INSTRUCTION MANUAL

A750

720W  

GENERATOR

 


background image

2

Warranty 

2

Introduction 

3

Environmental protection 

3

Scope of product 

3

Description of symbols 

3

Specifications 

3

General safety instructions for power tools 

4

Risk of electrocution and fire 

5

Risk of fire 

6

Risk of injury and property damage  

when transporting generator 

7

Risk of breathing – inhalation hazard 

7

Risk of unsafe operation 

7

Risk of hot surfaces 

8

Risk of moving parts 

8

Risk from lifting 

8

Additional safety rules for generators 

9

Unpacking 

9

Know your product 

10

What can I use this generator for? 

11

Fitting the handle 

11

Mixing the fuel 

11

Filling the fuel tank 

11

Starting the engine 

12

Stopping the engine 

12

Connecting apparatus to the generator - AC 

12

AC overload cut out 

13

Periodic maintenance 

13

Generator maintenance 

13

Storage 

13

Spark plugs 

14

Air filter 

14

Tap extension fuel filter     

14

Petrol tank filter 

15

Cleaning 

15

Repairs 

15

Troubleshooting  

16

CONTENTS

Warranty Power Tools

For full details please visit us at www.909.com 

 


background image

3

Scope of product

This product is suited for lighting and camping.
It is not recommended to be used with any  

electronic devices. 

Description of symbols

The rating plate on your tool may show symbols.  

These represent important information about the  

product or instructions on its use.

Wear hearing protection.  

Wear eye protection.  

Wear breathing protection.

Conforms to relevant standards  

for electromagnetic compatibility.

Specifications

AC Output: 

240Vac ~ 50Hz

Rated Power: 

650W

Peak Power: 

720W

Phase: 

Single

Power Factor: 

coso- =1

Displacement: 

63cc

Engine: 

2HP, 2 stroke

No Load Speed: 

3000 RPM

Fuel Tank Capacity: 

4.2L

Fuel Type:  

2 Stroke (petrol / oil mixture)

Oil Type:  

2 Stroke

Fuel Mixture:  

Unleaded petrol / 

   

2-stroke oil (50:1) 

Note.

   

Ethanol Unleaded fuel  

 

is NOT recommended

Spark Plug:   

F5TC 

Equivalent Spark Plugs:  Bosch W5CC 

   

NGK BP5ES 

   

CHAMPION N12YC

Operation Noise Level:  

68dB/7m

Net Weight:  

17kg

Introduction

Your new 909 power tool will more than satisfy 

your expectations. It has been manufactured under 

stringent 909 Quality Standards to meet superior 

performance criteria.
You will find your new tool easy and safe to operate, 

and, with proper care, it will give you many years 

of dependable service.

CAUTION. 

Carefully read through this entire Instruction 

Manual before using your new 909 Power Tool. Take 

special care to heed the Cautions and Warnings.
Your 909 power tool has many features that will make 

your job faster and easier. Safety, performance, and 

dependability have been given top priority in the 

development of this tool, making it easy to maintain 

and operate.

Environmental protection

Recycle unwanted materials instead 

of disposing of them as waste. All tools, 

hoses and packaging should be sorted, 

taken to the local recycling centre and 

disposed of in an environmentally safe way.

 


background image

4

General safety instructions for power tools

To use this tool properly, you must observe the safety 

regulations, the assembly instructions and the operating 

instructions to be found in this Manual. All persons who use 

and service the machine have to be acquainted with this 

Manual and must be informed about its potential hazards. 

Children and infirm people must not use this tool. Children 

should be supervised at all times if they are in the area in 

which the tool is being used. It is also imperative that you 

observe the accident prevention regulations in force in your 

area. The same applies for general rules of occupational 

health and safety.

WARNING.

 When using power tools, basic safety precautions 

should always be taken to reduce the risk of fire, electric 

shock and personal injury. Also, please read and heed the 

advice given in the additional important safety instructions.

