PDF User Manual

  1. Home
  2. Manuals
  3. 3xLogic VISIX VX-VSS-20 Quick Start Manual

3xLogic VISIX VX-VSS-20 Quick Start Manual

Made by: 3xLogic
Type: Quick Start Guide
Category: Security Camera
Pages: 14
Size: 1.93 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

VISIX Stereoscopic People Counting Camera  

VX-VSS-20 Quick Start Guide 

v01-2018 

 
 
 

 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

Table of Contents 

1 INTRODUCTION ................................................................................................................................................... 3

 

2 INSTALLATION SPECIFICATIONS ........................................................................................................................... 4

 

2.1

 

P

ACKAGE 

C

ONTENTS

 ............................................................................................................................................. 4

 

2.2

 

F

OCAL 

L

ENGTH AND 

C

OUNTING 

W

IDTH

 .................................................................................................................... 4

 

3 INSTALLATION ..................................................................................................................................................... 5

 

3.1

 

I

NSTALLATION 

S

TEPS

 ............................................................................................................................................. 5

 

4 IDENTIFYING AND CONFIGURING CAMERA ......................................................................................................... 9

 

4.1

 

 

I

DENTIFYING THE 

C

AMERA ON 

L

OCAL 

N

ETWORK

 ........................................................................................................ 9

 

4.2

 

C

OUNTING 

C

ONFIGURATION

 ................................................................................................................................. 10

 

Configuration for Single Camera ........................................................................................................................ 10

 

Configuration for Multiple Cameras ................................................................................................................... 11

 

 

 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

1 Introduction 

The VISIX™ VX-VSS-20 Stereoscopic camera is a special purpose, low-cost people counting smart camera, combining 
state-of-the art 3D imaging technology with intelligent video analytics capability to provide remarkable people 
counting accuracy. The VX-VSS-20 camera includes high-performance advanced analytics as a standard feature, 
improving count accuracy when compared to the current generation of thermal and stereoscopic cameras. The 
device has a high-quality video analytic system and maintains excellent tracking performance even in the most 
challenging lighting conditions or when one object is partially obscured by another.  
 
The camera utilizes dual-lens binocular stereoscopic technology with 3D head detection and 3D tracking to obtain 
accurate real-time trajectories of all moving objects within its monitoring scope. The device than analyzes this 
trajectory data to achieve high-precision people counting. The VX-VSS-20 is suitable for high-traffic environments 
where people counting is required such as shopping malls, supermarkets, subway stations, bus terminals, secure 
entrances, etc… 
 
In conjunction with 3xLOGIC’s VIGIL video management suite of products, comprehensive data analysis and query 
processes can be easily established to help bolster loss-prevention capability and provide you with invaluable 
insights into your business via advanced reporting in VIGIL Client or VIGIL Trends.  
 

 

Figure 1-1  

Standard Deployment Topology Diagram 

 

 

Figure 1-2 Advanced Reporting Samples (VIGIL Client) 

 

 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

2 Installation Specifications 

2.1 

 Package Contents 

Dual-Lens Camera

 

Base

 

 

 

Mount base first, then snap on the camera 

Screw and Plastic Anchors 

Camera Drill Template 

 

 

 

2.2 

 Focal Length and Counting Width  

The counting width depends on the camera’s installation height. The recommended installation height for the VX-
VSS-20 is less than 4.0m (13.1ft). Specifics are outlined in the below table:    
 

Focal Length 

(mm/ft)

 

Installation 

Height 

(m/ft)

 

Max. Counting 

Width 

(m/ft)

 

Without 

Doorframe

 

With Doorframe

 

2/0.066  

2.5/8.2  

1.8/5.9  

Placed in the 

middle  

0.68m(2.2ft) to 

door  

Placed in the 

middle  

3.0/9.8  

2.9/9.5  

Placed in the 

middle  

1.1m(3.6ft) to door  

Placed in the 

middle  

3.5/11.5  

4.0/13.1  

Placed in the 

middle  

1.52m(5.0ft) to 

door  

Placed in the 

middle  

 

 

 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

3 Installation  

3.1 

  Installation Steps   

Be certain to mount the cameras as described. Failure to mount the camera as per the instructions may cause loss 
of accuracy. The recommended mounting process is outlined below:  
 

 

Figure 3-1 Side-view diagram of mounting position 

 

Figure 3-2 Top-down Diagram of Mounting Position  

 

 

Figure 3-3 Image after Proper Installation  

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

 

1.  Keep the 3xLOGIC logo facing the same direction as the Front arrow indicator on the back of the device. 

See below example for reference:  

 

Figure 3-4 Front Arrow and 3xLOGIC Logo  

 

2.  Make sure the camera is mounted vertically above the passenger flow (90°, vertical to the ground). 

Reference the below example: 

 

Figure 3-5 Passenger Flow (perpendicular to the door) 

 

3.  For some scenarios where there are multiple cameras, mount the cameras as per the two below 

guidelines: 

► 

If there are turnstiles, each camera should be mounted to monitor a specific  turnstile  

 

 

Figure 3-6 Sketch map of multiple cameras installation 

 

► 

If there is no turnstile, mount the cameras in one line, and make sure the cameras have the same 
focal length. Then, keep a proper distance between each camera according to the overlap (see the 
yellow area below) of the adjacent two cameras’ counting width. The suggested overlapping length is 
between 0.2-0.5m.  

