User Manual

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference. and  
(2) This device must accept any interference received, including interference that may cause undesired operation. 
Caution 
Any changes or modifications (including the antenna) made to this device that are not expressly approved by the manufacturer 
may void the user’s authority to operate the equipment.  

 


background image

Contents

C. System Settings

D. Program Settings

.  Both Sides

. Settings

E. Application

.  Start Analysis

. Full  Analysis

.  View Mode

CRM
Moisture
Sebum
Pore
Melanin

Acne
Wrinkle

Sensitivity
Summary

1

2
3

5

7

8

9

10
11
12
13
14
15
16
17
18

F. Warranty

19

A. Components

B. H/W Parts

Notes on use

·

The images of this manual can be different with the actual things.

·

The information contained in this manual and future improvements are subject to 

     change without notice.

 


background image

Components

API 100

Charger

Manual

Battery

USB cable

Cradle

Sebum paper 1 box

Main body with skin lens

Cleaning cloth

1

A. Components

 


background image

H/W Parts

Both Sides 

Battery cover

LED light & lens

Mode up

Mode down

Capture

Start, Analysis, Result

External adaptor connection

Power on & off

2

B. H/W Parts - Both Sides

 


background image

H/W Parts

 

Settings

Insert the battery

  

Insert the battery and gently press the battery into place.

Close the cover.

1

2

To turn on the power

Press and hold “Power” button.

"Indicate LED" starts twinkling in blue light.

When it stops, the device is ready to use.

1

2

To turn off the power

Press and hold "Power" button.

"Indicate LED" will be turned off.

1

2

3

1

1

2

3

2

3

B. H/W Parts - Settings

 


background image

Charger can be used for 110V & 220V. 
The default is 220V. 

Then 220V European type is disassembled and 

you can see the 110V-220V American type inside 

of the charger.

Push the plug down to up at "Push" marked.

1

2

3

Choose the one you want to use and 

connect USB cable in adaptor.

H/W Parts

Settings

1

2

3

4

B. H/W Parts - Settings

 


background image

System Settings

Download & Install

PC User

Go to link on the browser as below.

http://www.aramhuvis.com/download

1

1

Install the program.

2

2

Tablet device or Smartphone user       

iOS : Go to "App Store" and search "Solutionist" to download the program.

Android : Go to "Google Play Store" and download it.

5

C. System Settings

 


background image

System Settings

How to connect with the program

First of all, check the Wi-Fi name and password which is described at back side of battery cover.

Wi-Fi name & password must be same and the format is "API_XXXX".

Turn on the device.

While turning on the device, prepare PC, Tablet, Smartphone to run the S/W.

Once “API” device is turned on, please go to network setting to set up the Wi-Fi connection.

!#$$$$%

When above code is connected, run the program “Solutionist". 

To check working properly, please check the program and see the left below side.

If it is correctly set up, you can see the orange light of Wi-Fi singal.

1

2

3

4

5

6

7

8

9

SSID: API_XXXX

PW:    API_XXXX

6

C. System Settings

 


background image

Program Settings

General Settings 

Change the language, analysis mode and etc.

1

Analysis Settings 

Set up the skin type and analysis parameter.

2

Recommended Products 

Available for each analysis result.

3

About

Check the current version and update is available in 

Wi-Fi connection.

4

7

D. Program Settings

 


background image

Touch “Analysis” to start.

1

Application

Start Analysis

8

E. Application - Start Analysis

 


background image

Application

CRM

Take picture of customer's face with built-in camera

or use the picture you already have in device.

4

Check the customer information and 

analysis result list.

3

Among the customer lists, select the client to check or 

start analysis.

Input the information. 

- full name, email address, gender and age group

1

2

9

E. Application - CRM

 


background image

Press "capture" button and when you hear "beep" sound, 

please put the sensor onto your skin and wait until 

you hear "beep" sound again.

1

Check the result.

To analyze next step, touch      button.

2

Application

Moisture

or

To analyze next st

or

Moisture sensor

10

E. Application - Moisture

 


background image

Application

Sebum

U-zone

T-zone

Check the result. 

To analyze next step, touch       button.

4

Put the sebum paper onto the U-zone on the cheek, 

then press it for 2~3 seconds.

1

Place camera on the pink area and take picture. 

(U-zone)

2

Sebum paper

Sebum paper

Put the sebum paper onto the T-zone on face, 

then press it for 2~3 seconds.

Place camera on the pink area and take picture.(T-zone)

3

or

To analyze next ste

or

11

E. Application - Sebum

 


background image

Application

Pore

Put the camera into the skin and touch       button 

to analyze.

2

Touch        button to activate camera mode.

1

Compare your image with 3 sample images.

- Good

- Normal

- Bad

4

The result will be appeared to compare with age group.

Check the result. To analyze next step, touch       button.

Touch "Compare" button to check the sample image.

3

or

Touch        button t

     

1

or

or

to analyze.

Th

lt ill b

3

or

or

Compare your ima

G

d

4

Check the result. To

Touch "Compare" b

or

12

E. Application - Pore

 


background image

The result will be appeared to compare with age group.

Check the result. To analyze next step, touch       button.

Touch "Compare" button to check the sample image.

Application

Melanin

Put the camera into the skin and touch       button 

to analyze.

2

3

Compare your image with 3 sample images.

- Good

- Normal

- Bad

4

Touch        button to activate camera mode.

1

or

Touch        button t

     

1

or

or

The result will be a

to analyze.

3

or

or

Touch "Compare" b

Compare your ima

Good

4

or

13

E. Application - Melanin

 


background image

The result will be appeared to compare with age group.

Check the result. To analyze next step, touch       button.

Touch "Compare" button to check the sample image.

3

Application

Acne

Put the camera into the skin and touch       button 

to analyze.

2

Compare your image with 3 sample images.

- Good

- Normal

- Bad

4

Touch        button to activate camera mode.

1

or

Touch        button to

     

1

or

or

The result will be ap

3

to analyze.

or

or

Touch "Compare" b

Compare your imag

Good

4

or

14

E. Application - Acne

 


background image

The result will be appeared to compare with age group.

Check the result. To analyze next step, touch       button.

Touch "Compare" button to check the sample image.

3

Application

Wrinkle

Put the camera into the skin and touch       button 

to analyze.

2

Compare your image with 3 sample images.

- Good

- Normal

- Bad

4

Touch        button to activate camera mode.

1

or

Touch        button t

     

1

or

or

The result will be ap

3

to analyze.

or

or

Touch "Compare" b

Compare your ima

Good

4

or

15

E. Application - Wrinkle

 


background image

Application

Sensitivity

4

Put the camera into the skin and touch       button 

to analyze.

2

The result will be appeared to compare with age group.

Check the result. To analyze next step, touch       button.

Touch "Compare" button to check the sample image.

3

Compare your image with 3 sample images.

- Good

- Normal

- Bad

4

Touch        button to activate camera mode.

1

or

Touch        button to

     

1

or

or

to analyze.

The result will be ap

3

or

or

Touch "Compare" b

Compare your imag

Good

4

or

16

E. Application - Sensitivity

 


background image

 Available to check product image.

3

Summary

Check the result.

1

Touch     button or each parameter on pentagon graph.

Once you select "Show Recommended Product", 

product image is appeared.

2

17

E. Application - Summary

 


background image

1

View Mode

In view mode, it is able to take pictures with capture 

button in many times.

2

The user can select analysis parameter to take picture. 

3

In one screen, you can see 4 different images maximum.   

4

The user can mark the defect or concern according to 

the image with note function.

18

E. Application - View Mode