PDF User Manual

  1. Home
  2. Manuals
  3. 3onedata IES605-2D series User Manual

3onedata IES605-2D series User Manual

Made by: 3onedata
Type: User Manual
Category: Network Router
Pages: 16
Size: 0.88 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

IES605-2D series

Industrial Ethernet switch

User manual

Shenzhen 3onedata Technology Co.,Ltd

Tel: +86-755-26702668 Fax: +86-755-26703485

www.3onedata.com


background image

Summarize

IIES605-2D series is an industrial, management, redundant

industrial Ethernet switch and integrate 2 port serial device servers.

It included

1. IES605-2D (RS-232)-P (12/48VDC),

Support 5 port 10/100Base T(X) and 2 port RS-232,

2. IES605-2DI (RS-485)-P (12/48VDC),

Support 5 port 10/100BaseT(X) and 2 port RS-485/422,

3. IES605-1F-2D (RS-232)-P (12/48VDC),

Support 4 port is 10/100BaseT(X) Ethernet, 1 port is 100BaseFX

fiber port and 2 port RS-232,

4. IES605-1F-2DI (RS-485)-P(12/48VDC),

Support 4 port is 10/100BaseT(X) Ethernet, 1 port is 100BaseFX

fiber port and 2 port RS-485/422,

5. IES605-2F-2D (RS-232)-P (12/48VDC),

Support 3 port is 10/100BaseT(X) Ethernet, 2 port is 100BaseFX

fiber port and 2 port RS-232,

6. IES605-2F-2DI (RS-485)-P (12/48VDC).

Support 3 port is 10/100BaseT(X) Ethernet, 2 port is 100BaseFX

fiber port and 2 port RS-485/422,

it adopted SW-Ring redundant technology (Recovery time<20ms),

users can set the redundant easily to increase network reliability,

furthermore. It adopted no fan, low power consumption design,

IP30, corrugate high strength iron shell, the performance is more

steadily. It accorded with CE, FCC standard and Industrial 4 class,

DIN rail installation and wide operating temperature (-40- 75C), it

can satisfied some kinds of industrial environment, it can provide

reliable and quickly solution for your Ethernet device

Packing list

Please check the packaging and accessories by your first

using.


background image

Industrial Ethernet switch(IES605-2D series)ⅹ 1

User manual ⅹ 1

CD ⅹ 1

Certificate of quality ⅹ 1

Warranty card ⅹ 1

Please inform us or our distributor if your equipments have

been damaged or lost any accessories, we will try our best to

satisfy you.

Features

IEEE802.3, IEEE802.3u, IEEE 802.3x

Support SW-Rin

gTM

redundant network patent technology

(Faulty recovery time<20ms)

Support 2 port RS-232/ RS-485/ RS-422 serial device server

Support based on socket application access
Support Sever, Client, UDP based mode and Sever, UDP

advanced mode

Support TCP, UDP, ARP, and DHCP protocol

Support Web management

Support 2K MAC address table

Support 2 power supply input and 1 relay alarm output

Support port line and redundant network faulty/unusual,

local and remote alarm

High strength iron shell, IP30 protection

Industrial 4 class design

Redundant 24VDC power supply input(12- 48VDC)

-40- 75℃ working temperature

DIN-rail, wall mounting installation

Panel Layout

IES605-2D series


background image

Back view

Top and below view

IES605-2DRS-232-P(12/48VDC)

1. PWR1/PWR2 power supply

2. Ground screw

3. Relay output terminal block

4. DIP switch (4 bits)

5. DIN-Rail

6. LED indicator

7. 10/100Base-TX RJ45 port

8. RS-232 port

IES605-2DIRS-485-P(12/48VDC)

1. PWR1/PWR2 power supply

2. Ground screw

3. Relay output terminal block

4. DIP switch (4 bits)

5. DIN-Rail

6. LED indicator

7. 10/100Base-TX RJ45 port

8. RS-485/422 port


background image

IES605-1F-2DRS-232-P(12/48VDC)

1. PWR1/PWR2 power supply

2. Ground screw

3. Relay output terminal block

4. DIP switch (4 bits)

5. DIN-Rail

6. LED indicator

7. 100Base-FX fiber port

8. RS-232 port

9. 10/100Base-TX RJ45 port

IES605-1F-2DIRS-485-P(12/48VDC)

1. PWR1/PWR2 power supply

2. Ground screw

3. Relay output terminal block

4. DIP switch (4 bits)

5. DIN-Rail

6. LED indicator

7. 100Base-FX fiber port

8. RS-485/422 port

9. 10/100Base-TX RJ45 port

IES605-2F-2DRS-232-P(12/48VDC)

1. PWR1/PWR2 power supply

2. Ground screw

3. Relay output terminal block

4. DIP switch (4 bits)

5. DIN-Rail

6. LED indicator


background image

7. 100Base-FX fiber port

8. RS-232 port

9. 10/100Base-TX RJ45 port

IES605-2F-2DIRS-485-P(12/48VDC)

1. PWR1/PWR2 power supply

2. Ground screw

3. Relay output terminal block

4. DIP switch (4 bits)

5. DIN-Rail

6. LED indicator

7. 100Base-FX fiber port

8. RS-485/422 port

9. 10/100Base-TX RJ45 port

Appearance and dimension

Unit (mm)

Front view

Back view


background image

Power supply input

Vertical view

Top view

IES605-2D series provide 4 bits industry terminal block (V1-,

V1+, V2-, V2+)), V-, V+ is 12~48VDC power supply input.