 

Figure 3-7 Sketch map of multiple cameras installation 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

WARNING 

The flow of traffic should always be up-and-down (vertical) in relation to the camera’s mounting position.  

 

Figure 3-8 Passenger flow in horizontal direction - Incorrect  

 

 

Figure 3-9 Passenger flow in slant direction - Incorrect 

 

 

Figure 3-10 Passenger flow in up-and-down (vertical) direction – Correct 

 

1.  The passageway width should be within the camera’s counting width threshold. 

 

Figure 3-11 Appropriate Counting Width Threshold  

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

2.  Avoid obstacles such as glass door, shield doors and turnstile that block the camera. For each divided 

passageway, mount one camera directly above.  

 

 

Figure 3-12 Avoiding Obstacles Within Field-of-Vision 

3.  The camera should be mounted as close as possible to the passageway without obstacles obscuring its 

field-of-vision. Remove any obstacles or adjust the camera mounting position if necessary. 
Meanwhile, to prevent miscounts, if there is a sliding or automatic door onsite, make sure the 
trajectory of the door does not overlap with the detection line. The counting mechanism may be 
falsely triggered by the door opening and closing  

 

Figure 3-13 Too far away from the door/Obstacle below camera  

 

 

Figure 3-14 Recommended installation  

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

4  Identifying and Configuring Camera 

4.1 

 Identifying the Camera on Local Network 

Using the 3xLOGIC Camera (VISIX-IP) Setup Utility is recommended for any network environment as it will find all 
VISIX cameras across multiple subnet masks, utilizing mDNS search discovery. Camera information such as IP 
Address, Subnet Mask and Gateway Settings will be displayed and can be edited from this utility. To search for a 
device, launch the utility. Download the utility 

here

 or contact your 3xLOGIC representative for the latest version. 

 

Note: VSXIP Utility v10.10.0025

 

or newer is required for detection of the VX-VTOF-1. 

Steps:

 

1. 

Click on Detect Online Devices/ Change IP Address to proceed to the Online Devices window.  

 

Figure 4-1 : 3xLOGIC Camera Setup Utility - Detecting Online Devices 

 

After clicking Detect Online Devices/ Change IP Address on the main page you will be taken to the Online Devices 
window. A list of all VISIX devices discovered on your network will be visible.  

2. 

To select a device, click on the desired device in the generated menu under the Select Online Devices 
area.  

3. 

To change an IP address for a selected VISIX camera in the Detect Online Devices window, select the 
desired camera, click on the Change IP Address button. The fields under the Configure IP Address area 
will un-grey to allow for manual editing of camera IP addresses as well as other settings.  

 

Figure 4-2 3xLOGIC Camera Setup Utility - Identifying Device IP Address 

 

4. 

When you have finished editing the settings, click Save IP Address to save new changes.   

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

10 

4.2 

 Counting Configuration  

 

CONFIGURATION FOR SINGLE CAMERA  

To configure the camera’s people counting, login to the camera’s web interface (enter the camera IP address identi
fied in Section 3.2 into a web browser URL bar, enter credentials and click Login) and follow the below instruction t
o configuring people counting: 

 

1.  Enable People Counting: Navigate to Configuration>People Counting and toggle Enable People 

Counting

2.  Calibration: Select the green Calibration Area box, drag it to proper location and click Calibration

After this, the Height value on the configuration page will refresh (close to the real height). A red 
Counting Area box will deploy as well as a yellow Detection line. The arrows indicate the directional 
entrance/exit. See the example below for more detail:   

 

Figure 4-3 Calibration 

 

Note: If auto calibration fails, switch to [Manual] and input the measured “Height”, then 
click [Calibration].   

 

 

3.  Detection line: Move the detection line to the proper location (about 0.5m from the door). Adjust the 

length of detection line to the door’s width by dragging the line ends. See the below example for 
reference:   

 

Figure 4-4 Configuring Detection Line 

 

4.  Save and Test Configuration: After configuration, click Save and begin testing the camera’s count 

accuracy. If the camera’s count is inaccurate, slightly adjust the detection line’s location and length 
until the desired results are achieved.  

