IIIIntroduction

ntroduction

ntroduction

ntroduction::::

IES608-2F series are a type of plug-and-play industrial managed

redundant Ethernet switch, which supports 6-port 10/100Base-T(x)

and 2-port 100Base-Fx. The 7 and 8 ports(100Base-Fx) are used to

establish SW-Ring for the purpose accomplishing redundancy for

Ethernet ring network (self-recovery time <20ms) to enhance the

reliability of the network.

Furthermore, IES608-2F series can also support numerous

intelligent network management functions, including QoS, VLAN,

Port Trunking, velocity configuration and alarm enabling functions.

To

satisfy applications in different industrial environments,

IES608-2F series can also provide wide temperature type in

accommodation with limit temperature (-40 ~ 70°C).

Packing

Packing

Packing

Packing L

L

L

List

ist

ist

ist::::

The IES608-2F switch is shipped with following items.

1. Ethernet switch IES608-2F (plus terminal block)×1

2. Hardware Installation Guide ×1

3. CD-ROM with Windows Utility ×1

4. Product Warranty Statement ×1

5. RJ45 to DB9 Console port cable ×1

6. DIN-Rail setting fittings(wall mounting for optional)

F

F

F

Features:

eatures:

eatures:

eatures:

Designed

Designed

Designed

Designed for

for

for

for Industrial

Industrial

Industrial

Industrial Applications

Applications

Applications

Applications

1. Dual power backup, Relay output warning for power failure and

port break alarm

2. Port link, ring fault/abnormity alarm indication

3. IP 30 protection, rugged high-strength metal case

4. Redundant 24VDC power input(12V~36VDC)Operating

5. DIN-Rail or panel mounting ability

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

Advanced

Advanced

Advanced

Advanced Industrial

Industrial

Industrial

Industrial Ethernet

Ethernet

Ethernet

Ethernet Networking

Networking

Networking

Networking Capability

Capability

Capability

Capability

1. Store and forward.8k address. Support MAC address filtrate

struction

2. SW-Ring(recovery time < 20 ms at full load)

3. Port-based VLAN, IEEE 802.1Q VLAN to ease network

planning

4. Port Trunking for optimum bandwidth utilization

5. Lock port function for blocking unauthorized access based on

MAC address

6. Port mirroring for online debugging

7. Bandwidth management prevents unpredictable network status

P

P

P

Panel

anel

anel

anel Layout:

Layout:

Layout:

Layout:

6

6

6

6 TP

TP

TP ports

ports

ports and

and

and 2

2

2 fiber

fiber

fiber ports

ports

ports (IES608-2F)

ffffront

ront

ront

ront panel

panel

panel

panel

Note:left is SC, right is ST, the same as the picture for single-mode

and multi-mode.

(IES608-2F)

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

1.

Grounding screw

2. PWR1/PWR2 input, relay output

6 bit terminal block

3. DIP switch: DOWNLOAD PROGRAM,

RESUME DEFAULT, SW-Ring Enabled

4. DOWNLOAD PROGRAM port

(RS-232, RJ45)

5. Heat dissipation orifices

6. DIN-Rail locating kit

top

top

top

top panel

panel

panel

panel

7. Screw hole for wall mounting kit

8. 10/100Base-T(X) port

9. Corporation, product information

10. Run indication LED

11. Power input PWR1 LED

12. Power input PWR2 LED

13. System alarm indication LED

14. Fiber port 8 indication LED

15. Fiber port 7 indication LED

16. 100Base-FX port

back

back

back

back panel

panel

panel

panel

Units

Units

Units

Unitsmm

mm

mm

mm

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

Communication

Communication

Communication

Communication connector

connector

connector

connector::::

IES608-2F series have 8x10/100BaseT(X) Ethernet ports(RJ45) and

2x100BaseFX (SC/ST connector, optional) fiber ports.

10/100BaseT(X)

10/100BaseT(X)

10/100BaseT(X)

10/100BaseT(X) Ethernet

Ethernet

Ethernet

Ethernet port

port

port

port

The pinout of RJ45 port display as below, connect by UTP or

STP. The connect distance is no more than 100m. 100Mbps is used

100Ωof UTP 5 , 10Mbps is used 100Ωof UTP 3,4,5.

RJ 45 port support automatic MDI/MDI-X operation. can

connect the PC, Server, Converter and HUB .Pin 1,2,3,6

Corresponding connection in MDI. 1→3,2→6,3→1,6→2 are used

as cross wiring in the MDI-X port of Converter and HUB.

10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin

in the table as below.

NO.

NO.

NO.

NO.

