meter carries a one-year 
warranty (from date of shipment) against material and/or workmanship defects, when used under normal 
operating conditions. The warranty does not cover damages related to battery leakage or misuse.  

Gentec-EO Inc. will repair or replace, optionally, any UNO that proves to be defective during the warranty 
period, except in the case of product misuse. 

Any attempt by an unauthorized person to alter or repair the product voids the warranty. 

The manufacturer is not liable for consequential damages of any kind. 

Customers must fill in and mail the warranty card in order to activate the warranty. 

In case of malfunction, contact your local Gentec-EO distributor or nearest Gentec-EO Inc. office to obtain 
a return authorization number. The material should be returned to: 

 

 

 

Gentec Electro-Optics, Inc. 

445, St-Jean-Baptiste, Suite 160 

Québec, QC 

Canada   G2E 5N7 

 

Tel:  (418)  651-8003 

Fax:  (418)  651-1174 

e-mail: service@gentec-eo.com 

 
 
 

Website: www.gentec-eo.com 

 

CLAIMS 

To obtain warranty service, contact your nearest Gentec-EO agent or send the product, with a description 
of  the  problem,  transportation  and  insurance  prepaid,  to  the  nearest  Gentec-EO  agent.  Gentec-EO  Inc. 
assumes  no  risk  for  the  damage  in  transit.    Gentec-EO  Inc.  will,  at  its  option,  repair  or  replace  the 
defective  product  free  of  charge  or  refund your purchase price.  However, if Gentec-EO Inc. determines 
that the failure is caused by misuse, alterations, accident or abnormal condition of operation or handling, 
you will be billed for the repair and the repaired product will be returned to you, transportation prepaid. 

 

 

 

 

 

 

 

 


background image

UNO User’s Manual                                             Revision – 6

 

  2

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

SAFETY INFORMATION 

Do  not  use  the  UNO  if  the  device  or  the  detector  looks  damaged,  or  if  you  suspect  that  the UNO is not 
operating properly. 

Appropriate  installation  must  be  done  for  water-cooled  and  fan-cooled  detectors.    Refer  to  the  specific 
instructions  for  more  information.    The  user  must  wait  for  a  while  before  handling  these  detectors  after 
power is applied. Surfaces of the detectors get very hot and there is a risk of injury if they are not allowed 
to cool down. 

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital 
device,  pursuant  to  part  15  of  the  FCC  Rules.    These  limits  are  designed  to  provide 
reasonable  protection  against  harmful  interference  in  a  residential  installation.    This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications.    However,  there  is  no  guarantee  that  interference  will  not  occur  in  a 
particular  installation.    If  this  equipment  does  cause  harmful  interference  to  radio  or 
television reception, which can be determined by turning the equipment off and on, it is 
suggested to try to correct the interference by taking one or more of the following steps: 

•  Reorient or relocate the receiving antenna. 
•  Increase the distance between the equipment and receiver. 
•  Connect the equipment to an outlet that is on a different circuit than the receiver. 
•  Consult the dealer or an experienced radio/TV technician for help. 

 

Caution: 

Changes or modifications not expressly approved in writing by Gentec-EO Inc. may void 
the user’s authority to operate this equipment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

UNO User’s Manual                                             Revision – 6

 

  3

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

TABLE OF CONTENTS 
 

1.1

 

I

NTRODUCTION

 ............................................................................................................................................... 4

 

1.2

 

S

PECIFICATIONS

 .............................................................................................................................................. 5

 

1.3

 

F

RONT 

P

ANEL 

D

ESCRIPTION

 ........................................................................................................................... 6

 

1.4

 

C

ONNECTOR 

D

ESCRIPTION

 ............................................................................................................................. 7

 

2.1

 

P

OWER MEASUREMENT PROCEDURE

 ............................................................................................................... 7

 

2.2

 

D

ISPLAY DESCRIPTION

 .................................................................................................................................... 9

 

3.1

 

B

ATTERY SELECTION

 .................................................................................................................................... 10

 

3.2

 

B

ATTERY INSTALLATION

 ............................................................................................................................... 10

 

3.3

 

B

ATTERY REMOVAL

 ...................................................................................................................................... 10

 

4-

 

 

DECLARATION

 

OF

 

CONFORMITY ......................................................... E

RREUR

 !

