PDF User Manual

  1. Home
  2. Manuals
  3. Combi-Cam miniK 10 Operating Manual

Combi-Cam miniK 10 Operating Manual

Made by: Combi-Cam
Type: Operating Manual
Category: Door locks
Pages: 8
Size: 0.43 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

OPERATING MANUAL

cabinets               lockers                  carts            

Combi  Cam

-

E

electronic cam lock  

SINGLE USER MODE

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

PROGRAMMING THE MINIK10  

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

GENERAL WARNINGS:

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

 


background image

Page 2

INTRODUCTION:

Combi-Cam E – electronic cabinet lock with master/manager code, one-time-use functionality, and 
up to 10 years battery life.  Combi-Cam E can be installed for both right and 
left hand installations – anywhere that needs flexibility of master/manager 
codes.  The eco-friendly MiniK10 offers both convenience of far less 
frequent battery changes and a more 
environmentally  friendly solution.

PASSWORD LEVELS:

The Combi-Cam E has three potential password levels –
1. User password
2. Service password  (must activate in Program 5.1)
3. Master password
The user and master passwords should be changed prior to installation and tested.  Write down new 
passwords and keep in a safe place.  It is not possible to open lock if you forget your password.

MODES:

The Combi-Cam E can operate in two different modes:
1. Single User (factory default)- Set password and user will open lock each time with same password.
2. Multiple User Locker Mode- user enters in their code when lock is in unlocked position, rotates
     handle to lock.  Upon returning uses same code to open.  Next user can repeat the process with
     their own unique password.

SINGLE USER MODE

OPENING WITH USER PASSWORD:

 

1) Enter your 4-digit user password.  On first 
use factory default is <1-0-1-0>.  
2) Rotate handle within 5 seconds to opening 
direction and there will be a confirmation beep.

CLOSING WITH USER PASSWORD: 

1)Enter your 4-digit user password.  
2) Rotate handle within 5 seconds so that handle 
is toward  warning label that displays lock is closed.  
Lock will give a  warning beep and the green LED 
light will blink. NOTE: Program 6.1 allows lock to be closed without a password.

CHANGING USER PASSWORD:

If  single user mode is selected (default), press      button and enter current 4-digit user 
password.  Press      button again and enter new 4-digit user password.  Press      button again and 
approve new password.  You will get a confirmation beep and green LED light will blink.

vs.

Below illustrations show examples of lock installed for right 
handed door. Lock can be installed for left or right handed.

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

OLD USER               NEW USER

PROGRAMMING THE MINIK10  

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

GENERAL WARNINGS:

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

 


background image

Page 3

SINGLE USER MODE

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

In multiple user mode,  opening and closing with a password process is same as Single User. However, 
each time lock is in open position,  each user can enter in their own unique 4-digit code 
to lock and then open the MiniK10.  Popular application is for gym lockers.

SERVICE PASSWORD

SERVICE PASSWORD

  

By default, service password is not active.  Activate with Program 5.1.  

Service password allows lock to be opened only  and none of lock features can be programmed.

OPENING WITH SERVICE PASSWORD:  

Default - <1-0-1-0-1>

If service password function is active, 1) press      button and enter current 5-digit service password and  
press      button.  2) Rotate handle within 
5 seconds to opening direction.  You 
will get a confirmation beep from lock and 
green LED light will blink.

CHANGING SERVICE PASSWORD:

When you have selected service password in program menu, press      button twice and enter current 
5-digit service password.  Press      button again and enter new 5-digit service password.  Press 
    button again and approve 
new password.  You will get a 
confirmation beep from lock and 
green LED lights will blink.

MASTER PASSWORD

MASTER PASSWORD

 

 

opens lock and grants access to all programming features

OPENING WITH MASTER PASSWORD:

  Default - <1-0-1-0-1-0>

1) Press the      button and enter current 6-digit 
master password and press      button. 2) Rotate 
handle within 5 seconds to opening direction.  
You will get a confirmation beep from lock and 
green LED light will blink.

CLOSING WITH MASTER PASSWORD:

1) Press      button and enter 6-digit master 
password.  Press      button again.  
2) Rotate handle within 5 seconds counter 
clockwise, so handle faces padlock label indicating 
lock is closed.  You will get a confirmation beep from lock.

