PDF User Manual

  1. Home
  2. Manuals
  3. 4IPNET EAP705 Product Handbook

4IPNET EAP705 Product Handbook

Made by: 4IPNET
Type: Product Handbook
Category: Wireless Access Point
Pages: 17
Size: 1.13 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

 

 

EAP705  V1.00

Enterprise  Access  Point

Product Handbook

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.   

 

 

 

 

Copyright Notice 

 

 

 

This  document  is  protected  by  USA  copyright  laws  and  other  laws.  Besides,  the 

document  is  the  property  of  4IPNET,  INC.  You  may  not  copy,  reproduce,  distribute, 

publish,  display,  perform,  or  modify  any  part  of  this  publication  in  any  form  or  by  any 

means without prior written permission from 4IPNET, INC. You may not alter or remove any 

copyright or other notice from copies of the content. All other brand and product names 

are claimed or registered marks of their respective companies or organizations. 

 

All rights reserved. 

 

 

 

 

To download up-to-date version, please visit www.4ipnet.com. 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.   

ii 

FCC CAUTION 

 

This  equipment  has  been  tested  and  proven  to  comply  with  the  limits  for  a  class  B  digital  device, 

pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection 

against  harmful  interference  in  a  residential  installation.  This  equipment  generates  uses  and  can 

radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 

cause  harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that 

interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful 

interference to radio or television reception, which can be determined by turning the equipment off 

and  on,  the  user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the  following 

measures: 

---Reorient or relocate the receiving antenna. 

---Increase the separation between the equipment and receiver. 

---Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

---Consult the dealer or an experienced radio/TV technician for help. 

 

The  device  contains  a  low  power  transmitter  which  will  send  out  Radio  Frequency  (RF)  signal  when 

transmitting.  This  equipment  complies  with  FCC  RF  radiation  exposure  limits  set  forth  for  an  uncontrolled 

environment. This equipment should be installed and operated with a minimum distance of 20 centimeters 

between the radiator and your body. 

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:   

(1)    This device may not cause harmful interference, and   

(2)    This  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 

operation. 

 

Any changes or modifications not expressly approved by the party responsible for compliance could 

void the user's authority to operate this equipment. 

This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any  other  antenna  or 

transmitter. 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.   

iii 

CE CAUTION 

 

Declaration of Conformity with Regard to the 1999/5/EC (R&TTE Directive) for   

European Community, Switzerland, Norway, Iceland, and Liechtenstein   

Model: EAP705   

 

For 2.4 GHz radios, the device has been tested and passed the requirements of the following standards, and 

hence fulfills the EMC and safety requirements of R&TTE Directive within the CE marking requirement. 

• Radio: EN 300.328

:

 

• EMC: EN 301.489-1, EN 301.489-17,   

• EMC: EN 55022

 

Class B, EN 55024

:

+ A1 + A2

 

including the followings: 

      EN 61000-3-2, EN 61000-3-3. 

      EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,   

      EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 

• Safety: EN 60950-1 + A11, 

 

Caution:   

 

This  declaration  is  only  valid  for  configurations  (combinations  of  software,  firmware,  and  hardware) 

provided and supported by 4ipnet Inc. The use of software or firmware not provided and supported by 

4ipnet Inc. may result in the equipment no longer being compliant with the regulatory requirements.   

European  standards  dictate  maximum  radiated  transmit  power  of  100mW  EIRP  and  frequency  range 

2.400-2.4835 GHz. This equipment is intended to be used in all EU and EFTA countries. Outdoor use may be 

restricted  to  certain  frequencies  and/or  may  require  a  license  for  operation.  Contact  your  local  regulatory 

authority for compliance. 

 
Taiwan NCC Statement 
  

根據 NCC 低功率電波輻射性電機管理辦法  規定:

 

第十二條

 

經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或

變更原設計之特性及功能。

 

第十四條

 

 

 

低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時應立即停用,並改善至
無干擾時方得繼續使用。 
前項合法通信,指依電信法規定作業之無線電通信。 
低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之擾。

 

在5.25 ~ 5.35秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用。

 

  

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.   

 

Preface 

 

Package Contents 

The 4ipnet EAP705 Wall Jack Access Point is an 

on-the-wall as well as a ceiling-mounted dual radio 

Wi-Fi  IEEE  802.11b/g/n  +  a/n/ac  2  X  2  MIMO 

access point, designed to blend into a working or 

a living environment practically and elegantly with 

its simplistic yet sleek design.   

The  compact  EAP705  in  a  small  form  factor  lays 

snug  in  a  standard  wall  outlet  box.  Its  side  panel 

features LED status indicators and two RJ45 ports. 

