  3M Occupational Health and Environmental Safety Division

3M

TM

WIBGET

TM

Heat Stress Monitor WB-300

WIBGET WB-300 User Manual

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

i    Dangers, warnings and cautions

     

3M

TM 

WIBGET

TM 

Heat Stress Monitor WB-300 User Manual

 Dangers, warnings and cautions

   Danger!

Failure to observe the following procedures may result in serious personal injury
•Thisinstrumentisnotintrinsicallysafe,donotuseinhazardouslocations.

   Warning!

Failure to observe the following procedures could damage the instrument

• Readthemanualbeforeoperation.

• Donotstoreintemperaturesexceeding100°C(212°F)

• Donotimmerseinliquids.

• Condensationmaydamageyourinstrument.

• Substitutionofcomponentsmayimpairtheaccuracyoftheinstrument.Repairshould

becompletedbyauthorizedservicepersonnelonly.

    Caution!

 General 

• Replacementof9-Valkalinebatteryonlyinanon-hazardouslocations.

• IfrechargingwithaNiHMBatterypack,rechargeonlyinanon-hazardousenvironment.

• Anon-condensingenvironmentisrequiredforpropermeasurements.

• Donotchargebatteryoutsidetherangeof0°Cto40°C(32°Fto104°F).

• Batteryrun-timemaybereducedwhenoperatingatlowerthan0°C(32°F)

temperatures.

    Intended Use 

TheWIBGETWB-300isintendedtomeasureenvironmentaltemperaturesforheat

stressanalysis.Consultyourcompany’ssafetyprofessionalforlocalstandards,orcall3M

at1-800-243-4630.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Table of Contents

UpandRunning.........................................................................................................................3

Checkwickandfillnaturalwetbulb..........................................................................................3

KeypadOperation......................................................................................................................4

Sensors .....................................................................................................................................5

NaturalWetBulbThermometer................................................................................................5

GlobeThermometer.................................................................................................................5

DryBulbThermometer.............................................................................................................5

Measurements...........................................................................................................................6

WetBulbGlobeTemperature...................................................................................................6

DisplayedData..........................................................................................................................6

Setup..........................................................................................................................................7

PlacingtheWB-300on-siteformonitoring/testing...................................................................7

OperationalCheck.....................................................................................................................8

PowerOptions...........................................................................................................................8

8

..........................................8

9

9

9

9

9

9

9

9

9

9

9

9

9

10

10

.......................................11

12

12

12

9-VAlkalineBatteryReplacement..........................................................................................

NiMHBatteryPack..............................................................................

AppendixA:Specifications......................................................................................................

Measurements..........................................................................................................................

Languages.................................................................................................................................

Housing......................................................................................................................................

Size............................................................................................................................................

Weight......................................................................................................................................

SensorTypes.............................................................................................................................

Accuracy...................................................................................................................................

OperatingTemperatureRange..................................................................................................

PowerOptions..........................................................................................................................

BatteryLife................................................................................................................................

ChargeTime(NiMHBatteryPack)...........................................................................................

SafetyApprovalsandSpecialConditions.................................................................................

AppendixB:HeatExposuresTables.......................................................................................

ACGIH......................................................................................................................................

PHELCurves(TotalExposureTimeinHours:Minutes).................. 

ProductInformation.................................................................................................................

Accessories.............................................................................................................................

Warranty..................................................................................................................................

Figures

Figure1:Wetbulbandmaintenance..........................................................................................4

Figure2:Keypadkeysidentified..................................................................................................5

Figure3:Sensorsidentified..........................................................................................................6

Figure4:Data/measurementscreenexamples..........................................................................7

Figure5:NiMHBatteryPack......................................................................................................9

iiTableofContents

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Up and Running

1. Ensurethewetbulb’swickisclean.Then,fillthereservoirwithdistilledwater.
2. PlacetheWB-300intheworkareainasafelocationapproximately3.5feetoff

theground.

3. TurntheinstrumentOnbypressingI/OEnterkey.

• Ifthebatteryvoltagedisplayedduringthepower-onsequenceislessthanorequalto

6.4volts,replaceorrechargethebatteries.

4. UsingtheArrowkeys,selectthedesiredmeasurement/parameterscreen.
5. Allow10minutesforthesensorstostabilizetotheenvironmentbeforetaking

readings.

