User Manual of 

Precision AC- DC Power Supply: Dual Channel 0-30V , 

5A max or 0-60V single channel 

 

 

 

 

 

 

 

 

AA Portable Power Corp (http://www.batteryspace.com) 

  Address: 860 S, 19

th

 St, Unit A, Richmond, CA, 94804 

Tel: 510-525-2328 

Fax: 510-439-2808 

Email: Sales@batteryspace.com 

Prepared & Approved by Max (20/10/10) 

 

 

 

 

 


background image

1. INTRODUCTION 

         

    Adjustable DC power supply are designed to be used in applications such as powering 

operational amplifier, push pull stages, logic    circuit and definition systems where plus and 

minus voltages are required to track with an insignificant error, and in any application 

where three independent power supplies housed in a single package represent an operating 

convenience. 

         

        The instruments consist of two identical, independently adjustable and one fixed 5V/3A 

DC power supplies. A front panel switch selects one of three modes of operation: 

independent, series and parallel. In the independent mode, the output voltage and current of 

each supply are controlled separately, and each supply is isolated up to 300V from output to 

chassis or output to output .In the tracking mode, both outputs are automatically connected 

in series or parallel, and the controls of the left supply adjust the magnitudes of both the 

positive and negative output voltages. Because the outputs are connected in a tracking 

configuration, any internal disturbance in the master supply (such as drift or ripple) will 

cause an equal percentage change in the outputs of both the supplies. 

         

          Each  power  supply  is  a  completely transistorized, well-regulated, constant 

voltage/constant current supply that will furnish full rated output voltage at the maximum 

output current or can be continuously adjusted throughout the output range. The front 

panel current controls can be used to establish the output current limit (overload or shout 

circuit) when the supply is used as a constant voltage source (independent or tracking modes) 

and the voltage controls can be used to establish the voltage limit (ceiling) when the supply is 

used as a constant current source(independent mode only).The supply will automatically 

cross over from constant voltage to constant current operation(current limited operation in 

the tracking mode) and vice versa if  the output current or voltage exceeds these preset 

limits. Each supply had its own front panel meter that can measure output voltage and 

current. One power supply may be used as a master supply controlling, one slave supplies 

furnishing various voltages or current for a system. When operated with the front panel 

mode switch in the tracking position, the instrument is automatically internally connected in 

auto-tracking configuration.    

 

Another feature of this instrument is its output ON/OFF key. 

a. For model A/B, it is only the key to cut off or resume the output as other similar 

instrument. 

 

(3) Parallel Tracking Operation 

    In the parallel tracking mode of operation, both supplies are strapped together (in 

parallel). This allows for a rating voltage supply with a double rating current capability. 

Only the MASTER output terminals are used for parallel tracking operation. In the parallel 

tracking mode, the SLAVE supply output voltage and current are tracking the MASTER 

supply output voltage and current. 

   A. Set the power supplies to the TRACKING PARALLEL mode by engaging both 

 


background image

TRACKING switches. 

      B. Because both voltage and current of the SLAVE supply track the MASTER supply, 

the maximum current and voltage are set using the MASTER controls. Using the MASTER 

supply output jacks, follow the instructions for "Setting Current Limit" (4-2 Section). 

Remember that the actual current output at the MATER supply output jack is double the 

reading on the SLAVE indicator meter. Then push the output on/off key to enter voltage and 

current setting. 

    C. Adjust the output voltage to the desired level using the MASTER VOLTAGE controls. 

    D. Turn off the power supply and the equipment to be powered during hook-up. 

    E. Connect the positive polarity of the device being powered to the red (+) terminal of the 

MASTER power supply. 

    F. Connect the negative polarity of the device being powered to the black (-) terminal of 

the MASTER power supply.   

      The configuration as shown in Fig.4-5. 

 

_

POWER

SUPPLY

M AST ER

S LAVE

+

+

_

Fig .4-5 Paral lel Tracki ng Op eratio n.

L OAD

L OAD

 

 

 

_

POWER

SUPPLY

MAST ER

SL AV E

+

+

_

L OAD

Fig .4-3 Sin gle Supp ly

 

 

 


background image

If the chassis or common of the equipment being powered is separate from both positive and 

negative polarity power inputs.   

The output of the SLAVE (negative) supply is tracking  the output of  the  MASTER 

(positive)  supply.  The configuration is shown in 

 

POWER
SUPPLY

MAST ER

SL AVE

L OAD

GND

Fig .4-4  Po s itiv e  and  Neg ati v e  Sup pl y.

 

 

b. For model C/D, it is not only the key to cut off or resume the output, but also be endowed 

with a new function which its    Kindred has not. This function is that when the output has 

been cut off, the both intending voltage and current can be preset, though in model A/B 

condition, only the intending voltage can be adjusted. It means that CC preset is very easy as 

CV preset.     

