CONTROL BOARD 740 D

1. WARNINGS

Before attempting any work on the control board (connections, maintenan-

ce), always turn off power.

Install, upstream of the system, a differential thermal breaker with adequate 

tripping threshold.

Connect the earth cable to the appropriate terminal on the J7 connector 

of the equipment (see fig.2).

Always separate power cables from control and safety cables (push-but-

ton,  receiver, photocells, etc.). To avoid any electric noise, use separate 
sheaths or a shielded cable (with earthed shield).

2. TECHNICAL SPECIFICATIONS

Power supply (+6% -10% V)

230 V- - 50 Hz

(115 V- - 60 Hz*)

Absorbed power

10 W

(10 W*)

Motor max. load

1000 W

(1200 W*)

Accessories max. load

0,5 A

(0.5 A*)

Operating ambient tempe-

rature

-20 °C +55 °C

Protection fuses

2 (see fig. 1)

Function logics

Automatic / “Stepped” automatic / Semi-au-

tomatic / Safety devices / Semi-automatic B 

/ Dead-man C / “Stepped” semi-automatic 

/ Mixed Log. B+C

Work time

Programmable (from 0 to 4 min.)

Pause time

Programmable (from 0 to 4 min.)

Thrust force

Adjustable over 50 levels

Terminal board inputs

Open / Pàartial opening / Safety devices 

at opng. / Safety devices at clsng. / Stop / 

Edge / Power supply + Earth

On-connector inputs

Opening and closing limit-switches  / Enco-

der

Terminal board outputs

Flashing lamp - Motor - 24 Vdc accessories 

power supply - 24 Vdc indicator-light / Timed 

output. - Fail safe

Rapid connector

5-pin card connection for Minidec, Decoder 

or RP receivers

Programming

3 keys (+, -, F) and display, “basic” or 

“advanced” mode

Basic mode programmable

functions

Function logic - Pause time - Thrust Force 

- Gate direction

Advanced mode program-

mable functions

Torque at initial thrust - Braking - Fail safe 

- Pre-flashing - Indicator-light/Timed output -

 Opening and closing safety devices logic -

 Encoder - Decelerations - Partial opening 

time - Work time - Assistance request - Cycle 

counter

3. LAYOUT AND COMPONENTS

DL

SIGNALLING AND PROGRAMMING DISPLAY

Led

INPUTS STATUS CONTROL LED

J1

LOW VOLTAGE TERMINAL BOARD

J2

CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER

J3

ENCODER CONNECTOR

j4

CAPACITOR CONNECTOR

J5

LIMIT -SWITCH CONNECTOR

J6

MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD

J7

POWER SUPPLY TERMINAL BOARD 230Vac  

(115Vac*)

F1

MOTORS AND TRANSF. PRIMARY FUSE (F 5A)  

(F 10A*)

F2

LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)

F

“F” PROGRAMMING PUSH-BUTTON 

-

“-” PROGRAMMING PUSH-BUTTON

+

“+” PROGRAMMING PUSH-BUTTON

* 740D 115V

Fig. 1

Fig. 1

4. ELECTRIC CONNECTIONS

Fig. 2

Fig. 2

* Only if don’t use J4 connector

* Only if don’t use J4 connector

*

C

J4

230 V   / 50 Hz

or

115 v   / 60Hz

(According to 

the selected 

control unit)

115 Vac

max 60w

(According to 

the selected 

control unit)


background image

13

ENGLISH

 4.1. Connection of photocells and safety devices

Before connecting the photocells (or other devices) we advise you to 

select the type of operation according to the movement area they have 

to protect (see fig.3):

Opening safety devices:

they operate only during the gate opening 

movement and, therefore, they are suitable for protecting the area 

between the opening leaf and fixed obstacles (walls, etc) against the 

risk of impact and crushing.

Closing safety devices:

 they operate only during the gate closing mo-

vement and, therefore, they are suitable for protecting the closing area 

against the risk of impact.

Opening/closing safety devices:

 they operate during the gate opening 

and closing movements and, therefore, they  are suitable for protecting 

the opening and closing areas against the risk of impact.

