GENIUS CLEAR WATER SYSTEMS 

Featuring WaterShield

®

 products for clean and safe water 

Installation manual 

& guidelines

Issue 

 


background image

Issue 1, november 2014 

G E N I U S   C L E A R W A T E R   S Y S T E M S  

Installation manual & guidelines 

 Genius Clear Water Systems 

13115 – 42 Street NW 

Edmonton, Alberta, Canada T5A 2V3 

Phone: 1 (780) 475-7551 

 

www.geniusclearwater.com

 


background image

 

 2 

Technical data 

Watershield Ceramic filters 

Max operating pressure: 

10 bar / 145 PSI 

Minimum operating pressure: 

1.5 bar / 22 PSI 

Max. capacity

*

 33,000 

liters

** 

/ 8,700 gallon

**

 

Max. operating temperature: 

100 ºC / 212 ºF 

Connection: 

(BSP) G 1/2" external thread 

* Maximum capacity can vary depending of initial water quality. 
** When used with a strainer 

Watershield Ceramic filter elements and showerheads are resistant against Chorine and many other 
chemical elements.  
Only use a soft sponge for cleaning. 

Our ceramic filter elements are tested for many contaminants, chemical elements, heavy metals, 
microorganisms and bacteria. 
For a complete test report, please visit our website: www.geniusclearwater.com 

 

Watershield strainer 

Max operating pressure: 

10 bar / 145 PSI 

Minimum operating pressure: 

1.5 bar / 22 PSI 

Max. capacity

*

 

7,500 liters / 1,950 gallon 

Max. operating temperature: 

100 ºC / 212 ºF 

Connection input: 

(BSP) G 1/2" external thread 

Connection output: 

(BSP) G 1/2" internal thread 

* Maximum capacity can vary depending of initial water quality. 

 


background image

 

 3 

Installation guidelines 

Please see figure 1 - figure 11. 

Figure 1, 2 & 3 - installing a strainer:  
- Always pay attention to direction of flow. 
- While showerheads are available in white or chrome, strainers are only available in white. 

- Please note that a strainer is not mandatory, but highly recommended for maximum lifetime of ceramic 
filter elements. 
- Figures shown are 

examples of different applications. 

When a decrease in water flow is noticeable, the filter element is saturated and needs to be replaced.

 

 

Figure 5, 6 & 7 - installing a in-line filter element: 
- Always pay attention to direction of flow. 
- Always make sure that main water supply is closed before (re)placing filter element(s). 

- In-line filters are available in white of chrome. 
- Place in-line filter according to figure 5&6 in cold water supply only or both in cold and warm water 
supply as desired (2 in-line filters required). 
- When a decrease in water flow is noticeable, the filter element is saturated and needs to be replaced. 

Figure 8 - installing a showerhead assembly: 
- Showerhead assembly, available in white or chrome. 
- When a decrease in water flow is noticeable, the filter element is saturated and needs to be replaced. 
- When used conjunction with a strainer, always replace the strainer when replacing the filter element. 

Figure 9, 10 & 11 - installing a in-line filter with strainer 
- Always pay attention to direction of flow. 
- Always make sure that main water supply is closed before (re)placing filter element(s) or strainer. 

- In-line filters are available in white of chrome; strainer only available in white. 
- When a decrease in water flow is noticeable, the filter element is saturated and needs to be replaced. 
- Always replace the strainer when replacing the filter element. 
- Please note that total length of assembly is ca. 35 cm (14 inches). 
- Place in-line filter according to figure 11 in cold water supply only or both in cold and warm water 

supply as desired (2 in-line filters and 2 strainers required). 

 

When in doubt, please ask you local plumbing professional to (re)place your Watershield filter elements!  

 

 

 


background image

  

 

Fig: 5. 

 

Fig: 7. 

 

 

Fig: 8. 

 

Fig: 6. 

 


background image

   

 

 

Fig: 1. 

 

 

Fig: 2. 

 

 

Fig: 3. 

 

 

Fig: 4. 

 


background image

 

Fig: 9. 

 

Fig: 10. 

 