          Also in this way, an over current by any unknown load can be avoided. So the new 

function of the key is a safety design.     

          Especially this feature is very important to the student use 

2. SPECIFICATIONS 

2-1 General 

              Power Source: AC 110V/220V ( ±10%) 50/60Hz 

       Operation Temperature & Humidity 0 C to 40 C, <80% 

 

              Storage Temperature & Humidity -10 C to 70 C, <70% 

              Accessories 

                Power cord    ┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈

                Operation Manual┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈

 

 

 

 


background image

Rating 

 

Model 

Specifications 

A B C D 

 

Output voltage 

2H 0~30V 

2H 0~30V 

2H 0~30V 

2H 0~30V 

Output current 

2H 0~3A 

2H 0~5A 

2H 0~3A 

2H 0~5A 

Output fixed 

5V,3A 

5V,3A 

5V,3A 

5V,3A 

Output on/off 

V/A initializes 

X X  

 

 

Dimensions: 245(W)H140(H)H345(D)mm 

Weight: Approx.8kg 

2-2 Operation Mode 

(1). Independent: Two independent outputs and 5V fixed output. 

Output from 0 to rating volts and 0 to rating amperes. 

  (2). Series:          Output from 0 to ± rating volts at rating amperes each. 

Output from 0 to double rating volts at rating amperes. 

(3). Parallel:      Output from 0 to double rating amperes at rating volts. 

2-3 Constant Voltage Operation 

(1). Output current range                      0~rating voltage continuously adjustable. 

(2). Regulation                                        Line regulation0.01%+3mV. 

Load  regulation0.01%+3mV (rating current3A) 

Load  regulation0.02%+5mV (rating current>3A) 

(3). Recovery time                              100us (50% Load change, Minimum load 0.5A) 

(4). Ripple & Noise                            1mV rms, 5Hz~1MHz. 

(5). Temperature coefficient      300PPM/ C 

2-4 Constant Current Operation 

(1). Output current range           0~rating current continuously adjustable. 

(2). Regulation                                                        Line regulation0.2%+3mA. 

Load regulation0.2%+3mA. 

(3). Ripple current                                            3mA rms. 

2-5 Tracking Operation 

(1). Parallel operation 

Regulation                            Line    regulation0.01%+3mV. 

Load  regulation0.01%+3mV (rating current3A) 

0.02%+5mV (rating current>3A) 

(2). Series operation 

Regulation                                                    Line    regulation0.01%+5mV. 

Load  regulation300mV 

A. Positive and Negative supply (Fig.4-4). 

 

 

(2)  Series Tracking Operation 

 


background image

              When the series tracking mode of operation is selected, the positive (red) terminal of 

the SLAVE supply output is internally connected to the negative (black) terminal of the 

MASTER supply. 

       In the series tracking mode, the maximum output voltage of both MASTER and 

SLAVE supplies can be simultaneously varied with one control. The maximum SLAVE 

supply voltage is automatically set to the same value as the MASTER supply by using the 

MASTER VOLTAGE controls. 

    A. Set the power supplies to the TRACKING SERIES mode by engaging the left 

TRACKING switch and release the right   

                  TRACKING switch. In this case, the output voltage (across the two supplies) is 

actually double the displayed value.   

         For example, if the MASTER display is set for voltage metering and the SLAVE 

display for current metering, the output voltage across the MASTER positive (red) terminal 

and the SLAVE negative (black) terminal would be double the reading on the MASTER 

LED Display (since both supplies are putting out the same voltage). The actual output 

current would be the value read from the SLAVE LED Display (since the two supplies are 

wired in series, current flowing through each supply must be equal). 

    B . Set the SLAVE CURRENT control the fully clockwise position. The maximum 

current is set using the MASTER CURRENT control. Follow the instructions for "Setting 

Current Limit" (INDEPENDENT USE OF "MASTER" OR "SLAVE" SUPPLY section of 

this manual, using the MASTER CURRENT control. 

NOTE: 

                Because the supplies are being used in series, either CURRENT control can be used 

to set maximum current. If desired, the MASTER CURRENT control can be rotated fully 

clockwise and the SLAVE CURRENT control can be used to adjust the maximum current 

value. Because current through the two supplies must be equal when they are being used in 

series, the lower   

    CURRENT control setting will set the maximum output current. 

        C. Adjust the output voltage the desired level using the MASTER VOLTAGE controls. 

        D. Turn off the power supply and the equipment to be powered during hook-up. 

        E. If "single supply" operation is desired, this allows the power supply to be used as 

twice the voltage and rating current simply by using the negative (black) terminal of    the 

SLAVE supply and the positive (red) terminal of    the MASTER supply, the configuration as 

shown in Fig.4-3. 