“Edge” safety devices:

 they operate during the gate opening and closing 

movements and, therefore, they are suitable for protecting the areas 

between the moving leaf and fixed obstacles (pillars, walls, etc) against 

the risk of shearing and dragging.

Encoder (optional):

 operates during the gate opening and closing move-

ments and, therefore, it is suitable for protecting the opening and closing 

area against the risk of impact, crushing, shearing and dragging.

If two or more safety devices have the same function (opening, closing, 
opening and closing, edge), the contacts must be connected to each 
other in series (fig. 4). N.C. contacts must be used.

If safety devices are not used, jumper connect the terminals as shown in 
fig. 5.

The most common photocell and safety device lay-outs are shown below 

(from fig. 6 to fig. 13).

Fig. 3

Fig. 3

Fig. 4

Fig. 4

Connection of two N.C. contacts in series

(e.g. Photocells, Stop, Edge, etc.)

Connection of two N.C. contacts in series

(e.g. Photocells, Stop, Edge, etc.)

Fig. 5

Fig. 5

Connection of no safety device

Connection of no safety device

Fig. 6

Fig. 6

Connection of a closing safety device and an opening safety device

Connection of a closing safety device and an opening safety device

Fig. 7

Fig. 7

Connection of an “edge” safety device

Connection of an “edge” safety device

Fig. 8

Fig. 8

Connection of a pair of photocells for opening

Connection of a pair of photocells for opening

Fig. 9

Fig. 9

Connection of a pair of closing photocells

Connection of a pair of closing photocells

Fig. 10

Fig. 10

Connection of a pair of opening photocells, a pair of closing photocell

and an edge safety device

Connection of a pair of opening photocells, a pair of closing photocell

and an edge safety device

Closing

photocells

Closing photocells

Opening or 

opening/closing

photocells

"Edge" safety devices


background image

14

ENGLISH

Fig. 11

Fig. 11

Connection of two pairs of closing photocells and two edge safety

devices

Connection of two pairs of closing photocells and two edge safety

devices

Fig. 12

Fig. 12

Connection of a pair of closing photocells, a pair of opening photocells

and a pair of opening/closing photocells

Connection of a pair of closing photocells, a pair of opening photocells

and a pair of opening/closing photocells

4.2. J7 Terminal board - Power supply (fig. 2)

POWER SUPPLY (

TERMINALS

PE-N-L):

PE:

Earth connection

N:

230 V- power supply ( Neutral )

L:

  

230 V- power supply ( Line )

For correct operation, the board must be connected to the earth conductor 

in the system. Install an adequate differential thermal breaker upstream 
of the system.

4.3. J6 Terminal board - Motors and flashing lamp (fig. 2)

MOTOR - (terminals 13-14-15):

 Motor connection. In gearmotors with 

a built-in control unit, this connection is pre-wired standard. PFor leaf 

opening direction, see basic programming in Chpt 5.1. 

LAMP - (terminals 16 -17):

 Flashing lamp output ( 230 V -)

4.4. J1 Terminal board  - Accessories (fig. 2)

OPEN A - “Total Opening” command (terminal 1):

 any pulse generator 

(push-button, detector, etc.) which, by closing a contact, commands 

total opening and/or closing of the gate leaf.

To install several total opening pulse generators, connect the N.O. contacts 
in parallel (see fig. 14).

OPEN B - “Partial opening “ or “Closing” command (terminal 2):

 any 

pulse generator (push-button, detector, etc.) which, by closing a 

contact, commands partial opening and/or closing of the gate leaf. 

In the B and C logics, it always commands gate closure.

To install several partial opening pulse generators, connect the N.O. 
contacts in parallel (see fig. 14).

Fig. 13

Fig. 13

Connection of a pair of closing photocells and a pair of

opening/closing photocells

Connection of a pair of closing photocells and a pair of

opening/closing photocells

Fig. 14

Fig. 14

Connection of two N.O. contacts in parallel

(e.g. Open A, Open B)

Connection of two N.O. contacts in parallel

(e.g. Open A, Open B)


background image

15

ENGLISH

FSW OP - Opening safety devices contact (terminal 3):

 The purpose 

of the opening safety devices is to protect the leaf movement area 

during opening. During opening, in the A-AP-S-E-EP logics the safety 

devices reverse the movement of the gate leaves, or stop and restart 

the movement when they are released (see advanced  programming 

in Chpt 5.2). During the opening cycle in logics B and C, they interrupt 

movement. They never operate during the closing cycle.

