PDF User Manual

  1. Home
  2. Manuals
  3. 3xLogic VX-VTOF-01 Quick Start Manual

3xLogic VX-VTOF-01 Quick Start Manual

Made by: 3xLogic
Type: Quick Start Guide
Category: Security Camera
Pages: 10
Size: 1.03 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

VISIX Time of Flight People Tracking Camera  

VX-VTOF-01 Quick Start Guide 

v01-2016 

 
 
 

 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

2
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

Table of Contents 

1 PART NAMES AND POSITIONS ....................................................................................................................... 3

 

2 INSTALLATION ............................................................................................................................................... 4

 

3 IDENTIFYING THE CAMERA IP ADDRESS ......................................................................................................... 6

 

3.1

 

M

ANUALLY 

I

DENTIFY 

C

AMERA 

IP

 

A

DDRESS 

(MAC

 

A

DDRESS 

HEX

 

C

ONVERSION

) ......................................................... 6

 

3.2

 

A

UTOMATICALLY 

I

DENTIFY 

C

AMERA 

IP

 

A

DDRESS WITH 

3

X

LOGIC

 

C

AMERA 

S

ETUP 

U

TILITY

 ............................................ 7

 

4 VIEWING VIDEO ON THE WEBPAGE ............................................................................................................... 8

 

5 SETUP PAGE .................................................................................................................................................. 8

 

6 SAFE MODE ................................................................................................................................................... 8

 

7 HEXADECIMAL-DECIMAL CONVERSION TABLE ............................................................................................... 9

 

 

 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

3
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1 Part Names and Positions   

Please check names and positions of each part with the following image.  

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 
 
Lens:
 Lens is located inside the marked circle. It forms a 3D image 
by working with the IR illuminators on its sides. 
 
Status & Power LED: The light indicates whether it is powered on 
and operating normally. 
 
VCA Information Indicator 

 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

4
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

2 Installation 

There are several mounting methods using various types of accessories for this device. However, only one mounting 
method  (direct  mount  to  the  ceiling)  will  be  introduced  in  this  quick  start  guide,  and  refer  to  each  bracket’s 
installation guide for the other mounting types. 
 

CAUTION: 

The conditions of the installation environment shall be fully considered before user decides on the 

installation spot. You need to avoid a spot near glass windows and direct sunlight. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

Steps: 

Push the slides on both sides of the device to the other 
ends to detach the mount cover from the body.  

 
 
 
 
 
 
 
 
 
 
 

Separate the mount cover from the body like the image 
on the left. 

 
 
 
 
 
 
 
 
 

Drill  the  holes  on  the  ceiling  based  on  the  installation 
template, insert the plastic anchors into the four holes, 
and align the plastic anchors with the holes on the mount 
cover. Then, attach the mount cover by using the M4x30 
screws included in the package. Tighten the screws for 
the firm attachment. 

 

Mount Cover 

Slide 

Mount Cover 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

5
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Steps: 

Connect  the  LAN  cable  from  the  ceiling  to  the  LAN 
connector on the device for the PoE connection. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Connect the safety wire on the device to the safety wire 
bracket on the mount cover by referring to the image on 
the left. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Attach the device to the mount cover on the ceiling by 
aligning the slide guide with the slide. 

 
 
 
 

 

 

Safety Wire 

Safety Wire Bracket 

Slide 

Slide Guide 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

6
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3 Identifying the Camera IP Address 

To begin viewing video or configuring a camera’s network settings from the camera’s web/browser interface, the 
user  must  first  identify  the  device’s  IP  address.  The  default  IP  address  of  the  camera  is  192.168.XXX.XXX.  The 
default subnet mask is 255.255.0.0. 

On simple, private networks, a user can manually identify the IP address of the camera by converting the camera’s 
MAC  address  hex  values,  however,  the  alternative  method,  which  is  recommended  by  3xLOGIC,  is  to  use  the 
3xLOGIC  (VSX-IP)  Camera  Setup  Utility.  The  utility  makes  detection  and  configuration  of  VISIX  camera’s  in  any 
network environment simple and easy, regardless of network complexity. 

Please install the camera before continuing. Neither of the below methods require an external internet connection, 
however, the camera and the PC being used to communicate with it must reside on the same network. 

 

3.1 

  Manually Identify Camera IP Address (MAC Address HEX Conversion) 

Users can access the camera’s web interface and settings using a device’s default IP address: In case of generic 
private network environment where IP address 192.168.XXX.XXX are used, the following procedure can be used 
to identify a device’s IP address. 

Steps: 

1.  Convert the device’s MAC address to the IP address. Refer to Section 7: 

Hexadecimal-Decimal 

Conversion Chart

 at the end of the manual (the MAC address of the device is written on the label 

affixed to the side or bottom of the device). 

