1

Product Data

355BAV Preferred

t

Plus 95i

95% AFUE Upflow Only Variable--Speed

Condensing Gas Furnace

Series C, Input Rates 60,000 thru 120,000 Btuh

A05085

Building

on

our

industry--leading

condensing

furnace

technology, the model 355BAV is our greatest innovation in

comfort control and operating efficiency.
Modern technology provides the Plus 95i

t

design with great

reliability, high efficiency, and ultra--quiet operation. Efficiencies
are above 95 percent Annual Fuel Utilization Efficiency (AFUE).

The model 355BAV Plus 95i

t

Condensing Gas Furnace

incorporates our patented Perfect Heat

t

Control. This control

interacts with a 2--stage gas valve, a variable--speed inducer

motor, and a variable--speed blower motor, allowing the Plus
95i

t

to adjust combustion air, firing rate, and airflow to maintain

peak efficiency throughout the operating cycle.
The Perfect Heat

t

system provides the ultimate in heating

comfort while minimizing electrical and gas consumption. The

Plus 95i also features Perfect Humidity control when combined
with a Bryant Thermidistat

t

Control and air conditioner or heat

pump system.
For even greater comfort and convenience, match the Plus 95i

furnace with a two--speed heat pump to create a HYBRID
HEAT

®

Dual Fuel system.

FEATURES

Perfect Heat

t

/Perfect Humidity

t

Control

—This intelligent

heating control constantly monitors operating conditions to adjust
for greater efficiency and comfort. The control operates 90% of

the time in low--heat and reserves the high--firing rate for times

when the heating demand is high. The Perfect Heat/Perfect
Humidity control has these additional features:

S

dedicated terminals for electrical connection of electronic air
cleaner and humidifier

S

adjustable blower off time

S

LED fault code display to aid in servicing

S

selectable airflow to match cooling unit

S

emergency heat setting

S

setting to increase airflow for bypass--type humidifier

S

selectable constant fan airflow

S

a multi--zone setting for use with zoned air distribution

systems a special dehumidification function increases cooling
comfort by providing greater humidity removal in summer

months

S

controls humidity even when there is no heating or cooling
demand

Three--Pass

Primary

Heat

Exchangers

—This

design

accelerates heat transfer and extracts heat that conventional heat
exchangers waste up the flue. The primary heat exchanger is

made of aluminized steel for corrosion resistance.

Flow--Through Secondary Heat Exchangers

—Each cell is

laminated with our patented Everlastic

t

polypropylene for

greater resistance to corrosion and is epoxy coated externally to

prevent oxidation. This breakthrough in heating technology
(Patent No. 4,738,307) helps extend the life of the furnace for

years of reliable performance. The heat exchangers are positioned
in the furnace to extract additional heat from the combustion

products regardless of furnace orientation.

Perfect Light

t

Igniter

—Bryant’s unique SiN igniter is not only

physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage

regulators as do other brands. This unique feature further
enhances the reliability of Bryant’s 355BAV gas furnace and

continues Bryant’s tradition of technology leadership and

innovation in providing a reliable and durable product.

Fan On Plus

t

—Improves comfort all year long by allowing

you to select the continuous fan speed right at the thermostat.

SmartEvap

t

—Allows your system to reduce summertime

humidity levels by nearly 10% over standard systems.

 


background image

2

Upflow Only Design

—Allows the model 355BAV to be installed

in an upflow orientation only. Factory configured for upflow

applications. The model 355BAV is available in 5 heat/airflow
combinations.

Direct Venting

—This furnace can be installed as a 2--pipe/Direct

vent furnace.

2--Stage Gas Valve

—The 355BAV has a 2--stage gas valve to

vary the amount of gas being used from low--heat to high--heat
stage.

Fully--Insulated Casing

—Foil--faced insulation in the heat

exchanger section cuts the heat loss; double--density insulation in

the blower section reduces noise levels. The casing also has the
required openings for left-- or right--side connection of gas,

electric, drain, and vent connections.

Variable--Speed Motors

—Variable--speed operation improves

the comfort levels in the home. Variable--Speed motors are also
more economical to operate than standard motors. They have the

ability to adapt to changing conditions and provide consistent,

comfortable, and quiet heating. Motors and electronic controls are
covered by a 5--year limited warranty.

Sealed Combustion System

—This furnace brings in combustion

air from outside the furnace, which results in especially quiet

operation.

Monoport Inshot Burners

—Produce precise air--to--gas mixture

for clean burning. The large monoport on the inshot or injection

type burners seldom, if ever, needs cleaning.

Quality Registration

—The 355BAV is engineered and

manufactured under an ISO 9001 registered quality system.

Certifications

—The 355BAV units are CSA (A.G.A. and

C.G.A.) design certified for use with natural and propane gases,

as well as AHRI efficiency rating certified. The furnace is factory
shipped for use with natural gas. An CSA (A.G.A. and C.G.A.)

certified gas conversion kit is required to convert furnace for use

with propane gas. The model 355BAV meets California Air
Quality Management District emission requirements.

D E

S I G N

C

E R

T I F I E

D

CERTIFIED

Always Ask For

Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.  For
verification of certification for individual products,
go to www.ahridirectory.org.

355B

A

V

 


background image

3

DIMENSIONS

NO TES: 

1. Minimum retur n-air openings at fur nace , based on metal duct.  If fle x duct is used, 

see fle x duct manuf acturerí s recommendations f or equiv alent diameters . 