If the Opening safety devices are engaged when the gate is closed, they 
prevent the leaf opening movement.

To install several safety devices, connect the N.C. contacts in series 
(fig.4).

If no opening safety devices are connected, jumper connect inputs OP and 

-TX FSW (fig. 5).

FSW CL - Closing safety devices contact (terminal 4):

 The purpose of the 

closing safety devices is to protect the leaf movement area during 

closing. During closing, in the A-AP-S-E-EP logics, the safety devices 

reverse the movement of the gate leaves, or stop and reverse the 

movement when they are released (see advanced  programming 

in Chpt 5.2). During the closing cycle in logics B and C, they interrupt 

movement. They never operate during the opening cycle.

If the Closing safety devices are engaged when the gate is open, they 
prevent the leaf closing movement.

 

  To install several safety devices, connect the N.C. contacts in series 

(fig.4).

If no closing safety devices are connected, jumper connect terminals CL 

and -TX FSW (fig. 5).

STOP - STOP contact (terminal 5):

 any device (e.g. a push-button) 

which, by opening a contact, is able to stop gate movement.

To install several STOP devices, connect the N.C. contacts in series.

If STOP devices are not connected, jumper connect the STP and - termi-

nals.

EDGE - EDGE safety device contact (terminal 6):

 The purpose of the 

“edge” safety device is to protect the leaf movement area during 

opening/closing against fixed obstacles (pillars, walls, etc.).  In all 

logics, during opening and closing, the safety devices reverse gate 

leaf movement for 2 seconds. If the safety devices operate again 

during the 2-seconds reversing time, they STOP movement without 

any reversing.

If the Edge safety devices are engaged while the gate is closed or open, 
they prevent the leaves movement.

 

  To install several safety devices, connect the N.C. contacts in series 

(fig.4).

If edge safety devices are not connected, jumper connect the EDGE and 

- inputs. (fig. 5).

- Negative for power supply to accessories (terminals 7 and 8)

+ 24 Vdc - Positive for power supply to accessories (terminals 9 and

10)

Accessories max. load is 500 mA. To calculate absorption values, refer to 

the instructions for individual accessories.

TX -FSW - Negative for power supply to photocell transmitters (terminal 11)

If you use this terminal for connecting the negative for supplying 

power to the photocell transmitters, you may, if necessary, also use 

the FAIL SAFE function (see advanced  programming in Chpt 5.2). 

If this function is enabled, the equipment checks operation of the 

photocells before every opening or closing cycle.

W.L. - Power supply to indicator-light / timed output (terminal 12)

Connect a 24 Vdc - 3 W max indicator-light or timed output, if ne-

cessary, between this terminal and the +24V supply (see advanced 

programming in Chpt 5.2).

To avoid geopardising correct operation of the system, do not exceed the 

indicated power.

4.5. Connector J2 - Rapid connection to Minidec, Decoder and RP

This is used for rapid connection of Minidec, Decoder and RP receivers (see 

fig. 15, 16 and 17). Connect the accessory, with the components side facing 

the inside of the board. Insert and remove after cutting power.

4.6. Connector J6 - Limit-switches rapid connection (fig.2)

This input is intended for rapid connection of the opening  and closing  

limit-switches designed to stop the leaf, or for start of decelerations or for 

braking  (see advanced programming in Chpt. 5.2.). In gearmotors with a 

built-in control unit, this connection is pre-wired as standard (fig. 2). For leaf 

opening direction, see advanced programming in Chpt 5.2.

4.7. Connector J3 - Encoder rapid connection (fig.2)

This input is designed for rapid connection of the Encoder (optional). To fit 

the encoder on the motor, refer to the relevant instructions.