1. Keep the work area clean and tidy. 

Cluttered work areas 

and benches invite accidents and injury.

2. Consider the environment in which you are working. 

Do 

not use power tools in damp or wet locations. Keep the work 

area well lit. Do not expose power tools to rain. Do not use 

power tools in the presence of flammable liquids or gases.

3. Keep visitors away from the work area. 

All visitors and 

onlookers, especially children and infirm persons, should be 

kept well away from where you are working. Do not let others 

in the vicinity make contact with the tool or extension cord.

4. Store tools safely.

 When not in use, tools should be 

locked up out of reach.

5. Do not force the tool. 

The tool will do the job better and 

safer working at the rate for which it was designed.

6. Use the correct tool for the job. 

Do not force small tools 

or attachments to do the job best handled by a heavier  

duty tool. Never use a tool for a purpose for which it was 

not intended.

7. Dress correctly. 

Do not wear loose clothing or jewellery. 

They can be caught in moving parts. Rubber gloves and 

non-slip footwear are recommended when working outdoors. 

If you have long hair, wear a protective hair covering.

8. Use safety accessories. 

Safety glasses and earmuffs 

should always be worn. A face or dust mask is also 

required if the drilling operation creates dust.

9. Secure the work piece. 

Use clamps or a vice to hold the 

work piece. It is safer than using your hand and frees both 

hands to operate the tool.

10. Do not overreach. 

Keep your footing secure and 

balanced at all times.

11. Look after your tools. 

Keep tools sharp and clean for 

better and safer performance. Follow the instructions 

regarding lubrication and accessory changes. Inspect tool 

cords periodically and, if damaged, have them repaired 

by an authorised service facility. Inspect extension cords 

periodically and replace them if damaged. Keep tool 

handles dry, clean and free from oil and grease.

12. Remove adjusting keys and wrenches. 

Check to see 

that keys and adjusting wrenches are removed from the 

tool before switching on.

13. Stay alert. 

Watch what you are doing. Use common 

sense. Do not operate a tool when you are tired.

14. Check for damaged parts. 

Before using a tool, check 

that there are no damaged parts. If a part is slightly 

damaged, carefully determine if it will operate properly 

and perform its intended function. Check for alignment of 

moving parts, binding of moving parts, breakage of parts, 

proper mounting and any other conditions that may affect 

the operation of the tool. A part that is damaged should be 

properly repaired or replaced by an authorised service 

facility, unless otherwise indicated in this Instruction Manual.

15. Use only approved parts. 

When servicing, use only 

identical replacement parts. Use an authorised service 

facility to fit replacement parts.

WARNING. 

The use of an accessory or attachment, other 

than those recommended in this Instruction Manual, may 

present a risk of personal injury.

 


background image

5

Save these important safety instructions

Risk of electrocution and fire

Hazard

What could happen

How to prevent it

Improper storage of extension cord.

Extension cord can come into contact 

with hot engine parts resulting in 

damage. Using a damaged extension 

cord can result in electrocution or death.

Remove extension cord from the 

generator and store separately away 

from generator.

Operation of generator in rain, wet, 

icy, or flooded conditions.

Water is an excellent conductor of 

electricity! Water which comes in contact 

with electrically charged components can 

transmit electricity to the frame and other 

surfaces, resulting in electrical shock to 

anyone contacting them.

Operate generator in a clean, dry, well 

ventilated area. Make sure hands are dry 

before touching unit.

Placing generator on or against 

highly conductive surface, such as 

a steel walkway or metal roof.

Accidental leakage of electrical current 

could charge conductive surfaces in 

contact with the generator.

Place generator on low conductivity 

surface such as a concrete slab.
ALWAYS operate generator a minimum 

of 2 meters from any conductive surface.

Use of worn, damaged or 

ungrounded extension cords.

Contact with worn or damaged extension 

cords could result in electrocution.
Use of ungrounded cordsets could 

prevent operation of circuit breakers and 

result in electrical shock.