CHANGING MASTER PASSWORD: 

 Set new master password and test BEFORE installing lock.

Press      button twice, and then enter old 6-digit master password.  Press      button again and 
enter new 6-digit master password.  Press      button again and approve new password.  
You will get a confirmation beep from lock.

SERVICE PASSWORD

OLD SERVICE              NEW SERVICE

   MASTER PASSWORD

   MASTER PASSWORD

OLD MASTER           NEW MASTER

PROGRAMMING THE MINIK10  

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

GENERAL WARNINGS:

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

 


background image

Page 4

SINGLE USER MODE

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

 

 

 

0

 

1

 

 

 

Prg No  1-1:  One -time-use  operation  (Locker mode with multiple users)

 

Prg  No   2-1:  Audible beeps  and confirmations

 

Prg No   3-0:  Penalty operation is not active 
Prg No   4-0:  No function currently assigned

 

Prg No   5-0:  Service password is not active  
Prg No   6-0:  Closing with password required

 

Prg No   7-0:  Warning of open door is not active

 

 

Prg No   8-0:  Resetting user password is not active  
Prg No   9-0:  Blocking of the lock is not active  

1

 

0  

Individual operation  

1  

One -time-use operation  (locker mode for multiple users)

 

2

 

0  

Mute operation except for warnings

 

1  

Audible operation- button feedback, warnings and confirmations

 

3

 

0  

Penalty not active

 

1  

Penalty  

active (lock blocked for 5 minutes if wrong code entered 3 times)

 

4

 

0  

None  

1  

None  

5

 

0  

Service password is not active  

1  

Service password is active

 

6

 

0  

Closing with password is active  

1  

Automatically closing is active (for individual usage)

 

7

 

0  

Warning of door open is not active  

1  

Warning of door open is active (beeps 8 times every 5 seconds)

 

8

 

0  

Resetting user password is not active (if service password is active)

 

1  

Resetting user password is active (if service password is active)

 

9

 

0  

Blocking of the lock is not active (if service password is active)

 

1  

Blocking of the lock is active after using service password (if it is active)

 

 
 

PROGRAMMING THE MINIK10  

The MiniK10 can be customized from factory default settings tailored to your needs.

ACCESSING THE PROGRAM MENU:

Press the      button and then enter the 6-digit master password.  Press the      button. Press the 
program number that you will make an adjustment to, and then press the adjustment selection.

PROG.
NO

SELECTION
NO

MASTER PASSWORD

Program No

Selection No

Explanation:

0-1

  Restores factory default settings:

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

GENERAL WARNINGS:

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

 


background image

Page 5

SINGLE USER MODE

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

PROGRAMMING THE MINIK10  

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

Password is accepted: 

Green LED lights with two repeated audio warnings

Wrong password: 

 

Red LED lights with four repeated audio warnings

Low battery: 

 

Red LED lights blink 5 times after each operation  

Lock is open: 

 

1 minute after door is opened, lock gives audible warning 8 times 

   every 

seconds

MAINTENANCE:

GENERAL WARNINGS:

Restoring factory settings:

  All factory default settings are restored (see 

program menu).  User password becomes <1-0-1-0> and master password 
becomes <1-0-1-0-1-0>. 

Individual Use or Locker Mode:  

Factory default is locker mode (one time 

use) whereby each user that walks up to an open MiniK10 can enter their 4-
digit code to close and open lock.  Every person can enter their own new code 
when lock is in open mode.  Individual use mode allows one 4-digit static code 
to be entered that would remain same code for one user.  

Audible volume control:

  All audio warnings can be turned off if mute 

operation is selected (except warning beeps). 

Penalty operation:

  Prevents tampering of lock by unauthorized people.  Lock 

is blocked for 5 minutes if wrong password is entered three times 
consecutively. Factory default is that this feature is not active. 

This programming function is currently open for placing a future feature

 

Service password:

  Lock can be opened with service password if user 

password is forgotten.  Factory service default password is <1-0-1-0-1>.  No 
programming features can be accessed with service password.  Factory 
default is that this feature is not active. 