The presence of the encoder is signalled - when the gearmotor is running 

- by the flashing of the “Encoder” LED on the board.

When the encoder is used, the control unit knows the exact position of the 

gate while it is moving.

The encoder controls the adjustments of some of the control unit’s func-

tions in a different way (partial opening or deceleration - see advanced 

programming in Chpt 5.2) and as an anti-crushing device. 

If the gate strikes an obstacle during opening or closing, the encoder im-

mediately reverses the gate leaf for 2 seconds.  If the encoder operates 

again during the 2-seconds reversing time, it STOPS movement without 

commanding any reversing.

Fig. 15

Fig. 15

Fig. 16

Fig. 16

Fig. 17

Fig. 17


background image

16

ENGLISH

5. PROGRAMMING

To program operation of the automated system, you have to access the 

“PROGRAMMING” mode. 

Programming is split into two parts: BASIC and ADVANCED.

5.1. BASIC PROGRAMMING

To access BASIC PROGRAMMING, press  key 

F

:

if you press it (and hold it down), the display shows the name of the first 

function.

if you release the key, the display shows the value of the function that can 

be modified with keys 

+

 and 

-

.

if you press 

F

 again (and hold it down), the display shows the name of 

the next function, etc.

when you reach the last function, press 

F

 to exit the program, and the 

display resumes showing the gate status.

The following table shows the sequence of functions accessible in BASIC 

PROGRAMMING:

BASIC PROGRAMMING

F

Display

Function

Default

LO

FUNCTION LOGICS (see tab. 3/a - h):

A

    =Automatic

AP

  =“Stepped” automatic 

S

     = “Safety”  Automatic

E

     = Semi-automatic

EP

   = “Stepped” Semi-automatic

C

     = Dead-man

b

      = “B” Semi-automatic

bC

   = Mixed Log. (

b

 opening / 

C

 closing)

EP

PA

PAUSE TIME:

This has effect only if the automatic logic was 

selected. Adjustable from 

0

 to 

59

 sec. in one-

second steps.

Subsequently, display changes to minutes and 

tens of seconds (separated by a point) and time 

is adjusted in 10-second steps, up to the maximum 

value of 

4.1

 minutes.

E.g. if the display shows 

2.5

, pause time is 2 min. 

and 50 sec.

2.0

F0

FORCE:

Adjusts Motor thrust.

01

 = minimum force

50

 = maximum force

50

d1

OPENING DIRECTION:

Indicates the gate opening movement and 

makes it possible not to change the motor and 

limit-switch connections on the terminal board.

-3

 = Right-hand opening movement 

E-

 = Left-hand opening movement

-3

St

GATE STATUS:

Exit from programming and return to gate status 

viewing.

00

 = Closed

01

  = Now opening

02

 = Stopped

03

 = Open

04

 = Pause

05

 = “FAIL SAFE” tripped (chpt. 5.2)

06

 = Now closing

07

 = Now reversing

08

 = Photocells tripped

5.2. ADVANCED PROGRAMMING

To access ADVANCED PROGRAMMING, press key 

F

 and, as you hold it 

down, press key 

+

:

if you release key 

+

 , the display indicates the name of the first function.

if you release key F too, the display shows the value of the function that 

can be modified with keys 

+

 and 

-

.

if you press key 

F

 (and hold it down), the display shows the name of the 

next function, and if you release it, the value that can be modified with 

keys 

+

 and 

-

 is shown.

when you reach the last function, press 

F

 to exit the program, and the 

display resumes showing the gate status.

The following table shows the sequence of functions accessible in ADVAN-

CED PROGRAMMING:

ADVANCED PROGRAMMING

F +

+

Display

Function

Default

b0

MAXIMUM TORQUE AT INITIAL THRUST:

The motor operate at maximum torque (ignoring 

the torque setting) at start of movement. Useful 

for heavy leaves.

Y

    = Active

no

  = Disabled

Y





ADVANCED PROGRAMMING

F +

+

Display

Function

Default

br

FINAL BRAKING:

When the gate engages the opening or closing 

limit-switch, a braking stroke can be selected 

to ensure the leaf is stopped immediately. If 

decelerations are selected, braking starts when 

they finish.