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

11 

 

 

CONFIGURATION FOR MULTIPLE CAMERAS  

1.  Repeat the configuration process for each camera following the steps outlined in the previous section.   

2.  Move each camera’s detection line and connect the ends of adjacent lines. Some objects could be placed 

on the image border for reference. See picture below:  

 

Figure 4-5 Configuration of each detection line  

 

 

4.3 

 Saving the Camera to VIGIL Server 

After configuring the camera’s people counting rule and testing its accuracy, the camera can be saved to VIGIL 
Server. To save the camera to VIGIL Server: 
 

1.  Return to the  3xLOGIC Camera (VISIX IP) Setup Utility interface (pictured in Section 4.1).  

 

2.  Click on Detect Online Devices/ Change IP Address to proceed to the Online Devices window.  

 

3.  Select the VX-VSS-20 configured in the previous section from the list of detected devices. Click Save to 

VIGIL. .  

 

  

Figure 4-6 Saving Camera Settings to VIGIL 

 

4.  You will be prompted to choose the camera channel, video codec and recording FPS values Select the 

desired settings and camera channel and click OK to save the camera to VIGIL Server.  

 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

12 

4.4 

 Interfacing People Counting Rule with VIGIL Server via Analytics Bridge 

After adding the camera to VIGIL Server, the final step required is to interface the camera’s people counting rule 
with VIGIL Server. This will allow the VIGIL Server to receive the people counting data from the camera and insert it 
into the VIGIL database. To begin: 
 

1.  Navigate to Start > All Programs>VIGIL and click VIGIL Analytics Bridge. If the Analytics Bridge is not 

installed, contact a 3xLOGIC support representative to receive the latest version. 

 
The Analytics Bridge main screen is pictured below. All configuration of the Analytics Bridge takes place from this 
screen.  
 

 

Figure 4-7 Figure 4-3: VIGIL Analytics Bridge Main UI 

 
To begin configuration of the VX-VSS-20 camera within VIGIL Analytics Bridge: 
 

1.  Click Add Device. 

 

 

Figure 4-8 Adding a Device to VIGIL Analytics Bridge 

 

The Add/Edit Camera window will appear, shown below. 
 

1.  Select the VIGIL Server camera channel associated with the VX-VSS-20  camera from the VIGIL Camera 

drop-down. 

 

2.  Set the Device Type to 3xLOGIC VISIX-IP.  

 

 

NOTE:

 The Device Type setting must correspond with the Type setting configured for this 

device in VIGIL Server’s Network Camera settings (see Fig 4-3). These values must be set to 
3xLOGIC-VISIX-IP in both VIGIL Analytics Bridge and VIGIL Server to allow for successful 
operation. This setting should be automatically configured in VIGIL Server when adding the 
camera with the VISIX IP Setup Utility but if you are experiencing issues, confirm the device 
type settings are set to 3xLOGIC VISIX-IP in both applications.  
 

 

Figure 4-9 VIGIL Server – Network Camera Settings 

 


background image

VISIX Stereoscopic People Counting Camera | Quick Start Guide | VX-VSS-20 

 

 

12000 Pecos Street, Suite 290, Westminster, CO 80234 | www.3xlogic.com | (877) 3XLOGIC

 

 

13 

 

3.  Fill in the remaining connection information (by default, this camera use Port 80).  

 

4.  Toggle Collect Counters and Display Counters in VIGIL on. 

 

 

Figure 4-10 VIGIL Analytics Bridge - Add Device Window 

 

5.  Once you have configured camera connection information, click the Load Device button to detect the 

analytics rules currently configured on the camera. Whenever new rules are configured on the camera, the 
Detect button must be clicked to refresh the rules in the list. The rule list will populate with available rules.  

 

6.  Toggle Enable for all rules you wish to interface with the VIGIL Server.  

 

 

Note:

 Toggling Alarm on will enable alarms in VIGIL Server for the selected rule. If Alarm is not toggled, 

only rule data will be inserted to the VIGIL DB. VCM Sync (enabled by default) will enable rule data 
syncing with VIGIL Central Management. If no VCM is available, this option is ignored.  

 

7.  Click OK after detecting. The Add/Edit Device window will close 

8.  On the main screen, click Save Changes. Save Changes will only appear when a camera has been added or 

edited. All new rule settings will be pushed to VIGIL Server. 

 

 

Figure 4-11 VIGIL Analytics Bridge - Saving Changes 

 
Configuration is now complete. The VIGIL Server system will now record video as well as data based on the VX-VSS-
20’s detected people counting events. 

 


background image

 

 

 

12000 Pecos Street, Suite 290 

Westminster, CO 80234 

303.430.1969 

Toll Free: 877.3xLOGIC 

www.3xlogic.com 

 

 
© 2018 3xLOGIC Inc. All rights reserved.  
Information in this document is subject to change without notice. 3xLOGIC and the 
3xLOGIC logo are trademarks of 3xLOGIC, Inc. all other trademarks are property of 
their respective owners.  
Revised: November 28

th

, 2018