GD Series

 

 

Gas Alarm Operation Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

AARU ENGINEERS 

 


background image

AARU

 

ENGINEERS                                             www.aaruengineers.com

 

 

Precautions:

 

 

To  avoid  personal  safety  injury,  Instrument  damage  and  potential  dangerous 

accident; do not use portable gas detector before reading this manual.

 

 

1. Description

 

 

GD gas alarm is a kind of wall-mounted household gas alarm designed to detect the 

concentration  of  combustible  and  toxic  gases  or  vapors  using  high  quality  air-sensitive 

component  and  manufactured  with  advanced  technology.  It  provides  visual  and  audible 

signals when the gas concentration reaches the presetting range, and reminds you to take 

prompt favorable action.

 

 

2 Specifications

 

 

Model

 

GD201 □GD221 □GD401 □GD501 □GD601

 

GD701  □GD801

 

 

 

Working Power

 

AC220V/110V±15%/DC24V/DC12V 

≤3W

 

 

 

Working Conditions

 

Temperature: 0℃~55℃ Humidity:<95%

 

 

 

Response time

 

≤30s(GD701≤2.5min ) resume automatically

 

 

 

 

 

Gas Sampling

 

 

Diffuse naturally

 

 

 

 

 

 

 

GD201:

 

combustible gas

 

10%LEL

 

 

 

 

 

 

GD221:

 

combustible gas

 

16%LEL

 

 

 

 

 

 

 

GD401:

 

for natural gas

 

 

10%LEL

 

 

 

 

Alarm level

 

GD501:

 

for methane and propane  10%LEL

 

 

 

 

 

 

 

GD601:

 

for propane

 

 

10%LEL

 

 

 

 

 

 

 

GD701:

 

for CO

 

 

150ppm

 

 

 

 

 

 

 

GD801:

 

for H2

 

 

1000ppm

 

 

 

 

 

Alarming Method

 

 

Visual and audible

 

 

 

 

 

 

 

Sound level

 

 

≥80dB

 

 

 

 

 

 

 

 

Weight

 

 

270g

 

 

 

 

 

 

 

Dimension

 

 

l×w×h,mm:126×78×37

 

 

 

 

 

Optional function

 

Gas shut off valve

 

relay output

 

 

 

 

 

 

 

Note: the power and the alarming level can be specified.

 

AARU

 

ENGINEERS                                             www.aaruengineers.com

 

 

Normal domestic gas:LPG: propane and butane;

 

 

Coal Gas:hydrogen and carbon monoxide; 

Natural Gas:methane;

 

 

All of the normal domestic gases is combustible gas, whose LEL (lowest explode limited) 

is below 10% of mixture with air.

 

When the concentration of the leaking gas in air, it will narcotize people’s centre nerve, 

even cause suffocation.

 

 

Gas

 

Basis

 

Exploding Range

 

Toxicity

 

 

 

 

 

LPG

 

C

4

H

10

、C

3

H

8

 

1.8%~9.5%

 

suffocation

 

Natural Gas

 

CH

4

 

5%~15%

 

suffocation

 

Coal Gas

 

H

2

、CO

 

4%~75%

 

toxicosis

 

 

8.2 

When the gas burning, it need abundant air, such as 1m

3

 need about 30m

3

 .So the 

placed with hearth such as kitchen has to be keep ventilate.  

8.3 

LEL Meaning:  

 

LEL is Lowest Explode Level. That is the lowest concentration of the gas in the air, 

which will cause exploding when meeting fire.

 

 

8.4 

Reasons of gas leakage:  

 

  Wrong ignition. 

  The fire is put out with winds during the cooking. 

  Fire is out during the cooking because of the change of the gas pressure. 

  The gas valve is not shut off well. 

  Wrong operation to the cooking tools. 

  The gas pipe is destroyed. 

  Other reasons. 

8.5 

Solutions of gas leakage:  

 

  Put out the fire. 

  Shut off the gas valve. 

  Open the windows and doors. 

  Check the leakage source. 

 

Don’t try to turn off any electric equipment when alarming continuously. Call the 

gas company with the outdoor phone. 

Please knock at the door instead of pressing the doorbell when find gas leakage 

in your neighbors’ home. 