2. Minimum retur n-air opening at fur nace: 

a. F or 800 CFM–16-in. (406mm)  round or 14 

 (368 mm)x 12-in. (305 mm)  rectangle 

b. F or 1200 CFM–20-in. (508mm)  round or 14 

 (368mm)x 19 

-in.  (495mm) rectangle 

c. F or 1600 CFM–22-in. (559mm)  round or 14 

 (368mm)x 23 

-in. (591mm) rectangle 

d. F or airflo w requirements abo v e 1800 CFM, see Air Deliv er y  tab le in Product Data 

literature f or specific use of single side inlets .  The use of both side inlets , a 

combination of 1 side and the bottom, or the bottom only will ensure adequate 

retur n air openings f or airflo w requirements abo v e 1800 CFM . 

17  

16 

24  

27  

16 

TYP 

27  

29  

11 

16 

TYP 

30  

13 

16 

32  

TYP 

33  

TYP 

CONDENSA TE 

DRAIN  TRAP 

LOCA TION 

(AL TERNA TE 

UPFL OW ) 

-IN .  DI A (22mm) 

A CCESSOR Y 

PO WER ENT RY 

-IN .  DI A (22mm) 

PO WER CONN 

CONDENSA TE DRAI N 

TRAP LOCA TION 

(DO WNFLO W  & 

HORIZONT AL LEFT ) 

26  

15 

16 

24  

22  

16 

2-IN .  (51 mm) COMBUSTION- 

AIR CONN 

-IN . (13mm) DI A 

GAS CONN 

2-IN (51mm) 

.  

VENT CONN 

-IN .  DIA (13mm)  

THERMOST AT ENT RY 

22  

11 

16 

SIDE INLE T 

23  

"  

TYP 

SIDE INLE T 

OUTLET 

26  

15 

16 

28   

22  

16 

19 

13 

16 

16 

39  

22  

"  

TYP 

11 

16 

16 

24  

16 

BO TT OM INLE T 

18   

22  

11 

16 

2-IN .  (51mm)  

 

COMBUSTION-AIR CONN 

-IN .  DI A (13mm) 

GAS CONN 

-IN .  DI A (22mm) 

PO WER CONN 

-IN .  DI A (13 mm) 

THERMOS TA T  ENTR Y 

2-IN .  (51 mm) 

VENT CONN 

DIMPLE LOCA T ORS 

FOR HORIZONT AL 

HANGING 

14  

TYP 

SIDE INLE T 

9  

16 

TYP 

26  

15 

16 

"  

TYP 

CONDENSA TE 

DRAIN LOCA TIO N 

(UPFLO W) 

30  

16 

TYP 

CONDENSA TE 

DRAIN LOCA TION 

(UPFL OW ) 

INLE T 

11 

16 

11 

16 

13 

16 

13 

16 

OUTLET 

AIRFL OW 

26  

26  

CONDENSA TE DRAI N 

TRAP LOCA TION 

(DO WNFL OW   & 

HORIZONT AL RIGHT) 

OR AL TERNA TE 

-IN .  DIA GAS CONN 

(684 mm) 

(667 mm) 

(622 mm) 

(567 mm) 

(368 mm) 

(32 mm) 

(25mm) 

(591 mm) 

(684 mm) 

(240 mm) 

(439 mm) 

(622 mm) 

(700 mm) 

(702 mm) 

(754 mm) 

(783 mm) 

(829 mm) 

(845 mm) 

(21 mm) 

(17 mm) 

(17 mm) 

(21 mm) 

(775 mm) 

(464 mm) 

(14 mm) 

(614 mm) 

(565 mm) 

(576 mm) 

(483 mm) 

(567 mm) 

(667 mm) 

(684 mm) 

(724 mm) 

(21 mm) 

(16 mm) 

(16 mm) 

(1013 mm) 

(25 mm) 

(11 mm) 

(25 mm)

(576 mm)

A05124

Dimensions -- In. (mm)

UNIT SIZE

A

D

E

060---14 / 042060

17---1/2 / 445

15---7/8 / 403

16 / 406

080---14 / 042080

21 / 533

19---3/8 / 492

19---1/2 / 495

080---20 / 060080

21 / 533

19---3/8 / 492

19---1/2 / 495

100---20 / 060100

21 / 533

19---3/8 / 492

19---1/2 / 495

120---20 / 060120

24---1/2 / 622

22---7/8 / 581

23 / 584

X

A92505

Heat Exchangers

Control Center

A02286

Inducer Assembly

ACRDJ  AIR 

CONDITIONING 

RELAY DISABLE 

JUMPER

HUMIDIFIER 

TERMINAL (24-VAC 

0.5 AMP MAX. 

CONTINUOUS FAN 

(CF) AIRFLOW 

SETUP SWITCHES

 

CONNECTOR  

AIR CONDITIONING 

(A/C) AIRFLOW 

SETUP SWITCHES 

MODEL PLUG 
CONNECTOR 

SW1 SETUP 

SWITCHES AND 

BLOWER OFF-

DELAY 

STATUS AND COMM 

LED LIGHTS  

3-AMP FUSE  

TRANSFORMER 24-VAC 

CONNECTIONS  

PL3 ECM BLOWER

HARNESS 

CONNECTOR  

PL1 LOW  VOLTAGE MAIN

HARNESS CONNECTOR  

EAC-1 TERMINAL 

(115-VAC 1.0 AMP MAX.) 

115-VAC (L1) LINE 

VOLTAGE  CONNECTIONS  

115-VAC (L2) NEUTRAL 

CONNECTIONS  

PL2  HOT SURFACE 
IGNITER & INDUCER 

MOTOR CONNECTOR

24-V THERMOSTAT 

TERMINALS 

DATE CODE XXXXN

FACTORY TEST

A09679

A06450

355B

A

V

 


background image

4

PHYSICAL DATA

DESCRIPTION

UNIT SIZE

042060

042080

060080

060100

060120

Direct---Drive Motor Hp (ECM)

1/2

1/2

1

1

1

Motor Full Load Amps

7.7

7.7

12.8

12.8

12.8

RPM (Nominal)—Speeds

Variable 250 — 1300

Blower Wheel Diameter X Width (in.)