 

S

IGNET NON DEFINI

.

 

4.1

 

R

ECYCLING AND SEPARATION PROCEDURE

 ................................................................................................... 12

 

4.2

 

S

EPARATION

 ................................................................................................................................................. 12

 

4.3

 

D

ISMANTLING PROCEDURE

 ........................................................................................................................... 12

 

 

LIST OF ILLUSTRATIONS 

 

F

IG

.

 

1-1

  

UNO

 

F

RONT 

P

ANEL

 .......................................................................................................................... 6

 

F

IG

.

 

1-2

  

UNO

 

C

ONNECTORS

 .......................................................................................................................... 7

 

F

IG

.

 

1-3

  

UNO

 

LCD

 

D

ISPLAY

 ........................................................................................................................... 9

 

 

 


background image

UNO User’s Manual                                             Revision – 6

 

  4

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

THE UNO SINGLE CHANNEL LASER POWER METER 

 

 

 

1.1  Introduction 

To obtain full performance from the UNO, we recommend that you read this manual carefully. 

The  UNO  is  a  large  display  laser  power  monitor  that  features  outstanding  efficiency,  ease  of  use  and 
battery life. 

Unpacking 

Each Gentec-EO UNO is thoroughly tested and calibrated prior to shipment. 

Visually  inspect  every  UNO  unit  after  removing  it  from  the  shipping  containers.  If  you  see  any  damage, 
retain  all  packaging materials and shipping receipts. Any damage claim should be made promptly to the 
shipping company. Notify the nearest Gentec-EO representative concerning the claim, so that any repair 
or replacement can be arranged as soon as possible.  

 


background image

UNO User’s Manual                                             Revision – 6

 

  5

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

 

1.2  Specifications 

The following specifications are based on a one-year calibration cycle, an operating temperature of 18 to 
28ºC (64 to 82ºF) and a relative humidity not exceeding 80%. 

Table 1-1 List of Specifications 

 

UNO POWER METER SPECIFICATIONS 

Power Range 

10 nW to 10 kW 

Power Scales  

(photodetector) 

autoscale 

Power Scales  

(thermal head) 

single wide range scale 

Digital Resolution 
(photodetector)  

1 pW 

Digital Resolution 
(thermal detector) 

1 mW 

Digital Resolution 
(XLP-12 detector) 

1 µW 

Monitor Accuracy 

±1 % 

5 µV 

Response Time 
(accelerated)

1

 

1 sec 

Sampling Frequency 

16.7 Hz 

Digital Display 

76 x 57 mm LCD 

Display Rate 

2 Hz 

Dimensions 

210 mm(W) x 122 mm (H) x 44 mm (D) 

Weight (including 
batteries) 

0.47 kg 

Batteries (included) 

4 Alkaline AA batteries 

Battery life (with 
thermal detector) 

670 hours (estimated) 

External Power Supply 
(not included) 

Input: 100/240 VAC 50-60 Hz, Output 9 VDC 1.66 A 

 

                                                      

1

 Varies with detector head. 

 


background image

UNO User’s Manual                                             Revision – 6

 

  6

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

 

Fig. 1-1  UNO Front Panel 

1.3  Front Panel Description 

1- 

 control key. 

 

UNO on and off. 

2- 

Zero / dBm control key. 

 

Cancels  electronic  offset,  detector  offset  and  ambient  light  on  the  detector.    This  key 
should be pressed before taking measurements.  Refer to p.7 adjusting the zero (steps 8 
and  9).  The  hidden  dBm  function  is  available  by  pressing  more  than  2  seconds  on  the 
Zero  control  key.The  Uno  will  convert  the  displayed  number  in  dBm  (dB  referenced  to 
1mW) 

and will display “dBm” unit. To get back to the previous display in Watt, press again 

more than 2 seconds on the Zero control key. 