 

Declaration

 

 

To keep continued product improvement, Hanwei reserves the right to change design 

features without prior notice

 

 

 
 

 sales@aaruengineers.co

m

 

1

 

                         

Tel: +91-9833707640  /  9870001727

 

 sales@aaruengineers.co

m

 

6

 

                    

Tel: +91-9833707640  /  9870001727

 


background image

AARU

 

ENGINEERS                                             www.aaruengineers.com

 

POWER: green POWER light shines show power on,,green POWER light flashes shows 

detecting the CO;

 

 

W-UP:It will keep light for 5 minutes when plug 

in. FAULT: Yellow light shows the sensor fault.

 

 

ALARM: When the CO concentration is above the preset level, it will flashes.

 

 

5.2.4 

Buttons:  

 

W-UP: press this button to stop the warm up and the detector get into detecting state 

immediately.

 

Test Button: The appliance will simulate alarming by pressing test button under 

detecting status.

 

 

6 Troubleshooting Guide

 

 

Problems…

 

 

Maybe caused by…

 

 

Solution

 

 

 

 

 

 

 

 

Green POWER light

   

Plug in not correct

 

 

Plug in again

 

 

is off

 

 

light broken

 

 

Contact the distributor

 

 

 

 

 

 

 

 

 

 

 

 

 

Press test button

 

 

Circuit fault

 

 

Contact the distributor

 

 

without alarm sound

 

 

 

 

 

 

 

 

 

 

 

The preheat is not finished

 

 

Wait until the preheat

 

 

Can’t detect the gas

 

 

finish

 

 

 

 

 

 

 

 

Circuit fault

 

 

Contact the distributor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Too

 

much

 

smoke,  alcohol

 

or

 

Move the clean air

 

 

 

perfume or

 

other volatility gas

 

in

 

 

 

and test again

 

 

The alarm give alarm

 

the air.

 

 

 

 

 

 

 

 

 

Stored too long

 

 

Warm up for more than

 

 

after the warm up

 

 

 

 

 

 

 

 

2 hours

 

 

 

 

 

 

 

 

 

 

 

Circuit fault

 

 

Contact the distributor

 

 

 

 

 

 

or factory maintain

 

 

 

 

 

 

 

 

 

7. Notices:

 

 

7.1 

It’s  possible  that  the  detectors  give  alarming  in  the  conditions  of  long  time  smoking, 

drinking, or using perfume, gasoline, paint and other volatile organic compound;  

 

7.2 Please do not use or store the detectors in the corrosive gases(such as Cl2);  

 

7.3  please  do  not  use  some  non  calibrated  gas  to  test  the  detectors,  If  the  gas 
concentration is too high, it will damage the detectors, also is harmful for human’s health;  

7.4 Clean the dust or dirt on the alarm frequently to keep air vent freely and the lights clear  

 

7.5 The detector needs to be keeping power on for more than 24 hours after a long time 

delivery of storage.  

 

8 Gas Safety Knowledge

 

 

8.1 

Sorts of gases  

AARU

 

ENGINEERS                                            www.aaruengineers.com

 

 

3 Functions and Indications

 

 

1

 

 

 

2

 

1     POWER Light (Green)

 

 

 

 

 

2      W-UP Light (Yellow)  

 

4

 

3      FAULT Light (Yellow) 

 

 

4      ALARM Light (Red) 

 

 

6

 

5

 

TEST Button: press to test alarm function

 

 

5

 

 

 

 

6

 

W-UP Button: press to stop the warm up.

 

 

 

 

 

 

7

 

7

 

Air vents

 

 

 

 

 

 

 

4. Installation

 

 

4.1 Fix the appliance on the wall at a horizontal distance as 2~4m from the cooker or gas 

source;  

 

4.2 The vertical location of the appliance should be decided according to the type of gas 

sort:  

LPG:Fix it within 0.3 meters above the ground; 

 

 

Natural Gas:Fix it within 0.3 meters below the Roof 

 

Such location should be avoided: 

 

Near the windows or passage with strong wind, 

 

Water fog and drop or such moist place; 

 

Easy polluted or high tem environment near Oven, 

 

Covered by other things. 

