DCN Next Generation Release 4.41 

Table of Contents 

1

 

This release Contains

 ........................................................................................................ 2

 

2

 

Improved and added Functionality

 .................................................................................. 2

 

3

 

Release Compatibility Restrictions

 .................................................................................. 6

 

4

 

Software, Firmware & FPGA versions

 ............................................................................. 7

 

5

 

Additional Information to the DCN Manuals and Help Files

 .......................................... 9

 

6

 

Trouble Shootings and known issues

 ............................................................................. 9

 

 

 

1

 

This release Contains 

The following versions are part of this release: 

Product 

version 

DCN-SW 

4.41 

DCN-SWSMV 

4.40 

DCN-SWSACC 

4.40 

DCN-SWWA 

1.11 

DCN-DLT (CCU2) 

4.41 

DCN-CCU2 

4.41 

HdCameraControl 

4.40 

DCN-DLT (CCU, NCO) 

3.10 

DCN-CCU 

3.10 

 

2

 

Improved and added Functionality 

Release  Release 

Date 

Release Comments 

4.41 

2014-11-02 

New functionality and improvements 

 

Improved DCN wireless firmware to make it more robust in 

environments with a lot of WiFi communication

 

 

Unresponsive microphone control in Operator application due 

to network disconnections

 

 

Added DCN-SW icons to DVD

 

 


background image

DCN Next Generation Release Notes

 

en | 3 

                                                   

 

Bosch Security Systems| 2014-10-31 

Release  Release 

Date 

Release Comments 

4.40 

2014-07-30 

New functionality and improvements 

 

Added Notebooker configuration to the API and 

DcnApiDemonstrator

 

 

Added AGC on/off to audio outputs of Audio Expander in 

Individual Channels mode

 

 

DCN-CCU2 supports Omneo Media Interface to interface with 

DCN multimedia

 

 

Added Mongolian to Concentus display

 

 

ID cards can be programmed via API with and without CRC

 

 

Insert and remove of ID card can be executed via API to enable 

interfacing with third party identification system

 

 

Windows 8.1 support for DCN-SW

 

 

Windows 8.1 support for DCN-SWSMV

 

 

Windows 8.1 support for DCN-SWSACC

 

 

Windows 8.1 support for HdCameraControl

 

 

Added Crystal Reports installer to Tools directory. This needs 

to be installed to print the voting reports from DCN-SWSMV.

 

 
Note 

 

Windows Vista is no longer supported for DCN-SW, DCN-

SWSMV, DCN-SWSACC, HdCameraControl

 

4.30 

2014-01-31 

New functionality and improvements 

 

DcnHdCameraControl added second video switcher Kramer 

MV-6

 

 

DcnHdCameraControl made screen line configurable

 

 

DcnHdCameraControl added camera transition time

 

 

added create groups, rename meetings, rename sessions, 

request list via API (DCN-SWAPI) including demonstrator 

application with source code.

 

Fixes 

 

Increased the vote description from 50 to 130 characters.

 

 

Indivual voting results not translated.

 

4.21 

2013-09-30 

Fixes 

 

Multi channel and multi lingual DCN-SWWA (version 1.1.1) 
added. 

 

Russian helpfile missing in DCN-SW.

 

 

Previous DCN-SW version cannot be upgraded because 

database of previous DCN-SW version cannot be upgraded.

 

 


background image

DCN Next Generation Release Notes

 

en | 4 

                                                   

 

Bosch Security Systems| 2014-10-31 

Release  Release 

Date 

Release Comments 

4.20 

2013-07-15 

New functionality and improvements 

 

DCN-SW added Opinion Poll and Audience Response 

(requires DCN-SWMV multi voting license)

 

 

Select, Summon, Start, Hold, Stop of votings via API (DCN-

SWAPI) including demonstrator application with source code.

 

 

DCN-SW copy vote and copy session added to Configuration 

Application and API to improve usability

 

 

Master Volume Control and Chairman Priority added to Control 

API.

 

 

Added Vietnamese and Indonesian language to DCN-SW, 

DCN-SWSMV and DCN-SWSACC

 

 

Added get and set System ID for slave CCU’s to Open 

Interface

 

 

Response list length increased from 5 to max 25 and made 

configurable on CCU and via DCN-SW

 

 

Number of Open Microphones (NOM) increased from 4 to 25.