10 X 7

11 X 10

11 X 10

11 X 10

11 X 10

Filter Size (in.) Nominal A (Washable)

(1) 16 X 25 X 1 (1) 20 X 25 X 1 (1) 20 X 25 X 1 (1) 20 X 25 X 1 (1) 24 X 25 X 1

Shipping Weight (lb)

170

182

204

203

234

Limit Control

SPST

Heating Blower Control (Off Delay)

Selectable 90, 120, 150, or 180 SEC Intervals

Burners (Monoport)

3

4

4

5

6

Gas Connection Size

1/2---in. NPT

Gas Valve (Redundant) Manufacturer

Minimum Inlet Pressure (in. wc)

Maximum Inlet Pressure (in. wc)

White---Rodgers

4.5 (Natural Gas)

13.6 (Natural Gas)

Ignition Device

Hot Surface ---SiN

PERFORMANCE DATA

DESCRIPTION

UNIT SIZE

042060

042080

060080

060100

060120

Certified Temp Rise Range (

_

F)

Low

40—70

40—70

40—70

40—70

40—70

High

35—65

40—70

35—65

45—75

45—75

Certified Ext Static Pressure (ESP) (in. wc)

Heating

0.12

0.15

0.15

0.20

0.20

Cooling

0.50

0.50

0.50

0.50

0.50

Airflow CFM*

Heating Low

635 (700

{

)

860 (945

{

)

880 (970

{

)

1105 (1215

{

) 1325 (1455

{

)

Heating High

1070

1245

1490

1525

1900

Cooling (Max)

1400

1372

1975

1950

2060

Output Capacity Btuh

}

(ICS)

Low

37,000

50,000

50,000

63,000

75,000

High

56,000

75,000

75,000

94,000

113,000

AFUE%

}

95.0

95.0

95.0

95.0

95.0

Input Btuh**

Low

39,000

52,000

52,000

65,000

78,000

High

60,000

80,000

80,000

100,000

120,000

* Airflow shown is for bottom only return---air supply with factory---supplied 1---in. washable filter(s). For air delivery above 1800 CFM, see Air Delivery table for

other options.

{

Low heat CFM when low---heat rise adjustment switch (SW1---3) on furnace control is used.

}

AFUE and capacity in accordance with U.S. Government DOE test procedures.

** Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate

the unit 5% for elevations from 2000 to 4500 ft above sea level.

355B

A

V

 


background image

5

ELECTRICAL DATA

UNIT SIZE

042060

042080

060080

060100

060120

Unit Volts---Hertz---Phase

115---60---1

Operating Voltage Range (Min---Max)*

104---127

Maximum Unit Amps

8.9

8.9

13.8

13.8

13.8

Minimum Wire Size

14

14

12

12

12

Maxium Wire Length (ft)

{

31

31

32

32

32

Maximum Fuse or Ckt Brk (Amps)

}

15

15

20

20

20

Transformer (24v)

40va

External Control Power Available

Heating

25va

Cooling

34va

* Permissible limits of the voltage range at which the unit will operate satisfactorily.

{

Length shown is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.

}

Time---delay type is recommended.

BRYANT ACCESSORIES

DESCRIPTION

PART NO.

UNIT SIZE

042060

042080

060080

060100

060120

Vent Termination Kit (Bracket Only for 2 Pipes)

2---in. — KGAVT0101BRA
3---in. — KGAVT0201BRA

X

X

X

X

X

Concentric Termination Kit (Single Exit)

2---in. — KGAVT0701CVT
3---in. — KGAVT0801CVT

X

X

X

X

X

Condensate Freeze Protection Kit

KGAHT0101CFP

X

X

X

X

X

Germicidal Air Purifier

Model GAPA

X

X

X

X

X

Condensate Neutralizer Kit (obtained thru RCD)

P908---0001

X

X

X

X

X

Electronic Air Cleaner

Model EACA

X

X

X

X

X

Mechanical Air Cleaner

Model FILCAB or

EZXCAB

X

X

X

X

X

Humidifier

Model HUM

X

X

X

X

X

Heat Recovery Ventilator

Model HRV

X

X

X

X

X

Energy Recovery Ventilator

Model ERV

X

X

X

X

X

UV Lights

Model UVL

X

X

X

X

X

EZ Flex Media Filter with end caps --- 16---in. (9 pack)

EXPXXLMC0016

X

EZ Flex Media Filter with end caps --- 20---in. (9 pack)

EXPXXLMC0020

X

X

X

EZ Flex Media Filter with end caps --- 24---in. (6 pack)

EXPXXLMC0024

X

Replacement EZ Flex Filter --- 16---in. (10 pack)

EXPXXFIL0016

X

Replacement EZ Flex Filter --- 20---in. (10 pack)

EXPXXFIL0020

X

X

X

Replacement EZ Flex Filter --- 24---in. (10 pack)

EXPXXFIL0024

X

Exterior Filter Rack --- Universal, 1---in. (adjustable from 14---in. to
24---in.) with filter

KGAFR0301ALL
KGAFR0306ALL (6 pack)

X

X

X

X

Unframed Filter 1---in. — 16 x 25

KGAWF1301UFR
KGAWF1306UFR (6 pack)

X

S

S

S

Unframed Filter 1---in. — 20 x 25

KGAWF1401UFR
KGAWF1406UFR (6 pack)

X

X

X

Unframed Filter 1---in. — 24 x 25

KGAWF1501UFR
KGAWF1506UFR (6 pack)

X

355B

A

V

 


background image

6

BRYANT ACCESSORIES (CONTINUED)

DESCRIPTION

PART NO.