Check wick and fill natural wet bulb

TheWB-300usesacottonwickimmersedintoareservoircontainingdistilledwater.Ordinary

tapwatershouldnotbeused,asthecontaminantsthatareleftbehindafterevaporationwill

shortenthelifeofthewickandcausehighreadings.Ifthewickisdiscoloreditshouldbe

replaced.Toreplacethewick,slidetheoldwickoffthetopofthesensor.Placeanewwickover

thesensor,makingsurethatthebottomofthewickisdowninthereservoir.

 

 

 

Figure 1:  Wet bulb and maintenance 

Filling wet bulb reservoir

1.Removereservoircoverandfillwithdistilledorde-ionizedwater.
2.Replacereservoircover.

Wick

Reservoircover

Reservoir

Up & Running 

1UpandRunning

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Keypad Operation

Theunitoperatesusingamembranekeypadwith4keys.Thekeyresponds

whenthekeyisreleasedwhileallotherkeysrespondwhenthekeyispressed.

I/OEnterkey

Keys

Explanation

I/O Enter

The         keyisusedtoturnonandofftheinstrumentandtoentersetup

changes.
Turning on:PressandreleasetheI/Oenterkeytopoweron.The

Instrumentname(WIBGET),revisionnumber,andbatteryinformation

appearsduringstart-up.
Turning off: HoldtheI/Okeydownwhileacount-down3-2-1occursinthe

lowerlefthandcornerofthedisplay.
Enter setup changes: WhileinSetupscreen,presstoenter(orselect)

setupchanges.

Setup

Thekeyallowschangingthesetupparameters.Twoparametersare

available:CelsiusorFahrenheitandlanguageselection.
Setup:  Presssetuptoaccesstheparameters.Usethearrowkeysto

switchbetweenthetwoparameters.Presstheenterkeytochangethe

parameters.Presssetupagaintoexit.

Up Arrow

Thekeychangeswhichitemsappearonthedisplay.Scrollsup.

Down Arrow

Thekeychangeswhichitemsappearonthedisplay.Scrollsdown.

Figure 2:  Keypad keys identified

 

 

 

       Down Arrow

UpArrow

Setupkey

 

 

Keypad 

 

 

2KeypadOperation

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Sensors 

Natural Wet Bulb Thermometer 

Thenaturalwetbulbthermometergivesanindicationoftheeffectsofhumidityonanindividual.

Relativehumidityandairflowaretakenintoaccountbymeasuringtheamountofevaporative

coolingtakingplaceatathermometercoveredwithamoistenedwick.TheWB-300usesa

cottonwickimmersedintoareservoircontainingdistilledwater.Ordinarytapwatershouldnot

beused,asthecontaminantsthatareleftbehindafterevaporationwillshortenthelifeofthewick

andcausehighreadings.Ifthewickisdiscoloreditshouldbereplaced.Toreplacethewick,

slidetheoldwickoffthetopofthesensor.Placeanewwickoverthesensor,makingsurethat

thebottomofthewickisdowninthereservoir.

Globe Thermometer 

Theglobethermometergivesanindicationoftheradiantheatexposureonanindividualdue

toeitherdirectlightorhotobjectsintheenvironment.Thisisaccomplishedbyplacinga

temperaturesensorinsideablackenedcoppersphereandmeasuringthetemperaturerise.The

WBGTindexisbasedontheresponseofa6inchdiameterglobe.TheWB-300usesa2inch

diameterglobeforafasterresponsetime.Thetemperatureofthe2inchglobeiscorrelated

tomatchthatofa6inchglobe.Asanoption,asensorarraywitha6inchdiameterglobeis

available.
Asanoption,asensorarraywitha6inchdiameterglobeisavailable.

Dry Bulb Thermometer 

Thedrybulbthermometermeasurestheambientairtemperature.Thismeasurementisusedin

theoutdoorWBGTcalculationwhenahighsolarradiantheatloadmaybepresent.Theseriesof

whiteplatessurroundingthesensorshielditfromradiantheat.

A.Globethermometer

B.Naturalwetbulbthermometer

C.Drybulbthermometer

A

B

C

Figure 3:  Sensors identified

Sensors 

3Sensors

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Measurements

TheWB-300portableheatstressmonitorcomputestheWetBulbGlobeTemperature(WBGT).