3- 

Att control key. 

 

Photodetectors can be calibrated with and without attenuator.  This key allows the user to 
select  the  proper  configuration  and  wavelength.    The  ATT  LCD  annunciate  indicates 
whether the attenuator sensitivity is activated. 

4- 

Save λ control key. 

 

After selecting the proper wavelength using the 

λ up and λ down control keys, pressing 

the 

Save λ control key stores the wavelength in non-volatile memory and returns to the 

measurements with the corresponding sensitivity. 

5- 

λ up and λ down control keys. 

 

Allows the user to select the appropriate wavelength. 

6- 

 

Fast and Slow control keys. 

These  keys  are  only  useful  with  thermal  detector  heads.    The  fast  mode  enables 
anticipation,  which  shortens  the  natural  response  time  of  the  detector.    The  slow  mode 
disables anticipation.  By default, the monitor is in Fast mode.  This setting is not stored in 
non-volatile memory and therefore returns to Fast mode on every power-up. 

 


background image

UNO User’s Manual                                             Revision – 6

 

  7

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

 

Fig. 1-2  UNO Connectors 

1.4  Connector Description 

1- 

EXTERNAL POWER SUPPLY INPUT JACK. 

 

Input  voltage  required:  9  VDC/100  mA.    The  external  power  supply  does  not  charge  the 
batteries; it allows the use of the monitor without batteries, with dead batteries or simply to 
avoid discharging the batteries inside the monitor. 

 

CAUTION 

Permanent damage to the optical meter may occur if an external 
power supply other than the Gentec-EO P/N 200960A is used. 
Please call Gentec-EO or your local distributor if extra power 
supplies are needed. 

 

2- 

PROBE INPUT JACK. 

 

The UNO uses a DB-15 female connector to mate with the detector heads (probes). 

The  UNO  works  with  all  Gentec-EO  power  detectors  currently  sold.    It  automatically 
recognizes  every  power  detector  head,  which  ensures  accurate  auto-calibration.    More 
importantly, it can take advantage of our Personal wavelength correction

™.  It reads the 

memory in the Smart Interface connector to provide a wavelength correction that is based 
on spectral data measured from that specific detector. 

 

Getting Started 

 

 

 

 

This section contains important information concerning the installation and operation of the UNO.  The 
UNO is delivered ready to use.  Just install the 4 AA batteries, insert a detector head in the Probe Input 
Jack (#2 in Figure 1-2) and press the I/O key.  

2.1  Power measurement procedure 

1-  Install the power detector on its optical stand. 

2-  First, slide the connector latch to the right to unlock the connector. 

 


background image

UNO User’s Manual                                             Revision – 6

 

  8

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

3-  Turn  the  UNO  off  and  connect  a  power  detector  head  to  the  UNO  using  the  PROBE  INPUT 

JACK (see Fig. 1-2).  It is recommended to turn the UNO off before connecting a new head in 
order to prevent any loss of information from the detector head

’s EEPROM. 

4-  Slide the latch to the left to lock the connector into place. 

5-  Switch the UNO ON using the I/O key.  The UNO displays the current wavelength for a moment 

before  displaying  measurements.    If  this  wavelength  is  not  the  wavelength  of  the  laser,  go  to 
step 6, otherwise proceed to step 7. 

6-  Select the proper wavelength using the 

λ up and λ down control keys. Then press the Save λ 

control  key  to  store  the  wavelength  in  non-volatile  memory  and  return  to  the  measurement 
mode. 

Adjusting the zero (steps 7 to 11) 

7- 

Remove the detector’s protective cover. 

Put  the  detector  into  the  laser  beam  path.    The  entire  laser  beam  must  be  within  the  sensor 
aperture.    Do  not  exceed  maximum  specified  densities,  energies  or  powers.    For  the  most 
accurate measurement, spread the beam across 60% to 80% of the sensor area.  Leave it there 
until the detector has reached its equilibrium temperature. 

8- 

Block off laser radiation to the detector.  