Inspect extension cords before use and 

replace with new cord if required.
Always use a cordset having a grounding 

wire with an appropriate grounding plug. 

DO NOT use an ungrounded plug.

Operation of unit when damaged, or 

with guards or panels removed.

Attempting to use the unit when it 

has been damaged, or when it is not 

functioning normally could result in fire or 

electrocution.
Removal of guarding could expose 

electrically charged components and 

result in electrocution.

Do not operate generator with 

mechanical or electrical problem. Have 

unit repaired by an Authorized Service 

Centre.
Do not operate generator with protective 

guarding removed.

 


background image

6

Risk of fire

Hazard

What could happen

How to prevent it

Attempting to fill the fuel tank while 

the engine is running.

Fuel and fuel vapours can become 

ignited by coming in contact with hot 

components such as the muffler, engine 

exhaust gases, or from an electrical 

spark.

Turn engine off and allow it to cool before 

adding fuel to the tank. Equip area of 

operation with a fire extinguisher certified 

to handle gasoline or fuel fires.

Sparks, fire, hot objects

Cigarettes, sparks, fires, or other hot 

objects can cause fuel or fuel vapours  

to ignite.

Add fuel to tank in well ventilated area. 

Make sure there are no sources of 

ignition near the generator.

Improper storage of fuel

Improperly stored fuel could lead to 

accidental ignition. Fuel improperly 

secured could get into the hands of 

children or other unqualified persons.

Store fuel in an approved container 

designed to hold fuel. Store container in 

secure location to prevent use by others.

Tampering with factory set engine 

speed settings.

Engine speed has been factory set to 

provide safe operation. Tampering with 

the engine speed adjustment could result 

in overheating of attachments and could 

cause a fire.

Never attempt to “speed-up” the engine 

to obtain more performance. Both the 

output voltage and frequency will be 

thrown out of standard by this practice, 

endangering attachments and the user.

Inadequate ventilation  

for generator

Materials placed against or near the 

generator or operating the generator in 

areas where the temperature exceeds 

40° C ambient (such as storage rooms 

or garages) can interfere with its proper 

ventilation features causing overheating 

and possible ignition of the materials or 

buildings.

Operate generator in a clean, dry,  

well ventilated area.

DO NOT OPERATE UNIT INDOORS  

OR IN ANY CONFINED AREA.
DO NOT OPERATE, OR TRANSPORT 

WITH FUEL IN THE TANK, IN A BOAT 

OR SIMILAR VESSEL.

Overfilling the fuel tank  

– fuel spillage.

Spilled fuel and its vapours can become 

ignited from hot surfaces or sparks.

Use care in filling the tank to avoid 

spilling fuel. Make sure fuel cap is 

secured tightly and check engine for 

fuel leaks before starting engine. Move 

generator away from refuelling area or 

any spillage before starting engine. Allow 

for fuel expansion. Never refuel with the 

engine running.

 


background image

7

Risk of injury and property damage when transporting generator

Hazard

What could happen

How to prevent it

Fire, Inhalation, Damage  

to Vehicle Surfaces

Fuel or oil can leak or spill and could 

result in fire or breathing hazard, serious 

injury or death can result. Fuel or oil 

leaks can damage carpet, paint or other 

surfaces in vehicles or trailers.

The generator is equipped with a fuel 

tap, turn the lever of this valve to the off 

position before transporting to avoid fuel 

leaks. Transport fuel only in an approved 

fuel container. Always place generator 

on a protective mat when transporting 

to protect against damage to vehicle 

from leaks. Remove generator from 

vehicle immediately upon arrival at your 

destination.

Risk of breathing - inhalation hazard

Hazard

What could happen

How to prevent it

Gasoline engines produce toxic 

carbon monoxide exhaust fumes.

Breathing exhaust fumes will cause 

serious injury or death.

Operate generator in clean, dry, well 

ventilated area. Never operate unit in  

enclosed areas such as garages, 

basements, storage, sheds, or in any 

location occupied by humans or animals. 