TheWBGTisanacceptedmeasurementfordeterminingtheheatstresslevelimposedonan

individualinagivenenvironment.
TheWB-300measuresthreeparameters:

Ambientordrybulbtemperature(DB)

Naturalwetbulbtemperature(WB)

Globetemperature(G)

Wet Bulb Globe Temperature 

TheWBGTisaweightedaverageofthethreetemperaturesensorsusingthefollowing

formulas:

WBGT(indoor)=0.7WB+0.3G(denotedas"WBGTi"onthedisplay)

WBGT(outdoor)=0.7WB+0.2G+0.1DB(denotedas"WBGTo"onthedisplay)

 

;

NOTE:  The resulting WBGTi/WBGTo can be compared to indices of  

work-rest regimens (or stay times) based upon the work loads.  

Please 

see Appendix B for published heat exposure tables.

Displayed Data

Whenpoweredon,thepreviouslyviewedmeasurementscreenwillbedisplayed.Toviewdata

screens,presstheorkeys.

Data Screens

ThefollowingfourscreensareviewablebypressingtheorkeysontheWB-300.

Wet/DryMeasurementscreen

GlobeMeasurementscreen

WBGTi/WBGToMeasurementscreen

Batteryscreen

Figure 4: Data/measurement screen examples

Measurements 

4Measurements

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Setup

Whilepoweredon,pressthesetupkeytochangethetemperatureunits(

o

F/

o

C)orthe

languagesettings(English,Spanish,French,Italian,orGerman),ifdesired.

Placing the WB-300 on-site for monitoring/testing

TheWB-300shouldbeplacedataheightof3.5feet(1.1m)forstandingindividualsor2

feet(.6m)forseatedindividuals.Tripodmountingisrecommendedtogettheunitaway

fromanythingthatmightblockradiantheatorairflow.A1/4"x20threadedbushingonthe

bottomoftheinstrumentallowsmountingtoastandardphotographictripod.Donotstand

closetotheunitduringsampling.
Makesurethatthewetbulbreservoirisfilledwithdistilledwaterandthatthecottonwick

iscleanandfullywetted.Afteraddingwaterorplacingtheunitinanewenvironment,

allowtenminutesfortheglobeandwetbulbreadingstostabilize.
Aseriesofdashesappearinthedisplayifoneofthefollowingoccur:

•Thetemperatureisoutsideofitsallowablerange

•Atemperaturesensorhasfailed

Operational Check

Averificationmodule,3MID:70071581246,maybeusedtochecktheoperationofthe

WB-300. Remove the top sensor bar and plug the verification module into the top of the

unit. With the WB-300 set to read in degrees Celsius, verify that the displayed readings

match those printed on the module within +/-0.5

o

C.

Ifthereadingsarenotwithinthe+/-0.5

o

Ctolerance,thenhavetheunitservicedand

calibrated.

Setup 

5Setup

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Figure 5:  NiMH Battery Pack

Power Options

Thereare3optionsforpoweringtheWB-300:a9-voltalkalinebattery,aNiMH(NickelMetal

Hydride)rechargeable6-cellbatterypack,andanACadapter.Adooronthebackoftheinstru-

mentallowstheuseraccesstothe9-voltbattery.Therechargeablebatterypackislocatedinside

oftheunit.Iftherechargeablebatterypackeverneedstobereplaced,itcanbeaccessedby

removingthescrewsfromthebottompaneloftheunit.
The2-positionswitchlocatedinthebatterycompartmentmustbesetbytheuserifthepower

supplymethodischanged.Theuppositionisforthe9-voltbattery.Thedownpositionallows

foreithertheACadapterortherechargeablebatteries.TheACadapterwilltricklechargethe

rechargeablebatteriesiftheyareinplaceoritwillsimplyallowforlinepoweroperationoftheunit.

9-V Alkaline Battery Replacement  

The9-voltbatteryshouldbereplacedortheNiMHbatterypackshouldberechargedwhenthe

voltagedropsbelow6.4volts.Thebatteryvoltageisdisplayedwhentheinstrumentisturned

on.Whileturnedon,thebatteryvoltagecanbedisplayedatanytimebypressingtheupor

downarrowkeystomovethroughthedisplayuntilthebatteryvoltagescreenappears.If,while

operating,thebatteryvoltagedropsbelow6.4volts,thedisplaywillautomaticallyswitchto

thedisplayshowingthebatteryvoltagealongwithalowbatterymessage.Afteralowbattery

occurs,theunitwillcontinuetooperateforapproximately8hours.Whenthebatteryvoltage

fallsto6.2voltsorbelow,theunitwillautomaticallyturnoff.

