Installer: Please leave this manual with owner/operator.

Dual/Triple Manifold Water Filtration  

Systems Instruction Manual 

 

High Flow Series Water Filtration Systems

3M

TM

 Water Filtration Products

 


background image

3M

 

Water Filtration Products

Table of Contents

Safety Information .......................................................................................................................................2

Warning Statements ....................................................................................................................................2

Caution/Important Notes ..............................................................................................................................3

Inlet and Outlet Connections ........................................................................................................................3  

Product Dimensions ....................................................................................................................................4

How to Use “Push-in” Connectors ................................................................................................................5

How to Use “Inlet/Outlet” Fitting/Retention Clip ............................................................................................5

Equipment Installation .................................................................................................................................5

Equipment Start-up Procedure  ....................................................................................................................6

Cartridge Change-out Procedure ..................................................................................................................7

Troubleshooting ...........................................................................................................................................7

Parts Listing ................................................................................................................................................8

Limited Warranty ........................................................................................................................................10

SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation.  Retain 
these instructions for future reference.

Intended Use: 
The manifolds and water filtration systems are intended for use in filtering potable water in the foodservice industry 
and have not been evaluated for other uses. These systems are installed at the point of use and must be installed as 
specified in the installation instructions. 

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or 
serious injury and/or property damage.

CAUTION

       

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate 
injury and/or property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking:
 

 tDo not allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with the ingestion of contaminants:
 

tDo not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

      before or after the system.  Systems certified for cyst reduction may be used on disinfected water that

may contain filterable cysts. EPA Establishment #10350-MN-007 and/or # 070595-CT-001.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric 
wiring or water pipes in the area of installation:
 tDo not install near electric wiring or piping which may be in path of a drilling tool when selecting the  
      position to mount the filter bracket.

To reduce the risk of physical injury:
 t%FQSFTTVSJ[FTZTUFNBTTIPXOJONBOVBMQSJPSUPDBSUSJEHFSFNPWBM

To reduce the risk associated with back strain:
 t'PMMPXTBGFMJGUJOHQSPDFEVSFT

2

 


background image

3

Inlet and Outlet Connections 

 

The water inlet is on the left side rear and the outlet is on the right side front and are identified with labels. The  

 

fitting size is 

¾” NPT (Male). A built-in check valve (non-return) is incorporated into the outlet.

To reduce the risk associated with property damage due to water leakage:
 

t3FBEBOEGPMMPXUse Instructions before installation and use of this system.

 t*OTUBMMBUJPOBOE6TFMUST comply with all state and local plumbing codes.
 tProtect from freezing, remove filter cartridge when temperatures are expected to drop below 40°F (4.4°C).
 

t%POPUJOTUBMMon hot water supply lines. The maximum operating water temperature of this filter system is 

100°F (37.8°C).

 

tDo not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa),   

       you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check 

 your water pressure.

 

tDo not install where water hammer conditions may occur. If water hammer conditions exist, you must install a    

        water hammer arrester.  Contact a plumbing professional if you are uncertain how to check for this condition.
 

tDo not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic    

       plumbing.
 t0OQMBTUJDmUUJOHTOFWFSVTFQJQFTFBMBOUPSQJQFEPQF6TF15'&UISFBEUBQFonly, pipe dope properties may
       deteriorate plastic.
 

t5BLFDBSFXIFOVTJOHQMJFSTPSQJQFXSFODIFTUPUJHIUFOQMBTUJDmUUJOHTBTEBNBHFNBZPDDVSJGPWFSUJHIUening

 occurs.

 

tDo not install in direct sunlight or outdoors.

 tDo not install near water pipes which will be in path of a drilling tool when selecting the position to mount 
       the bracket.
 

t.PVOUmMUFSJOTVDIBQPTJUJPOBTUPQSFWFOUJUGSPNCFJOHTUSVDLCZPUIFSJUFNTVTFEJOUIFBSFBPGJOTUBMMBUJPO

 t&OTVSFUIBUUIFMPDBUJPOBOEGBTUFOFSTXJMMTVQQPSUUIFXFJHIUPGUIFTZTUFNXIFOJOTUBMMFE
 t&OTVSFBMMUVCJOHBOEmUUJOHTBSFTFDVSFBOEGSFFPGMFBLT

 t5IFEJTQPTBCMFmMUFSDBSUSJEHFMUST be replaced every 12 months, at the rated capacity or sooner if a noticeable 

reduction in flow rate occurs.

