PDF User Manual

  1. Home
  2. Manuals
  3. 75F Dynamic Airflow Balancing Quick Start Manual

75F Dynamic Airflow Balancing Quick Start Manual

Made by: 75F
Type: Quick Start Guide
Category: Temperature Controller
Pages: 11
Size: 1.04 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

 

www.75fahrenheit.com       info@75fahrenheit.com     (651) 998-4080

 

75F

 Dynamic Airflow Balancing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

UICK 

S

TART 

G

UIDE

 

 


background image

 

       

 

 

Page 1 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

1.  Before You Begin 

Gather all of the information you will need to register the CCU (Central Control Unit). 

Description 

Your Information 

Wi-Fi SSID: 

 

Wi-Fi Password: 

 

Facility Manager email address: 

 

Installer email (must be approved and provisioned by 
75F before installing 

 

Building address (Street and Zip Code): 

 

 

 

 


background image

 

       

 

 

Page 2 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

Before You Begin 

Following is the list of components that shipped by 75F and a list of components that the installer is responsible for providing. 

Provided by 75F: 

Contractor is responsible for providing: 

 

Smart Dampers – pre terminated with 25’ harness 

o  ___ 6” Round 
o  ___ 8” Round 
o  ___ 10” Round 
o  ___ 12” Round 

 

___ CCU – Central Control Unit  

 

___ 6” USB micro to USB mini 

 

___ Plastic wings & 1 ½” #6 wood screws 

 

___ Pan Head screws for mounting CCU 

 

___ Antenna  

 

___ Allan Wrench  

 

___ WRM – Wireless Room Module 

 

___ Faceplate for WRM 

 

___ Sub base from WRM 

 

___ 5v DC regulated power supply  

 

___ Din rail and hardware for mounting power supply 

 

___ CO

Sensor 

 

___ Occupancy Sensor 

 

___ Occupancy Sensor Faceplate 
 
 

 

16/2 stranded speaker cable 

 

Wire connectors suitable for (3) 16 gauge wires 

 

Cable management materials such as zip ties, etc. 

 

Sheet metal screws 

 

Single gang junction boxes (recommended, not required) 

 

Electric enclosure for 5V DC Power supply 

 

Switch to turn off 120V AC power 
 
 

 

 


background image

 

       

 

 

Page 3 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

2.  Introduction 

 

In  the  75F™  system,  the  WRM  is  the 
equivalent  of  a  zone  controller.  It  senses 
room 

temperature 

and 

supply 

air 

temperature. Following instructions from the 
CCU,  the  WRM  controls  up  to  two  smart 
dampers in the supply air diffusers.  
 
The  WRM  ‘pairs’  with  the  CCU  via  a  secure 
wireless  mesh  network.  During  pairing,  the 
CCU  associates  the  WRM  with  a  particular 
zone that the user defines.  

 

Under  normal  circumstances,  the  WRMs 
modulate  the  air  flow  by  adjusting  the 
position of the smart dampers as per the CCU 
command.  However,  the  WRM  maintains  a 
local copy of the zone schedule and operates 
in  a  standalone  mode  in  communication  is 
lost.  It  will  change  the  desired  temperature 
per  schedule  and  control  the  damper 
according to its last update. 

 

 

 


background image

 

       

 

 

Page 4 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

Schematic Wiring Diagram 

 

 

 

 

 

 
 
 

CAT 5/6 Wire 

Harness 

RTU 

 


background image

 

       

 

 

Page 5 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

  

WRM 

16 Gauge Stranded 
5v DC Bus 

Optional 2

nd

 Damper 

Optional CO

2

 Sensor 

Optional Occupancy Sensor 

Central Control Unit (CCU) 

Wireless Mesh 

Network 

Smart Damper 

WiFi 

Internet 

Connection 

5v 
regulated 
DC power 

 


background image

 

       

 

 

Page 6 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

3.  Design Principles 

The 75F system was designed to have a WRM and a Smart Damper in every room being controlled by the CCU. These components all communicate with the 
CCU which acts as the local brains for the system creating a series of personal MicroZones which are smaller than traditional zone control systems. Each WRM 
establishes a MicroZone and controls up to two smart dampers.  

In spaces where there are more than two diffusers, the designer has a choice to either break the room up into multiple zones, or merge multiple sensors into 
one zone. To guide this decision, find out if the occupants have different temperature preferences in the space. If occupant desired temperatures are 1 or 2° 
F apart from one set of diffusers to the other, you might consider breaking this into two zones so that each occupant can have their own desired temperature 
(see Zones 1 & 2, below). This technique is limited to the thermal limits of the space, however. Place the WRMs on an interior wall location that best 
represents the desired temperature locations. If desired temperatures are the same from all diffusers, merge the zone as in Zone 9, below by pairing an 
additional WRM in the same room.  