 

 

 

2.  Start the Microsoft® Internet Explorer web browser and enter the address of the device.  

3. 

Web streaming and device configurations are supported through ActiveX program. When the ActiveX 
installation window appears, authorize and install the ActiveX.

 

 

                MAC address = 00-13-23-01-14-B1 → IP address = 192.168.20.177 

Convert the last two sets of hexadecimal numbers to decimal 
numbers. 

Steps: 

Push the slides on both sides of the device to the other 
ends to lock the device onto the mount cover. 

 
 
 
 
 

 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

7
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

3.2 

  Automatically Identify Camera IP Address with 3xLOGIC Camera Setup 
Utility 

Using the 3xLOGIC Camera (VSX-IP) Setup Utility is recommended for any network environment as it will find all 
VISIX cameras across multiple subnet masks, utilizing mDNS search discovery. Camera information such as IP 
Address, Subnet Mask and Gateway Settings will be displayed and can be edited from this utility. To search for 
a device, launch the utility (

VSXIPUtility.exe

)

NOTE: 

VSXIP Utility v9.40.0226 or newer is required for detection of the VX-VTOF-1.  

Steps: 

1. 

Click on Detect Online Devices/ Change IP Address to proceed to the Online Devices window.  

 

Figure 2-1: 3xLOGIC Camera Setup Utility - Detecting Online Devices 

 

After clicking Detect Online Devices/ Change IP Address on the main page you will be taken to the Online 
Devices 
window. A list of all VISIX devices discovered on your network will be visible.  

2. 

To select a device, click on the desired device in the generated menu under the Select Online Devices 
area.  

3. 

To change an IP address for a selected VISIX camera in the Detect Online Devices window, select the 
desired camera, click on the Change IP Address button. The fields under the Configure IP Address 
area will un-grey to allow for manual editing of camera IP addresses as well as other settings.  

 

Figure 2-2: 3xLOGIC Camera Setup Utility - Identifying Device IP Address

 

 

4. 

When you have finished editing the settings, click Save IP Address to save new changes.  

 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

8
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

4 Viewing Video on the Webpage 

1.  Once the device’s IP address has been identified, type the IP into the Microsoft® Internet Explorer web 

browser URL bar and enter the address of the device.  
 

During initial access, the ActiveX controls installation window may pop up. 

 
 
 
 

Steps: 

1. 

When the browser asks to install the AxUMF software, click the Install button to proceed. 

2. 

When the Setup installation pop-up window appears, click the Install button to preceed with the rest 
of the installation. 

NOTE: 

The figures during the installation process may differ depending on the system OS and the IE version.

 

 

5 Setup Page

 

To setup the device configuration: 

 

Steps: 

1. 

Click the Setup button on the upper left corner of the web page. 

2. 

Enter the user name and the password when the login page is displayed. Then, click the OK button 
(The default username and password are admin and 12345).  

 

To learn how to set up the camera on the web page for the advanced configuration, refer to the device’s user 
manual. 

 

6 Safe Mode

 

Your device will get restarted in safe mode if the device does not completely boot certain times. The main causes 
for safe mode are as follows. 
 

 

The power supply is continually unplugged certain times in the middle of system booting. 

 

The firmware files required for system booting are damaged. 

 

There are conflicts in the system settings. 
 

You will see the page to indicate that your device is in safe mode and to guide you what to do in steps. Follow 
the instructions on the webpage according to each step. 
 

NOTE: 

One  of  the  methods  to  update  firmware  is  using  IP  Admin  Tool.  Please  refer  to  Section  3.2  Error! 

Reference source not found.

 

for the detailed procedure.

 

 

NOTE:

 If your device is still in safe mode after trying to update firmware, please contact your local agency to get 

further assistance

.

 

 


background image

VISIX Time of Flight Quick Start Guide | VX-VTOF-01  

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

9
 

10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

7 Hexadecimal-Decimal Conversion Table 

Refer to the following table when you convert the MAC address of your device to IP address. 

