background image

 

 

 

IP-SDI gateway SFP+ 

(coaxial front end) 

 
 

User guide 

v0.4

 

 

 

 

Product:

 

EB22 family 

April 7

th

, 2016

 

 

 

 

 

 

 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

 

Table of contents 

 

1.

 

Introduction

 ......................................................................................................................................... 3 

2.

 

Overview

 .............................................................................................................................................. 3 

3.

 

Required tools

 ..................................................................................................................................... 3 

4.

 

Installing SFP+ modules

 .................................................................................................................... 3 

5.

 

Removing SFP+ modules

 .................................................................................................................. 4 

6.

 

Connecting SDI signals to the SDI to IP gateway

 .......................................................................... 5 

7.

 

Configuring the SDI to IP gateway by the 10GE network

 .............................................................. 6 

8.

 

Updating the SDI to IP gateway (by the internal webpage)

 .......................................................... 9 

9.

 

Troubleshooting the modules

 ......................................................................................................... 11 

 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

 

1.

 

Introduction 

 

This  installation & configuration quick user guide  provides the  installations for the  Embrionix 

SDI to IP coaxial gateway SFP+ (emSFP). These gateway modules are hot-swappable devices 

that  plug  into  a  10GE  MSA  SFP  slot;  10GE  (2022-6)  signal  is  received/transmitted  on  host 

interface. 

 

Figure 1. SDI to IP coaxial gateway

 

2.

 

Overview 

 

The SFP+ (emSFP) modules are hot-pluggable I/O devices that plug into sockets (SFP/SFP+).   

3.

 

Required tools 

 

ESD-preventive wrist strap  

4.

 

Installing SFP+ modules 

 

Step 1

 

Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector or a 

bare metal surface on your chassis. 
 

Step 2 

Remove the SFP transceiver module from its protective packaging. 

 

Step 3

 

Position the SDI to IP coaxial gateway SFP+ in front of the empty cage. 

 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

Step 4

 

Insert the SFP+ like the following pictures. 

 

Figure 2. SDI to IP coaxial gateway insertion

 

 

Note

 

Ensure the ejector is at rest position before inserting the SFP+ in the cage. 

 

 

Step 5

 

Press the SFP+ until you feel the connector latch into place. 

 

Step 6 

Verify the SFP+ is seated and latched properly by grasping the SFP+ and try to remove it 

without releasing the latch. 
 

5.

 

Removing SFP+ modules 

 

Note

 

The SFP and SFP+ are static sensitive devices. It is recommended to use an ESD wrist strap or 

similar grounding device when handling the modules.

 

 

 

Step 1

 

Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector or a 

bare metal surface on your chassis. 
 

Step 2

 

 Release and remove the transceiver module from the socket connector, as shown in 

next figure (Step 2a) push the ejector gently in a slightly upward direction until the transceiver 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

disengages from the socket connector, and then pull the SFP transceiver module straight out 
(Step 2b).  
 

 

Figure 3. SDI to IP coaxial gateway extraction

 

6.

 

Connecting SDI signals to the SDI to IP gateway 

 

Step 1

 

E

nsure that the SFP+ is seated and latched properly. 

Step 2

 

Connect the HD-BNC by pushing the HD-BNC inside the connector (Step 2a), and then 

turn (clockwise) the HD-BNC to lock the cable (Step 2b) as shown in the next figure. 

 

 

 

 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

 

Figure 4. Connecting SDI signals

 

 

Note

 

Supported SDI format as of publication of this manual : 1080p50/59/60, 1080i50/59/60, 

720p50/59/60, 525i59, 625i50. Other rates have not been tested yet.

 

 

 

7.

 

Configuring the SDI to IP gateway by the 10GE network 

 

Note

 

Steps described below are an 

example

 of a possible connection and tool to use to configure 

the 

Gateway SFP

. One may have other solution to connect an application to send JSON commands 

to the 

Gateway SFP

 on the 10GE link.

 

 

 

Step 1

 

Insert the 

Gateway SFP

 into the 10GE host. 

 

At that point, there should be a link established for the 

Gateway

 SFP (status led 

on the 10GE host).  

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

Note

 

 Gateway SFP

 (encapsulator and decapsulator) can take up to 

10sec

 to establish 

the link on cold boot.

 

 

 

Step 2

 

Insert an 1GE RJ45 SFP into the 10GE/1GE equipment. 

Step 3

 

Connect a 1GE-enabled PC to the 1GE RJ45 SFP. 

 

At that point, there should be a link established between the PC and the RJ45 

SFP (status led on the switch). 