It  has  the  interfaces  to  serve  both  wireless  and 

wired  LAN  access.  The  RJ45  pass-through  port 

allows  phone  or  IP-based  devices  to  pass  through 

EAP705 without the need for additional outlets.     

When  coupled  with  the  4ipnet  WHG  series 

Controller,  the  EAP705  supports  Tunnel-based  AP 

Management,  and  comes  with  all  standards 

demanded  by  enterprise  applications,  including 

business-grade security (802.1X, WPA and WPA2), 

and  multiple  ESSIDs  with  VLAN  tags  to  separate 

the  traffics  of  different  departments.  A  centralized 

WLAN  management  allows  enterprises  and 

organizations  to  support  a  wide  array  of  value 

added  applications,  such  as  load  balancing, 

bandwidth  control,  and  access  control.  The 

patent-pending 

4ipWES 

(Press-n-Connect) 

technology  bridges  multiple  EAP705s  at  the  touch 

of  a  button,  which  enables  a  quick  and  automatic 

WDS  Easy  Setup  by  pressing  the  WES  button  on 

EAP705. Extending wireless network coverage is a 

breeze,  be  it  across  conference  rooms  or  along 

hallways. 

EAP705’s high performance, security and optimal 

invisibility make it a perfect choice of wireless 

connectivity for your business.

 

 

 

1.  4ipnet EAP705 x 1 

2.  Quick Installation Guide (QIG) x 1 

3.  Power Adapter (DC 12V) x 1 (Optional) 

4.  Mounting Screws x 2 

5.  Mounting Panel x 1 

6.  Mounting Plate Lock Tool x 1 

 

 

 

 

 

It  is  recommended  to  keep  the  original 

packing  material  for  possible  future  shipment 
when  repair  or  maintenance  is  required.  Any 
returned  product  should  be  packed  in  its 
original  packaging  to  prevent  damage  during 
delivery. 

 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

System Overview 

 

Lower Panel 

1

1

2

3

 

EAP705 Lower Panel 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1  LAN 1 – 2 Ports 

Attach Ethernet cables here to connect to the wired local network. 

2  Bypass 

RJ45 Passthrough for phone or IP devices 

3  DC Jack 12V     

Attach the power adaptor here. 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

Lower Panel 

 

 

EAP705 back Panel 

 

 

 

 

1  110  Punchdown  Block 

(Passthrough) 

Copper wire punch down for in-wall application 

2  110  Punchdown  Block 

(Uplink)   

Copper  wire  punch  down  for  Uplink  connection.  This  can  be  used  to 

connect  to  a  controller,  gateway,  or  directly  to  the  internet.  PoE  is 

supported. 

3  Uplink (PoE) Port 

For  Uplink  connection.  This  port  can  be  used  to  connect  to  a  controller, 

gateway, or directly to the internet. PoE is supported. 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

Hardware Installation

 

 

Please follow the steps mentioned below to install the hardware of EAP705

Step 1.    Place the EAP705 at the best location. The best location is usually at the center of your intended 

wireless network. The EAP705 can be mounted on wall outlets or on any flat surface;   

 

Step 2.    Connect one end of the Ethernet cable to the Uplink port and the other end of the cable to a switch, 

a router, or a hub; or use the 110 punchdown block as your uplink connection. The 110 punchdown 

block may be connected with the following pin assignment: 

 

Orange 

Blue 

White Orange 

White Blue 

Brown 

Green 

White Brown 

White Green 

 

The EAP705 is now connected to your existing wired LAN network.   

 

Step 3.    There are three ways to supply power to EAP705 

a)  Connect the DC power adaptor to the power jack socket. 

b)  The Uplink port is capable of receiving PoE. Connect an IEEE 802.3af-compliant PSE device 

(e.g. a PoE-switch) to the Uplink port of EAP705 with the Ethernet cable. 

c)  Use a standard 110 punchdown tool to punch copper wires onto the punchdown block (pin 

assignment 568A) 

 

Step 4.    Fasten the Access Point to the mounting plate 

a)  Align the Access Point to the mounting plate using the arrow printed on the back of the Access 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

Point.   

b)  Align the Access Point to the 4 hooks and snap Access Point to the mounting plate   

c)  To lock/unlock Access Point from the mounting plate, use the Lock Tool provided. 

 

Now, the Hardware Installation is complete. 

 

• Punch down tools may vary by country. Please contact the 4ipnet Support Team for 

recommendations if needed. 

• Please use only the power adapter supplied with the package.    Using a different power adapter 

may damage this system. 