NiMH Battery Pack

 

TheNiMHrechargeablebatterypackischargedintheinstrumentusing120VACto9VDC

adapter.Adischargedbatterypackrequiresachargeof16hours.LeavingtheACadapter

pluggedinforextendedlengthsoftimeorwhenoperatingtheinstrumentwillnotharmthe

rechargeablebatteries.

NiMH Battery Pack

Toinstall,slideintocaseandplugin

connector as shown.

Power Options 

6PowerOptions

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Appendix A:  Specifications 

Measurements 

• Globe,drybulb,wetbulb,WBGTi,(WBGTindoor)andWBGTo(WBGToutdoor).

• TemperaturesgiveninCelsiusorFahrenheit.

Languages

English,French,Spanish,Italian,German.

Housing

Designedwaterresistanttoalightrainormist.Ifrainisfrequent,bestpracticewouldbeto

remotethesensorbarandkeeptheinstrumentsheltered.(Note:whentopsensorbaris

removed,anoptionalcablecanbeattachedtomeasureremotely.)

Size

Height9.2in(23.5cm);Width7.2in(18.3mm);Depth3.0in(7.5mm)

Dimensionsincludemountedsensorassembly.

Weight  

2.6lbs.(1.2kg)withmountedsensorassembly.

Sensor Types

Temperature:1000ohmplatinumRTD

Accuracy 

Temperature:+/-0.5

o

Cbetween0

o

Cto100

o

C(+/-0.9

Fbetween32

Fto212

o

F)

Operating Temperature Range

SensorAssembly:-5

o

Cto100

o

C(23

o

Fto212

o

F)

Electronics: -5

o

C to 60

o

C (23

F to 140

F)

Power Options 

9Valkaline,7.2VNiMHrechargeablepack(chargedintheunit),orACadapterwallpowercube(AC

adapter will power the unit or recharge the NiMH battery pack).

Battery Life 

9Valkaline:140hours

Rechargeable Nickel MetalHydride:300hours

Charge Time (NiMH Battery Pack) 

16hours(chargeintheunit)

Safety Approvals and Special Conditions

CEmark

CompliancewithEssentialHealthandSafetyRequirementshasbeenassuredbycompliancewith:

EN 50014 : 1997 and EN 50020 : 2002

The year of manufacture is determined bythethirdcharacterintheinstrument’sserialnumber.“A”

was manufactured in 2001, “B” in 2002, “C” in 2003, “D” in 2004 and so forth.

Specifications 

7AppendixA:Specifications

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Appendix B: Heat Exposures Tables

ACGIH

ScreeningCriteriaforHeatStressExposure.WBGTvaluesin

o

C.

• NOTE:accordingtotheACGIH’sguidelines,thetemperaturevaluesrepresentaworkand

restprocesswhichisexplainedinthestandards.PleaserefertotheACGIHTLV’sand

BEIsforspecificdetails.

Work and recovery 

(TLV )

Light

Moderate

Heavy

Very Heavy

75%to100%

31.0

28.0

26.0*

23.5*

50%to75%

31.0

29.0

27.5

25.5*

25%to50%

32.0

30.0

29.0

28.0

0%to25%

32.5

31.5

30.5

30.0

Work and recovery

(Action Limit)

Light

Moderate

Heavy

Very Heavy

75%to100%

28.0

25.0

22.5*

20.0*

50%to75%

28.5

26.0

24.0

22.5*

25%to50%

29.5

27.0

25.5

24.5

0%to25%

30.0

29.0

28.0

27.0

*ValuesnotspecifiedbyACGIHhavebeenestimatedforcontinuity.

Citedfrom"AmericanConferenceofGovernmentalIndustrialHygienists-ThresholdLimit

ValuesandBiologicalExposureIndicesfor2008";ReprintedwithpermissionfromACGIH

Appendix B 

8AppendixB:HeatExposuresTables

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

PHEL Curves (Total Exposure Time in Hours: Minutes)

WBGT (

o

F)  

