3M Attest Auto-reader 490H Operator's Manual

Made by: 3M
Type: Operator's Manual
Category: Laboratory Equipment
Pages: 16
Size: 1.57 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

Description:

DIELINE

Base File Name:

Software:
SGS Contact:
Email:
Printer:
Printer Location:
Supplier:

3M™ Attest™

Auto-Reader 490H

Requester: Linda Thompson

Reference:

Die # / Doc. Size: 8.5" x 11"

Item Spec#: 34-8720-4946-4

Supersedes#:

Cat/Product#: 490H

Structure#:

Insert

PA: 490H_34872049464.indb
GA:

InDesign CS14

PROCESS

BLACK

PROCESS

CYAN

3M

RED

PROCESS

MAGENTA

PROCESS

YELLOW

4554361

2

03.21.17 New – updates per word document, set-up for Phase 2 Multi language.

Jer

03.22.17 Update with new image.

Jer

3M

 Attest

 Auto-reader 490H

1

Operator’s Manual

2

Manuel de l’utilisateur

3

Benutzerhandbuch

4

Manuale dell’operatore

5

Manual del usuario

5

Manual del operador

6

Bedieningshandleiding

7

Användarhandbok

8

Brugsvejledning

9

Brukerhåndbok

0

Käyttöopas

-

Manual do Utilizador

-

Manual do Operador

=

Εγχειρίδιο Χειριστή

H

Instrukcja obsługi

F

Příručka pro obsluhu

S

Priročnik za uporabo

M

Инструкция по эксплуатации

]

Upute za korištenje

d

Operatör Kılavuzu

I

操作指南

j

คู่มือปฏิบัติงาน

T

작업자 매뉴얼

 


background image

 


background image

1

1

3M

™ Attest Autoreader 490H

1

Read and understand all safety information before using this product.

TABLE OF CONTENTS

Preface .......................................................................................................................................................................2
Intended Use ..............................................................................................................................................................2
Indications for Use.....................................................................................................................................................2
Product Description...................................................................................................................................................2
Warranty .....................................................................................................................................................................2
Safety and Precautions .............................................................................................................................................2
Health and Safety Information..................................................................................................................................3
Explanation of Product and Packaging Label Symbols ..........................................................................................3
Specifications ............................................................................................................................................................4
Instructions for Use ...................................................................................................................................................4
Features ......................................................................................................................................................................7
Care and Cleaning .....................................................................................................................................................8
Troubleshooting Guide...............................................................................................................................................8
Optional 3M

™ Attest Autoreader 490H WebApp ...............................................................................................9

Troubleshooting the 3M

™ Attest Autoreader 490H WebApp ..........................................................................12

Repair and Replacement.........................................................................................................................................12

 


background image

2

3

1

PREFACE

Manual Revision History

Date

Revision

Reason for Revision

November, 2013

A

Initial Issue

September, 2014

B

To add network switch requirements to the

WebApp section.

April, 2015

C

Various specification edits/updates.

490H Web App Configuration Page: Added

rows for secondary DNS and MAC address.

BI Activation instructions: added option to

activate 1295 BI using Attest™ BI Activator.

March, 2017

D

Revised to reflect reduced time for final

fluorescent result. Applicable to 3M™

Attest™ Auto-reader 490H software version

4.0.0 or greater.

Content Disclaimers

Pictorial Disclaimer
Sample printouts, graphics, displays and screens are for information and illustration

purposes only, and shall not be used for clinical or maintenance evaluations. Data shown

in sample printouts and screens do not reflect actual test results.

Hardware Disclaimer
The 3M™ Attest™ Auto

‑reader 490H hardware specifications are subject to change.

The system images, hardware components and hardware specifications included in

the manual may not match the system installed. Any changes or modifications to the

authorized system installation have been verified as compatible with the functionality

outlined in this document.