MDI

MDI

MDI

MDI signal

signal

signal

signal

MDI-X

MDI-X

MDI-X

MDI-X signal

signal

signal

signal

1

TX+

RX+

2

TX-

RX-

3

RX+

TX+

6

RX-

TX-

4,5,7,8

Note: “TX±”transmit data±, “RX±”receive data±, “—”not use

MDI(straight-through

MDI(straight-through

MDI(straight-through

MDI(straight-through cable)

cable)

cable)

cable)

1

8

1

8

R J 4 5

T X +

T X -

T X -

R X +

R X +

R X -

R X -

T X +

2

3

6

1

2

3

6

1

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

MDI-X

MDI-X

MDI-X

MDI-X((((Cross

Cross

Cross

Cross over

over

over

over cable

cable

cable

cable))))

100BaseFX

100BaseFX

100BaseFX

100BaseFX port

port

port

port

100Base-FX full-duplex SM or MM port , SC/ST type .The fiber

port must be used in pair, TX (transmit) port connect remote

switch’s RX(receive) port; RX(receive) port connect remote

switch’s TX(transmit) port.

The optical fiber connection supports the line to instruct enhance

the reliability of network effectively

.

Suppose

Suppose

Suppose

Suppose: If you make your own cable, we suggest labeling the two

sides of the same line with the same letter (A-to-A and B-to-B,

shown as below, or A1-to-A2 and B1-to-B2).

1

8

R J 4 5

T X +

T X -

T X -

R X +

R X +

R X -

R X -

T X +

2

3

6

1

6

1

2

3

(T X -)

(R X + )

(R X -)

(T X + )

(T X + )

(T X -)

(R X + )

(R X -)

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

LED

LED

LED

LED Indicator

Indicator

Indicator

Indicator::::

LED indictor light on the front panel of IES608-2F Series .the

function of each LED is described in the table as below.

System

System

System

System indication

indication

indication

indication LED

LED

LED

LED

LED

LED

LED

LED

State

State

State

State

Description

Description

Description

Description

PWR1

PWR1

PWR1

PWR1

ON

Power is being supplied to

power input PWR1 input

OFF

Power is not

not

not

not being supplied to

power input PWR1 input

PWR2

PWR2

PWR2

PWR2

ON

Power is being supplied to

power input PWR2 input

OFF

Power is not

not

not

not being supplied to

power input POWER2 input

Alarm

Alarm

Alarm

Alarm

ON

When the alarm is enabled,

power and the port’s link is

inactive.

OFF

Power and the port’s link is

active, not

not

not

not alarm

Run

Run

Run

Run

ON/OFF

Switch is unwonted

Blinking

Switch is active

100BaseFX

100BaseFX

100BaseFX

100BaseFX port

port

port

port state

state

state

state LED

LED

LED

LED (7,

(7,

(7,

(7, 8)

8)

8)

8)

Link

Link

Link

Link

(IES608-2F)

ON

FX port is active

Blinking

Data is being transmitted

OFF

FX port is inactive

10/100BaseT(X)

10/100BaseT(X)

10/100BaseT(X)

10/100BaseT(X) Ethernet

Ethernet

Ethernet

Ethernet port

port

port

port state

state

state

state LED

LED

LED

LED

10M/100M

10M/100M

10M/100M

10M/100M

(yellow)

ON

100Mbps is active (100Base-TX)

OFF

10Mbps is active (10Base-T)

Link/ACT

Link/ACT

Link/ACT

Link/ACT

(green)

ON

TP port is active

Blinking

Data is being transmitted

OFF

TP port is inactive

(IES608-2F)

(IES608-2F)

(IES608-2F)

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

Relay

Relay

Relay

Relay contact

contact

contact

contact::::

The relay consists of the two middle contacts of the terminal block

on IES608-2Fseries top panel. The two terminal block connector are

used to detect both power faults and port faults. The two wires

attached to the Fault contacts form an open circuit when:

(1) IES608-2F series have lost power from one of the DC power

inputs, or (2) One of the ports for which the corresponding Port

alarm DIP Switch is set to ON is not properly connected.

If neither of these two conditions occur, the alarm circuit will be

closed.

Power

Power

Power

Power Input

Input

Input

Input::::

IES608-2Fseries have redundant power input, provides two terminal

block (3 bits) for PWR1 and PWR2 input. The redundant power can

be used single and used two self-governed power to supply to the

system, PWR1 and PWR2 input at the same time, when neither of

these two power fails, the other power acts as a backup, and

automatically supplies power needs, ensure running

Ethernet

reassuring .

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

Switch

Switch

Switch

Switch Settings:

Settings:

Settings:

Settings:

Provide 4 bit switch for function setting (ON is enable): 1(ISP) is

DOWNLOAD PROGRAM,2 is RESUME DEFAULT,3 is SW-Ring

Enabled ,4 is blank (NC).When the switch is setup, must be restart.

DOWNLOAD

DOWNLOAD

DOWNLOAD

DOWNLOAD PROGRAM

PROGRAM

PROGRAM

PROGRAM port

port

port

port::::

IES608-2F series provide one DOWNLOAD PROGRAM port

(RJ45 type), on the top panel, manage the system with PC by

RJ45-DB9F adapter.

Installation

Installation

Installation

Installation

Before installation, confirm that the work environment meet the

installation require, including the power needs and abundant space.

whether it is close to the connection equipment and other

equipments are prepared or not.

Installation

Installation

Installation

Installation require

require

require

require as

as

as

as below

below

below

below

1. Avoid in the sunshine, keep away from the heat fountainhead or

the area where in intense EMI.