 

 

Number of seats which can be added to the Notebook 

increased from 15 to 25.

 

 

Increased Operator Application target size

 

 

Added group speech timers to DCN-SWSMD (and 

DcnSmdDemonstrator application)

 

 

Added show last minute of speech by blinking microphone LED

 

 

Added a new audio routing option to the CCU: Insert no AGC.

 

Fixes 

 

DCN-SW added Czech, language to the installer.

 

 

Show OI connection on CCU

 

 

Solved inconsistencies in showing voting results

 

 

Solved SMD error regarding loss of speaker information when 

chairman speaks and ID cards and speechtimers are used.

 

 

Voting control on desktop does not show graphs for group 

results

 

 


background image

DCN Next Generation Release Notes

 

en | 5 

                                                   

 

Bosch Security Systems| 2014-10-31 

Release  Release 

Date 

Release Comments 

4.10 

2013-04-17 

New functionality and improvements 

 

Start/Stop Meeting and Session and Microphone Management 

control via API (DCN-SWAPI) including demonstrator 

application with source code.

 

 

Control of the IDesk outgoing channel using DCN Operator 

Application (requires DCN-SWSI license).

 

 

DCN-SW added Voice Activated Microphone Logging to 

identify which microphone is active in VOICE mode (requires 

DCN-SWVAML license). Can be used in combination with 

camera control to see who is speaking is voice mode.

 

 

DCN-SW font colour below icons on layout can be changed.

 

 

DCN-SW Meeting can be copied (including all settings) using 

Configuration Application and API.

 

 

Demonstrator application including source code for DCN-

SWSMD XML streaming meeting data.

 

 

HD Camera Control via DCN-SWSMD streaming meeting data.

 

 

DCN-SW added Czech language to the GUI. Czech language 

has to be copied manually, please refer to the Tools\Language\ 

directory.

 

 

Extended the explanation about the TCP connection in Open 

Interface description.

 

 

DCN-SWWA Webcast application added. Only English User 
interface. Only one audio-channel/language. 

Fixes 

 

DCN-SWSMD information regarding microphone on off.

 

 

DCN-SWSMD information empty when session name and 

description are identical.

 

 

Stopping an Operator-control session does not clear request 

list.

 

 

DCN-MR wave form and audio sometimes not in sync.

 

 

DCN-SW not all GUI texts fit.

 

 

DCN-SWSMV Reset microphone sensitivity ALL 

MICROPHONES.

 

 

DCN-CCU2 can cause acoustic feedback when powered up in 

Insertion mode.

 

 

DCN-SW added Slovenian language to GUI. Made Japanese 

helpfile part of the installer. Added Thai, Polish and Finnish 

language to the installer.

 

 

DCN-SWSMD Participant is made absent when Chairman 

speaks in Operator with response mode.

 

 

Quorum shows strange behaviour with ID-cards and Secret 

voting.

 

 

Performance and stability improvements on DCN SW Server 

and Operator Control

 

 

Delegate names are not shown in speakerlist when using 

access control for voting only.

 

4.03 

2012-07-15 

Fixes 

 

DCN-SW Operator Application can cause a fault pop up upon 

user login and start session.

 

 

DCN-SW Configurator Application can cause a fault pop up 

when a document will be inserted with a file name that is too 

long.

 

 

DCN-SW Printing Application will not start up in Spanish, 

Catalan, Portuguese and Polish.

 

4.02 

2012-04-16 

Fixes 

 

Inserting or withdrawing of ID-cards could lead to fault pop up.

 

 


background image

DCN Next Generation Release Notes

 

en | 6 

                                                   

 

Bosch Security Systems| 2014-10-31 

Release  Release 

Date 

Release Comments 

4.01 

2012-03-01 

Fixes 

 

Auto-relay is always activated when the B-output channel is 

selected (Using DCN-SW with DCN-SWSI).

 

4.00 

2011-12-02 

 

DCN-CCU2 replaces DCN-CCU, DCN-WCCU and DCN-NCO 

 

DCN-CCUB2 replaces DCN-CCUB 

3.10 

2011-07-26 

New functionality and improvements

 

 

Simultaneous Interpretation DCN-SWSI added

 

 

Usher call and speak slowly requests support DCN-SWMD

 

 

DCN-SW GUI languages: de, ca, en, es, fr, hu, it, jp, ko, lt, nl, 
no, pt, ru, sv, zh-chs

 

 

DCN-SW help files languages: de, en, es, fr, it, nl, zh-chs

 

 

Seat assignment and seat definition improved

 

 

DCN-SWSACC indicates when DCN-SWSACC licenses is 

missing. 