At 

00

 value,  braking is disabled. 

Time can be adjusted from 

01

 to 

20

 sec. in 0.1-

second steps.

E.g. if the display indicates 

10

, braking time is 1 

second.

00

 = Braking disabled

from 

01

 to 

20

 = Timed braking

05

FS

FAIL SAFE:

If this function is activated, it enables a function 

test of the photocells before any gate movement. 

If the test fails (photocells not serviceable signal-

led by value 

05

 on the display), the gate does 

not start moving.

Y

   = Active 

no

 = Disabled

no

PF

PRE-FLASHING (5 s):

Activates the flashing lamp for 5 seconds before 

start of movement.

no

 = Disabled

oP

 = Only before opening 

CL

 = Only before closing

OC

 = Before every movement 

no

SP

INDICATOR-LIGHT:

If

00

 is selected, the output functions as a stan-

dard indicator-light (lighted at opening and 

pause, flashing at closing, and off when gate 

closed).

Courtesy light:

 Different figures correspond to ti-

med activation of the output, which can be used 

(by a relay) to power a courtesy lamp. Time can 

be adjusted from 

0

 to 

59

 sec. in 1-second steps, 

and from 

1.0

 to 

4.1

 min. in 10-second steps.

Electric lock command and ‘traffic lights’ fun-

ctions:

If you press key  

-

  from the 

00

 setting, the 

command for the 

E1 

closing electric lock is 

activated;
If you press  

-

  again, the command for the 

E2

closing and opening electric lock is set;
if you press the  

-

 key again, you can set the 

‘traffic lights’ functions 

E3

 and 

E4

.

00

 = Standard indicator-light

from 

01

 to 

4.1

 = Timed output.

E1

 = electric lock command before opening 

movement

E2

 = electric lock command before opening and 

closing movements

E3

 = ‘traffic lights’ function: the output is active 

in “open” and “open on pause” status and is 

disabled 3 seconds before the closing manoe-

uvre starts.

 there is 3 seconds of pre-flashing before the 

closing manoeuvre.

E4

 = ‘traffic lights’ function: the output is active 

only in “closed” status.

 Do not exceed the output’s maximum load 

(24Vdc-3W). If necessary, use a relay 
and a power supply source outside the 
equipment.

00

Ph

CLOSING PHOTOCELLS LOGIC:

Select the tripping mode of the closing photo-

cells.

They operate for the closing movement only: they 

stop movement and reverse it when they are 

released, or they reverse it immediately.

Y

   = Reverse on release

no

 = Reverse immediately   when opening

no

oP

OPENING PHOTOCELLS LOGIC:

Select the tripping mode of the opening pho-

tocells.

They operate for the opening movement only: 

they stop the movement and restart  it when they 

are released, or they reverse it immediately.

Y

   = Reverse immediately when closing

no

 = Restart movement on release

no


background image

17

ENGLISH

ADVANCED PROGRAMMING

F +

+

Display

Function

Default

EC

ENCODER:

If the encoder is used, you may select its pre-

sence.

If the encoder is present and enabled,  “decele-

rations” and “partial opening”  are controlled by 

the encoder (see relevant paragraphs).

The encoder operates as an anti-crushing device: 

If the gate strikes an obstacle during opening or 

closing, the encoder immediately reverses  gate 

leaf movement for 2 seconds.  If the encoder ope-

rates again during the 2-seconds reversing time, 

it stops movement (STOP) without commanding 

any reversing. If no sensor is supplied, the para-

meter must be set on 

00

. If there is the encoder, 

adjust the sensitivity of the anti-crushing system, 

by varying the parameter between 

01

 (maximum 

sensitivity) and 

99

 (minimum sensitivity).

From 

01

 to 

99

 = Encoder active and sensitivity 

adjustment

00

 = Encoder disabled

00

rP

Pre-limit switch DECELERATION:

You can select gate deceleration before the 

opening and closing limit-switches have been 

tripped.

Time can be adjusted from 

00

 to 

99

.

If an encoder is used, the adjustment is not deter-

mined by time but by motor revs, thus obtaining 

greater deceleration precision.