CAUTION

IMPORTANT NOTES

t'BJMVSFUPGPMMPXJOTUSVDUJPOTXJMMWPJEXBSSBOUZ
 t"MMPXBNJOJNVNPGwDNDMFBSTQBDFVOEFSmMUFSUPGBDJMJUBUFDBSUSJEHFDIBOHF
 t*OTUBMMXJUIUIFJOMFUBOEPVUMFUQPSUTBTMBCFMFE.BLFTVSFOPUUPSFWFSTFDPOOFDUJPOT
 t4PNFMPDBMDPEFTNBZSFRVJSFUIFVTFPGBMJDFOTFEQMVNCFSPSDFSUJmFEJOTUBMMFSXIFOEJTSVQUJOHBQPUBCMF

water line.

 


background image

4

Dual Manifold Filtration System
Product Dimensions

5 3/8 in

(13.5 cm)

16 7/8in

(42.9 cm)

To Remove Cartridge

3 in (7.62 cm) Minimum

HF9X Series 

Cartridge

24 1/16"

(63.66 cm)

HF6X Series 

Cartridge

18 1/16"

(45.9 cm)

HF4X Series 

Cartridge

15 1/16"

((38.3 cm)

Triple Manifold Filtration System
Product Dimensions

22 7/8" in 

(58.10 cm)

(13.65 cm)

5 3/8"

 in

To Remove Cartridge

3 in (7.62 cm) Minimum

HF9X Series 

Cartridge
24 1/16"

(63.66 cm)

HF6X Series 

Cartridge
18 1/16"
(45.9 cm)

HF4X Series 

Cartridge
15 1/16"

((38.3 cm)

 


background image

1

1

2

2

To Release Tubing 

To Attach Tubing 

Push tubing straight in as far
as it will go.

Tubing is secured in.

Push in collt to release tubing.

Pull tubing straight out.

Step 2

Step 3

Step 4

Step 1

This product is outfitted with a user friendly ‘Push In’ connector at the vent valve. Proper use of the connectors is 
shown in the figure below. It is most important that the tubing selected for use with these connectors be of high  
quality, exact size and roundness, and with no surface nicks or scratches.  If it is necessary to cut the tubing, use a 
plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a "Push-In" connec-
tor, the cause is usually a problem with tubing.
To Fix:   
 

 

1. Relieve pressure  

2. Release tubing    

3. Cut off at least 1/4” from end   

 

4. Reattach tubing   

5. Confirm connection is leak free

How to Use “Push-in” Connectors

 

This product is outfitted with inlet/outlet fittings. The fittings can be attached or removed from the system with-  

 

out tools. Retention clips are semi-circular in shape with three internal tabs, bottom, center and top. Tab interfaces   

 

with windows in the manifold head near each connection port clip is flexible and easily assembled following these  

 

instruction and illustrations.

 

 

1. Insert fitting into manifold.

 

 

2. With fitting inserted into manifold port, snap clip into place beginning at the bottom window

 

 

3. Push center tab into center window.

 

 

4. Finally push top tab into top window.

How to Use the Inlet/Outlet Fitting and Retention Clips 

5

Equipment Installation

CAUTION

T

o reduce the risk associated with property damage due to water leakage:

 

tDo not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic 

       plumbing.
t0OQMBTUJDmUUJOHTOFWFSVTFQJQFTFBMBOUPSQJQFEPQF6TF15'&UISFBEUBQFonly, pipe dope properties may 
       deteriorate plastic.

 

tTake care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtight-        

       ening occurs..

 

t%POPUinstall near water pipes which will be in path of a drilling tool when selecting the position to mount the system

 tMount filter in such a position as to prevent it from being struck by other items used in the area of installation.
 tEnsure that the location and fasteners will support the weight of the system when installed.
 

tEnsure all tubing and fittings are secure and free of leaks.

 


background image

  Both manifolds may be used with metal or non-metallic piping systems. 

  IMPORTANT NOTE: Any non-metallic fittings used in the installations must be of adequate rating for the  
                          line pressure.  
 

 

 

 

 

 

 

 

        1. Shut off incoming cold water supply. 

        2. Select the installation location.   

          WARNING: Allow a minimum of 3 in (7.6 cm) of space below the cartridges for change-outs. 

        3. Select fasteners (not included) and tools appropriate for the installation location (wall, support structure  

          mounted to wall studs, concrete, etc.)  

CAUTION

To reduce the risk associated with property damage due to water leakage:

   

tEnsure that the location and fasteners will support the weight of the system when installed when full of water.