The power read by the UNO when no laser beam is incident on the detector may not be exactly 
zero.    This  is  because  the  detector  is  not  thermally  stabilized  OR there was a heat source in 
the detector’s field of view when you turned on the UNO, OR from the internal electronic offset 
of the UNO. 

9- 

To reset the zero, wait until the reading has stabilized and press the Zero button on the front 
panel.  The UNO will display “ZEro“ for a moment and then return to the normal measurement.  
You  are now ready to make an accurate measurement.  Pressing the  Zero button  again will 
not undo the zero; it will re-do it. 

10-  When you select  ATT  you must enter a wavelength and then press 

Save λ to exit. 

 

11-  Apply the laser beam to the detector.  The laser must be CW for photodetectors. 

 

Notes: 

• 

Refer to the specific power detector documentation for complete installation and operating 
instructions. 

• 

The power detectors are thermal sensors sensitive to temperature variations. 

For high-precision measurements, it is recommended to:  

• 

Allow the power detector’s temperature to stabilize before zeroing the UNO.  

• 

Do not touch the detector itself when handling the power detector.  Touch only the stand. 

• 

Avoid forced airflow or drafts around the detector. 

 


background image

UNO User’s Manual                                             Revision – 6

 

  9

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

 

2.2  Display description 

 

 

Fig. 1-3  UNO LCD Display 

The  LCD  provides  measurement  information,  wavelength  information,  attenuator  selection  and  other 
useful messages. 

When  the  batteries  are  discharged  enough  to  compromise  the  measurement,  the  UNO  displays  “LO” 
instead of the measurement.  Refer to the battery maintenance section to replace the batteries. 

The  ATT  field  indicates  if  the  detector sensitivity used takes into account the presence of the attenuator 
that the detector was calibrated with. 

Error messages can also be displayed: 

E-05 indicates that no detector is present on power-up. 

E-07  appears  after  pressing  the  ATT  control  key  with  a  detector  that  does  not  have  attenuator 
calibration.  The message disappears a few seconds after pressing the control key. 

E-08  indicates  that  the  detector  is  not  supported  or  that  the  detector  calibration  EEPROM  is 
corrupted.  It can also appear if the DB15 is poorly secured or is worn out. 

E-09  appears  after  pressing  the  FAST  or  SLOW  control  key  with  a  detector  that  does  not  have 
anticipation (photodetectors).  The message disappears a few seconds after pressing the control 
key. 

 

Any other error message indicates a malfunction and should be reported. 

 


background image

UNO User’s Manual                                             Revision – 6

 

  10

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

 

BATTERIES

 

 

 

3.1  Battery selection 

To avoid leakage and poor autonomy, it is highly recommended that only good quality, new and identical 
alkaline  batteries  be  put  into  the  UNO.    Good  quality  rechargeable  batteries  can  also  be  used  with  the 
UNO and recharged with an external charger. 

The batteries need to be replaced if the UNO displays “LO” on its digital display or if it does not power-up 
when the I/O control key is pressed. 

3.2  Battery installation 

- Put the UNO face down on a flat surface. 

- Lift the kickstand. 

- Open and remove the battery door. 

- Insert one battery in the nylon strap (to ease removal) and insert it at one extremity of the UNO battery 
compartment  with  the  right  polarity.    To  avoid  intermittent  contact  and  involuntary  disconnection,  firmly 
insert the batteries. Insert the other batteries over the nylon strap with the right polarity so that pulling on 
the strap will pull every battery out of the UNO. 

       

       

 

- Put the battery door back in place. 

3.3  Battery removal 

- Put the UNO face down on a flat surface. 

- Lift the kickstand. 

- Open and remove the battery door. 

- Hold down the UNO and slowly pull on the nylon strap to remove the batteries.  Do not use a pointed tool 
to remove the batteries, since that could puncture them.  The batteries need a firm pull to be removed in 
order to have a reliable contact. 

 

 


background image

UNO User’s Manual                                             Revision – 6

 

  11

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

  

DECLARATION OF CONFORMITY 

Application of Council Directive(s):  2004/108/EC 

 EMC Directive 

 

 

 

 

 

 

 

 

Manufacturer’s Name: 

 

 

Gentec Electro Optics, Inc. 