2. Examine the cables and plugs that installation requirements.

3. Examine whether the cables be seemly or not (less than 100m)

according to reasonable scheme.

4. Screw, nut ,tool provide for yourself.

5.Power need: Redundant, dual 24VDC power inputs(12~36DC)

6. Environment: -40°C to 75°C

Storage Temperature: -45°C to 85°C

Relative humidity 10% to 95%

DIN-Rail

DIN-Rail

DIN-Rail

DIN-Rail Installation

Installation

Installation

Installation

In order to use in industrial environments expediently, IES608-2F

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

series adopt 35mm DIN-Rail installation, the installation steps as

fellows:

1. Examine the DIN-Rail attachment

2. Examine DIN Rail whether be firm and the position be

suitability or not.

3. Insert the top of the DIN-Rail into the slot just below the stiff

metal spring.

4. The DIN-Rail attachment unit will snap into place as shown

below.

Wiring

Wiring

Wiring

Wiring Requirements

Requirements

Requirements

Requirements

Be sure to disconnect the power cord before installing and/or wiring

your Ethernet Switch.

Calculate the maximum possible current in each power wire and

common wire. Observe all electrical codes dictating the maximum

current allowable for each wire size. If the current goes above the

maximum ratings, the wiring could overheat may causing serious

damage to your equipment. You should also pay attention to the

following items:

1. Use separate path to route wiring for power and devices. If power

wiring and device wiring paths must cross make sure the wires

are perpendicular at the intersection point.

2. NOTE: Do not run signal or communications wiring and power

wiring in the same wire conduit. To avoid interference, wires

with different signal characteristics should be routed separately.

3. You can use the type of signal transmitted through a wire to

determine which wires should be kept separate. The rule of

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

thumb is that wiring that shares similar electrical characteristics

can be bundled together.

4. Keep input and output wiring separated. It is strongly advised

that you label wiring to all devices in the system when necessary.

Specifications:

Specifications:

Specifications:

Specifications:

Interface

Interface

Interface

Interface

RJ45 Ports: 10/100BaseT(X) auto connection, Full /Half duplex or

force work mode, and support MDI/MDI-X connection

Fiber Ports: 100BaseFX ports (SC/ST connector, optional)

Single-mode: 20, 40,60, 80, 120Km,optional

Multi-mode: 2,5Km,optional

Wavelength: 850nm,1310 nm,1550nm

DOWNLOAD PROGRAM Port: Based serial network management

(RS-232), RJ45

Alarm output interface: One relay alarm output. Support

power,

port link and ring network alarm .

Indicator:

Port

link,

ring

fault/abnormity

alarm

indication

10M/100M Rate, run indication

Technology

Technology

Technology

Technology

Standards: IEEE802.3 for 10BaseT, IEEE802.3x for Flow Control,

IEEE802.3u for 100BaseTX and 100BaseFX, IEEE802.1Q for

VLAN Tagging, IEEE802.1p for Class of Service

Transmit Rate: 148810pps

Max Rate of Filtrate: 148810pps

Processing type: Store and Forward

System exchange bandwidth: 4.8G

Support 8K MAC address

Port-Based VLAN

R

R

R

Relay

elay

elay

elay

Max voltage: DC30V

Max current input: 1A

Power

Power

Power

Power

Input Voltage: 24VDC (12VDC~36VDC)

Overload Current Protection

Support dual power backup

 


background image

Your Serial and Data Communications Expert

Shenzhen 3onedata Technology Co.,Ltd

Support dual power alarm input

Mechanical

Mechanical

Mechanical

Mechanical

Dimensions: 136mm×52mm×105mm (H×W×D)

Casing: IP30 protection, metal case

Installation: DIN-Rail, Wall Mounting

Weight: 800g

Environmental

Environmental

Environmental

Environmental

Operating Temperature: -40 to 70°C

Storage Temperature: -45°C to 85°C

Ambient Relative Humidity: 10 to 95% (non-condensing)

Approvals

Approvals

Approvals

Approvals

Warranty:

Warranty:

Warranty:

Warranty: 5

5

5

5 years

years

years

years

Certifications:

Certifications:

Certifications:

Certifications:

Shenzhen

Shenzhen

Shenzhen

Shenzhen 3onedata

3onedata

3onedata

3onedata Technology

Technology

Technology

Technology Co.,Ltd

Co.,Ltd

Co.,Ltd

Co.,Ltd

Tel: +86-755-26702688

Fax: +86-755-26703485

www.3onedata.com

EMS: EN61000-4-2(ESD),

EN61000-4-3(RS),

EN61000-4-4(EFT),

EN61000-4-5 (Surge),

EN61000-4-6 (CS),

EN61000-4-8,

Shock: IEC 60068-2-27

Free Fall: IEC 60068-2-32

Vibration: IEC 60068-2-6

Level 4

Level 3

Level 4

Level 4

Level 3

Level 5

EMI:FCC Part 15, CISPR (EN55022) class A