 

Hex  Dec    Hex  Dec    Hex  Dec    Hex  Dec    Hex  Dec    Hex  Dec    Hex  Dec 

 

25 

37 

 

4A 

74 

 

6F 

111   

94 

148   

B9 

185   

DE 

222 

 

26 

38 

 

4B 

75 

 

70 

112   

95 

149   

BA 

186   

DF 

223 

 

27 

39 

 

4C 

76 

 

71 

113   

96 

150   

BB 

187   

E0 

224 

 

28 

40 

 

4D 

77 

 

72 

114   

97 

151   

BC 

188   

E1 

225 

 

29 

41 

 

4E 

78 

 

73 

115   

98 

152   

BD 

189   

E2 

226 

 

2A 

42 

 

4F 

79 

 

74 

116   

99 

153   

BE 

190   

E3 

227 

 

2B 

43 

 

50 

80 

 

75 

117   

9A 

154   

BF 

191   

E4 

228 

 

2C 

44 

 

51 

81 

 

76 

118   

9B 

155   

C0 

192   

E5 

229 

 

2D 

45 

 

52 

82 

 

77 

119   

9C 

156   

C1 

193   

E6 

230 

 

2E 

46 

 

53 

83 

 

78 

120   

9D 

157   

C2 

194   

E7 

231 

0A 

10 

 

2F 

47 

 

54 

84 

 

79 

121   

9E 

158   

C3 

195   

E8 

232 

0B 

11 

 

30 

48 

 

55 

85 

 

7A 

122   

9F 

159   

C4 

196   

E9 

233 

0C 

12 

 

31 

49 

 

56 

86 

 

7B 

123   

A0 

160   

C5 

197   

EA 

234 

0D 

13 

 

32 

50 

 

57 

87 

 

7C 

124   

A1 

161   

C6 

198   

EB 

235 

0E 

14 

 

33 

51 

 

58 

88 

 

7D 

125   

A2 

162   

C7 

199   

EC 

236 

0F 

15 

 

34 

52 

 

59 

89 

 

7E 

126   

A3 

163   

C8 

200   

ED 

237 

10 

16 

 

35 

53 

 

5A 

90 

 

7F 

127   

A4 

164   

C9 

201   

EE 

238 

11 

17 

 

36 

54 

 

5B 

91 

 

80 

128   

A5 

165   

CA 

202   

EF 

239 

12 

18 

 

37 

55 

 

5C 

92 

 

81 

129   

A6 

166   

CB 

203   

F0 

240 

13 

19 

 

38 

56 

 

5D 

93 

 

82 

130   

A7 

167   

CC 

204   

F1 

241 

14 

20 

 

39 

57 

 

5E 

94 

 

83 

131   

A8 

168   

CD 

205   

F2 

242 

15 

21 

 

3A 

58 

 

5F 

95 

 

84 

132   

A9 

169   

CE 

206   

F3 

243 

16 

22 

 

3B 

59 

 

60 

96 

 

85 

133   

AA 

170   

CF 

207   

F4 

244 

17 

23 

 

3C 

60 

 

61 

97 

 

86 

134   

AB 

171   

D0 

208   

F5 

245 

18 

24 

 

3D 

61 

 

62 

98 

 

87 

135   

AC 

172   

D1 

209   

F6 

246 

19 

25 

 

3E 

62 

 

63 

99 

 

88 

136   

AD 

173   

D2 

210   

F7 

247 

1A 

26 

 

3F 

63 

 

64 

100   

89 

137   

AE 

174   

D3 

211   

F8 

248 

1B 

27 

 

40 

64 

 

65 

101   

8A 

138   

AF 

175   

D4 

212   

F9 

249 

1C 

28 

 

41 

65 

 

66 

102   

8B 

139   

B0 

176   

D5 

213   

FA 

250 

1D 

29 

 

42 

66 

 

67 

103   

8C 

140   

B1 

177   

D6 

214   

FB 

251 

1E 

30 

 

43 

67 

 

68 

104   

8D 

141   

B2 

178   

D7 

215   

FC 

252 

1F 

31 

 

44 

68 

 

69 

105   

8E 

142   

B3 

179   

D8 

216   

FD 

253 

20 

32 

 

45 

69 

 

6A 

106   

8F 

143   

B4 

180   

D9 

217   

FE 

254 

21 

33 

 

46 

70 

 

6B 

107   

90 

144   

B5 

181   

DA 

218   

FF 

255 

22 

34 

 

47 

71 

 

6C 

108   

91 

145   

B6 

182   

DB 

219   

 

 

23 

35 

 

48 

72 

 

6D 

109   

92 

146   

B7 

183   

DC 

220   

 

 

24 

36 

 

49 

73 

 

6E 

110   

93 

147   

B8 

184   

DD 

221   

 

 


background image

 

 

10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC

 

 

1
0
 

 

10385 Westmoor Drive, Suite 210 

Westminster, CO 80021 

303.430.1969 

Toll Free: 877.3xLOGIC 

www.3xlogic.com 

 

 
© 2016 3xLOGIC Inc. All rights reserved.  
Information in this document is subject to change without notice. 3xLOGIC and the 
3xLOGIC logo are trademarks of 3xLOGIC, Inc. all other trademarks are property of 
their respective owners.  
Revised: July 6

th

, 2016