00

 = Deceleration disabled

from 

01

 to 

99

 = Deceleration enabled

00

rA

Post-limit switch DECELERATIONS:

You can select gate deceleration after the 

opening and closing limit-switches have been 

tripped.

Time can be adjusted from 

00

 to 

20

 sec. in 0.04-

second steps.

If an encoder (optional) is used, the adjustment 

is not determined by time but by motor revs, thus 

obtaining greater deceleration precision.

00

  = Deceleration disabled

from 

01

 to 

20

 = Deceleration enabled

05

PO

PARTIAL OPENING:

You can adjust the width of leaf partial ope-

ning.

Time can be adjusted from 

01

 to 

20

 sec. in 0.1-

second steps.

If an encoder (optional) is used, the adjustment 

is not determined by time but by motor revs, thus 

obtaining greater precision of partial opening. 

E.g.

for a gate with a sliding speed of 10 m /min, 

value 

10

 corresponds to about 1.7 metres of 

opening.

E.g.

for a gate with a sliding speed of 12 m 

/min, value 

10

 corresponds to about 2 metres 

of opening.

05

t

WORK TIME:

We advise you to set a value of 5 to 10 seconds 

over the time taken by the gate to travel from the 

closing limit-switch to the opening limit-switch and 

vice versa.  This will protect the motor against any 

overheating if a limit-switch fails.

Adjustable from 

0

 to 

59

 sec. sec. in one-second 

steps.

Subsequently, viewing changes to minutes and 

tens of seconds (separated by a point) and time 

is adjusted in 10 second steps, up to a maximum 

value of 

4.1

 minutes.

E.g.

if the display shows

2.5

, work time is 2 min. 

and 50 sec.

 the set value does not exactly match the mo-

tor’s maximum operating time, because 
the latter is modified according to the 
performed deceleration spaces.

4.1

AS

ASSISTANCE REQUEST (combined with next fun-

ction):

If activated, at the end of countdown (settable 

with the next function i.e. “Cycle programming”) 

it effects 2 sec. of pre-flashing (in addition to the 

value already set with the PF function) at every 

Open pulse (job request). Can be useful for setting 

scheduled maintenance jobs.

Y

   = Active

no

 = Disabled

no

ADVANCED PROGRAMMING

F +

+

Display

Function

Default

nc

CYCLE PROGRAMMING:

For setting countdown of system operation cycles. 

Settable (in thousands) from 

00

 to 

99

 thousand 

cycles.

The displayed value is updated as cycles pro-

ceed.

This function can be used to check use of the 

board or to exploit the “Assistance request”.

00

St

GATE STATUS:

Exit from programming and return to gate status 

viewing (see Chpt 5.1.).

6. START-UP

6.1. INPUTS CHECK

The table below shows the status of the LEDs in relation to to the status of 

the inputs.

Note the following:

Led lighted

  = closed contact

 

 

 

Led off

   = open contact

Check the status of the LEDs as per Table.

Operation of the signalling status LEDs

d1 = -3

= Right-hand opening movement

LEDS

LIGHTED

OFF

FCA

Limit-switch free

Limit-switch engaged

FCC

Limit-switch free

Limit-switch engaged

OPEN B

Command activated

Command inactive

OPEN A

Command activated

Command inactive

FSW OP

Safety devices disengaged

Safety devices engaged

FSW CL

Safety devices disengaged

Safety devices engaged

STOP

Command inactive

Command activated

EDGE

Safety devices disengaged

Safety devices engaged

The status of the LEDs while the gate is closed at rest are shown in 
bold.

d1 = E-

= Left-hand opening movement

LEDS

LIGHTED

OFF

FCA

Limit-switch free

Limit-switch engaged

FCC

Limit-switch free

Limit-switch engaged

OPEN B

Command activated

Command inactive

OPEN A

Command activated

Command inactive

FSW OP

Safety devices disengaged

Safety devices engaged

FSW CL

Safety devices disengaged

Safety devices engaged

STOP

Command inactive

Command activated

EDGE

Safety devices disengaged

Safety devices engaged

The status of the LEDs while the gate is closed at rest are shown in 
bold

7. AUTOMATED SYSTEM TEST

When you have finished programming, check if the system is operating 

correctly.