               

 

4-4 Operation Mode 

   (1) Independent Operation 

                  The "MASTER" and "SLAVE" supplies each provide a 0 to rating volts output at 

up to rating amps. This procedure covers the use of the MASTER and SLAVE supplies only 

when they are used independently from one another. When used in the INDEPENDENT 

operating mode, the operating controls of the two power supplies are completely 

independent and either supply can be used individually or both can be used simultaneously. 

     A. Disengage both TRACKING mode switches (both switches out) so that the power 

 


background image

supply is in the INDEPENDENT operating mode. 

     B. Adjust "Voltage" control and "Current" control to the desired output voltage and 

current. 

          C. Turn off the power supply and the equipment to be powered during hook-up. 

          D. Connect the positive polarity of the device being powered to the red (+) terminal of 

the power supply. 

     E. Connect the negative polarity of the device being powered to the black (-) terminal 

of the power supply. 

     F. Fig.4-2 illustrates the connection procedure. 

POWER

SUPPLY

LOAD

M AST ER

SLAVE

+

LOAD

_

+

_

Fig .4-2 Ind ep endent Op eratio n.

 

 

Slave tracking error0.5%+10mV of the master 

           (No load, with load add Load regulation300mV). 

            B. Single supply (Fig.4-3) 

 

2-6  Meter 

        A. Display: 3 Digits panel meter H3 (0.4 Red LED display H2,0.4  Green LED 

display H2) 

                  B. Accuracy:±(0.5% of rdg    +2 digits) 

                        (NOTE: Model C/Model D Out OFF Accuracy ±(0.5% of rdg +8 digits)). 

                C. Voltmeter: 99.9V of full scale. 

                D. Ammeter: 9.99A of full scale. 

 

2-7 5V Output Specifications 

              1. Regulation                          Line regulation10mV,Load regulation15mV  

              2. Ripple & Noise                    2mV rms,5Hz~1MHz. 

       3. Voltage accuracy         5V±0.25V 

              4.    Output current                3A 

 

2-8 Insulation 

      Between chassis and output terminal 20MW or above (DC 500V) 

 


background image

      Between chassis and AC cord               300MW or above (DC 500V) 

 

 

3. PANEL CONTROLS AND INDICATORS 

         

         

 

V

1

C.V .

LABORATORY DC POWER SUPPLY

CURR ENT

POW ER

22

13

ON

29

8

7

28

OUTPUT

O N/ OF F

+

GND

-

OF F

12

21

19

20

C .V.

C.C.

PAR.

SLAVE

VO LTAGE

+

-

GND

17

18

15 14

16

INDE P.

SERI ES

PA RALL EL

TRACK ING

C.C.

MASTE R

3

4

A

V

2

A

11

+

-

5V F IXED 3A

23

24

5V/ 3A

LOAD

OVE R

VOLTAGE

6

5

10

9

Fig .3-1 F ron t Panel

 

 


background image

Fig.4-1 Con st an t Volt ag e/Co ns tant Character is tic.

Out pu t  Cu rren t

Co ns tant

Ran ge

Vo ltag e

Co ns tant Current
          Ran ge

 Ou tp ut
Vo ltag e

Cro sso ver
    Po in t

VO M AX
  IO MAX

 

(3). Output voltage overshoot 

        Maybe voltage between output terminals exceeds the present value when the power is 

turned on or off. 

4-2 Setting Current Limit 

        (1). Determine the maximum safe current for the device to be powered. 

    (2). In general, the (+) and (-) terminals of the power supply should be temporarily short 

together with a test lead. But in this instrument (Only model C/D), just pushing the output on/off   

key can make the short-circuit function.       

        (3). Rotate the VOLTAGE control away from zero sufficiently for the CC indicator to light. 

        (4). Adjust the CURRENT control for the desired current limit. Read the current value on the A 

meter. 

    (5). The current limit (overload protection) has now been preset. Do not change the CURRENT 

control setting after this step. 

        (6). Remove the short between (+) and (-) terminals and hook up for constant voltage operation. 

4-3 Constant Voltage/Constant Current Characteristic 

       The working characteristic of this series Power Supplies is called a constant voltage/constant 

current automatic crossover type. This permits continuous transition from constant current to 

constant voltage modes in response to the load change. The intersection of constant voltage and 

constant current modes is called the crossover point. Fig.4-1 shows the relationship between this 

crossover point and the load. 

              For example, if the load is such that the power supply is operating in the constant voltage 

 


background image

mode, a regulated output voltage is provided. The output voltage remains constant as the load 

increases up until the point where the preset current limit is reached. At that point, the output 

current becomes constant and the output voltage drops in proportion to further increases in load. 

