PRESENTATION

The UPS is a Line interactive 
uninterruptible power system (UPS). 
When utility input is Normal, the UPS will      
charge the internal battery. If the utility 
input is abnormal, the UPS can supply AC 
power to the load immediately without 
resetting the computer.

The UPS:

1. Utilizes microprocessor based 

controls, to get assurance of 
reliability.

2. Automatic frequency selection to 

match with utility power.

3. Advanced battery management to 

prolong battery's life and fully charge 
the battery.

4. Overload & short circuit protection 

both in line and battery mode.

IND600 UPS is designed keeping in mind 
severe Indian Conditions. It has below 
unique features, which no ordinary UPS 
provides.

INDIA SPECIFIC FEATURES OF UPS

1. AVR Input Range 140V - 300V.
2. 3 output sockets.
3. OFF mode battery charging.

IND600 User Manual

Thank you for selecting ISO9001:2008 certified Uninterruptible power supply system (UPS). It provides perfect protection for your 
computers. The Manual Provides you with step by step guidance to install & use UPS. It contains important safety instructions for 
operation & correct installation of the UPS .In case you have any problem with the UPS please refer to this manual before calling 
customer service.

A.   Inspect UPS

Remove the UPS from its package and 
inspect it for damage that may have 
occurred during shipping. If any damage 
is found, re-pack the unit and return it to 
the place of purchase.

B.   Charging Battery

Charge battery for 16 hours for first time 
run.

C. Install UPS

• Do not place UPS in Direct sunlight.
• Do not place UPS near Excessive heat 

source

• Do not place UPS near Excessive 

humidity or let UPS come in contact 
with liquids.

Place the UPS atleast 20cms away from 
the monitor to avoid interference.

D.   Connect Computer to UPS

This UPS is equipped with 3 output 
sockets. Data sensitive equipment such 
as a computer, and monitor should be 
powered by battery backup sockets. 
Battery power is provided without 
restart in case of power failure.

Note : Do Not Plug a laser printer, copier, 
heaters, or other large electrical device 
into the UPS. The power demands of 
these devices will overload and possibly 
damage the UPS.

E.   Turn on / off UPS

F.   User Interface

Plug in the 3 pin power cord into 230V AC 
wall socket. Press the power switch to 
turn on   the UPS; press the power switch 
again to turn off the UPS. Do NOT press 
the switch too hard for extended life of 
the power switch.

Front Panel:

The front panel incorporates one LED 
and a switch. The 
functions of these
are listed below:

LED Status:

1. AC Mode : Green 

light steady.

2. Backup Mode : Green light blinking

Alarms:

1. Backup Mode : When in backup 

mode, the green LED blinks and the 
UPS Beeps every 2 seconds.

2. Battery low: Rapid beeping sound 

every half second.

3. Overload : Continuous beeping 

sound.

UPS

KEEPING YOUR TECHNOLOGY ALIVE

 


background image

230V

40-65Hz

140V-300V

Yes

3 Pin 10A, Indian Plug, 1.2 mt wire

230V +10%~-15%

Follows Input

230V ±10%

50 Hz ±1%

Modified Sinewave

0.6

>80%

3 output sockets

UPS output cutoff immediately

110% for 1 min

130% for 3 sec

4-8 ms

12V

7AH, SMF

Auto Discharge Protection

6 hrs (to 90% full capacity)

approx.  10-15 mins

LED steady

LED blink

Slow beeping sound (about 0.47 Hz)

Rapid beeping sound (about 1.8 Hz)

Continuos beeping sound

0-40°C, 0-95% humidity non condensing, 3500 meter max.

<40DbA (1 meter from surface)

15,000 meter max. elevation

4.2 Kgs.

101 x 279 x 142

IND600

1 PC Load (max 600VA)

Capacity
Voltage
Frequency
AVR
Generator Compatible
Connection
Voltage on mains
Frequency on mains
Voltage on Battery
Freq on Battery
Waveform
Power Factor Lagging
Efficiency
Sockets
O/p Short cct
O/p overload shutdown

Mains to Inverter
DC Bus
Internal Battery
Proctection
Typical Recharging Time
Backup time on PC 
with LCD monitor
Power ON
Inverter ON
Battery Backup
Battery Low
Overload
Ambient Operation
Audible Noise
Storage Condition
Weight (Kgs.)
Dimension - WxDxH (mm)

Features

!

Line interactive design

!

Boost and buck AVR (Auto voltage 
regulation)

!

Cold start function (DC power on)

!

Advanced battery management 
(ABM technology)

!

Battery charging in UPS OFF Mode

!

Microprocessor controlled

Specifications - 

IND600

Model

Input

Output

Protection 

Transfer Time
Battery

Indications

Alarm

Environment

Physical

ASIA POWERCOM PVT. LTD.

H.O.:

 401, 402 4th Floor,Arya Arcade CHS, Station Road, Vikhroli West , Mumbai - 400083.

sales@asiapowercom.com • support@asiapowercom.com • www.asiapowercom.com

Error/Problem

No LED
display
on the
front panel.

Alarm buzzer
beeps
continuously
when AC
supply is
 normal.

When Power
failure, backup
 time is
shortened.

Possible cause

Battery defect.

Power switch is
not pressed
.

Overload of
the UPS.

Overload of
the UPS.

Battery voltage 
is too low.

Battery defect
due to high
temp. operation
environment, or
improper
operation
of battery.

Remedy

Charge battery
up to 8 hours.
Replace with the
same type
of battery.

Press the power
switch again.

Verify that the
load matches the
UPS capability
specified in the
specs.

Remove some
noncritical load.

Charge battery
16 hrs. or more.

Replace with the
same type of
battery.

TROUBLESHOOTING

Use the table below to solve minor UPS 
installation or operation problems. If any 
abnormal situation occur that are not 
listed above, please call service people 
immediately.

Specification subject to change without prior intimation