 

3

 

Release Compatibility Restrictions 

The following versions are compatible with this release: 

Product 

Hw 

FPGA 

SW 

FW 

DCN-CCU2 

 

na 

na 

4.4x 

DCN-CCU 

 

1.07 

-- 

3.1x 

DCN-CCU in multi CCU mode 

>=5.0 

>=2.17 

 

-- 

DCN-NCO 

 

 

 

 

LBB 4120/00 Interpreter desk 

 

>=1.2 

-- 

-- 

Toggle in DCN-IDESK 

 

 

>=1.40.xxxx   

 

The following applications are compatible with this release: 

Product 

Hw 

FPGA 

SW 

FW 

DCN-SW 

 

4.00.3959 

4.40 

4.40 

DCN-SWSMV 

 

 

4.40 

 

DCN-SWSACC 

 

 

4.40 

 

DCN-MR 

 

 

2.0 

 

Download and License Tool 

 

 

4.40 

 

DCN-SWWA 

 

 

1.10 

 

HdCameraControl 

 

 

4.40 

 

Optical devices 

 

 

 

5.02 

 

DCN-SWSMV: exporting voting results to PowerPoint is only supported for PowerPoint 2003.  

DCN-SWWA requires DCN-CCU(B)2. 

 

Wireless Units: 

New firmware is developed for the DCN Wireless units to operate with the DCN-CCU2 (e.g. 

encryption functionality). This firmware can be uploaded using the Download and License Tool 

(DLT) and the Upgrade Toolkit (DCN-UPTK). This firmware works with DCN-CCU2 and DCN-

WCCU. 

 

Products with the following hardware version have already this firmware installed. 

 

Product 

Hw 

DCN-WD-D 

02/04 

DCN-WDD-D 

02/04 

DCN-WDV-D 

02/04 

DCN-WDCS-D 

02/05 

DCN-WDDCS-D 

02/05 

DCN-WDVCS-D 

02/05 

 

 


background image

DCN Next Generation Release Notes

 

en | 7 

                                                   

 

Bosch Security Systems| 2014-10-31 

4

 

Software, Firmware & FPGA versions 

The table below provides a versions overview of parts which cannot be downloaded using the 

Download and License Tool or the DCN-UPTK Wireless upgrade Tool kit. 

Please contact your local Bosch representative how to update these parts. 

 

The HW column indicates if the Hardware Version of the product is supported for the listed parts. 

 

For product which cannot show the FPGA version, the HW version belonging to the FPGA version 

is shown between brackets after the FPGA version. 

 

DCN-CCU & DCN-WCCU 

FPGA 

HW 

Fixes 

2.23  

≥ 4.0  Slow reacting Multi CCU system 

2.22 

≥ 4.0  Noise or no audio on delegate loudspeaker 

2.20 

≥ 4.0  Unstable system after start-up due to optical network disturbances 

2.19 

≥ 4.0  Noise on delegate loudspeaker 

2.18 

≥ 4.0  Unexpected beeps on delegate loudspeaker fixed 

 

DCN-CCUB 

FPGA 

HW 

Fixes 

1.22 

≥ 1.0  Noise or no audio on delegate loudspeaker 

1.09 

≥ 1.0  Noise on delegate loudspeaker 

1.08 

≥ 1.0  Unexpected beeps on delegate loudspeaker 

 

DCN-CONxx range 

FPGA 

HW 

Fixes / Additions 

1.17 (hw1.12) 

≥ 1.0  Address might be lost after system restart 

1.14 (hw1.10) 

≥ 1.0  11Khz noise 

SW 

 

 

1.10.xxxx (hw1.13)  ≥ 1.0  CRC check added for ID-cards 

 

DCN-DDI 

FPGA 

HW 

Fixes  / Additions 

2.2 (hw02.01) 

≥ 1.0  11Khz noise 

2.0 (hw02.00) 

≥ 1.0  CRC check added for ID-cards 

 

DCN-DIS range 

FPGA 

HW 

Problem fixed 

1.20 (hw02.06) 