INTENDED USE

The 3M™ Attest™ Rapid Readout Biological Indicator System for Vaporized Hydrogen

Peroxide Sterilization provides rapid and reliable routine monitoring of vaporized hydrogen

peroxide sterilization processes in health care facilities. The system is comprised of an

incubator/reader with embedded software, the 3M™ Attest™ Auto

‑reader 490H, and a

biological indicator, the 3M™ Attest™ Rapid Readout Biological Indicator 1295.

INDICATIONS FOR USE

The 3M™ Attest™ Auto

‑reader 490H is designed to incubate and automatically read the

3M™ Attest™ Rapid Readout Biological Indicator 1295 at 60°C for a final fluorescent

result at 24 minutes.

PRODUCT DESCRIPTION

The 3M™ Attest™ Rapid Readout Biological Indicator System for Vaporized Hydrogen

Peroxide Sterilization provides rapid, reliable routine monitoring of hydrogen peroxide

vapor sterilization processes performed in health care facilities. The system is comprised

of a biological indicator and an incubator/reader (3M™ Attest™ Auto

‑reader 490H) with

embedded software. The 3M™ Attest™ Auto

‑reader 490H is designed to incubate and

automatically read 3M™ Attest™ Rapid Readout Biological Indicators 1295 at 60°C for a

final fluorescent result at 24 minutes.
The 3M™ Attest™ Auto

‑reader 490H is also designed to allow for further incubation

of positive control 3M™ Attest™ Rapid Readout Biological Indicators 1295 for a final

positive visual pH color change result at 24 hours. It is recommended that processed BIs

be transferred to a humidified incubator for further incubation. A final negative visual pH

color change result is assessed after 7 days. This further incubation is optional and not

intended for routine use.
A positive fluorescence reading or a positive visual pH color change result indicate a

sterilization process failure. However, due to the high sensitivity of the fluorescent result,

there is no advantage to continuing to incubate processed 3M™ Attest™ Rapid Readout

Biological Indicators 1295 once the fluorescent result has been documented.
Other biological indicators (BIs) are not compatible with this device and cannot be used.

WARRANTY

The 3M™ Attest™ Auto

‑reader 490H has a one year limited product warranty.The

US warranty, remedy and limitations are described in the Price Quote form and in the

Direct Price Pages. For countries outside of the US, any warranty is established by the

subsidiary with responsibility for service of the 3M™ Attest™ Auto

‑reader 490H.

Serial Number

For easy identification, each 3M™ Attest™ Auto

‑reader 490H has a unique serial number

printed on a label found on the back of the unit and displayed on the left side of the upper

row of text on the LCD display when the user depresses the

button. Please record

your serial number in this manual for future reference: ___________________.

SAFETY AND PRECAUTIONS

The 3M™ Attest™ Auto

‑reader 490H and its related devices and accessories are

designed to provide safe and reliable service when used according to the instructions

provided. Please read, understand, and follow all safety information contained in

the instructions for use included with the 3M™ Attest™ Auto

‑reader 490H and the

3M™ Attest™ Rapid Readout Biological Indicator 1295 devices prior to use. Use this

equipment only for the purpose described in this Operator

’s Manual. Retain these

instructions for future reference.
The unit is designed to be used only with the Power Supply module and Ethernet cable

supplied by 3M. If this product is used in a manner not specified, the protection provided

by the product may be impaired.

Explanation of Single Word Consequences

Warning: Indicates a hazardous situation, which, if not avoided, could result in

death or serious injury.

Caution: Indicates a hazardous situation, which, if not avoided, could result in

minor or moderate injury.

Warnings and Safety Precautions

The following warnings and precautions should be followed to avoid unsafe actions that

could result in personal injury or damage to the instrument.

WARNING: To reduce the risk associated with hazardous voltage

Use indoors only.

Do not use the equipment if it is not working properly or if it has suffered any damage.

Use only the power supply specified for this product and certified for the country

of use.

CAUTION: To reduce the risk of injury or instrument damage

Do not spill liquid onto or into the instrument. Do not immerse the unit in liquid.