UNIT SIZE

042060

042080

060080

060100

060120

Natural---To---Propane Gas Conversion Kit (Single Kit)*

KGANP4601ALL

X

X

X

X

X

Propane---To---Natural Gas Conversion Kit (Single Kit)

KGAPN3901ALL

X

X

X

X

X

ECM Motor Simulator (simulates the ECM blower and inducer

motor to aid troubleshooting)

KGASD0301FMS

X

X

X

X

X

Door Gasket Kit

KGBAC0110DGK

X

X

X

X

X

Advanced Product Monitor (software and hardware to link pc

laptop to control board)

KGAFP0301APM

X

X

X

X

X

ECM Control Replacement Module --- 1/2 HP

HK44EA123

X

X

ECM Control Replacement Module --- 1 HP

HK52EA123

X

X

X

Gas Orifice Kit Size 42 (Qty 50)

KGAHA0150N42

See Installation Instructions for model, altitude,

and heat value usages.

Gas Orifice Kit Size 43 (Qty 50)

KGAHA0250N43

Gas Orifice Kit Size 44 (Qty 50)

KGAHA0350N44

Gas Orifice Kit Size 45 (Qty 50)

KGAHA0450N45

Gas Orifice Kit Size 46 (Qty 50)

KGAHA0550N46

Gas Orifice Kit Size 47 (Qty 50)

KGAHA1550N47

Gas Orifice Kit Size 48 (Qty 50)

KGAHA850N48

Gas Orifice Kit Size 54 (Qty 50)

KGAHA0850P54

Gas Orifice Kit Size 55 (Qty 50)

KGAHA0750P55

Gas Orifice Kit Size 56 (Qty 50)

KGAHA0850P56

Gas Orifice Kit Size 1.25mm (Qty 50)

KGAHA05750125

Gas Orifice Kit Size 1.30mm (Qty 50)

KGAHA5750130

* Factory---authorized and field---installed. Gas conversion kits are CSA (AGA/CGA) recognized.
S --- 16 x 25 filters suitable for side return on all furnace sizes.

355B

A

V

 


background image

7

THERMOSTAT AND ZONING CONTROL OPTIONS

NON---PROGRAMMABLE THERMOSTAT SELECTION

T6---NAC or T2---NAC

For use with 1 speed Air Conditioner ---

_

F/

_

C, Auto Changeover

T6---NHC or T2---NHC

For use with 1 speed Air Conditioner ---

_

F/

_

C, Auto Changeover

T2---NRH*

For use with 2 speed Air Conditioner ---

_

F/

_

C, Auto Changeover

* Model HP & 2 Stage thermostat must be field converted to air conditioner operation.

PROGRAMMABLE THERMOSTAT SELECTION

T2---PAC

For use with 1 speed Air Conditioner ---

_

F/

_

C, Auto Changeover, 7---Day

Programmable

T2---PHP*

For use with 1 speed Heat Pump ---

_

F/

_

C, Auto Changeover, 7---Day

Programmable

T2---PRH*

For use with 2 speed Air Conditioner ---

_

F/

_

C, Auto Changeover, 7---Day

Programmable

T2---PAC

For use with 1 speed Air Conditioner ---

_

F/

_

C, Auto Changeover, 5---2

Programmable

T2---PRH

{

For use with two---stage applications ---

_

F/

_

C, Auto Changeover, 7---Day

Programmable

T2---PRH

}

For multi---use/stage configurations ---

_

F/

_

C, Auto Changeover 7---Day

Programmable

* Model HP & 2 Stage thermostat must be field converted to air conditioner operation.

{

Hybrid Heat Dual Fuel system thermostat is used with furnace and heat pump application.

}

Thermidistat can be configured multiple use and staging. It must be configured for each specific application.

ZONING CONTROL SELECTION

ZONEBB3Z(AC/HP)01

Comfort Series Three---Zone Zone Kit

ZONEBB2KIT01---B

2---Performance Series Zoning/Temperature and Humidity Control

ZONEBB4KIT01---B

4---Performance Series Zoning/Temperature and Humidity Control

ZONEBB8KIT01---B

8---Performance Series Zoning/Temperature and Humidity Control

355B

A

V

 


background image

8

AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)*

Unit Size

Operating Mode

CFM Airflow

Setting

External Static

Pressure Range*

External Static Pressure (ESP) In. W.C.