≥ 1.0  11Khz noise 

1.18 (hw02.03) 

≥ 1.0  Disturbed audio on headphones for channels > 28 

Address might be lost after system restart 

1.15 

≥ 1.0  Channel auto increment equal to DCN-CON 

1.13 (hw02.02) 

≥ 1.0  Audio distorted on headphones 

 

DCN-FCS 

FPGA 

HW 

Fixes 

2.7 (hw02.02) 

≥ 2.0  11Khz noise 

 

DCN-IDESK 

FPGA 

HW 

Fixes / Additions 

2.1 

≥ 2.0  11Khz noise 

SW 

 

 

1.41.xxxx 

≥ 1.0  loudspeaker symbol might be shown in front of the quality indicator 

after leaving the Idesk’s installation menu 

1.40.xxxx 

≥ 1.0  B Toggle added 

 

INT-TX Range 

 


background image

DCN Next Generation Release Notes

 

en | 8 

                                                   

 

Bosch Security Systems| 2014-10-31 

FPGA 

HW 

Fixes / Additions 

02.03 

≥ 1.0  The display might show unexpected characters 

02.02 

≥ 1.0  Improved stability when used in combination with the DCN system 

02.01 

≥ 1.0  Improved stability when used in combination with the DCN system 

02.00 

≥ 1.0  Initial version 

 


background image

DCN Next Generation Release Notes

 

en | 9 

                                                   

 

Bosch Security Systems| 2014-10-31 

5

 

Additional Information to the DCN Manuals and Help 

Files 

Reference 

What 

DCN-SW 

When installing DCN-SW on a Windows 7 PC you might get the following 

notification: 

 

 

This is because within the time installer checks for framework, SQLServer 

installation starts which prompt for the framework installation. 

Please press OK, after this the framework will be installed from the DCN-SW 

installer and DCN-SW installation will install successful. 

Wireless 

Discussion 

Units 

Wireless Discussion Units which are produced before 2012 need to be upgraded 

using the DCN-UPTK and DLT (4.xx) in order to operate with a DCN-CCU2. 

DCN-

SWSMV 

Showing voting results in PowerPoint 

In case PowerPoint is used to show the voting result, it might happen that 

PowerPoint starts and overlaps the user interface of DCN-SWSMV completely. 

Use the Windows task bar to select DCN-SWSMV again. 

DCN-

SWSMV 

Printing voting results 

To print voting results, Crystal Reports needs to be installed. It is located in the 

Tools directory of the DVD. 

 

6

 

Trouble Shootings and known issues 

This trouble shootings and known issues are in addition to chapter 2 and to the trouble shooting 

chapter in the user manuals. 

Product/function 

Problem 

Solution 

DCN-SW 

Configuration 

Application 

In rare occasions it 

can happen that the 

application closes 

unintended. 

Restart the DCN-SW Configuration Application. 

DCN-SW rinting 

individual voting 

results manually 

Individual voting 

results are not printed 

when printed 

manually via Bosch 

DCN SW Print 

Application. 

Change the voting template accordingly: 

1.

 

Check the “Automatic print after stop of the 

voting” checkbox.  

2.

 

Change the settings to Total, groups and 

individuals.  

3.

 

Uncheck “Automatic print after stop of the 

voting” checkbox. 

DCN-SW multi PC 

Client cannot connect 
with Server when 
multiple network 
adapters are available 

Configure the adapter settings in such a way that the 

network adapter which is used for DCN NG is the 

highest in the list of connections in Adapters and 

Bindings 

DCN-SW 

Delegate both in 

Request to speak as 

Request to respond 

list. 

If a delegate is both in the Request to Respond as in 

the Request to Speak list and you want to shift the 

Request to Speak to Speaking, first cancel the 

Request to Respond. 

 


background image

DCN Next Generation Release Notes

 

en | 10 

                                                   

 

Bosch Security Systems| 2014-10-31 

Product/function 

Problem 

Solution 

DCN-SW 

On 64-bit operating 

systems, it might 

difficult to find 

previous SQL-server 

during DCN-SW 

installation, when 

initial SQL-installation 

was not default. 

During installation of DCN-SW the installation process 

might not be able to find the previous SQL-server, in 

case during initial installation another name for the 

SQL-server was created, instead of using the default 

name. Therefore it is recommended to use the default 

name and folder during initial SQL-installation.  If a 

SQL-server with a non-default name needs to be 

found, the correct name should be entered manually 

in the applicable box during DCN-SW installation. 