Always unplug the 3M™ Attest™ Auto

‑reader 490H and allow to cool before cleaning.

Clean external surfaces using only the instructions provided by the manufacturer.

Do not open the instrument housing

– there are no user serviceable parts.The

instrument must be returned to the manufacturer for repair.

Wear safety glasses and gloves when activating the 3M™ Attest™ Rapid

Readout Biological Indicator 1295.

 


background image

2

3

1

WARNING: To reduce the risk associated with incorrect results

Instrument is to be used by operators familiar with the device, device functionality, and

Operator

’s Manual.

Do not place the instrument in environment exposed to sunlight or strong

incandescent light.

Do not place instrument close to any device that emits a strong electro

‑magnetic field.

Do not use on a vibrating surface.

Activate and incubate 3M™ Attest™ Rapid Readout Biological Indicators 1295 within

1 hour of the completion of the sterilization cycle.

Do not incubate a 3M™ Attest™ Rapid Readout Biological Indicator 1295 if, after

processing and before BI activation, it is observed to have a broken media ampoule.

Retest the sterilizer with a new biological indicator.

Incubate the 3M™ Attest™ Rapid Readout Biological Indicator 1295 only in the

3M™ Attest™ Auto

‑reader 490H i.e., match the pink cap color of the 1295 BI with

the pink color

‑coded configuration sticker surrounding the 3M™ Attest™ Auto‑reader

490H incubation wells.

Do not remove the 3M™ Attest™ Rapid Readout Biological Indicator from the

incubation well until the (+) or (

‑) symbol on the LCD display indicates the test

is complete.

Caution: To reduce the risk associated with incorrect results

To avoid the possibility of the 3M™ Attest™ Rapid Readout Biological Indicator

1295 vial absorbing fluorescent residue from a chemical indicator or tape, place the

3M™ Attest™ Rapid Readout Biological Indicator vial so it does not come in direct

contact with chemical indicators or tape.

HEALTH AND SAFETY INFORMATION

Device Safety Compliance

The 3M™ Attest™ Auto

‑reader 490H complies with the following standards as

demonstrated by the CB Scheme Certificate and test report issued by Underwriters

Laboratories (UL):
• IEC 61010

‑1 (2010) 3rd Edition. Safety requirements for electrical equipment for

measurement, control, and laboratory use

‑ Part 1: General requirements

• IEC 61010

‑2‑010: 2014 3rd Edition. Safety requirements for electrical equipment for

measurement, control, and laboratory use

‑ Part 2‑010: Particular requirements for

laboratory equipment for the heating of materials

The 3M™ Attest™ Auto

‑reader 490H is listed as Laboratory equipment and carries the

UL mark with adjacent indicators

“C” and “US” based on compliance to the standards UL

61010

‑1, CAN/CSA C22.2 No. 61010-1 and CAN/CSA C22.2 No. 61010-2-010.

The 3M™ Attest™ Auto

‑reader 490H complies with the CE mark related to the Low

Voltage Directive (LVD) 2006/95/EC as confirmed in the Declaration of Conformity.
The 3M™ Attest™ Auto

‑reader 490H complies with the RoHS Directive, Directive

2011/65/EU of the European Parliament and of the Council of 8 June 2011 on

the restriction of the use of certain hazardous substances in electrical and

electronic equipment.
The 3M™ Attest™ Auto

‑reader 490H complies with the WEEE Directive, Directive

2012/19/EU of the European Parliament and of the Council of 04 July 2012 on waste

electrical and electronic equipment (WEEE).

EMC Compliance

The 3M™ Attest™ Auto

‑reader 490H complies with the following EMC standards as

confirmed in the Certificate of Compliance generated by 3M:
• IEC 61326

‑1:2012/EN 61326:2013 Electrical equipment for measurement, control and

laboratory use

‑ EMC requirements ‑ Part 1: General requirements

• EMC requirements of the CE mark EMC Directive 2004/108/EC.

