Evak DPC-10 Operation Manual

Made by: Evak
Type: Operation Manual
Category: Controller
Pages: 10
Size: 1.77 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

www.evak-pumps.com

Vol.PMDPC-18091-1.2R2-2IN2OUT

DPC-10

Wa

t

er

P

u

u

m

m

p Digital Pressure Controller

Instal

la

la

tion and Operation Manual

EVAK PUMP TECHNOLOGY CORP.

No. 551, Zhongshan Rd., Qingshui Dist., Taichung City 436, Taiwan.

TEL:

 +886-4-26233556    

Fax:

 +886-4-26235559

11.Warning

!

Assemble tool

Do not poke the port

!

Do not pull the cable

 Wire conductors must not be exposed to avoid any shortage from the conductor end.

!

WARNING


background image

02

1.DPC-10 Panel introduction

2.Technical data

Supply voltage: 110-230Vac ± 10%  50/60HZ

Maximum ambient temperature: +40

Maximum liquid temperature: +65

Maximum system pressure: 10bar

Maximum contact load AMP: 12A

Ingress Protection Rating: IP55

Model Number

LED Light

LCD Display

Technical Data

Button

Pressure Unit

»

»

»
»

»
»

» Relay Capacity: 1HP in 110V or 2HP in 230V
» The digital pressure controller can control pump with 

higher output through a contactor with control circuit 
voltage of 110Vac or 230Vac, in the other hand, the
supply voltage to DPC is 110Vac or 230Vac 50/60hz,
please refer to the wiring diagram for requirement.

Dry Running

Digital Pressure Controller

DPC-10

Over Pressure

bar
kg/cm

2

psi

Power :110-230Vac±10% 50/60HZ

Max :12A / Max :10bar / IP55


background image

3.Wiring diagram

 Incorrect wiring could cause damage to the pressure controller,
 

confirm the color of the wires with the operation manual before wiring. 

04

a. Single phase wiring connection 

b. Three phase wiring connection-230V

c. Three phase wiring connection-380V

3 phase PUMP

M1

U        V        W

3

3W AC 230V

R         S        T

3 phase PUMP

M1

DPC-10

Controller

Gray

Brown

Blue

Black

U         V        W

3 4W AC 380V

R         S         T        N

   NFB

(MCCB)

AC 230V

M1

Coil

If connecting to a pump driven by 3ph/380V pump (Please 

AC 110V,230V

   NFB

(MCCB)

1

NFB

(MCCB)

L        N

If installing DPC-10 with a varistor, please connect varistor wire in parralled with 

thin Brown and Blue wires of the DPC-10.

 

*

note the power voltage must not exceed 400V.), the blue wire must not 
connect to R or S wire, otherwise the DPC-10 controller will be burned out.

 220V( <250V)

Note: If the voltage is over 250V, please add transformer by yourself. 

DPC-10

Controller

Gray

Brown

Blue

Black

AC 230V

M1

Coil

DPC-10

Controller

Gray

Brown

Blue

Black

1 phase PUMP

 WARNING

!

 WARNING

!

 WARNING

!

Any connection to the contactor, please add a  
R.C capacitor (spark eliminator) to reduce the 
possible electromagnetic interference.

 WARNING

!

Beware of any connection to the contactor. 
Please add a R.C. capacitor (spark eliminator) to 
reduce the possible electromagnetic interference.

4.Button Function Introduction

Button Icon

Function

Browsing original pressure value.

Downward adjustment of the parameter value.

Pump start and stop operation

Upward adjustment of the parameter value.

Possible with Button

Short press once:
Switch to Basic parameter setting 

Hold down the botton for 3 seconds: 
Switch to Advance parameter setting

After entering the parameter setting,short press once again: 
Switch to next setting mode and enter the set value  

Long press for 6 seconds to Lock/Unlock the SET button for privacy.


background image

06

“           ” (Short press once to enter Basic Setting Mode)

Setting procedure : 

Max. pressure 

 Min. start pressure 

 

Time-Delay

Item Parameters Display

Code

Default

Unit

Data

Range

P-max kg/cm² 0.01-

10.00

Description

Max. pressure 

setting

(high pressure)

a.Select to modify Max. Pressure, press the 

left or right button to adjust the value, after 

finishing the setting, press the SET button 

once and go to Min. start pressure 

1

0-60

kg/cm²

sec

-

-

P-min

Delay

loAd

Min. start 

pressure setting 

(low pressure)

Time-Delay 

setting when

reaching the 

Max. Pressure 

Load for 3 

seconds to store  

 setting value 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.    
c.Choose not to modify the pressure, press

 the SET button, and go to next parameter 

setting.

a.Select to modify Min. start pressure , press 

the left or right button to adjust the value,

after finishing the setting, press the SET 

button once and go to Time-Delay setting .