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

042060

††

Low Heat

635†

0---0.50

635

635

625

615

615

High Heat

1070†

0---1.0

1070 1070 1070 1070 1070 1070 1070 1070 1065 1045

††

1---1/2---Ton A/C Cooling

525

0---0.50‡

525

525

510

495

465

††

2---Ton A/C Cooling

700

0---0.50‡

700

700

695

680

680

2---1/2---Ton A/C Cooling

875

0---1.0‡

850

870

875

875

870

860

845

825

810

805

3---Ton A/C Cooling

1050

0---1.0

1050 1050 1050 1050 1050 1050 1050 1050 1050 1045

3---1/2---Ton A/C Cooling

1225

0---1.0

1225 1225 1225 1225 1225 1225 1225 1225 1225 1205

Maximum

1400

0---1.0

1400 1400 1400 1400 1400 1400 1400 1400 1380 1325

042080***

††

Low Heat

900†

0---0.50

860

870

880

885

885

880

870

855

850

845

High Heat

1245†

0---1.0

1245 1245 1245 1245 1245 1245 1245 1235 1190 1145

††

1---1/2---Ton A/C Cooling

525

0---0.50‡

515

495

490

475

465

††

2---Ton A/C Cooling

700

0---0.50‡

685

680

670

665

665

2---1/2---Ton A/C Cooling

875

0---1.0‡

830

840

850

860

860

855

840

830

825

820

3---Ton A/C Cooling

1050

0---1.0‡

1050 1050 1050 1050 1050 1045 1040 1025 1015 1000

3---1/2---Ton A/C Cooling

1225

0---1.0‡

1225 1225 1225 1225 1225 1225 1225 1225 1185 1140

Maximum

1400

0---1.0‡

1400 1400 1400 1400 1375 1325 1280 1235 1190 1145

060080***

††

Low Heat

880†

0---0.50

880

880

880

875

880

High Heat

1500†

0---1.0

1485 1495 1500 1500 1500 1500 1500 1485 1475 1465

††

2---Ton A/C Cooling

700

0---0.50‡

670

640

635

630

630

††

2---1/2---Ton A/C Cooling

875

0---0.50‡

870

875

865

865

865

3---Ton A/C Cooling

1050

0---1.0‡

1050 1045 1040 1045 1045 1050 1050 1050 1045 1040

3---1/2---Ton A/C Cooling

1225

0---1.0‡

1225 1225 1225 1225 1225 1225 1225 1225 1225 1225

4---Ton A/C Cooling

1400

0---1.0‡

1330 1345 1360 1375 1380 1380 1380 1370 1365 1355

5---Ton A/C Cooling

1750

0---1.0

1750 1750 1750 1750 1750 1750 1745 1725 1700 1685

Maximum

2000

0---1.0

2000 2000 2000 2000 1975 1955 1920 1870 1820 1770

060100***

††

Low Heat

1110†

0---0.50

1105 1110 1110 1110 1110 1110 1110 1110 1110 1110

High Heat

1525†

0---1.0

1525 1525 1525 1525 1525 1525 1525 1510 1495 1470

††

2---Ton A/C Cooling

700

0---0.50‡

700

690

690

690

690

††

2---1/2---Ton A/C Cooling

875

0---0.50‡

835

845

855

860

865

3---Ton A/C Cooling

1050

0---1.0‡

1050 1050 1050 1050 1050 1050 1050 1050 1050 1050

3---1/2---Ton A/C Cooling

1225

0---1.0‡

1170 1190 1205 1220 1225 1225 1225 1225 1225 1225

4---Ton A/C Cooling

1400

0---1.0‡

1400 1400 1400 1400 1400 1400 1400 1400 1400 1375

5---Ton A/C Cooling

1750

0---1.0

1735 1740 1735 1735 1725 1720 1710 1695 1680 1660

Maximum

2000

0---1.0

1995 1985 1980 1965 1950 1935 1910 1885 1860 1815

060120

Low Heat

1330†

0---1.0

1325 1330 1330 1330 1330 1330 1330 1330 1330 1325

High Heat

1900†

0---1.0

1900 1900 1900 1900 1900 1885 1875 1860 1840 1815

††

2---Ton A/C Cooling

700

0---0.50‡

700

700

700

700

695

††

2---1/2---Ton A/C Cooling

875

0---0.50‡

870

875

875

865

870

3---Ton A/C Cooling

1050

0---1.0‡

1025 1035 1045 1050 1050 1050 1050 1050 1040 1025

3---1/2---Ton A/C Cooling

1225

0---1.0‡

1210 1210 1210 1225 1225 1225 1225 1225 1225 1225

4---Ton A/C Cooling

1400

0---1.0‡

1385 1400 1400 1400 1400 1400 1400 1395 1375 1370

5---Ton A/C Cooling

1750

0---1.0‡

1745 1730 1735 1735 1740 1735 1730 1725 1710 1685

6---Ton A/C Cooling

2100

0---1.0

2100 2100 2080 2065 2060 2045 2030 2000 1960 1895

Maximum

2100

0---1.0

2100 2100 2080 2065 2060 2045 2030 2000 1960 1895

* Actual external static pressure (ESP) can be determined by using the fan laws (CFM

2

proportional to ESP); such as, a system with 1750 CFM at 0.5 ESP

would operate at high---heating airflow of 1500 CFM at 0.37 ESP and low---heating airflow of 880 CFM at 0.13 ESP.

{

All heating CFMs are when low---heat rise adjustment switch (SW1---3) and comfort/efficiency adjustment switch (SW1---4) are OFF.

}

Ductwork must be sized for high---heating CFM within the operational range of ESP.

** Wattage data provided is for the circulating blower with bottom return and does not include draft inducer, accessories, or gas controls.

{{

Operation within the blank areas of the chart is not recommended because high---heat operation will be above 1.0 ESP.