The 3M™ Attest™ Auto

‑reader 490H complies with the Australian and New Zealand

electrical safety and electromagnetic compatibility requirements as confirmed in the

Supplier

’s Declaration of Conformity that is linked to the Australian/New Zealand RCM

(Regulatory Compliance Mark).
Note: This equipment has been tested and found to comply with the limits for a Class A

digital device pursuant to Part 15, Subpart B, of the FCC Rules. These limits are designed

to provide a reasonable protection against harmful interference when the equipment is

operated in a commercial environment. This equipment generates, and can radiate radio

frequency energy and, if not installed and used in accordance with the instruction manual,

may cause harmful interference to radio communications. Operation of this equipment

in a residential area is likely to cause harmful interference in which case the user will be

required to correct the interference at their own expense.
This Class A digital device meets all requirements of the Canadian Interference

‑Causing

Equipment Regulations.

EXPLANATION OF PRODUCT AND PACKAGING

LABEL SYMBOLS

Attention

‑ Refer to the instructions for use

Waste Electrical and Electronic Equipment (WEEE) and EU Battery Directive.

This symbol indicates that both the device and the lithium ion battery

contained therein need to be disposed of properly.

UL Listed to US and Canadian Safety Standards

Mark of Conformity to European Directives

Direct current

Compliant to all applicable ACMA regulatory arrangements (RCM)

Manufacturer

Catalog number

Authorized representative for the European Community

Serial number

Li

REF

 


background image

4

5

1

SPECIFICATIONS

Power Supply Specifications

Power supply

Operating Condition

Units

Voltage Range

100

‑240

Volts AC

Frequency

50/60

Hertz

Current

0.6

Amps

Environmental Operating Conditions

Environmental Condition

Operating Condition

Units

Altitude

3000 (max)

Meters

Operating Temperature

16

– 40

ºC

Storage Temperature

‑10 to 50

ºC

Operating Relative Humidity

20

‑80 (non‑condensing) %

Voltage Range

12

Volts DC

Frequency

DC

Current

1.2

Amps

Installation/Over Voltage

Category II

Pollution Degree

2

INSTRUCTIONS FOR USE

 INITIAL SETUP

Choose Location

Place 3M™ Attest™ Auto

‑reader 490H on a firm and level surface, away from sunlight

and incandescent light. To save counter space, units may be stacked two high.

 WARNING:

• Do not place the instrument in environment exposed to sunlight or strong

incandescent light.

• Do not place instrument close to any device that emits a strong

electro

‑magnetic field.

• Do not use on a vibrating surface.

Select & Install Correct Power Plug

The 3M™ Attest™ Auto

‑reader 490H power supply comes with multiple blade

configurations. Install the blade configuration appropriate for your country into the power

supply and plug into appropriate AC grounded outlet.

WARNING: Use only the power supply specified for this product and certified for

the country of use.

Wait 30 Minutes Before Using

Once plugged in, allow a 30 minute warm

‑up period before placing 3M™ Attest™ Rapid Readout Biological Indicators 1295 into the incubation wells.The C1 caution code will

disappear when proper incubation temperature is reached.

Special Considerations

It is recommended that the unit be left on to eliminate warm-up periods. The unit may be turned off when it is anticipated that it will not be used for an extended period.

 


background image

4

5

1

INSTRUCTIONS FOR USE

– WELLS, BUTTONS, & DISPLAY INTERPRETATION

Please familiarize yourself with the face of the 3M™ Attest™ Auto

‑reader 490H:

Wells

1. Incubation/Reader Wells

– The 3M™ Attest™ Auto‑reader 490H has ten

incubation wells.