 

Zone 9 (merged} 

WRM 

W

R

M

 

 

Zone 1 

W

R

M

 

 

Zone 2 

WRM 

W

R

M

 

W

R

M

 

W

R

M

 

W

R

M

 

WRM 

W

R

M

 

CCU

 

CCU 

WRM 

Central Control Unit 

Wireless Room Module 

Harness cable 

Supply duct 

Return duct 

 

RPS 

 

RPS 

Regulated Power Supply 

Bus Line 

 


background image

 

       

 

 

Page 7 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

Power Strategies 

Plan your 5v DC (USB) power strategy. Each WRM requires 5V, 60mA power. An efficient way to power many WRMs is to install power bus lines of less than 
100’ that run from the provided 110v AC to 5v 6A DC power supply to each WRM and a dedicated line for each CCU. Use at least 16/2 stranded cable (audio 
speaker cable) with red and black insulated wires no longer than 100’. Follow local code for wire type and connections. CCUs are powered with the provided 
5v DC regulated power supply at no longer than 20’.  

 

 


background image

 

       

 

 

Page 8 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

4.  Installation 

The following sequence of installation steps is recommended as a general outline and a good place to start as we understand each job will have 
a unique set of circumstances. Refer to the WRM and CCU Installation Guides for more detailed step.

 

Location 

See Section 3 Design Principles for power strategies.

 

1.  Locate where each WRM is mounted and measure 5’ up from the floor to cut a 1.5” hole to install 

the 

WRM. 

a.  The WRM can be installed in an existing junction box. DO NOT USE METAL BRACKETS AS 

THIS INTERFERES WITH WIRELESS RADIO SIGNALS. 

2.  Install the CCU at its designated location using the provided mounting bracket. 
3.  Install the power supply (in an electrical box is recommended) in a strategic location to supply power to all 75F components. Be sure the 

box is not on a lighting circuit. Don’t turn on the power supply until you complete wiring all components of the system.

Powering the System 

4.  Install single gang boxes within 15’ of each WRM. (Recommended, not 

required) 

5.  Lay the bus line from the power supply so they pass through all of the 

single gang boxes that are installed near each WRM.  

6.  Run a power line between the bus line (starting in each single gang box) 

to the WRM. Run a designated power line from the RPS to the CCU. It 
should not exceed 50 feet. 

 

 


background image

 

       

 

 

Page 2 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

Installing the Smart Dampers

 

7.  Install the smart dampers and run the harness to the location directly above 

the WRM it will be associated with. 

8.  Run the power supply and the damper harness down the wall and through the 

Hole in the wall. 

System Set Up 

9.  At each WRM location,  pull the power supply and damper harness through 

the sub base and  install it in the hole previously cut into the dry wall. Screw in 
the WRM to the sub base and snap on the faceplate.  

10. When everything is wired, turn on the power supply. 
11. Register the CCU and configure initial settings as described in the 75F CCU Installation Guide. Be sure to test 

each function of the RTU to be sure the harness wires are installed correctly. 

12. At this point, all WRMs should be reading “Up Dn” on the screen. 
13. Press the Up and Down button at the same time to begin the damper speed calibration sequence. The WRM 

will count down from 300 seconds and then read “AC” when completed.  

14. Press the Up and Down button again and the screen will show “AA” on one WRM at a time, then pair it with the CCU.  
15. Repeat until all WRMs are paired. 

Portal Set Up 

16. Customize the online Facility Manager Portal: 

a.  Upload a PNG or JPG of the floorplan to the online portal. Associate each WRM with its location on the floorplan 
b.  Customize the zone and system schedules  

17. Using the online Installer Portal, customize the portal with: 

a.  Customer contact information 
b.  Alarm recipients 
c.  Equipment details 

 

 

 


background image

 

       

 

 

Page 3 of 11

 

 

 

Planning Guide – Version 1.0  www.75F.io     

   info@75fahr75F.io    

  (651) 998-4080

 

5.  Resources 

Support portal: 

Visit the 75F Support portal below to find all product documentation and support related videos.  

 

http://www.75f.io/support

 

Password: 75FSupport 

Documents 

 

75F Installation Planning Guide 

 

OAO Installation and User Guide 

 

WRM User Guide 

 

CCU User Guide 

 

CCU Installation Guide 

 

WRM Installation Guide 

 

Work Order Sheet 

Videos 

 

Smart Damper Installation 

 

Wireless Room Module Installation 

 

Central Control Unit (CCU) Installation 

 

Install Wizard 

 

White Papers 

 

Doe Study – Energy Savings with Control Strategies 

 

California Bypass Dampers 

FAQs