*** All airflows on 21 in. casing size furnaces are 5% less on side return only installations.

355B

A

V

 


background image

9

MAXIMUM ALLOWABLE PIPE LENGTH (FT / M)

Direct Vent (2---Pipe Only)

NUMBER OF 90

_

ELBOWS

UNIT SIZE

(BTUH)

ALTITUDE

Termination

Type

Pipe Dia

(IN.)*

1

2

3

4

5

6

60,000

0 to 2000

2 Pipe or 2---In.

Concentric

1---1/2

50 / 15.2

45 / 13.7

40 / 12.9

35 / 10.7

30 / 9.1

25 / 7.6

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

80,000

2 Pipe or 2---In.

Concentric

1---1/2

30 / 9.14

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

100,000

2 Pipe or 2---In.

Concentric

2

45 / 13.7

40 / 12.9

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

2---1/2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

120,000

2 Pipe or 3---In.

Concentric

2---1/2 one

disk

10 / 3.0

NA

NA

NA

NA

NA

3 one disk

35 / 10.7

30 / 9.1

15 / 4.8

NA

NA

NA

3 one disk†

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

UNIT SIZE

(BTUH)

ALTITUDE

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

60,000

2001 to

3000

2 Pipe or 2---In.

Concentric

1---1/2

45 / 13.7

40 / 12.9

35 / 10.7

30 / 9.14

25 / 7.6

20 / 6.1

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

80,000

2 Pipe or 2---In.

Concentric

1---1/2

26 / 7.9

21 / 6.4

16 / 4.9

11 / 3.4

6 / 1.8

NA

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

100,000

2 Pipe or 2---In.

Concentric

2

40 / 12.2

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

15 / 4.6

2---1/2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

120,000

2 Pipe or 3---In.

Concentric

3 one disk

31 / 9.4

26 / 7.9

12 / 3.7

NA

NA

NA

3 one disk†

63 / 19.2

62 / 18.9

62 / 18.9

61 / 18.6

61 / 18.6

61 / 18.6

UNIT SIZE

(BTUH)

ALTITUDE

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

60,000

3001 to

4000

2 Pipe or 2---In.

Concentric

1---1/2

42 / 12.8

37 / 11.2

32 / 9.8

27 / 8.2

22 / 6.7

17 / 5.2

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

80,000

2 Pipe or 2---In.

Concentric

1---1/2

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

NA

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

100,000

2 Pipe or 2---In.

Concentric

2

38 / 11.6

33 / 10.1

28 / 8.5

23 / 7.0

18 / 5.5

13 / 4.0

2---1/2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

120,000

2 Pipe or 3---In.

Concentric

3 one disk

29 / 8.8

24 / 7.3

10 / 3.0

NA

NA

NA

3 one disk†

59 / 18.0

59 / 18.0

58 / 17.8

57 / 17.4

57 / 17.4

56 / 17.0

UNIT SIZE

(BTUH)

ALTITUDE

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

60,000

4001 to

5000‡

2 Pipe or 2---In.

Concentric

1---1/2

40 / 12.2

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

15 / 9.6

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

80,000

2 Pipe or 2---In.

Concentric

1---1/2

23 / 7.0

18 / 5.5

13 / 4.0

8 / 2.4

NA

NA

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

68 / 20.7

100,000

2 Pipe or 2---In.

Concentric

2

36 / 11.0

31 / 9.4

26 / 7.9

21 / 6.4

16 / 4.8

11 / 3.4

2---1/2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

120,000

2 Pipe or 3---In.

Concentric

3 one disk†

56 / 17.1

55 / 16.8

54 / 16.5

53 / 6.2

52 / 15.8

52 / 15.8

UNIT SIZE

(BTUH)

ALTITUDE

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

60,000

5001 to

6000‡

2 Pipe or 2---In.

Concentric

1---1/2

37 / 11.3

32 / 9.8

27 / 8.2

22 / 6.7

17 / 5.2

12 / 3.7

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

80,000

2 Pipe or 2---In.

Concentric

1---1/2

22 / 6.7

17 / 5.2

12 / 3.7

7 / 2.1

NA

NA

2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

68 / 20.7

63 / 19.2

100,000

2 Pipe or 2---In.

Concentric

2

33 / 10

28 / 8.5

23 / 7.0

18 / 5.5

13 / 4.0

8 / 2.4

2---1/2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

120,000

2 Pipe or 3---In.

Concentric

3 one disk†

53 / 16.2

52 / 15.8

50 / 15.2

49 / 14.9

48 / 14.6

47 / 14.3

*See notes on next page.

355B

A

V

 


background image

10

MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) (CONTINUED)

ALTITUDE

UNIT SIZE

(BTUH)

Direct Vent (2--Pipe Only)

NUMBER OF 90

_

ELBOWS

Termination

Type

Pipe Dia

(IN.)*

1

2

3

4

5

6

6001 to 7000‡

60,000

2 Pipe or 2---In.

Concentric

1---1/2

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

2

70 / 21.3

70 / 21.3

68 / 20.7

67 / 20.4

66 / 20.11

64 / 19.5

80,000

2 Pipe or 2---In.

Concentric

1---1/2

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

NA

NA

2

70 / 21.3

70 / 21.3

68 / 20.7

67 / 20.4

62 / 18.9

57 / 17.4

100,000

2 Pipe or 2---In.

Concentric

2

31 / 9.4

26 / 7.9

21 / 6.4

16 / 4.9

11 / 3.4

6 / 1.8

2---1/2

70 / 21.3

70 / 21.3

68 / 20.7

67 / 20.4

66 / 20.1

64 / 19.5

120,000

2 Pipe or 3---In.

Concentric

3 one disk†

49 / 14.9

48 / 14.6

47 / 14.3

45 / 13.7

44 / 13.4

43 / 13.1

ALTITUDE

UNIT SIZE

(BTUH)