IES605-2D series DC power supply input supported

redundancy function, provided PWR1 and PWR2 power input,

can use for single, and can connect 2 separately power supply

system, use 1 pair terminal block connect the device at the same

time. If one of the power system broke, the device can work

un-interruptible. built-in over current protection, Reverse

connection protection

Relay connection

Vertical view

Top view

The relay owns two contacts of the terminal block on the top

panel of IES605-2D series. It is used to detect both power failure

and port failure. The two wires attached to contacts form an open

circuit when:

(1) IES605-2D series has lost power supply from one of the

DC power inputs.

(2)

One of the ports is failure.

DIP switch

Top panel provided 4 bits DIP switch to do function


background image

configure(OFF is default factory),1 and 2 keep for future function.

3 is for upgrade. 4 is recovery default factory. Please power off

and power on when you change the status of DIP switch.

Communication connector

10/100BaseT(X) Ethernet port

The pinout of RJ45 port display as below, connect by UTP or

STP. The connect distance is no more than 100m. 100Mbps is

used 120Ωof UTP 5 , 10Mbps is used 120Ωof UTP 3,4,5.

RJ 45 port support automatic MDI/MDI-X operation. can

connect the PC, Server, Converter and HUB .Pin 1,2,3,6

Corresponding connection in MDI. 1→3, 2→6, 3→1, 6→2 are

used as cross wiring in the MDI-X port of Converter and HUB.

10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin

in the table as below.

NO.

MDI signal

MDI-X signal

1

TX+

RX+

2

TX-

RX-

3

RX+

TX+

6

RX-

TX-

4, 5, 7, 8

Note:“TX±”Transmit Data±,“RX±”Receive Data±,“” Not Use。

MDI (straight-through cable)

1

8


background image

MDI-X (Cross over cable)

MDI/MDI-X auto connection makes IES605-2D easy to use

for customers without considering the type of network cable.

100Base-FX Fiber port

100Base-FX full-duplex SM or MM port, SC/ST/FC type .The

fiber port must be used in pair, TX (transmit) port connect remote

switch’s RX (receive) port; RX (receive) port connect remote

switch’s TX (transmit) port.

The optical fiber connection supports the line to instruct

enhance the reliability of network effectively

.

Suppose: If you make your own cable, we suggest labeling the

two sides of the same line with the same letter (A-to-A and B-to-B,

shown as below, or A1-to-A2 and B1-to-B2).

RS-232 port


background image

PIN

RS-232

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

9

-

DB9 male (RS-232)

RS-485/422 port:

PIN

RS-422

RS-485

1

T+

D+

2

T-

D-

3

GND

/

4

R+

/

5

R-

/

RS-485/422

LED indicator

IES605-2D series LED indicator light on the front panel .the

function of each LED is described in the table as below:


background image

System status LED

LED

Indicator

Description

PWR1

ON

P1 connection regularly

OFF

P1 Power supply have no connection or

unwonted

PWR2

ON

P2 connection regularly

OFF

P2 Power supply have no connection or

unwonted

Alarm

ON

Power, port have alarm

OFF

Power, port have no alarm

Run

ON

Device unwonted

Blinking

Device working steadily, Blinking per

second

Link/Act

ON

Established effective

network connection

Blinking

Network in activity status

OFF

Did not establish effective

network connection

TX

Blinking

Transmit data unwonted

OFF

Transmit data wonted

RX

Blinking

Receive data unwonted

OFF

Receive data wonted

Installation

Before installation, confirm that the work environment meet the

installation require, including the power needs and abundant space.

Whether it is close to the connection equipment and other

equipments are prepared or not.

1. Avoid in the sunshine, keep away from the heat fountainhead or

the area where in intense EMI.

2. Examine the cables and plugs that installation requirements.


background image

3. Examine whether the cables be seemly or not (less than 100m)

according to reasonable scheme.

4. Screw, nut, tool provide by yourself.

5. Power: redundant 12-48VDC o power input

6. Environment: working temperature -40~75℃

Relative humidity 5%~95%

DIN rail installation

In order to use in industrial environments expediently, IES605-2D

series adopt 35mm DIN-Rail installation, the installation steps as

fellows:

1. Examine the DIN-Rail attachment

2. Examine DIN Rail whether be firm and the position be

suitability or not.

3. Insert the top of the DIN-Rail into the slot just below the stiff

metal spring.

4. The DIN-Rail attachment unit will snap into place as shown

below.