DCN-SW 

System overview 

does not show all 

connected devices 

when system is still 

powering up. 

Wait until DCN-system is powered up completely and 

then check the connected devices via DCN-SW 

configuration application VIEW \ System Overview. 

DCN-SW 

DCN-SW Master 

Volume is different 

from CCU volume 

control 

When the Master Volume of the CCU has been 

changed while DCN-SW was disconnected, the DCN-

SW Master Volume will not reflect the CCU-setting. 

Changing the DCN-SW volume setting, will make 

them identical again. 

DCN-SW 

Downgrade to 

versions <3.10 not 

possible. 

Manually uninstall SWL server 2008. 

Note that the DCN-SW database (the database 

contains all settings like seats, meetings, synoptic 

layouts, etc.) will always be removed during a 

downgrade. 

DCN-SW 

Unexpected 

behaviour or no 

reaction of DCN-SW. 

Due to Windows Automatic Updates some critical 

components like SQL Server Express might be 

temporarily not available for DCN-SW. 

Do not set Automatic Updates to Automatic or restart 

your system after the Automatic updates have been 

installed. 

DCN-SW  

Generates errors after 

Windows Stand by.. 

Disable Stand by functionality in the Windows 

operating system. 

DCN-SWPV 

Secret mode does not 

work in ad-hoc voting 

Update to version 2.80 or higher 

DCN-SWPV 

 

Voting attention tone 

cannot be changed 

during a running 

meeting. 

The voting attention tone can be changed in the 

voting template but becomes effective after a vote has 

been selected or started. 

DCN-SW setup 

repair 

Error code 2869 or 

Fatal error during 

installation. 

Remove DCN-SW with DCN-SW setup and make a 

new installation. Settings are stored in the SQL-

database and can be re-used in the new installation. 

DCN-SWSMV 

Error notification upon 
closing DCN-SWSMV 
directly after opening 
it. 

 

Please wait at least 10 seconds to close DCN-

SWSMV after opening it. 

DCN-SWSMV help 

file 

When opening help 

file you get an error. 

Just close the error notification. 

DCN-SWSMV 

DCN-SWSMV will not 

start 

Voting legends cannot be changed into “Not Voted”. 

Remove “BCPCSettings.xml” which can be found: 

For XP: 

“…\Documents and Settings\All Users\Application 

Data\Bosch\DCN Synoptic Microphone and Voting 

Software\x.xx” 

For Vista: 

“…\Programdata\Bosch\DCN Synoptic Microphone 

and Voting Software\x.xx” 

 


background image

DCN Next Generation Release Notes

 

en | 11 

                                                   

 

Bosch Security Systems| 2014-10-31 

Product/function 

Problem 

Solution 

DCN-SWWA 

Does not work with 
DCN-SW 

DCN-SWWA 1.1.1 requires DCN-SW 4.2x or later 

DCN-SWWA 1.0.1 requires DCN-SW 4.1x 

DCN-SWWA 

Webcast will stop 
after 12 hours. 

Maximum webcast length of a webcast is 12 hours. It 

will stop automatically. 

DCN-SWWA 

No audio on SDI input 
box 

With setup, please note if there is no audio, resetting 

the Audio to SDI box most of the time will solve the 

problem. 

DCN-SWWA 

Opinion Poll and 
Multiple Choice 
information from 
DCN-SWSMD is not 
supported. 

none 

DCN-SWWAEC 

Slave languages not 
added after using 
Refresh function. 

Refresh webcast will only effect PowerPoint slides. 

Load webcast will add the languages 

DCN-SWWAEC 

Webcast will not start 
on slave PC’s. 

Close the publisher on slave PC’s before starting a 

new webcast. 

Not all text is 

shown on 

Webcasting player 

For security reasons, 
all text between the 
signs ‘<’and ‘>’ is 
removed and currently 
not shown on the 
webcasting player 
website. 

Do not use the “<” and “>” characters in DCN-SW 

(e.g. meeting information, session information, voting 

information, delegate names) or Webcast Planner 

Website. 

Wireless system in 

combination with 

Integrus 

No audio on DCN 
wireless units when 
powering up DCN-
CCU2 and Integrus 
transmitter 
simultaneous. 