Buttons

2. Information / Up Arrow Button

3. Temperature / Down Arrow Button

4. Buzzer Alarm OFF / Enter Button

Information Display

5. LCD display

– Display is backlit

6. LCD display

– Example of Error Message for well #6

7. LCD display

– Example of Remaining Incubation Time, in minutes, for well #10

8. LCD display

– Example of Negative ( ‑ ) BI result for well #9

9. LCD display

– Example of Positive ( + ) BI result for well #8

10. LCD display

– Alarm Enabled Indicator

Color

Coded Configuration Indicator

11. Incubation well configuration sticker is color

‑coded pink

INSTRUCTIONS FOR USE

3M

™ ATTEST™ AUTOREADER 490H CONFIGURATION

Note: Ideally, the 3M™ Attest™ Auto

‑reader 490H should be empty (i.e., have no

incubating BIs) when it is reconfigured.

Press the

and

buttons on the front of the 3M™ Attest™ Auto

‑reader 490H

simultaneously for 3 seconds to enter configuration mode. Once in configuration mode,

use the Up

 and Down

 buttons to set the 3M™ Attest™ Auto

‑reader 490H

clock and audible alarm as desired. The button

acts as an

“Enter” key and moves the

flashing cursor to the next changeable setting.

Setting the 3M

™ Attest Autoreader 490H Clock

The 3M™ Attest™ Auto

‑reader 490H date and time are displayed in this format:

YYYY

‑MM‑DD HH:MM, with the time displayed using a 24 hour clock.To change the

year, if necessary, push the up or down buttons to set desired year, then press

to

advance to the month, adjust as necessary and press

to advance to the day. Use the

button to move to the time and set the hours and minutes.

Setting the Audible Alarm Function

Move across the top row of text by pushing the

button. The flashing

“B” in Buzzer

indicates this is a changeable setting. It is recommended this be set at

“Buzzer Enabled”

to audibly alert the operator to a positive BI but it may be set to

“Buzzer Disabled” by

using either the up or down button.

Note: If Buzzer Disabled is selected, and the change is

accepted, the speaker icon (  ) will disappear from the LCD panel and the alarm will be

disabled for all positive 3M™ Attest™ Rapid Readout Biological Indicators, error codes,

and caution code alarm warnings.
Note: The 3M™ Attest™ Auto

‑reader 490H display backlight flashes whenever an

audible alarm sounds. Disabling the audible alarm does NOT disable the LCD display

backlight flashing.

Press

to select the desired option and advance to the Accept screen.

Accept Screen

Use the up or down buttons to toggle between Yes and No, press

 to accept changes

(Yes selected) or retain current settings (No selected) and exit the configuration mode. The

LCD panel will return to the standard display.

 


background image

6

7

1

INSTRUCTIONS FOR USE

 READOUT PROCEDURE

Instructions for Biological Indicator (BI) Activation and Incubation

CAUTION: To avoid the possibility of the 3M™ Attest™ Rapid Readout

Biological Indicator 1295 vial absorbing fluorescent residue from a chemical indicator

or tape, place the 3M™ Attest™ Rapid Readout Biological Indicator vial so it does not

come in direct contact with chemical indicators or tape.

WARNING: To reduce the risk associated with incorrect results

Do not incubate a 3M™ Attest™ Rapid Readout Biological Indicator 1295 if, after

processing and before BI activation, it is observed to have a broken media ampoule.

Retest the sterilizer with a new biological indicator.

Activate and incubate 3M™ Attest™ Rapid Readout Biological Indicators 1295 within

1 hour of the completion of the sterilization cycle.

Incubate the 3M™ Attest™ Rapid Readout Biological Indicator only in the

3M™ Attest™ Auto

‑reader 490H i.e., match the pink cap color of the 1295 BI with

the pink color

‑coded configuration sticker surrounding the 3M™ Attest™ Auto‑reader

490H incubation wells.

CAUTION: Wear safety glasses and gloves when activating the 3M™ Attest™

Rapid Readout Biological Indicator 1295.

Follow this procedure for every 3M™ Attest™ Rapid Readout Biological Indicator (BI) to

be read.

or

While wearing safety glasses and gloves,

PLACE BI in color

‑coded 3M™ Attest™

Auto

‑reader 490H well. Note that BI

vial is keyed for specific orientation

in well (flat back of BI faces back of

3M™ Attest™ Auto

‑reader 490H).