I

II

III

IV

V

VI

80.0

>8:00

>8:00

>8:00

8:00

6:35

4:30

81.0

>8:00

>8:00

>8:00

8:00

6:35

4:30

82.0

>8:00

>8:00

8:00

7:05

5:25

3:40

83.0

>8:00

8:00

7:45

6:25

4:55

3:20

84.0

>8:00

8:00

7:05

5:55

4:30

3:05

85.0

8:00

7:45

6:30

5:20

4:05

2:50

86.0

8:00

7:05

5:55

4:55

3:45

2:35

87.0

7:25

6:30

5:25

4:30

3:25

2:20

88.0

6:45

5:55

4:55

4:05

3:10

2:10

89.0

6:10

5:25

4:30

3:45

2:50

2:00

90.0

5:40

5:00

4:10

3:25

2:40

1:50

91.0

5:15

4:35

3:50

3:10

2:25

1:40

92.0

4:50

4:10

3:30

2:55

2:15

1:30

93.0

4:25

3:50

3:15

2:40

2:00

1:25

94.0

4:05

3:35

3:00

2:25

1:50

1:15

95.0

3:45

3:15

2:45

2:15

1:45

1:10

96.0

3:25

3:00

2:30

2:05

1:35

1:05

97.0

3:10

2:45

2:20

1:55

1:25

1:00

98.0

2:55

2:35

2:10

1:45

1:20

0:55

99.0

2:40

2:20

2:00

1:40

1:15

0:50

100.0

2:30

2:10

1:50

1:30

1:10

0:45

101.0

2:20

2:00

1:40

1:25

1:05

0:45

102.0

2:10

1:50

1:35

1:15

1:00

0:40

103.0

2:00

1:45

1:25

1:10

0:55

0:35

104.0

1:50

1:35

1:20

1:05

0:50

0:35

105.0

1:40

1:30

1:15

1:00

0:45

0:30

106.0

1:35

1:25

1:10

0:55

0:45

0:30

107.0

1:30

1:15

1:05

0:50

0:40

0:25

108.0

1:20

1:10

1:00

0:50

0:35

0:25

109.0

1:15

1:05

0:55

0:45

0:35

0:25

9PHELCurves

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

 Product Information

WIBGETWB-300HeatStressMonitorkit,includes9Valkalinebattery,replacementwicks,

waterbottle,verificationmodule,storagecase,andusermanual.(3MID:70-07160781-9)

Accessories

Product No.

Description

3M ID

056-795

3M

TM

Sensorarraywith2inchglobe(oneincluded)

70-0715-8658-3

056-780

3M

TM

Sensorarraywith6inchglobe(oneincluded)

70-0715-8656-7

015-910

3M

TM

120VACto9VDCtransformer/poweradapter

70-0715-8174-1

015-680

3M

TM

220VACto9VDCtransformer/poweradapter

70-0715-8507-2

059-045

3M

TM

Tripod

70-0715-8374-7

056-679

3M

TM

Replacementwicks

70-0715-8373-9

053-923

3M

TM

Verificationmodule

70-0715-8124-6

056-068

3M

TM

2ozwaterbottle

70-0715-8371-3

W

arranty

3M™WIBGET™WB-300LIMITEDWARRANTY.

3MwarrantstheWIBGETWB-300willbefreefromdefectivematerialsandworkmanship

for one year 

from date of purchase

 

(

indicatedonthesalesreceipt),provideditismaintainedandusedinaccordance

with3M™instructionsand/orrecommendations.Ifanycomponentbecomesdefectiveduringthewarranty

period,itwillbereplacedorrepairedfreeofcharge.Thiswarrantydoesnotapplytounitsthathavebeen

alteredorhadrepairattempted,orthathavebeensubjectedtoabuse,accidentalorotherwise.Theabove

warrantyisinlieuofallotherexpresswarranties,obligationsorliabilities.THEIMPLIEDWARRANTIESOF

MERCHANTABILITYANDFITNESSFORPARTICULARPURPOSEARELIMITEDTOoneyearFROMTHE

PURCHASEDATE. 3M™shallnotbeliableforanyotherwarranty,expressorimplied,arisingoutofor

relatedtotheappropriateuseofenvironmentaltemperaturemeasurementdataforheatstressrelatedissues.

Manufactureroritsagent’sliabilityshallbelimitedtoreplacementorrepairassetforthabove.Buyer’ssole

andexclusiveremediesarereturnofthegoodsandrepaymentoftheprice,orrepairandreplacementof

defectivegoodsorparts.

 

 

10ProductInformation

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

 


background image

Pleaserecycle.PrintedinU.S.A.

3MandWIBGETaretrademarksof3M

UsedunderlicenseinCanada

©20113MCompany

Allrightsreserved.

34-8706-7556-7

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com