Step 4

 

Configure the PC’s Lan Adapter to be on the same subnet as the 

Gateway SFP

 

 

Step 5

 

Using Windows Command Prompt, ping your 

Gateway SFP

 

Encap :

 192.168.39.215 

 

Decap :

 

 

192.168.39.216 

 

Note

 

  Depending  on  the  10GE  equipment  configuration,  it  may  have  traffic  contention  between 

10GE/2022-6 traffic and 1GE/management traffic (for API access). For first tests, we recommend to 
have only management traffic in the 10GE equipment.

 

 

 

Step 6

 

Start 

Firefox HTTP Requester

 (free Mozilla Firefox plugin – 

WINDOWS platform

).  

See  emSFP  Devices 

IP  gateway  REST  API  Userguide.pdf

  document  for  the  complete 

description of readable/writeable information AND for HTTP requester use. 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

Step 7

 

Get 2022-6 configuration from the 

Gateway SFP

  

1.

 

Specify your 

Gateway SFP

 address (or hostname: emsfp-a0-xx-xx, where the xx-xx are 

the last digits of the 

SFP

 MAC address found on the label). 

2.

 

Press 

GET

 button 

 

Command answer will be displayed on the right. 

 

Step 8

 

Change 2022-6 configuration of the 

Gateway SFP

  

1.

 

Specify your 

Gateway SFP

 address (or hostname: emsfp-a0-xx-xx, where the xx-xx are 

the last digits of the 

SFP

 MAC address found on the label). 

2.

 

Press 

GET

 button 

 

Command answer will be displayed on the right. 

3.

 

Copy the answer from the right side to the left side text box 

Content to send

4.

 

Edit the desired values. 

5.

 

Press 

PUT

 button 

 

Note

 

 Shown below is information for decap; encap is a bit different – there is no 

pkt_filter_xyz

 

parameter to manage (item 2 in image below). 

Note

 

 Configuration showed below for 2022-6 traffic is used to build / retrieve the packets so both 

encap and decap should have the same content based on the decap’s 

pkt_filter_xyz

 setting. Shown 

below is 

destination IP address filtering

.

 

 

 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

 

 

8.

 

Updating the SDI to IP gateway (by the internal webpage) 

 

Note

 

Communication with the SFP+ is only feasible if the network is properly configured and the 

computer used to communicate is in the same IP subnet (as shown in previous section).

 

 

 

The 

Gateway SFP

 possesses a webpage to ease update over the network. This intelligent SFP+ 

is  DHCP  ready,  if  a  DHCP  exist,  the  SFP+  will  request  an  IP  address  and  will  request  an 

HOSTNAME in the network. The HOSTNAME is composed like this: 

 

As example an SFP+ gateway with a MAC finishing by 0a-01-dd will have an hostname: emSFP-0a-01-dd

 

 

 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

10 

Step 1

 

Ensure that the link is established between the PC and the 

Gateway SFP

 (see steps 1 to 

7 in previous section). 

Step 2

 

Using Google Chrome on Windows, access the 

Gateway SFP

 webpage 

Type 

http://HOSTNAME (or IP address)/config

 

Step 3

 

Upload and run a new code 

Please refer to the image above. 

To upload a new code: 

1-

 

Choose an empty element and click on “Choose File” (button naming is browser 

dependent). 

2-

 

Browse to and select the provided 

.img

 file. 

3-

 

Click on “Upload”. The upload and verification process will take about 30 seconds. 

If no empty element is available to upload a new code, you can free one by clicking on “Clear” 

and wait until the element is cleared (about 40 seconds). 

If the upload process was successful, CRC value will be shown in green for that particular 

element. If not, it will be shown in red. In the unlikely later case, click on “Clear” and then repeat 

above steps. 

To run a new or existing code: 

1-

 

Click on “Set As Default” to select this code as default when inserting or power cycling 

the SFP+. 

2-

 

Click on “Load Now” and wait until the page reloads. 

3-

 

Running image is the one marked in green (element number background, 0 on the above 

image). 

 


background image

EB22 Family 

IP-SDI gateway SFP+

 

User Guide

 

Document version 0.4 

 

11 

Under some circumstances (slow switch port bring-up time, slow DHCP server response time), 

the loading will take more time and the page will not reload by itself. 

Allow some more time and 

refresh the page manually, up to 1 minute. 

 

Note

 

Do not remove the SFP+ while uploading a new code or clearing an element.

 

 

 

Note

 

It is not possible to clear or upgrade the code located in element labeled “Golden”

This 

ensures that the product will always have a working code to load. 

 

 

9.

 

Troubleshooting the modules 

 

Step 1

If the SFP is accessible for configuration but the video path is not working : 

1.

 

Make sure the 

flows

 configuration matches between encap and decap. 

2.

 

Make sure to disable IGMP snooping. 

3.

 

For decap, make sure that the 

packet filter

 selected is well defined so data from only 

one encap is selected. For example, if filtering on destination IP, make sure that only 

one encap is sending to that specific destination IP.