Wiring Requirements

Cable laying need to meet the following requirements,

1. It is needed to check whether the type, quantity and

specification of cable match the requirement before cable

laying;

2. It is needed to check the cable is damaged or not, factory

records and quality assurance booklet before cable laying;

3. The required cable specification, quantity, direction and


background image

laying position need to match construction requirements,

and cable length depends on actual position;

4. All the cable cannot have break-down and terminal in the

middle;

5. Cables should be straight in the hallways and turning;

6. Cable should be straight in the groove, and cannot beyond

the groove in case of holding back the inlet and outlet holes.

Cables should be banded and fixed when they are out of the

groove;

7. User cable should be separated from the power lines.

Cables, power lines and grounding lines cannot be

overlapped and mixed when they are in the same groove

road. When cable is too long, it cannot hold down other

cable, but structure in the middle of alignment rack;

8. Pigtail cannot be tied and swerved as less as possible.

Swerving radius cannot be too small (small swerving causes

terrible loss of link). Its banding should be moderate, not too

tight, and should be separated from other cables;

9. It should have corresponding simple signal at both sides

of the cable for maintaining.

Specification

Technology

Standard: IEEE802.3, IEEE802.3u, IEEE 802.3x,

Protocol: ARP, ICMP, TCP, UDP, DHCP, DNS, HTTP,

SW-Ring

TM

Flow control: IEEE802.3x, back pressure control

Function

Function: SW-RingTM, Broadcast storm control, flow statistics,

upgrade online, up and download configuration file, user name

access system.

SW-Ring

TM

: Single, Couple, Chain, Dual homing ring.

Serial device server: 4 port serial device sever, each port

Support 4pcs TCP or UDP session connection


background image

Interface

100M Ethernet: 10/100Base-TX self-adapt RJ45 port.

100M fiber port: 100Base-FX (SC/ST/FC)

Alarm port: 2 bit 7.62mm terminal block,

1 channel relay alarm output

Serial

RS-232 signal: TXD, RXD, RTS, CTS, DTR, DSR, GND

RS-422 signal: T+, T-, R+, R-, GND

RS-485 signal: D+, D-, GND

Parity: None, Even, Odd, Space, Mark

Data bit: 5bit, 6bit, 7bit, 8bit

Band rate; 300~115200bps

Direction control: RS485 side adopt ADDC technology, auto

detect and control data transfer direction

Loading: RS-485/422 side support 32 nodes loop back

Protection: 2KV isolation, 15KV static protection.

Connector: RS232: DB9 male, RS485/4225 bit terminal block

Transfer distance

Twisted cable: 100m (CAT5/CAT5e)

Multi mode fiber: 1310nm,2/5Km

Single mode fiber: 1310nm, 20/40/60Km

1550nm, 80/100/120Km

RS-485/422: 1200m

RS-232: 15m

Exchange attribute:

100M transmit speed: 148810pps

Transfer: Store and forward

System exchange bandwidth: 1.2G

Buffer memory: 1MKbits

Support 2K MAC address table

LED indicator

Power supply indicator: PWR1, PWR2

Alarm indicator: Alarm


background image

System indicator: Run

Ethernet port indicator: Link/Act(1-5)

Serial port indicator: TX (1-2), RX (1-2)

Power supply

Input voltage: 24VDC (12-48VDC)

Terminal block: 4 bits 7.62mm terminal block

IES605-2D(RS-232)-P(12/48VDC)

None load consumption: 0.9W@24VDC

Full load consumption: 1.6 W@24VDC

IES605-2DI(RS-485)-P(12/48VDC)

None load consumption: 1.3W@24VDC

Full load consumption: 1.9 W@24VDC

IES605-1F-2D(RS-232)-P(12/48VDC)

None load consumption: 1.5W@24VDC

Full load consumption: 2W@24VDC

IES605-1F-2DI(RS-485)-P(12/48VDC)

None load consumption: 1.7W@24VDC

Full load consumption: 2.4W@24VDC

IES605-2F-2D(RS-232)-P(12/48VDC)

None load consumption: 2.2W@24VDC

Full load consumption: 2.3W@24VDC

IES605-2F-2DI(RS-485)-P(12/48VDC)

None load consumption: 2.4W@24VDC

Full load consumption: 2.7W@24VDC

Support dual redundant power supply

Support inside over-current 4.0A protection

Mechanical

Shell: IP30, high strength iron shell.

Installation: DIN Rail


background image

Dimension(W×H×D): 136mm×52mm×105mm

Weight: 900g

Environmental

Operating Temperature: -45°C to 75°C

Storage Temperature: -45°C to 85°C

Relative Humidity: 10 to 95% (non-condensing)

Standard

EMI: FCC Part 15, CISPR (EN55022) class A

EMS: EN61000-4-2 (ESD), Level 4

EN61000-4-3(RS), Level 3

EN61000-4-4 (EFT), Level 4

EN61000-4-5 (Surge), Level 4

EN61000-4-6(CS), Level 3

EN61000-4-8(PFM), Level 5

Shock: IEC 60068-2-27

Free fall: IEC 60068-2-32

Vibration: IEC 60068-2-6

Certification

CE, FCC, RoHS, UL508 (Pending)

Warranty

Warranty time: 5 years