Most important of all, check if the force is adequately adjusted and if the 

safety devices are operating correctly.

Note 1

:

to reset the programming default settings, check if the edge 

input is opened (SAFE LED OFF), and simultaneously press keys 

+,  

-

and

F

, holding them down for 5 seconds.

Note 2:

modification of programming parameters comes into effect 

immediately, whereas definitive memory storage occurs only 

when you exit programming and return to gate status viewing. If 

the equipment is powered down before return to status viewing, 

all modifications will be lost.


background image

18

ENGLISH

Tab.

3/a

LOGIC

”A

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf and closes it 

after pause time 

/

Opens leaf for the partial  opening time and closes 

after pause time 

/

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN

on

PA

USE

Reloads pause time 

/

Stops operation

No effect

Reloads pause time 

/

 (OPEN disabled)

No effect (OPEN disabled)

ON

CL

OSING

Re-opens the leaf immediately 

/

No effect (saves OPEN)

see paragraph 5.2.

Stops and, on r

elease, 

re

verses on opening

Re

verses on opening for 2” 

0

ON

OPENING

No effect 

/

see paragraph 5.2.

No effect

Stops and, on r

elease, 

continues opening

Re

verses on closing for 2” 

0

STOPPED

Closes the leaf

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

Tab.

3/b

LOGIC

“AP”

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf and closes it 

after pause time 

/

Opens leaf for the partial  opening time and closes 

after pause time 

/

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN

on

PA

USE

Re-closes the leaf immediately

Stops operation

No effect

Reloads pause time 

/

 (OPEN disabled)

No effect (OPEN disabled)

ON

CL

OSING

Re-opens the leaf immediately 

/

No effect (saves OPEN)

see paragraph 5.2.

Stops and, on r

elease, 

re

verses on opening

Re

verses on opening for 2” 

0

ON

OPENING

Stops operation

see paragraph 5.2.

No effect

Stops and, on r

elease, 

continues opening

Re

verses on closing for 2” 

0

STOPPED

Closes the leaf

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

Tab.

3/c

LOGIC

”S”

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

 Opens leaves and closes 

them  after pause time

Opens leaf for the partial  opening time and closes 

after pause time 

/

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN

on

PA

USE

Re-closes the leaf immediately

Stops operation

No effect

Closes after 5” (OPEN disabled)

No effect (OPEN disabled)

ON

CL

OSING

Re-opens the leaf immediately

No effect (saves OPEN)

see paragraph 5.2.

Stops and, on r

elease, 

re

verses on opening

Re

verses on opening for 2” 

0

ON

OPENING

Re-closes the leaf immediately

see paragraph 5.2.

No effect

Stops and, on r

elease, 

continues opening

Re

verses on closing for 2” 

0

STOPPED

Closes the leaf

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)


background image

19

ENGLISH

Tab.

3/d

LOGIC

“E”

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf

Opens the leaf for partial 

opening time 

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN

Re-closes the leaf immediately

Stops operation

No effect

No effect (OPEN disabled)

ON

CL

OSING

Re-opens the leaf immediately

No effect (saves OPEN)

see paragraph 5.2.

Stops and, on r

elease, 

re

verses on opening

Re

verses on opening for 2” 

0

ON

OPENING

Stops operation

see paragraph 5.2.

No effect

Stops and, on r

elease, 

continues opening

Re

verses on closing for 2” 

0

STOPPED

Closes the leaf (with the Closing safety devices enga-

ged, it opens at the 2

nd

 pulse)

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

Tab.

3/e

LOGIC

“”EP””

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf

Opens the leaf for partial 

opening time

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN

Re-closes the leaf immediately

Stops operation

No effect

No effect (OPEN disabled)

ON

CL

OSING

Stops operation

No effect (saves OPEN)

see paragraph 5.2.

Stops and, on r

elease, 

re

verses on opening

Re

verses on opening for 2” 

0

ON

OPENING

see paragraph 5.2.