Keep children, pets and others away 

from area of operating unit.

Risk of unsafe operation

Hazard

What could happen

How to prevent it

Operation of generator in  

careless manner.

All sources of energy include the 

potential for injury. Unsafe operation  

or maintenance of your generator could 

lead to serious injury or death to you  

or others.

•   

Review and understand all of the 

operating instructions and warnings in 

this manual.

•   

Become familiar with the operation 

and controls of the generator. Know 

how to shut it off quickly.

•   

Equip area of operation with a fire 

extinguisher certified to handle 

gasoline or fuel fires.

•   

Keep children or others away from the 

generator at all times.

 


background image

8

Risk of unsafe operation continued

Operating generator while 

suspended

Generator will not operate properly and 

will cause damage to the generator and 

could cause serious injury or death to 

you or others.

Never operate generator while 

suspended or in an unlevel position. 

Always operate generate on a flat,  

level surface.

Risk of hot surfaces

Hazard

What could happen

How to prevent it

Contact with hot engine and 

generator components.

Contact with hot surfaces, such as 

engines exhaust components, could 

result in serious burns.

During operation, touch only the control 

surfaces of the generator. Keep children 

away from the generator at all times. 

They may not be able to recognize the 

hazards of this product.

Risk of moving parts

Hazard

What could happen

How to prevent it

Contact with moving parts can 

result in serious injury.

The generator contains parts which rotate 

at high speed during operation.  

These parts are covered by guarding to 

prevent injury.

Never operate generator with guarding 

or cover plates removed. Avoid wearing 

loose fitting clothing or jewellery which 

could be caught by moving parts.

Risk from lifting

Hazard

What could happen

How to prevent it

Lifting a very heavy object.

Serious injury can result from attempting 

to lift too heavy an object.

When lifting, always keep the object you 

are lifting near the vertical axis of your 

body.  DO NOT use you back to lift heavy 

loads. Both people should crouch down, 

grab the underside of unit and use your 

legs to carry the weight. Keep the object 

as near the centre of your body’s gravity 

as possible. Avoid twisting your bodies 

when carrying the unit; instead, turn your 

whole body using your feet.

 


background image

9

Additional safety rules for generators

1. Do not operate in a hazardous location. 

Such areas 

include where there is a risk of explosion of petrol fumes, 

leaking gas or explosive dust.

2. Do not operate in a confined area. 

Exhaust gases, 

smoke or fumes could reach dangerous concentrations.

3. The output of this generator is potentially lethal. 

The 

generator should not be connected to a fixed electrical 

installation except by an appropriately licensed person.

4. Protect your generator. 

This generator is NOT 

WEATHERPROOF and should not be exposed to direct 

sunlight, high ambient temperature and damp, wet or high 

humidity conditions.   

5. Do not smoke while refuelling. 

This is potentially 

dangerous as it may ignite the fuel and cause  

an explosion.

6. Take care not to spill fuel. 

When refuelling the generator 

ensure that the engine has been switched off. Prevent the 

spilling of fuel as this may also ignite with the hot engine. 

Never refuel whilst the engine running.

7. Be careful where you store the generator. 

Store the 

generator in a dry area away from inflammable liquids.

8. Keep your distance. 

The generator emits exhaust fumes. 

As a safety precaution do not stand close to the unit whilst it 

is in operation. Ensure bystanders also keep their distance.

9. Ensure you use oil-mix fuel. 

Ensure that you mix  

50 parts unleaded fuel to 1 part 2 stroke grade oil. If not 

mixed correctly at 50:1, the engine will overheat and 

cause damage to your generator. 

10.  Never fill fuel tank indoors. 

Never fill fuel tank when 

engine is running or hot. Do not smoke when filling  

fuel tank.

11.  Engine speed has been factory set to provide safe 

operation. 