The point is indicated by the front panel LED indicators. The crossover point is reached when 

the CV indicator goes off and the CC indicator comes on. 

              Similarly, crossover from the constant current to the constant voltage mode automatically 

occurs from a decrease in load. A good example of this would be seen when charging a 12-volt 

battery. Initially, the open circuit voltage of the power supply may be preset for 13.8 volts. A low 

battery will place a heavy load on the supply and it will operate in the constant current mode, 

which may be adjusted for a 1 amp charging rate. As the battery becomes charged, and its 

voltage approaches 13.8 volts, its load decreases to the point where it no longer demands the full 

1 amp charging rate. This is the crossover point where the power supply goes into the constant 

voltage mode. 

 

3-1 Front Panel 

22    Power switch: ON/OFF the power input. 
  V LED display: Indicates the MASTER output voltage. 

        V LED display: Indicates the SLAVE output voltage. 

        A LED display: Indicates the MASTER output current. 

        A LED display: Indicates the SLAVE output current. 

        Voltage control: for adjustment of the output voltage of the MASTER supply. Also functions 

as adjustment control for the maximum output voltage of the SLAVE supply when either 

parallel or series tracking operation.   

       Voltage control: for adjustment of the output voltage of the SLAVE supply when the 

independent operation. 

        Current control: for adjustment of the output current of the MASTER supply. Also functions 

as adjustment control for the maximum output voltage of the SLAVE supply when either 

parallel or series tracking operation.   

        Current control: for adjustment of the output current of the SLAVE supply.       

        C.V indicator: lights when the MASTER supply is in the constant voltage operation, in either 

the Series or Parallel Tracking mode, both the MASTER AND SLAVE supplies are in the 

constant voltage operation. 

      12 C. V indicator: lights when the SLAVE supply is in the constant voltage operation. 

      11 C. C. indicator: lights when the MASTER supply is in the constant current operation. 

      13 C. C. indicator: lights when the SLAVE supply is in the constant current operation. 

                                                            Also lights when the TRACKING PARALLEL mode is selected. 

        Over load indicator: lights when load on 5 volt supply becomes too large. 

      14    15    TRACKING Mode Switches: 

      Two push-button switches that select INDEPENDENT mode, series tracking mode, or parallel 

tracking mode as follows: 

      a. When both switches are disengaged (out), the unit is in the INDEPENDENT mode and the 

MASTER and SLAVE power supplies are completely independent from one another. 

            b. When the left switch is engaged (in) and the right switch is disengaged (out), the unit is in 

the TRACKING SERIES mode.   

 


background image

                    In  this  mode,  maximum  voltage  of both supplies is set using the MASTER VOLTAGE 

controls (voltage at output terminals of the SLAVE supply tracks the voltage at the output 

terminals of the MASTER supply). Also, in this mode of operation the positive terminal (red) of 

the SLAVE supply is connected to the negative terminal (black) of the MASTER supply. 

 

 

This allows the two supplies to be used as one 0 to double rating voltage supply. 

c. When both switches are engaged (in), the unit is in the TRACKING PARALLEL mode. In this 

mode the MASTER and SLAVE supplies are wired together in parallel and both the maximum 

current and voltage are set using the MASTER controls. 

The    MASTER and SLAVE outputs can be used as two individual (but tracking) power supplies or 

just the MASTER output can be used as a 0 to rating voltage supply with a 0 to double rating 

current capability. 

16    "    +    ": output terminal: positive polarity output terminal for the MASTER supply. 

19    "    +    ": output terminal: positive polarity output terminal for the SLAVE    supply. 

17    "    GND    " terminal: Earth and chassis ground. 

20    "    GND    " terminal: Earth and chassis ground. 

18  "  -  ": output terminal: Negative polarity output terminal for the MASTER supply. 

21  "  -  ": output terminal: Negative polarity output terminal for the SLAVE supply. 

23    "    +    ": output terminal: positive polarity output terminal for 5V supply. 

24  "  -  ": output terminal: Negative polarity output terminal for 5V supply. 

29 Output ON/OFF switch: DC power supply output when switch is engaged (in).And when output is 

off, both the voltage and current can be adjusted before the output is resumed. 

28 Output indicator: lights when switch is engaged (in). 

3-2 Rear Panel 

25  Fuse holder 

26  Power cord 

27  Fan 

30    AC voltage select switch 

4. OPERATION INSTRUCTIONS 

4-1 Precaution 

(1). AC input 

AC input should be within the range of line voltage±10% 50/60Hz. 

(2). Installation 

Avoid using the supply in a place where the ambient temperature exceeds 40 C. The heat sink 

located at the rear of the supply must have sufficient air space for radiation. 

 


background image

Fig .3-2 Rear Panel