 

 

 

 

 

 

 

 

 

 
 

4.3 Choosing a proper installation way per conditions above.

 

 

Installation  1: Choose  a suitable  wall  or  place per the  above 4.1,  4.2 requests. Fix the 

hanging  plate  onto  the  wall  with  M5  or  M3  screw  through  the  screw  hole  (as  the 
following drawing, two optional types φ5 and φ3), then connect the appliance with the 

hanging plate.

 

 

Installation 2: Choose a suitable wall or place per the above 4.1, 4.2 requests. Fix a nail

 

 

 sales@aaruengineers.co

m

 

5

 

                   

Tel: +91-9833707640  /  9870001727

 

 sales@aaruengineers.co

m

 

2

 

                 

Tel:    91-9833707640  /  9870001727

 

 


background image

AARU

 

ENGINEERS                                          www.aaruengineers.com

 

 

(sizeφ2) into the wall. Hang the appliance on the nail with the hanging hole as the 

drawing below:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.4 Connection drawing of gas detector with functions of gas shut off valve or relay output, 

see above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

5 Using Instructions:

 

 

5.1 GD201/ GD221/GD401/GD501/GD601/GD801

 

AARU

 

ENGINEERS                                          www.aaruengineers.com

 

 

5.1.1. Plug in, (If ventilate fan, electro valve or other equipment is need to be connected, 

please connect corresponding circuit firstly.), then the green POWER light and yellow W -

UP light  will be  on. The  appliance  assumes non-operating status for three  minutes  while 

the sensor  warms up. After  warm up, the  yellow W -UP light  will be  off  automatically  and 

the appliance enters detecting status.  

 
5.1.2. If the gas in the environment rises above the preset alarm level, the appliance will 

enter  alarm  status,  the  red  ALARM  light  will  shine  and  the  buzzer  will  give  sound 

alarming.  Meanwhile,  the  alarm  will  activate  the  relay  or  the  valve  output;  at  the  same 
time, please cut off gas supply promptly and open the window. Don’t try to switch on or off 

any  electric  appliance,  including  mobile  phone  and  such  communications  tools.  Ask 

professional  person  to  eliminate  the  gas  leaking  malfunction  quickly  (the  alarm  with 

function of gas shut off valve shall output one close pulse signal each 10 seconds)  

5.1.3.  Once  the  gas  concentration  around  drop  under  the  preset  alarming  level,  the 

detector  will  stop  alarming  automatically  and  the  ventilating  fan  will  also  stop 

automatically. The detector gets into detecting state again.  

 

5.1.4.  If  the  yellow  fault  alarm  light  is  on,  it  shows  there  is  something  wrong  with  the 
detector and the detector can’t detect gas. Then please contact the distributor.  

5.1.1  Button operation:  

 

W-UP: press this button to stop the warm up and the detector get into detecting state 

immediately.  

 

Test  button:  The  appliance  will  simulate  alarming  by  pressing  test  button  under 

detecting status.  

 
5.2 GD701  

 
5.2.1. Plug in, (If ventilate fan, electro valve or other equipment is need to be connected, 

please connect corresponding circuit firstly.), then the green POWER light and yellow W -

UP light  will be  on. The  appliance  assumes non-operating status for three  minutes  while 

the sensor  warms up. After  warm up, the  yellow W -UP light  will be  off  automatically  and 

the appliance enters detecting status.  

 
After the  power light shines for 60s, it  will flash for 90s. The  detector  will  detect the CO 

gas in the end of the 90s.  

 

5.1.3.  If  the  gas  in  the  environment  rises  above  the  preset  alarm  level,  the  red  ALARM 

light will flash, the buzzer give sound alarming, drive the relay or valve shut off gas supply, 

Meanwhile, the alarm will activate the relay or the valve output; At the  same time, please 

cut  off  gas  supply  promptly,  and  open  the  window,  ask  professional  person  to  eliminate 

the gas leaking malfunction quickly.

 

 

The detector will make detection each 150s.

 

 

Once the gas concentration around drop under the preset alarming level, the detector will 

stop  alarming  automatically  and  the  ventilating  fan  will  also  stop  automatically.  The 

detector gets into detecting state again.

 

 