Closing modes: 

Factory default is that the MiniK10 requires a password to 

lock.  The other option is it can be locked without requiring a password.   

Door open warning:

  After door is open for one minute, lock gives an audible 

warning to user with 8 beeps every 5 seconds to notify user that the door has 
been left open. 

Resetting user password:

  If the lock is opened with service password (and 

service password is active), user password can be reset.  (see program #5 on 
service passwords). Factory default is that the service password access does 
not allow the user password to be reset (only opens up the lock). 

Blocking the lock:

  If lock opened with service password, it can be blocked

 

from further user password access

.  

This would insure service password is only 

used to access locks for emergency lockouts. Master password access would 
then be required to set up user password again (0-1 Factory default reset).  
Factory default is that this feature is not active.

 

 

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

Lock operates on a 3V lithium coin cell CR2450 battery located on back side of device.  Remove screw 
located on cover of battery and replace it with new battery.   Battery life is up to 10 years.  Th red LED 
light blinks 5 times after each operation when battery is low and it is possible to open and close 
lock for 100-150 times after you get the initial low battery warning.

 


background image

Page 6

SINGLE USER MODE

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

PROGRAMMING THE MINIK10  

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

 

- Clean  front of  lock with a mild damp cloth with detergent if needed.

 

- Do not use any hard or scratching cleanser.

 

- Do not clean with chemical materials that melt plastic (e.g. thinner, acetone, etc.)

 

 -Be careful not to spill water on lock.

GENERAL WARNINGS:

 

- Read manual before using lock.

 

- Set and test user and master passwords prior to installing the lock

 

- Change all default passwords with your own passwords.

 

- Common sense, but we must say it... Do not keep the passwords in the cabinet where 

  

   

the lock is being installed!

 

- It is not possible to open lock if installed and you forget the user and master password.

 

- Lock gives a warning beep when passwords are old or have not been entered excessively.

 

- Not possible for front side of lock to be opened by breaking or trying to force open lock.

 

- Use CR2450 3.0V Lithium batteries.

 

- Remember that battery consumption is high when programs 2, 3, and 7 are active.

 

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

Installation instructions??
-  Cam placement,
-  Stop Cam
-  Template for screw hole?
-  Template for routing out?
-  Optional Cams available?
-  What about metal semiflush mount?  Is there a bracket available?

 


background image

Combi  Cam

-

E

NOTE:
These are default 
settings by the 
factory.  Once they 
are changed, be 
sure to right down
your new code ! 

QUICK INFO

SINGLE USER MODE

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

PROGRAMMING THE MINIK10  

Page 7

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

GENERAL WARNINGS:

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

CHANGING THE BATTERY:

Opening direction varies according to type of door MiniK10 is installed.
All opening illustrations depict right handed door installation.

 


background image

18424 HWY 99
Lynnwood WA 98037

www.fjmsecurity.com

Toll Free:  800-654-1786
Fax:            206-350-1186

F J M

Security Products

Innovative, Quality Security Solutions

Page 8

SINGLE USER MODE

eco-friendly 

electronic lock

Combi   Cam

-

E

Batteries don’t just grow on trees you know!  

Install Green

For more detailed instructions and
video demos, go to www.combi-cam/E/

MULTIPLE USER MODE (LOCKER MODE / ONE TIME USE MODE)

SERVICE PASSWORD

  

MASTER PASSWORD

 

 

PROGRAMMING THE MINIK10  

NOTE: 

 Remember to write down your passwords after programming and prior to 

installing lock.  It is not possible to open lock if it is installed and you forget your passwords.

Battery: 

3.0V Lithium CR 2450 

Key Pad: 

Silicone Keypad 

Operating Temperature: 

-5 / 55 C 

Storage Temperature: 

-10 / +70 C 

Operating Moisture: 

20 – 80% Rh (without condensation) 

 

TECHNICAL SPECIFICATIONS:

LIGHT AND AUDIO NOTIFICATION:

MAINTENANCE:

GENERAL WARNINGS:

PROGRAMMING OPTION DEFINITIONS:

OTHER PRODUCTS IN THE COMBI-CAM FAMILY:   

www.combi-cam.com

CHANGING THE BATTERY: