background image

SERVICE

Vidasýz

Montaj

KK-AS2

0E/060801-2

T:/p/kk/eds/ing/AS2

0eng

5

5

8

8

EDS Elektronik Destek
Sanayi ve Ticaret Ltd. Þti.

Meclis Mah. Teraziciler Cad.
K ý l ý ç S o k . N o : 4 3 4 7 8 5
S a r ý g a z i /

Ý s t a n b u l

www.eds.com.tr eds@eds.com.tr

+90 216 528 45 00
+90 216 314 17 80

Tel.

Fax

:
:

INSTALLATION MANUAL

AS 250

OUTDOOR SOUNDER

 


background image

OUTDOOR SOUNDER

AS 250

2

8

AS 250

13.6VDC
38mA
300-450mA (Audio type is depend on)
102dB-108dB
2.0-4Khz

Selectable (5 min.)
5/15min. selectable
- and +
Single Piezo
Negative/Pozitive selectable
100.000p/Lum
1.000.000
120/min.
Red/Blue
Walking LED
Available
Outdoor
Alarm Panels
ABS Plastic
White,
210x320x80
920gr
-10 C

+50 C

4 selectable

° ~

°

(Audio type is depend on)

6V 280mAH NiCd
Galvanized
2. Piezo

- 12V/1.2ah Vicd

7

8

Figure: 9

AS 250

+12V-

SAB

S

F

Buzzer

Micro

switch

JP1

Flasher Trigger

Siren Trigger

Sabotage

-

+

DC 12

Jp4
Jp3
Jp2

Jp7

Battery

AS 250 Card

Function

Voltage type

Start time set-up

Trigger type

Siren period

Siren supervise time

Jumper

JP 1

JP 2

JP 3

JP 4

JP 7

OFF

SBP is
from panel

-

Negative

5 min.

N: Negative Trigger
P: Pozitive Trigger

ON

SBA is
from battery

5 min

Pozitive

15 min.

Factory Default Values

JP 1 :

OFF

JP 2:

OFF

JP 3:

OFF

JP 4:

OFF

JP 5:

OPEN

JP 6:

OPEN

JP 7:

Negative

OUTDOOR SOUNDER

General

Techinical Specifications

AS 250 Series Outdoor Sounders are aesthetically designed, high quality sounders for outdoor usage.
These products are compatable with all security systems, durable for any kind of weather conditions and
impact.

Sounders are protected with outher plastic material (inner metal cover is optional).

AS 250 Series Sounders are compatable with all alarm panels. Interior tamper key, walking LED display is
available against the tamper and system disorders. The piezo buzzer with extremely high sound level
capacity used for As250 series sounders

AS 250 Series Sounders are designed for screwless installation

Model

Operating voltage
Stand-by current
Alarm current
Voice output
Voice frequency
Audio type

Buzzer
Trigger type
Light output
Flasher life
Flasher frequency
Colour of flasher
LED display
Tamper
Environment
Application
Housing
Colors of housing
Dimensions
Weight
Operating temperature

Programmable siren period
Start time set-up
Siren supervise resistor

Optional Accessory

Battery
Inner cover
Piezo

Connections

Warning & Cautions

Please read the manual before attempting installation or operation

minutes after the strobe stops flashing before removing the cover

WAIT 3

Do not throw into fire

Do not reverse charge

Do not short-circuit

Turn off the power immediately and contact the technician when a problem occurs.

Battery

+-

Jp

6

Jp

5

JP 5

X

X

-

-

JP 6

X

-

X

-

Audio No

Audio 1

Audio 2

Audio 3

Audio 4

X :
- :

Open
Off

 


background image

Mount

1-Turn the siren upside-down to open the cover, push the 'M' latch upwards and pull the cover below.
(Figure 1)

2-Mark the screw holes and suspender places on the wall with the aid of box bottom plastic or template on
the package for mounting. (Figure 2)

3-Set the electricity connections of the card as shown in Electricity Connections/Figure:9 and draw
attention to the sample Panel Connection section.

4-Place the battery to the slot shown in Figure 3. Be careful with the polarities and the direction of the
battery. (a battery, fix it with the cable bound and open-circuit the Jp1)

5-After completing the electricity and battery connections, place the transparent protection cover on the
card. (Figure 4)

Opening The Top Cover Before Mounting

Attaching the Top Cover

Opening The Top Cover After Mounting

3

8

Panel Connections

6

8

GENERAL

S

S

S-

S-

S+

S+

ST8048

CLASSIC

+SİREN-

12

PREMIER 412/816

POS

COM

AUX1

CADDX NX-4/6/8

VERÝTAS 8/8R

S
D
C

A

B

Siren

trigger

Flasher

trigger

-12
V

+

- 12V + SAB

SI

FL

Flasher

Trigger

- 12V + SAB

SI

FL

Siren

Trigger

- 12V + SAB

SI

FL

- 12V + SAB

SI

FL

- 12V + SAB

SI

FL

- 12V + SAB

SI

FL

CADDX NX 4/6/8 AUX1 programmer:

(Prg. input)
(Location(Menu) NO)
(Prg. Output options)
(outrput active 0-.255min.)
(Prg. Output)

* 8 9 7 1 3 0 #

47 #

7 *

max.0 - 255dk

* 46 # 1 * * * EXIT

Flasher

Trigger

Siren

Trigger

Flasher

Trigger

Siren

Trigger

Flasher

Trigger

Siren

Trigger

Flasher

Trigger

Siren

Trigger

Flasher

Trigger

Siren

Trigger

Place the 'A' nails as they would fit into the 'B' holes as shown in Figure:7 and then make the latch be
attached to 'M' point by pressing the top cover.

Push 'M' latch in Figure:7 with a straight screw and lift the top cover. Push the cover upwards to let the
'A' nails release and remove the cover.

Mount the optionally provided metal cover as shown in Figure:8.

Mounting the Metal Cover

1- It should be at least 5cm below the ceiling in order to be able to open the top cover during assembly.
2- Choose a clean and smooth surface for easy mounting.
3- Use 4 units of M4+52 metal screw and M8 dubel(plastic screw holder in-wall)

Important Mounting Notes

OUTDOOR SOUNDER

AS 250

AS 250

OUTDOOR SOUNDER

 


background image

Mount

Mount

4

8

5

8

Figure: 1

Figure: 2

Figure: 3

Figure: 4

Figure: 5

Figure: 6

Figure: 7

AKÜ

A

A

B

B

M

Figure: 8

Mounting The Metal cover

(The metal cover is optional)

Screw

Screw

Screw

Screw

Cable canal

Suspender

OUTDOOR SOUNDER

AS 250

AS 250

OUTDOOR SOUNDER