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.    

c. Choose not to modify the pressure, press 

the SET button, and go to next parameter 

setting.

a.Select to modify the Time-delay setting 

when reaching the Max. Pressure, press 

the left or right button to adjust the value, 

after finishing the setting, press the SET 

button and go to " loAd " display. 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.    

c.Choose not to modify the delay time, press 

the SET button, and LCD display " loAd "

The above setting value is stored and after 

3 seconds will automatically return  to the 

current pressure value.

2

3

4

setting.

0.01-

10.00

5.The status of LED lights 

6.Parameter display and settings

Item

Light

Message indication 

Control loop off from the system

Non

Green
Orange 

Red 

Pump status

Control loop commands the system 

pump to start running

Control loop is loaded into the system

Warning message to shut down the

system temporarily

Pump off

Pump on

Pump standby

Pump auto stop and display   

the fault message (Dry running

1

2
3

4

Item Parameter Display

Code

Default

Unit

P-max kg/cm²

kg/cm²

kg/cm²

P-min

P-Dry

Description

Pressure of 

water shortage 

setting display 

(Dry running)

Min. Pressure

setting display

Max. Pressure

setting display

» Press once: To see the Max. pressure setting value.

» Or stay on this screen for 5 seconds it will automatically 

 return to the current pressure status display.

» Press again: To see the Min. pressure setting value. 

» Or stay on this screen for 5 seconds it will automatically 

return to the current pressure status display.

» Press again: To see the pressure of  water shortage  

setting value.

» Or stay on this screen for 5 seconds it will automatically 

return to the current pressure status display.

1

2

3

“            ” (Pressure value display)

 or Over pressure)

Item Parameter Pump action

Description

Stop (OFF)

Restart (ON)

Pump off

Non

Pump on

Orange  Press once to restart the pump running.

Hold down for 3 seconds to stop the pump 

1
2

“            ” (Restart or stop the pump running)

running.

Light

Lock/Unlock

Setting function

kg/cm²

Long press for 6 seconds (Lock/Unlock the SET button)


background image

“              ” Hold down for 3 seconds (Advanced setting Mode)

Item Parameters Display

Code

Default

Unit

Data

Range

Unit

-

-

Description

Switch the 

display working 

pressure unit 

a.Select to switch the Unit of working 

pressure, press the right button to change 

the pressure unit (Cycle : kg/cm² 

→ Psi 

→ bar → 

kg/cm²), then press the SET 

button once and go to next parameter    

setting. 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.  
c.Choose not to modify the working pressure 

unit, press the SET button once, and go 

to next parameter setting.

1

P-Dry

sec 1-120

0.01-

10.00

P-Dry

Detection time

setting of water

shortage

Pressure of 

water shortage 

setting 

(Dry running)

a.Select to modify the detection time after 

reaching the pressure setting of water 

shortage (Dry running), press the left or 

 

right button to adjust the value, after 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.  

c.Choose not to modify P-Dry detection time 

setting, press the SET button once, and 

go to next parameter setting.

a.Select to modify the Pressure of water 

shortage, press the left or right button to 

adjust the value, after finishing the setting, 

press the SET button and go to next 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.  
c.Choose not to modify the pressure of water 

shortage, press the SET button, and go

to next parameter setting.

2

3

0-600

sec

hour

Auto

Reset

Auto

Time setting of 

automatic 

re-start running 

after warning 

shutdown (Dry 

running or 

Over pressure) 

(

α

 value)

Auto shutdown

 setting after 

continuous 

running

a.Select to modify automatic re-start time, 

press the left or right button to adjust the 

value, after finishing the setting, press the SET 

button, and go to next parameter setting.  

The time of automatic re-start = (automatic 

time setting) x (trip times)³

(Cumulative trip times is up to 10 times, if  

pressing the right button to re-start, then the 

trip times can be re-calculated.)

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.  

c.Choose not to modify the automatic re-start 

time, press the SET button, and go to next 

parameter setting.

a.Select to modify the auto shutdown setting 

   after continuous running, press the left or 

   right button to adjust the value, after finish-

   ing the setting, press the SET button and 

   go to next parameter setting.
 

  St-0: 

Pressure controller keeps running 

   and won’t shut down automatically.

  St-.5: 

Pressure controller will auto shut 

   down after continuously running 0.5 hours 

   and won’t auto restart after the shutdown.

   

St-1-5: 

Pressure controller will auto shut 

   down after continuously running 1-5 hours 

   and won’t auto restart after the shutdown.

4

5

finishing the setting, press the SET button  

kg/cm²

parameter setting.

Item Parameters Display

Code

Default

Unit

Data

Range

Description

and go to next parameter setting. 

St-0

St-.5

St-1

-

St-5

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.  

c.Choose not to modify the automatic re-start 

time, press the SET button, and go to next 

parameter setting.

