Safety Warnings

!

Tools Required

Avenger™ Model 38M 

Installation & Operation Instructions

Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death.

 

}

For models containing Liquid Block™: Slowly open the supply pressure so that the minimum differential pressure required to                       

shut-off the Liquid Block™ is not met or exceeded..

 

}

Valve off the sample flow before installation.

 

}

Do not exceed any equipment pressure 

 

}

Four #10 screws for mounting bracket to panel.

 

}

Screwdriver for mounting bracket to panel.

 


background image

©

2005 A+ Corporation, LLC.  All rights reserved.

SCC-38M-InsInstallationOperation_100318

An ISO 9001:2008 certified company 

2

Technical Specifications

Dimensions

Back View

Side View

PORT D

3.700” 

0.355” 

1.250”

DIA.

3.256” 

0.883” 

3.700” 

1.876” 

2.626” 

2.000” 

2.625” 

4.270” 

4.995” 

MINIMUM MAINTENANCE CLEARANCE 8.100”

OPTIONAL 

MOUNTING 

BRACKET 

Technical Specifications

Maximum recommended
membrane flow rate

(For higher flow rates contact the factory)

Outside Diameter: ~ 1.4”
Inside Diameter: ~ 1.0”
Length: ~ 2.5”

Lowest possible pressure consistent with application

Machined parts: 316/316L stainless steel / NACE compliant
All other metal parts: stainless steel / NACE compliant
Sealing material: Fluoroelastomer standard
Membrane: inert

2,000 psig

1/4” female NPT

185˚F (85˚C) for Type 6 membrane
302˚F (150˚C) for Type 7 membrane 

1,000 cc/min for Type 6 membrane
3,600 cc/min for Type 7 membrane

*Maximum flow results in approximately 2 psi membrane differential pressure

Maximum recommended
supply pressure

Port sizes

5

Number of ports

50 cc

Internal volume

Wetted materials

Maximum pressure rating

Element size

Maximum temperature

35 psig*

*Slowly open the supply pressure so that the minimum differential
pressure required to shut off the Liquid Block™ is not met or exceeded.

Maximum Liquid Block™
valve auto-reset pressure

 


background image

©

2005 A+ Corporation, LLC.  All rights reserved.

SCC-38M-InsInstallationOperation_100318

An ISO 9001:2008 certified company 

3

Installation Instructions

Install the mounting bracket onto the Avenger Model 33M or 38M as per the Mounting Bracket Installation Instructions included in A+ 

Corporation Mounting Bracket Kit P/N 33-509SS for Model 33M or P/N 38-509SS for Model 38M. Aftermarket brackets may be mounted 

as per the mounting diagrams below.  Mount the Avenger horizontally as shown in the diagram. Lock washers may be used on the lower 10-

32 screws to tilt the filter as shown to ensure that liquids drain properly. “Port D” should be facing down as shown.  An optional downstream 

pressure gauge may be installed in “Port E” or it may be plugged.  The Model 33M has 1/2” NPT ports (except for the 1/4” NPT gauge “Port 

E”) and the Model 38M has 1/4” NPT ports. Refer to the “Application” for tubing connection instructions.

Application Drawing

 


background image

©

2005 A+ Corporation, LLC.  All rights reserved.

SCC-38M-InsInstallationOperation_100318

An ISO 9001:2008 certified company 

4

Application Drawing

 


background image

An ISO 9001:2008 certified company 

Genie,    

®

 Avenger,

TM

 Liquid Block

TM

 and Genie

®

 Membrane Technology

TM 

are trademarks or registered 

trademarks of A

+

 Corporation, LLC.  All other referenced trademarks are the property of their respective owners. 

Model Numbering & Additional Part Numbers

Model Numbering & Additional Part Numbers

How to build the model number:

How to build the replacement filter element number:

How to build the replacement membrane kit number:

How to build the replacement o-ring kit number:

Your model number is determined by your specific needs. Choose options below.
Sealing material 

0 =  Fluoroelastomer 

1 = Perfluoroelastomer

 

(other materials available upon request)

Element type  

07CFS = 0.1 micron coalescer fluorocarbon

  

SS10 = 10 micron stainless steel 

 

Membrane type

 

6 = Rejects ALL types of liquids from vapor                  7=  Rejects ONLY high surface tension liquids

 

 

Liquid Block™

 

Blank = No Liquid Block 

L = Liquid Block

Mounting bracket accessory Part # 38-509SS (sold separately)

38M

3/2

 S 

Sealing material

Element type

Membrane type
Liquid Block option

Liquid Block option

Liquid Block option

30

5

 5 

Element type

Membrane type

38M

5

0

38M

 5

 

Sealing material

S

L

S

Replacement filter and membrane kits contain 5 each. O-ring replacement kit contains all assembly o-rings.

We cannot recommend specific sealing materials due to the complex nature of sample stream compositions. Temperature and pressure also may be factors.  Unless specified otherwise, the product 
will ship with our standard sealing materials and materials of construction stated in the technical specifications section of the corresponding Product Sheet.
Please refer to dupontelastomers.com for sealing material recommendations and advice. It is the user’s responsibility to specify the sealing materials of construction for their application.