Tampering with the engine speed adjustment 

could result in overheating of attachments and could 

cause a fire. Never attempt to “speed-up” the engine to 

obtain more performance. Both the output voltage and 

frequency will be thrown out of standard by this practice, 

endangering attachments and the user.

You MUST unplug any load from the generator before 

starting and stopping  to prevent permanent damage to 

any appliances.

Unpacking

Due to modern mass production techniques, it is unlikely that 

your 909 Power Tool is faulty or that a part is missing. If you 

find anything wrong, do not operate the tool until the parts 

have been replaced or the fault has been rectified. Failure to 

do so could result in serious personal injury.

 


background image

10

Know your product

1. Handle
2. Fuel cap
3. Fuel tank
4. Fuel tap
5. Recoil starter
6. On/off switch
7. Choke
8. Air filter cover
9. Tap extension fuel filter
10. AC Output 240V
11. AC circuit breaker 

4

5

3

2

1

6

7

8

10

4

9

11

 


background image

11

What can I use this generator for?

This generator is a small AC generator primarily designed 

for lighting. It is also suitable for small power tools or similar 

appliances.
This generator should never be used for electronic 

equipment like televisions, computers or similar type 

appliances. This also includes caravans which are fitted with 

inverter electronics.

Lights

600W

Pumps

300W

Refrigerators

Dryer

Washing machine (non electronic)

Hand tools

300W

Stationary tools

300W

Heaters

600W

Kettle

Fry pan

Toasters

Televison

Computer

Other sensitive electronics

Caravans

Fitting the handle

Proceed by placing the handle on top of the tank ensuring 

the 2 holes in the handles line up with the holes on the tank.
Screw the handle onto the petrol tank using the 2 screws 

provided with the unit. Ensure the flat washers and spring 

washers are fitted under the heads of the screws.

Mixing the fuel

1. The generator uses unleaded fuel and 2 stroke grade oil.

Note.

 Ethanol unleaded fuel is NOT recommended.

2. You need to mix both unleaded fuel and 2 stroke  

oil together.

3.   The proportion should be 50 parts unleaded fuel and  

1 part 2 stroke oil.

  Quick reference/common fuel mixture requirements for 

50:1 is:

  - 1 Litre of unleaded fuel mixed with 20mL of 2 stroke oil.
  - 5 Litres of unleaded fuel mixed with 100mL of 2 stroke oil.
4. The mixture should be poured into an approved fuel 

container. This fuel container should be clearly marked  

as a fuel container, sealed and made from fuel  

resistant material.

5. Once the mixture has been poured, shake the fuel 

container well to ensure that the contents have been 

thoroughly mixed. 

Filling the fuel tank

1. Switch off the engine.
2. Remove the fuel cap (2) by turning anticlockwise.
3. Pour the fuel/oil mix from the fuel container into the fuel 

tank (3). Because fuel expands, DO NOT FILL to the tip 

of the tank.

4. Replace fuel cap and turn clockwise to lock.

 


background image

12

Starting the engine

1. Before starting, ensure that no electrical apparatus has 

been connected to the generator. 

2. Turn the fuel tap (4) clockwise to the ‘on’ position.

3. Move the choke lever to the left hand side position.

4. Press “I” on the on/off rocker switch.
5.  Slowly pull the recoil starter until you feel it engage and 

then pull it briskly.  

Note: 

When the engine is started for the very first time, it 

will require a number of attempts to start until the fuel has 

travelled from the tank to the engine.

6. Once the engine has been operating for 10-15 seconds, 

slowly return the choke lever back to the right hand side 

position. This position will switch the choke ‘off’.

Note:

 If the generator stops, move the choke back to the full 

left hand side and repeat the starting operation..

Stopping the engine

1. Before stopping, ensure that 

no electrical apparatus is 

connected to the generator.

2. Press “O” on the engine switch 

(6) to ‘stop’ the engine.

3. Turn the fuel tap (4) anti-

clockwise to the ‘off’ position.