No effect

Stops and, on r

elease, 

continues opening

Re

verses on closing for 2” 

0

STOPPED

Restarts movement in r

e

verse dir

ection (always closes 

after a Stop)

No effect (OPEN disabled)

No effect (if it must open

, it 

disables OPEN)

No effect  (if it must close, it 

disables OPEN)

No effect (OPEN disabled)

Tab.

3/f

LOGIC

“C

CONTROLS

AL

W

A

YS

HELD

DOWN

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

(opening)

OPEN-B

(closing)

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf

No effect

No effect (OPEN-

A

 disabled)

No effect (OPEN-B disa-

bled)

No effect (OPEN-

A

 disa-

bled)

No effect (OPEN-

A

/B disa-

bled)

OPEN

No effect

Closes the leaf

No effect (OPEN-B disa-

bled)

No effect (OPEN-

A

 disa-

bled)

No effect (OPEN-B disa-

bled)

ON

CL

OSING

Stops operation

Stops operation

No effect

Stops operation (OPEN-B 

disabled)

Stops operation  (OPEN-

A

/B 

disabled)

Re

verses on opening for 2” 

0

ON

OPENING

Stops operation

Stops operation (OPEN-

A

 

disabled)

No effect

Re

verses on closing for 2” 

0


background image

20

ENGLISH

Tab.

3/g

LOGIC

”B

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

(opening)

OPEN-B

(closing)

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf

No effect

No effect (OPEN-

A

 disabled)

No effect (OPEN-B disa-

bled)

No effect (OPEN-

A

 disa-

bled)

No effect (OPEN-

A

/B disa-

bled)

OPEN

No effect

Closes the leaf

No effect (OPEN-B disa-

bled)

No effect (OPEN-

A

 disa-

bled)

No effect (OPEN-B disa-

bled)

ON

CL

OSING

Re

verses on opening

No effect

Stops operation

No effect

Stops operation (OPEN-B 

disabled)

Stops operation  (OPEN-

A

/B 

disabled)

Re

verses on opening for 2” 

0

ON

OPENING

No effect

Stops operation (OPEN-

A

 

disabled)

No effect

Re

verses on closing for 2” 

0

STOPPED

Opens the leaf

Closes the leaf

No effect (OPEN-

A

/B 

disabled)

No effect (OPEN-

A

 disa-

bled)

No effect (OPEN disabled)

No effect (OPEN-

A

/B disabled)

Tab.

3/h

LOGIC

“BC

OPENING

PULSES

/

CL

OSING

COMMANDS

A

LW

A

Y

S

PRESSED

PULSES

G

A

TE

ST

A

TUS

OPEN-

A

(opening)

OPEN-B

(closing)

STOP

OPENING

SAFETY

DEVICES

C

LOSING

SAFETY

DEVICES

OP/CL

OS.

SAFETY

DEVICE

EDGE

SAFETY

DEVICE

CL

OSED

Opens the leaf

No effect

No effect (OPEN-

A

 disabled)

No effect

No effect (OPEN-

A

 disabled)

OPEN

No effect

Closes the leaf

No effect (OPEN-B disa-

bled)

No effect

No effect (OPEN-B disabled)

No effect (OPEN-

A

/B disa-

bled)

ON

CL

OSING

Re

verses to open

No effect

Stops operation

No effect (saves OPEN A)

Stops operation (OPEN-B 

disabled)

Stops operation (OPEN-

A

/B 

disabled)

Re

verses to open for 2” 

0

ON

OPENING

No effect

Stops operation (OPEN-

A

 

disabled)

No effect

Re

verses to close for 2” 

0

STOPPED

Opens the leaf

Closes the leaf

No effect (OPEN-

A

/B 

disabled)

No effect (OPEN-

A

 disa-

bled)

No effect (OPEN-B disa-

bled)

No effect (OPEN-

A

/B disabled)

/

 If maintained, it pr

olongs the pause until disabled by the command (timer function)

0

 If a new pulse occurs within 2 seconds after r

e

versing, it immediately stops operation

.

 Effects on other active pulse inputs in brack

ets

.

• •