• To verify the wired connection between the AP and your switch / router / hub, please also check 

the LED status indicator of the respective network devices. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

Getting Started 

 

4ipnet EAP705 supports web-based configuration. When hardware installation is complete, EAP705 can be 

configured through a PC by using a web browser such as Mozilla Firefox 2.0 or Internet Explorer version 6.0 

and above. 

The default values of LAN IP address and subnet mask of EAP705 are: 

IP Address: 192.168.1.1 

Subnet Mask: 255.255.255.0   

 

Steps:

 

1.  To access the Web Management Interface, connect the administrator PC to the LAN port of EAP705 via 

an Ethernet cable. Then, set a static IP address on the same subnet mask as EAP705 in TCP/IP of your 

PC, such as the following example: 

IP Address: 192.168.1.100 

Subnet Mask: 255.255.255.0   

 

2.  Launch the web browser on your PC by entering the IP address of EAP705 (http://192.168.1.1) at the 

address field, and then press Enter

 

3.  The following Admin Login Page will appear. Enter “admin” for both the Username and Password fields, 

and then click Login

 

 

Administrator Login Page 

 

 

 

 

 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

4.  After a successful login to EAP705, a System Overview page of the Web Management Interface will 

appear, as depicted below. The Radio Status and AP Status will be shown.     

 

The Web Management Interface - System Overview Page 

 

5.  To  logout,  simply  click  on  the  Logout  button  at  the  upper-right  corner  of  the  interface  to  return  to  the 

Administrator Login Page. Click OK to logout.                                                             

 

 

 

 

 

 

 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

Common Settings 

 

Step 1. Change Administrator’s Password 

 

Change Password Page 

  Click on the Utilities icon on the main menu, and select the Change Password tab. 

  Enter the old password and then a new password with a length of up to 32 characters, and retype it in 

the Re-enter New Password field. 

  Click SAVE to save the changes. 

 

 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

Step 2. Configure General AP (Access Point) Settings 

 

Wireless General Settings Page 

  Click on the Wireless icon on the main menu, and then select the General tab. 

  Select the RF card you would like to set up.   

  Determine the Band and Channel settings: 

Select your preferred Band and Channel for you wireless connection. For example, select 

802.11g+802.11n for the band and 6 for the channel.   

 

 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

10 

Step 3. Configure VAP (Virtual Access Point) Profile Settings 

 

VAP Configuration Page (VAP-1 shown) 

  The EAP705 supports up to 8 virtual APs (VAPs) per radio.     

  Configure VAP profile settings

: 

(a)    Select the VAP Configuration tab to configure the settings of the desired VAP.   

(b)    Choose a specific RF card to set up   

(c)    Enable a selected VAP from the drop-down menu of Profile Name and configure related         

settings below. 

(d)    Check “CAPWAP Tunnel Interface” if you would like data of this VAP to go through the 

Controller when the Access Point is managed by CAPWAP.   

  Check VAP status

: 

After finishing VAP configuration, the status of the enabled Virtual APs shall be reflected on the VAP 

Overview page – at Wireless > VAP Overview.   

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

11 

 

Virtual AP Overview Page 

 

Step 4. Configure WDS (Wireless Distribution System) Settings (Optional) 

 

To  extend  the  wireless  coverage,  EAP705  supports  up  to  4  WDS  links  for  connecting  wirelessly  to  other 

WDS-capable APs, or peer APs. By default, all WDS profiles are disabled. 

 


background image

 

Product Handbook

Product Handbook

Product Handbook

Product Handbook    

EAP705 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.

                                                                                                                         

 

12 

  Click on the Wireless button on the main menu. 

  Select the Repeater tab. 

  Choose WDS as the Repeater Type

  Choose the desired RF card and WDS profile: 

(a)  Enable WDS.     

(b)  Enter the MAC Address (peer AP) and then Click SAVE.       

If you are using another EAP705 as the peer AP, simply repeat the above-mentioned steps to configure 

another peer AP(s). 

 

 Note: 

On each and every configuration page, you may click SAVE to save the changes of your configured 
settings, but you must reboot the system for the changes to take effect. After clicking SAVE, the 
following message will appear: “Some modifications have been saved and will take effect after 
Reboot.”
   

 

 

 

Congratulations! 

Now, 4ipnet EAP705 is installed and configured successfully.   

 

 

After  EAP705's  network  configuration  is  completed,  please  remember  to  change  the  IP  Address  of 
your PC Connection Properties back to its original settings in order to ensure that your PC functions 
properly in its real network environments. 

 

 

It is strongly recommended to back up your configuration settings. 

 

For further configuration and information, please refer to the User’s Manual. 

 

 

P/N: V10020150519