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

7001 to 8000‡

60,000

2 Pipe or 2---In.

Concentric

1---1/2

32 / 9.8

27 / 8.2

22 / 6.7

17 / 5.2

12 / 3.7

7 / 2.1

2

66 /20.1

65 / 19.8

63 / 19.2

62 / 18.9

60 / 18.3

59 / 18.0

80,000

2 Pipe or 2---In.

Concentric

1---1/2

18 / 5.5

13 / 4.0

8 / 2.4

NA

NA

NA

2

66 / 20.1

65 / 19.8

63 / 19.2

62 / 18.9

57 / 17.4

52 / 15.8

100,000

2 Pipe or 2---In.

Concentric

2

29 / 8.8

24 / 7.3

19 / 5.8

14 / 4.3

9 / 2.7

NA

2---1/2

66 / 20.1

65 / 19.8

63 / 19.2

62 / 18.9

60 / 18.3

59 / 18

120,000

2 Pipe or 3---In.

Concentric

3 one disk†

46 / 14.0

44 / 13.4

43 / 13.1

41 / 12.5

40 / 12.2

38 / 11.6

ALTITUDE

UNIT SIZE

(BTUH)

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

8001 to 9000‡

60,000

2 Pipe or 2---In.

Concentric

1---1/2

30 / 9.1

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

2

62 / 18.9

60 / 17.8

58 / 17.7

56 / 17.1

55 / 16.8

53 / 16.2

80,000

2 Pipe or 2---In.

Concentric

1---1/2

17 / 5.2

12 / 3.1

7 / 2.1

NA

NA

NA

2

62 / 18.9

60 / 18.3

58 / 17.7

56 / 17.1

51 / 15.5

46 / 14.0

100,000

2 Pipe or 2---In.

Concentric

2

27 / 8.2

22 / 6.7

17 / 5.2

12 / 3.7

7 / 2.1

NA

2---1/2

62 / 18.9

60 / 18.3

58 / 17.7

56 / 17.1

55 / 16.8

53 / 16.2

120,000

2 Pipe or 3---In.

Concentric

3 one disk†

43 / 13.1

41 / 12.5

39 /11.9

37 / 11.3

35 / 10.7

34 / 10.4

ALTITUDE

UNIT SIZE

(BTUH)

Termination

Type

Pipe Dia

(IN.)*

NUMBER OF 90

_

ELBOWS

1

2

3

4

5

6

9001 to

10000‡

60,000

2 Pipe or 2---In.

Concentric

1---1/2

27 / 8.2

22 / 6.7

17 / 5.2

12 / 3.7

7 / 2.1

NA

2

57 / 17.4

55 / 16.8

53 / 16.2

51 / 15.5

49 / 14.9

47 / 14.3

80,000

2 Pipe or 2---In.

Concentric

1---1/2

15 / 4.6

10 / 3.0

5 / 1.5

NA

NA

NA

2

57 / 17.4

55 / 16.8

53 / 16.2

51 / 15.5

46 / 14.0

41 / 12.5

100,000

2 Pipe or 2---In.

Concentric

2

24 / 7.3

19 / 5.8

14 / 4.3

9 / 2.7

NA

NA

2---1/2

57 / 17.4

55 / 16.8

53 / 16.2

51 / 15.5

49 / 14.9

47 / 14.3

120,000

2 Pipe or 3---In.

Concentric

3 one disk†

39 / 11.9

37 / 11.3

35 / 10.7

33 / 10.1

31 / 9.5

29 / 8.8

* Disk usage---Unless otherwise stated, use perforated disk assembly (factory---supplied in loose parts bag).

{

Wide radius elbow.

}

Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction.

NA---Not Allowed; pressure switch will not make.

NOTES:

1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.

2. Size both the combustion---air and vent pipe independently, determine the smallest diameter allowed by the table for each pipe, then use the larger diameter for both pipes.

3. Assume two 45

_

elbows equal one 90

_

elbow. Long radius elbows are desirable and may be required in some cases.

4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.

5. The minimum pipe length is 5 ft for all applications.

355B

A

V

 


background image

11

MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT / M) WITH

INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*

UNIT SIZE

WINTER DESIGN

MAXIMUM PIPE DI-

INSULATION THICKNESS†

TEMPERATURE

AMETER (IN.)

0

3/8

1/2

3/4

1

042060

20

_

F / ---6.7

_

C

2

30 / 9.1

55 / 16.8

61 / 18.6

70 / 21.3

70 / 21.3

0

_

F / ---17.8

_

C

2

16 / 4.9

33 / 10.1

38 / 11.6

46 / 14.0

53 / 16.2

---20

_

F / ---28.9

_

C

2

9 / 2.7

23 / 7.0

26 / 7.9

33 / 10.1

38 / 11.6

042080

060080

20

_

F / ---6.7

_

C

2

37 / 11.2

65 / 19.8

70 / 21.4

70 / 21.3

70 / 21.3

0

_

F / ---17.8

_

C

2

20 / 6.1

39 / 11.9

45 / 13.7

55 / 16.8

63 / 19.2

---20

_

F / ---28.9

_

C

2

11 / 3.4

27 / 8.3

31 / 9.4

39 / 11.9

45 / 13.7

060100

20

_

F / ---6.7

_

C

2---1/2

41 / 12.5

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

0

_

F / ---17.8

_

C

2---1/2

21 / 6.4

42 / 12.8

48 / 14.6

59 / 18.0

68 / 20.7

---20

_

F / ---28.9

_

C

2---1/2

11 / 3.4

28 / 8.5

33 / 10.1

41 / 12.5

49 / 14.9

060120

20

_

F / ---6.7

_

C

3

49 / 14.9

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

0

_

F / ---17.8

_

C

3

26 / 7.9

51 / 15.5

58 / 17.7

70 / 21.3

70 /21.3

---20

_

F / ---28.9

_

C

3

15 / 4.6

35 / 10.7

40 / 12.2

50 / 15.2

59 / 18.0

* Pipe length (ft/m) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable

pipe length as specified in Table.

Insulation thickness based on R value of 3.5 per in.