 

 

 

 

 

      4. Mount the manifold/filter system to a wall or using the mounting holes provided on the back plate of the  
              metal bracket.   
      t*UJTSFDPNNFOEFEUPmSTUESBXBMFWFMMJOFPOUIFNPVOUJOHTVSGBDFBUUIFIFJHIUPGUIFGBTUFOFST
      t.BSLUIFMPDBUJPOPGUIFGBTUFOFSTVTJOHUIFCSBDLFUBTBUFNQMBUFPSCZNFBTVSJOHUIFEJTUBODF
          between 

the 

mounting 

holes. 

      t*OTUBMMUIFGBTUFOFSTBOEBMMPX

¼”-

3

/

8

” (6-10 mm) of each fastener to protrude from the surface.  

      t*OTUBMMUIFNBOJGPMEPOUPUIFGBTUFOFST 
      t5JHIUFOUIFGBTUFOFST 
        5. Install inlet (left rear) and outlet (right front) fittings to the manifold.  The inlet kit includes the fitting, a ball  
          valve and a ¾” nipple.  The outlet is a fitting only.  The instructions for the retention clips are on page 4. 

        6. Remove the sanitary caps from the cartridges, and apply a light coat of water or food-grade lubricant to  
          the  o-rings on each of the cartridges.   

        7. One at a time, align the tabs of the cartridge with the slots in the retaining plate and insert the cartridge  

          into the manifold. Be certain to place the correct cartridges into the correct locations. 

 

 

        8. Turn the cartridge to the right until a clicking sound is heard.  Repeat for all cartridges; the clicking sound  
          indicates the cartridge is properly engaged.

Equipment Start-up Procedure

 

 1. Turn on incoming water to system. 

 

 2. Pressurize system by slowly rotating the inlet water ball valve 

¼ turn to the left (counterclockwise) to the  

 

     “ON” position.  

 

 

 

 3. Check for leaks. 

 

 4. Use vent to remove trapped air. 

 

 5. Flush system in accordance with performance data sheet supplied with the cartridges.  

 

 6. System is now ready for use.

IMPORTANT NOTES

 

t'BJMVSFUPGPMMPXJOTUSVDUJPOTXJMMWPJEXBSSBOUZ

 t"MMPXBNJOJNVNPGwDNDMFBSTQBDFVOEFSmMUFSUPGBDJMJUBUFDBSUSJEHFDIBOHF
 t*OTUBMMXJUIUIFJOMFUBOEPVUMFUQPSUTBTMBCFMFE.BLFTVSFOPUUPSFWFSTFDPOOFDUJPOT
 t4PNFMPDBMDPEFTNBZSFRVJSFUIFVTFPGBMJDFOTFEQMVNCFSPSDFSUJmFEJOTUBMMFSXIFOEJTSVQUJOHBQPUBCMFXBUFSMJOF

6

 


background image

Cartridge Change-out  Procedure

 

 

Cartridges will need to be changed every 12 months or when low pressure in indicated on the manifold outlet 

 

pressure gauge, whichever occurs first. Depending on local water quality, you may need to change the cartridges  

 

prior to the  recommended change-out. The loss of flow to carbonators or improper fill at the ice maker are also  

 

indicators that the cartridges will need to be replaced 

 

      1. Rotate inlet water shut-off valve on manifold to the “OFF” position by rotating to the left (counterclockwise). 

 

      2. Install plastic tubing into vent valve on manifold and direct to drain.  

     3. 

Depressurize 

system. 

 

 

 

      4. Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left 

 

      5. Using both hands and holding cartridge from the bottom, rotate the cartridge a quarter turn to the left and  

       gently 

pull 

down. 

 

 

        CAUTION: A small amount of water will drain from manifold as cartridge is removed.  

 

      6. Remove sanitary cap from new cartridge. Install cartridge with a quarter turn to the right until cartridge  

 

        comes to a complete stop.  

 

        IMPORTANT NOTE: Cartridges are keyed to fit proper location only. 

 

      7. Slowly turn the valve on the manifold to the “ON” position and check for leaks. 

 

      8. Flush per the performance data sheet. System is now ready for use.

 

7

CAUTION

To reduce the risk associated with property damage due to water leakage:
 t3FBEBOEGPMMPXUse Instructions before installation and use of this system.
 t5IFEJTQPTBCMFmMUFSDBSUSJEHFMUST be replaced every 12 months or at the rated capacity or if a noticeable 
       reduction in flow rate occurs.