 

Manufacturer’s Address:   

 

445 St-Jean Baptiste, suite 160 
Québec (Québec), Canada   G2E 5N7 

 
 

European Representative’s Name:   

Laser Components S.A.S. 

 

Representative’s Address:   

 

45 bis Route des Gardes 
92190 Meudon (France) 

 

Type of Equipment: 

 

 

Laser Power/Energy Meter 

 

Model No.: 

 

 

 

UNO 

 

Year of test & manufacture: 

 

2011 

Standard(s) to which Conformity is declared: 
EN 61326-1: 2006 Emission generic standard  
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

I, the undersigned, hereby declare that the equipment specified above 

conforms to the above Directive(s) and Standard(s). 

 
 

 

Place: 

 Québec (Québec)  

 

 

 

Date : 

  May 4, 2011 

 

 

 

  

 

 

 

 

 

 

                                                         

 

  (President) 

Standard 

Description 

Performance 
Criteria 

CISPR11 :2009 
A1 :2010 

Industrial,  scientific  and  medical  equipment 

–  Radio-frequency 

disturbance characteristics 

– Limits and methods of measurement 

Class A 

EN 61000-4-2 2009 
 

Electromagnetic  compatibility  (EMC) 

–  Part  4-2:  Testing  and 

measurement techniques- Electrostatic discharge. 

Class B 

EN  61000-4-3  2006+ 
A2:2010 

Electromagnetic  compatibility  (EMC) 

–  Part  4-3:  Testing  and 

measurement 

techniques- 

Radiated, 

Radio 

Frequency, 

electromagnetic field  immunity test 

Class A 

EN61000-4-4 
2004+A1:2010 

 

Electromagnetic  compatibility  (EMC) 

–  Part  4-4:  Testing  and 

measurement  techniques-  Electrical  fast  transient/burst  immunity 
test. 

Class B 

EN 61000-4-5 2006

 

Electromagnetic  compatibility  (EMC) 

–  Part  4-5:  Testing  and 

measurement techniques- Surge immunity test. 

Class B 

EN 61000-4-6 2009 

 

Electromagnetic  compatibility  (EMC) 

–  Part  4-6:  Testing  and 

measurements 

techniques- 

Immunity 

to 

conducted 

Radio 

Frequency. 

Class A 

EN 61000-4-11 

2004

 

Electromagnetic  compatibility  (EMC) 

–  Part  4-11:  Testing  and 

measurement  techniques-  Voltage  dips,  short  interruptions  and 
voltage variations immunity tests 

Class B 
Class B 
Class C 
Class C 

EN 61000-3-2:2006  
+A1:2009

 

Electromagnetic  compatibility  (EMC)  -  Part  3-2:  Limits  -  Limits  for 
harmonic  current  emissions  (equipment  input  current  <=  16  A  per 
phase) 

Class A 

 


background image

UNO User’s Manual                                             Revision – 6

 

  12

 

 Gentec Electro 

– Optics, Inc.  All rights reserved                                                            

4  APPENDIX 

 

4.1  Recycling and separation procedure 

This  section  is  used  by  the  recycling  center  when  the  monitor  reaches  its  end  of  life.    Breaking  the 
calibration seal or opening the monitor will void the UNO warranty.  

The complete Monitor contains 

1 Monitor 

4 AA Alkaline Batteries 

1 Instruction manual 

1 Calibration certificate 

4.2  Separation 

Paper : manual and certificate. 

Plastic: stand, connector plate, battery door, monitor enclosure, keypad. 

Wires. 

AA batteries: inside battery compartment. 

Metal battery clips. 

Printed circuit board: inside the monitor featuring a liquid crystal display less than 100 cm

2

4.3  Dismantling procedure 

- Remove batteries. 

- Remove the posts on each side of the DB15 connector using pliers. 

- Open monitor by removing the Phillips head screws in the 4 corners. 

- Cut the wires on the PCB side and battery clips side with cutters. 

- Remove battery clips with pliers. 

 

 

 


background image