08


background image

7.Standard default value (Factory preset settings)

10

8.Setting value range

a. Pressure setting range : 0.01 - 10.00bar

b. Time-Delay setting range : 0 - 60 seconds

c. Detection time after Dry-running setting range: 1-120 seconds

d. Time of automatic re-start running after warning shutdown

    (α value) setting range : 0   600 seconds

e. Auto shutdown setting range: None and 0.5-5Hours

a. Max. pressure value : 2.5 kg/cm²

b. Min. pressure value : 1.5 kg/cm²

c. Delay Time when reaching the Max. Pressure : 15 seconds

d. The pressure unit : kg/cm²

e. Detection time of water shortage : 30 seconds

f.  Pressure of water shortage : 0.5 kg/cm²

g. Time of automatic re-start running after warning shutdown  

     (α value) : 60 seconds

h. Auto shutdown setting after continuous running : St-0

i.  Over pressure value is fixed in 10bar and cannot modify

-

-

dF-n

dF-y

-

-

- - - -

or

loAd

Restore to 

default value 

setting

LCD screen 

display “loAd” 

or “ ----” for 3 

seconds to 

store and finish 

the setting

a.Select to restore default value settings 

(dF-y), press the right button and adjust the  

parameter value from dF-n to dF-y.  

After finishing the setting, press the SET  

button, then all the advanced value 

settings are returned to default value. 

LCD screen will display "- - - -" for 3 seconds 

and return to the current pressure conditions.

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.  

c.Choose not to return to default value 

settings (dF-n), select dF-n and press the 

SET button again, LCD screen display 

"loAd" for 3 seconds and will 

return to the 

After LCD screen displaying “loAd” or “ ----”

for 3 seconds, above setting value is stored

and it will automatically return to the current

pressure value.      

6

7

Item Parameters Display

Code

Default

Unit

Data

Range

Description

 

current pressure conditions automatically. 

9.The current operating parameters display

1).Max. pressure setting display 

(high pressure) (Show code P-max)

2).Min. start pressure setting display (low pressure) (Show code P-min)

↓ Press             once

a-1. Press          once to browse original pressure value 

↓ Press             once

3).Pressure of water shortage setting display (Dry running) 

    (Show code P-Dry)

↓ Press              again


background image

12

1).Lock the SET button after long press           for 6 seconds

    (Show code         )

2).Unlock SET button after long press         again for 6 seconds 

    (Show code UnL)

a-2. Long Press          for 6 seconds to Lock/Unlock the SET button

1).Max. pressure setting (high pressure) (Show code P-max)

b. Press          once to enter basic setting

Press   

to adjust the value upward

     

Press        

to adjust the value downward

2).Min. Start pressure setting (low pressure) (Show code P-min)

↓ Press            once

Press    

to adjust the value upward

     

Press           

to adjust the value downward

↓ Press            once


background image

14

1).Change the display working pressure unit (Show code Unit)

3).Time-Delay setting after reaching the Max. Pressure 

   (Show code Delay)

4).All parameter settings is stored (Show code loAd)

c. Press            for 3 seconds to enter advanced setting

Press    

to adjust the value upward

     

Press          

to adjust the value downward

 Press         once

 3 seconds later

5).After finishing above setting, 3 seconds later will return to the 

    current pressure status display automatically.

Press           to set up unit

 

Cycle of working pressure unit: 

kg/cm² 

→ 

psi 

→ 

bar 

→ 

kg/cm²

 Press         once


background image

16

2).Detection time setting of water shortage 

(Show code P-Dry & sec)

3).Pressure of water shortage setting (Show code P-Dry)

5). Auto shutdown setting after continuous running 

(Show code Aut

o)

Press    

to adjust the value upward

     

Press          

to adjust the value downward

↓ Press            once

4).Time setting of automatic re-start running after warning shutdown 

    (Dry running or Over pressure) (α value) (Show code Auto reset)

Press    

to adjust the value upward

     

Press           

to adjust the value downward

↓ Press           once

Press    

to adjust the value upward

     

Press           

to adjust the value downward

↓ Press           once

» St-0: Pressure controller keeps running and will not automatically

shut down.

    St-.5&St-1-5: Pressure controller will auto shut down after 

     continuously running 0.5 or 1-5 hours and will not automatically 

     restart after the shutdown.

» 

Press    

to adjust the value upward

     

Press           

to adjust the value downward

↓ Press           once


background image

When the pressure controller 

displays "EEEE" the pressure 

sensor has failed.

When the pressure controller 

displays "FFFF" the temperature 

sensor has failed.

When the pressure controller 

displays "EEFF" the pressure and 

temperature sensor have failed.

b).FFFF

c).EEFF

a).EEEE

10.Fault Display 

18

6).Restore to default value setting or not

To restore default value settings (show code dF-y)

» 

Press           to adjust the value to dF-y

Press           once and restore to default value (Show code ----)  

7).After finishing above settings, LCD screen display “loAd” or “ ----”

    3 seconds later, above setting value is stored and it will 

    automatically return to the current pressure value.

Not to restore default value settings (show code dF-n)

» 

Press          to set the value to dF-n

Press          once then all settings are stored. (Show code loAd)