Connecting apparatus to the generator - AC

1. Start the engine. Allow the 

engine to run for a couple of 

minutes to warm up prior to 

connecting any apparatus to 

the generator. 

2. For 240V AC power, plug the 

power cord into the AC output 

socket (10).

 


background image

13

WARNING.

 Prior to connecting any product to the generator, 

check the rating label of the product. The generator is rated 

at 650W so if the product being connected is higher than 

650W, the protective cut out on the generator may operate 

to prevent over load damage to the generator. The generator 

will withstand short operation and spikes up to 720W.
It should also be very clearly understood that output voltage 

fluctuations will occur when various loads are connected 

and disconnected. It is best to always use a voltage or surge 

protector with this generator. 

It is NOT recommended to 

connect any electronic equipment to the generator such 

as computers, televisions, or stereo equipment. They 

are very sensitive to the input supply fluctuations and 

could be damaged if run off this generator. This warning 

also includes caravans where electronic equipment is 

incorporated as part of the wiring.

AC overload cut out

IMPORTANT: 

Exceeding the rated capacity of your 

generator can result in serious damage to your generator 

and connected apparatus.
1. The AC 240V output has a circuit breaker to protect the 

generator from over loading.

2. If the circuit breaker trips, unplug all electrical apparatus 

from the generator.

3. Let the overload cut out switch cool down.
4. If it is an AC apparatus causing the overload push the AC 

circuit breaker button (11).

5. When re connecting appliances, reduce the load to that 

which previously overloaded the generator.

Periodic maintenance

Items

Remarks

Every 50hrs 

or every 

month

Every 150 

hrs or every 

month

Spark Plug Remove 

Carbon

x

Air Filter

Cleaning

x

Fuel Filters Clean

x

Decarbon- 

isation

Clean

x

Generator maintenance

Your generator should be kept clean and dry at all times.  

The generator should not be stored or operated in environments 

that includes excessive moisture, dust or any corrosive vapours. 

If these substances are on the generator, clean with a cloth or 

soft bristle brush. Do not use a garden hose or anything with 

water pressure to clean the generator. Water may enter the 

cooling air slots and could possibly damage the rotor, stator and 

the internal windings of the generator head.

Storage

If you are going to store your generator for more than  

30 days, use the following information as a guide to  

prepare the generator for storage.

Never store generator with fuel in the tank indoors or 

in enclosed, poorly ventilated areas, where fumes can 

reach an open flame, spark or pilot light as on a furnace, 

water heater, clothes dryer or other gas appliances.

Remove all fuel from the fuel tank.
Drain all fuel from the Carburetor bowl.
When storing the generator, ensure the generator has  

fully cooled.

 


background image

14

Spark plugs

1. Remove spark plug from the 

generator with a spark plug 

spanner socket. 

2. Remove carbon deposits 

using a wire brush.

3. Check for discoloration  

on the top of the spark plug. 

The standard colour should 

be a tan colour.

4. Check the spark plug gap. The acceptable gap should be 

between 0.7 – 0.8mm.

Air filter

1. Remove the cover (8) on the front of the generator by 

removing the two screws.

2. Remove the air filter.
3. Wash the air filter in solvent.
4. Lubricate the filter using engine oil (SEA #20).
5. Thoroughly squeeze the filter removing excess oil.
6. Replace air filter back into the engine.
7. Secure the cover back onto the front panel of the generator.

IMPORTANT: 

Never run the engine without the air filter 

element in place.

Tap extension fuel filter

A small fuel filter has been fitted to the inlet side of the fuel 

tap (4), inside the tank. This tap extension fuel filter (9) 

prevents any dirt in the fuel from entering the fuel system.
The procedure for removing this filter in order to replace or 

clean it is given below.

Note: 

the following procedure should be performed in a well 

ventilated area, with no naked flames, sparks, or cigarettes. 