CONCENTRIC VENT (DIRECT VENT/2--PIPE ONLY) (ALL MODEL SIZES)

C IN. DIA

B IN. DIA PVC

VENT/EXHAUST

1

3

/

16

B IN. DIA PVC

INTAKE/COMBUSTION AIR

D

E

F

A

1

1/2

A97110

Dimensions (in.)

KIT PART NO.

A*

B

C

D

{

E

F

KGAVT0701CVT

33---3/8

2

3---1/2

16---5/8

6---1/4

5---3/4

KGAVT0801CVT

38---7/8

3

4---1/2

21---1/8

7---3/8

6---1/2

* Dimension A will change proportionally as dimension D is lengthened or shortened.

{

Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. minimum.

355B

A

V

 


background image

12

CONDENSATE TRAP

CONDENSATE
TRAP (INSIDE)

BLOWER SHELF

ALTERNATE DRAIN
TUBE LOCATION

UPFLOW APPLICATIONS

CONDENSATE TRAP

DRAIN TUBE LOCATION

A06519

TYPICAL WIRING SCHEMATIC

115-VOLT FIELD-

SUPPLIED

FUSED

DISCONNECT   

JUNCTION

BOX   

CONTROL

BOX

24-VOLT

TERMINAL

BLOCK  

THREE-WIRE

HEATING-

ONLY   

FIVE

WIRE

   

NOTE 2

NOTE 1

1-STAGE

THERMOSTAT

TERMINALS

   

FIELD-SUPPLIED

FUSED DISCONNECT

CONDENSING

UNIT   

FURNACE

COM

R

 

W

C

Y

R

G

GND   

GND   

FIELD 24-VOLT WIRING

FIELD 115-, 208/230-, 460-VOLT WIRING

FACTORY 24-VOLT WIRING

FACTORY 115-VOLT WIRING   

Connect Y/Y2-terminal as shown for proper operation.

Some thermostats require a "C" terminal connection as shown.

If any of the original wire, as supplied, must be replaced, use

same type or equivalent wire.

208/230- OR

460-VOLT

THREE

PHASE   

208/230-

VOLT

SINGLE

PHASE   

WHT   

BLK   

WHT   

BLK   

A95236

W/W1

W2

Y/Y2

G

NOTES:

1.

2.

3.

A95236

355B

A

V

 


background image

13

CLEARANCE TO COMBUSTIBLES

                                                                               

  (LIT. TOP)

A09681

TYPICAL INSTALLATIONS

COMBUSTION AIR PIPE

A/C COIL

OUTDOOR UNIT

VENT PIPE

HUMIDIFIER

GAS-FIRED

WATER HEATER

ELECTRONIC

AIR CLEANER

AIRFLOW

FRONT OF

FURNACE

A06511

355B

A

V

 


background image

14

GUIDE SPECIFICATIONS

General

System Description

Furnish a ______________________ (upflow) gas--fired

condensing furnace for use with natural gas or propane (factory--
authorized conversion kit required for propane); furnish cold air

return plenum; furnish external media cabinet for use with

accessory media filter or standard filter.

Quality Assurance

Unit will be designed, tested and constructed to the current ANSI

Z 21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.

Unit will carry the CSA Blue Star

R

and Blue Flame

R

labels.

Unit efficiency testing will be performed per the current DOE test

procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest GAMA Consumer’s Directory of Certified Efficiency

Ratings.
Unit will carry the current Federal Trade Commission Energy

Guide efficiency label.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available upon

request.

Equipment

Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and

dynamically balanced. Blower motor of ECM type shall be

permanently lubricated with sealed ball bearings, of _______hp,
and have infinitely variable speed from 300--1300 RPM

operating only when 24--VAC motor inputs are provided. Blower
motor shall be direct drive and soft mounted to the blower scroll

to reduce vibration transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.

(X) ________ in. An accessory highly efficient Media Filter is
available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted
galvanized steel.

Preferred

t

Plus 95i

Two--Stage/Variable Speed Gas Furnace

355BAV

ECM Inducer Motor
ECM Inducer motor shall be variable speed design, soft mounted
to assembly to reduce vibration transmission.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass 20 gauge corrosion--

resistant aluminized steel of fold--and--crimp sectional design and

applied operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a flow--through design
having a patented interior laminate coating of polypropylene for

greater corrosion resistance with fold--and--crimp design and

applied operating under negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting

codes displayed via diagnostic flashing LED light on the control,
a self--test feature that checks all major functions of the furnace,

and a replaceable automotive--type circuit protection fuse.

Multiple operational settings available, including separate blower
speeds for low heat, high heat, low cooling, high cooling and

continuous fan. Continuous fan speed may be adjusted from the
thermostat. Cooling airflow will be selectable between 350 or 400

CFM per ton of air conditioning. Features will also include

temporary reduced airflow in the cooling mode for improved
dehumidification when a Thermidistat is selected as the

thermostat.

Operating Characteristics

Heating capacity shall be _________________ Btuh input;

______________ Btuh output capacity.
Fuel Gas Efficiency shall be 95% AFUE.
Air delivery shall be ________________ cfm minimum at 0.50

in. wc. external static pressure.
Dimensions shall be: depth_________in.; width __________in.;

height___________in. (casing only). Height shall be

_________in. with A/C coil and _________________in. overall
with plenum.

Electrical Requirements

Electrical supply shall be 115 volts, 60 Hz, single--phase
(nominal). Minimum wire size shall be ________AWG;

maximum fuse size of HACR--type designated circuit breaker
shall be _________ amps.

Special Features

Refer to section of the product data identifying accessories and

descriptions for specific features and available enhancements.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

E

Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 09/10

Replaces: PDS355B.40.1

Catalog No. PDS355B.40.2

355B

A

V