No water flow through system

Inlet valve closed

Filters clogged

Check shut-off valve position

Replace cartridges

Not enough water to 

downstream application

Low incoming water pressure

Filters clogged

Check source

Replace cartridges

Short filter life

Temporarily dirty water

Change cartridges or install an 

additional upstream Pre-Filter

Troubleshooting

 


background image

6

Item

Part no.

Description

Qty*

Micron Rating

1

6228405

Dual Manifold Assembly

1

Assembly, complete

2

60-2333700

Vent Valve (not shown)

1

Release trapped air

3

See catalog

Replacement Cartridges

1

Water filtration

4

85005-49

Pressure gauge

1

Monitor outlet water pressure

5

85-8528

Clip

1

Retain inlet/outlet fittings

6

63597320

o-ring

1

Seal inlet/outlet fittings

7

6220505

Inlet fitting kit

1

Inlet fitting with ball valve

8

6220506

Outlet fitting kit

2

Outlet fitting

9

60-235380

¾” x ¾” ball valve

1

Inlet water shut-off

10

85005-49

Pressure Gauge (optional)

1

Monitor inlet water pressure

11

Inquire

Retainer Kit

1

Secure Cartridges

Double Manifold Replacement Parts Listing

*Per part number, not per system or assembly.

6

1

10

3

3

4

10

7

9

Rear

Inlet

6

5

Shown with plug installed when 
gauge is not used.

8

 


background image

7

Item

Part no.

Description

Qty*

Micron Rating

1

6228405

Triple Manifold Assembly

1

Assembly, complete

2

60-2333700

Vent Valve

1

Release trapped air

3

See catalog

Replacement Cartridges

1

Water filtration

4

85005-49

Pressure gauge

1

Monitor outlet water pressure

5

85-8528

Clip

1

Retain inlet/outlet fittings

6

63597320

o-ring

1

Seal inlet/outlet fittings

7

6220505

Inlet fitting kit –left rear

1

Inlet fitting with ball valve

9

6220507

Outlet fitting kit – right front

1

outlet fitting

10

60-235380

Pressure Gauge (optional)

1

Inlet water shut-off

11

85005-49

Pressure gauge (Optional)

1

Monitor inlet water pressure

 

12

Inquire

Retainer Kit

1

Secure cartridges

Triple Manifold Replacement Parts Listing

*Per part number, not per system or assembly.

1

6

3

3

3

4

2

8

5

7

10

Rear

Outlet

Inlet

6

11

Shown with plug installed when 
gauge is not used.

9

 


background image

3M Purification Inc. warrants Dual/Triple manifold water filtration systems only to be free from defects in material and workmanship 
for one (1) year from the date of purchase. The disposable filter cartridge is warranted from defects in material and workmanship for 
a period of one (1) year from the date of purchase. This warranty does not cover failures resulting from abuse, misuse, alterations 
or damage not caused by 3M Purification Inc. or failure to follow installation and use instructions. No warranty is given as to the 
service life of any filter cartridge or membrane as it will vary with local water conditions and consumption.  3M PURIFICATION INC. 
MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED 
WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY 
OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE.  
If the Product fails to satisfy this 
Limited Warranty during the warranty period, 3M Purification Inc., at it’s option, will replace the Product or refund your Product 
purchase price. This warranty does not cover labor.  The remedy stated in this paragraph is Customer’s sole remedy and 3M 
Purification Inc.’s exclusive obligation.

This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or country to country. 
For any warranty questions, please call 866.990.9785 or mail your request to: Warranty Claims, 3M Purification Inc., 400 Research 
Parkway, Meriden, CT 06450. Proof of purchase (original sales receipt) must accompany the warranty claim, along with a complete 
description of the Product, model number and alleged defect.

Limitation of Liability: 3M Purification Inc. will not be liable for any loss or damage arising from this 3M Purification Inc. product, 
whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, 
negligence or strict liability. Some states and countries do not allow the exclusion or limitation of incidental or consequential damages, 
so the above limitation or exclusion may not apply to you.

Limited Warranty

10

 


background image

11

 


background image

3M is a trademark of 3M Company.
© 2013 3M Company. All rights reserved.
34-8712-8017-7

Please Recycle. Printed in U.S.A.

3M Purification Inc.

400 Research Parkway

Meriden, CT 06450, USA

Toll Free: 866.990.9785

Worldwide: 203.237.5541

Fax: 203.238.8701

www.3Mfoodservice.com

www.3Mpurification.com

12