First power up the DCN-CCU2. After it is powered up, 

power up the Integrus transmitter. 

Not able to 

download DCN-

CCU2 firmware 

DCN-DLT is not able 

to download the 

firmware of the CCU 

Check if the DCN-SW server is not running: 

1.

 

Exit the DCN-DLT program 

2.

 

Check if the DCN-CCU2 does not report PC 

on it’s display. If it does Stop the DCN-SW 

server via Start\ <Search programs and files> 

SERVICES. Services (local). And check if PC 

disappears. 

3.

 

Start DCN-DLT (PC will now re-appear in the 

CCU2 screen, but that is correct) and start 

the download. 

If the download still fails, do the following: 

1.

 

Power off and open the DCN-CCU2 

2.

 

Set switch 8 of S600 to ON and power on the 

CCU. 

3.

 

Download the CCU using the DCN-DLT. 

4.

 

After a succesfull download, power off the 

CCU, set switch 8 of S600 to OFF again and 

power on the CCU. 

HD Conference 

Dome 

The HD Conference 

Dome will show an 

incorrect name & 

picture combination if 

a new pre-position is 

asked before it 

reaches it’s pre-

position. 

Do not activate another microphone until the HD 

Conference Dome has reached it’s pre-position. 

DCN-UPTK 

The type of the unit 

connected to the 

UPTK is not valid. 

This notification can occur when the DCN-UPTK unit 

is used extensively. Please replace the connection 

cable. 

 


background image

DCN Next Generation Release Notes

 

en | 12 

                                                   

 

Bosch Security Systems| 2014-10-31 

Product/function 

Problem 

Solution 

DCN-CCU(B)2 

Error relays activated 

upon system reset or 

firmware download. 

During a firmware download or system reset, the 

system is not in normal operation and thus the error 

relays can be active. 

DCN-CONFF and 

DCN-CONCM 

DNPV answers in 

voting are not visible 

in the Concentus 

screen when a voting 

timer is activated. 

Use a hall display or disable the voting timer. 

DCN-SWSACC 

and Allegiant 

Double screenlines 

are still visible on 

audience screens 

after switching to 

single screenlines. 

Restart the Allegiant. 

DCN-SWSACC 

Upload does not work 

anymore. 

Restart the DCN-CCU or DCN-NCO. 

DCN-MR 

DCN-MR does not 

connect to DCN-SW 

when installed on 

another PC 

1.

 

Open the Meeting Recorder.ini file with notepad 

it is located here: C:\Users\[USER 

NAME]\AppData\Roaming\Meeting Recorder 

if the user name is administrator, the path will 

be: C:\Users\ 

Administrator\AppData\Roaming\Meeting 

Recorder 

2.

 

Find the variable NCO Ip=x.x.x.x (where x.x.x.x is 

the IP address of DCN SW server) and below that 

line; 

Create a line DCO Ip=x.x.x.x (where x.x.x.x is the 

IP address of the DCN SW server) 

NCO Port=20000 
NCO Ip=10.120.22.230 

DCO Ip=10.120.22.230

 

CCU Ip=192.168.1.1

 

3.

 

Save the Meeting Recorder.ini file 

 

 

 

DCN-MR 

Windows audio 

playback is lost after 

installation DCN-MR 

1.3. in windows XP. 

Replace files msacm32.drv, msadp32.acm and 

imaadp32.acm in the windows system32 folder. 

Multi CCU systems  System reaction is 

(very) slow after 

system startup. 

The system might become (very) slow when in a multi 

CCU system only the NCO is switched off and the 

rest of the system stays switched on. 

To prevent this problem: 

Shutdown all optical devices in the Multi-CCU system. 

 


background image

DCN Next Generation Release Notes

 

en | 13 

                                                   

 

Bosch Security Systems| 2014-10-31 

Product/function 

Problem 

Solution 

DCN-NCO 

DCN-NCO cannot be 

downgraded or 

upgraded. 

A known issue is that DCN-NCO cannot be 

downgraded from SW 2.70. 

 

Workaround 

1)

 

Install the Download and License Tool of the 

version you want to use to downgrade or upgrade 

to. 