Safety glasses should also be worn and switch (6) set to the 

OFF position.
1.  Completely empty the tank of fuel. Ensure the fuel tap (4) 

is in the OFF position

2.  Compress the two wire arms of the hose clamp on the 

outlet hose at the tap (4) and slide the clamp back from 

the end of the hose by approx. 25mm. Slide the fuel hose 

off the outlet of the tap (4).

3.  Remove the 4 screws holding the fuel tank (3) to  

the generator assembly and lift the tank clear of  

the generator.

 


background image

15

4.  Loosen the lock nut locking 

the tap (4) on to the tank. 

Unscrew the tap from the tank 

and withdraw the tap from the 

tank. Be careful not to lose  

the small seal on the thread  

of the tap.

5.  Unscrew the tap extension 

fuel filter (9).

This filter can be cleaned in petrol to remove any build-up  

of dirt on the outside of the filter, or the filter can be 

replaced. Do not operate the generator without this filter in 

place. To replace the filter after cleaning, or with a new filter, 

simply screw the filter into the inlet side of the tap. 
6.  Ensuring the small seal is 

fitted to the tap thread, screw 

the tap back into the tank by a 

FULL 3–4 turns. Orientate the 

tap so the outlet of the tap is 

towards the rear of the tank, 

and the tap control is to the 

right hand side of the tank. 

Holding the tap firm, tighten 

the lock nut, ensuring the seal is 

clamped between the lock nut  

and the tank.
7.  Refit the fuel hose to the outlet 

of the tap and with the wire arms 

compressed, slide the hose 

clamp up onto the connection  

of the hose and the tap.

8.  Refill the tank with fuel and ensure there are no leaks 

between the tap and the tank, and with the fuel tap 

turned on, ensure there are no leaks where the fuel hose 

is fitted to the outlet of the tap. 

Petrol tank filter

1. Stop the engine.
2. Turn the fuel tap (4) to the  

‘off’ position.

3.  The petrol tank filter is located 

directly under the petrol 

cap. This protects impurities 

entering the fuel tank during 

refuelling. 

4. Remove the filter & wash thoroughly in a solvent.
5. Re-assemble.

Cleaning

1.  Keep your machine clean. The outside of the machine 

can be cleaned using a damp soft cloth with a mild 

detergent if required. Never use water to clean the 

generator as it may cause damage to internal parts.

2.  Some maintenance products and solvents may damage 

the plastic parts; these include products containing 

benzene, trichloroethylene, chloride and ammonia.

3.  Use a vacuum to clean air inlet and outlet louvres of  

the alternator.

4.  Take special care to keep the ventilation inlets/outlets  

free from obstruction; cleaning with a soft brush followed 

by a compressed air jet will usually be sufficient to ensure 

acceptable internal cleanliness.

5.  Wear eye protection when carrying out cleaning.

Repairs

Only an authorised service centre should repair the generator.

 


background image

16

Troubleshooting

Trouble

Possible cause

Suggested remedy

Engine will not start or will 

not keep running

1. Low on fuel/oil content

1. Add fuel/oil mix

2. Ignition switch in “Off” position

2. Turn to “ON” position

3. Faulty spark plug

3. Replace spark plug

4. Choke in wrong position

4. Adjust choke accordingly

5. Fuel tap in closed position

5. Open fuel tap

6. Unit loaded during start-up

6. Remove load from unit

7. Spark plug wire loose

7. Attach wire to spark plug

8. Dirty fuel filters 

8. Clean filters as per instructions

No electrical output

1. Faulty receptacle

1. Have service centre replace receptacle

2. Circuit breaker kicked out

2. Depress and reset

3. Defective capacitor

3. Have service centre replace capacitor

4. Faulty power cord

4. Replace cord

Repeated circuit breaker 

tripping

1. Overload

1. Reduce load.

2. Faulty cords or equipment.

 2.  Check for damaged, bare, or frayed wires 

on equipment. Replace.

Generator overheating

1. Generator overloaded.

1. Reduce load

2. Insufficient ventilation.

2. Move to adequate supply of fresh air.

 


background image