2)

 

Open Notepad and paste the text below into 

Notepad 

 

user target password 

cd /rfa 

dele PDSDATA1.PDS 

dele PDSDATA2.PDS 

bin 

hash 

cd /rfa/drv 

put mmu_3.bit 

put mif_3.bit 

cd /bim 

put dune.bim 

bye 

 

3)

 

Save the file in Notepad to C:\Program 

Files\Bosch\Digital Congress Network\Download 

and License Tool\Files with name dcn-nco.txt 

4)

 

Switch off the NCO and set dipswitch 1 of S3 to 

on, set all other switches to off 

5)

 

Switch on the NCO 

6)

 

Open a command prompt (start -> run -> cmd) 

and change to the following folder: C:\Program 

Files\Bosch\Digital Congress Network\Download 

and License Tool\Files 

7)

 

Download the NCO with the next command line 

FTP with the command: 

ftp -n -s:dcn-nco.txt x.x.x.x  

Where x.x.x.x is the IP-address of the NCO 

8)

 

Switch off the NCO and set the dipswitches all to 

off 

9)

 

Switch on the NCO 

10)

 

Start the Download and License Tool and start a 

NCO download. 

DCN-CCU DCN-

NCO 

Local floor muted after 

download of NCO or 

CCU 

Switch off and on the CCU or NCO 

DCN-NCO 

DCN-CCU,  

INT-TX04/08/16/32

 

Unexpected behavior 

when adding powered 

system units to the 

optical ring 

In case system units are added to the optical ring 

when the system is powered on, unexpected behavior 

can occur. Only connect units to the optical network 

when all units are powered off. 

DCN NCO 

DCN-CCU 

INT-TX04/08/16/32 

Audio disruption when 

switching on a 

transmitter 

Select the option “enabled” in menu 4b (network 

mode). 

DCN NCO 

DCN-CCU 

INT-TX04/08/16/32 

Audio disruption when 

one of the CCUs is in 

the mode  

“--“ 

Change the slave id “--" to a number. (refer to menu 

7I Multi Mode). 

INT-TX04/0816/32  The transmitter 

displays the message 

“No Network” 

Connect a powered DCN Next Generation or DCN 

wireless system to the transmitter or select the option 

“standalone” in menu 4b (network mode) 

 


background image

DCN Next Generation Release Notes

 

en | 14 

                                                   

 

Bosch Security Systems| 2014-10-31 

Product/function 

Problem 

Solution 

INT-RX04/08/32 

Charging indicator on 

the receiver is blinking 

Check whether the receiver is still working correctly. If 

this is the case: the battery pack is fully charged and 

can be recharged after using it a while.  

 

If this is not the case: follow the instructions as given 

in the troubleshooting table. 

DCN-CCU

 

DCN-CCU shows 

“Multi” while acting in 

“Single” 

When changing from “single” to “multi” mode, the 

DCN-CCU can remain working in “single” mode.  

 

If this is the case follow next procedure: 

1.

 

Select “multi” on all connected CCUs 

2.

 

Switch off all CCUs.  

3.

 

Reset to defaults the NCO. 

4.

 

Switch on all CCUs. 

DCN-CCU

 

Audio disruption 

during powering 

up/down a CCU in a 

Multi CCU system  

During powering up/down a CCU in a Multi CCU 

system the audio on the delegate units, connected to 

the remaining CCU’s, is shortly disrupted for 1 to 2 

seconds. 

DCN-CCU

 

Loss of settings after 

reboot of NCO in a 

Multi CCU system  

In case the Network Controller (NCO) in a Multi CCU 

system is rebooted, the settings and configurations 

changed during the past 30 seconds can be lost. 

When configuring interpreter desks wait minimum 30 

seconds before reboot the NCO. 

LBB 4402/00 

LBB 4404/00 

PRS-4DEX4 

Input routing does not 

work after download 

of optical devices 

Change all inputs to CH00 and then to the required 

channel. 

INT-TX 

Transmitter does not 

work after updating 

firmware 

Update FPGA to version 2.03 or higher 

Alternative solution: 

Update firmware of the INT-TX to version 2.80 

DCN-IDENC 

DCN-IDENC ID card 

encoder in not 

recognized in DCN-

SW. 

If other card readers/encoders are present or 

connected to the PC please disable them. 

Internal readers/encoders can be disabled in the 

BIOS or in the Windows Device Manager. 

CNConfig 

Error during 

installation “…verify 

that you have access 

to the directory.”  

Ensure that you have the required administrator 

rights. Restart installation.