While wearing safety glasses and gloves,

PLACE BI in Attest™ Biological Indicator

Activator.

or

CLOSE BI cap and CRUSH media

ampoule by firmly pushing vial straight

down in incubation well.

CLOSE and SQUEEZE Attest™ Biological

Indicator Activator to close BI cap and crush

media ampoule.

Immediately remove BI, visually

VERIFY the glass ampoule

(containing growth media) has been crushed, and

FLICK BI to

ensure purple growth media flows to the growth chamber at the

bottom of the vial.

PLACE the activated BI into a 3M™ Attest™ Auto-reader 490H

well and observe 3M™ Attest™ Auto-reader 490H LCD display

to confirm correct placement of the BI. If the BI is correctly

seated, the 3M™ Attest™ Auto-reader 490H LCD display will

show ***, **, * and then remaining minutes of incubation directly

below the incubating BI.
RECORD BI result.

WARNING: Do not remove the 3M™ Attest™ Rapid Readout Biological

Indicator 1295 from the incubation well until the (+) or (

‑) symbol on the LCD display

indicates the test is complete.

INSTRUCTIONS FOR USE

 ADDITIONAL INFORMATION

BI Placement

Remaining incubation time, in minutes, will be displayed on the LCD display to indicate

the 3M™ Attest™ Rapid Readout Biological Indicator is incubating in the reader well and

should not be touched. The time remaining display indicates the result is not available and

incubation is in progress.
Do not remove 3M™ Attest™ Rapid Readout Biological Indicator until the (+) or (-)

symbol on the LCD panel indicates the test is complete. Once the result is determined,

it is continuously displayed on the LCD panel until 10 seconds after the BI has been

removed from the incubation well.
Note: After the first minute of incubation, if 3M™ Attest™ Rapid Readout Biological

Indicator is inadvertently removed before the incubation period is complete, an alarm will

sound and a C2 Caution code will be displayed on the LCD panel under that well.

You

must return the 3M™ Attest™ Rapid Readout Biological Indicator to the reader well

within 10 seconds or the results will be lost.

WARNING: Do not remove or change placement of 3M™ Attest™ Rapid

Readout Biological Indicator once it is placed into a well. Doing so may result in loss of

results and the 3M™ Attest™ Rapid Readout Biological Indicator test may be invalid.

INSTRUCTIONS FOR USE

 POSITIVE CONTROL

Positive Control

Activate and incubate at least one non

‑processed 3M™ Attest™ Rapid Readout Biological

Indicator 1295 to use as the positive control each day that a processed 3M™ Attest™

Rapid Readout Biological Indicator 1295 is incubated and read by the unit. Write a

“C” (for

“control”) and the date on the label.The positive control can be placed in any incubation

well. The positive control should be the same part number and have the same lot number

as the processed 3M™ Attest™ Rapid Readout Biological Indicator in the unit.
The positive control biological indicator helps confirm:
• correct incubation temperatures are met (heater block reading of 60°C +/

‑2°C);

• viability of spores has not been altered due to improper storage temperature, humidity,

or proximity to chemicals;

• capability of media to promote rapid growth; and

• proper functioning of 3M™ Attest™ Auto

‑reader 490H components.

INSTRUCTIONS FOR USE

 INTERPRETATION OF RESULTS

Fluorescent Results

After placing a 3M™ Attest™ Rapid Readout Biological Indicator into an incubation

well, the 3M™ Attest™ Auto

‑reader 490H LCD display will show ***, **, * and then

the remaining minutes of incubation directly below the incubating BI to indicate that

incubation/reading is in progress. The 3M™ Attest™ Rapid Readout Biological Indicator

should not be removed or touched when the display indicates remaining incubation time.
A (+) will display on the LCD panel directly under the BI and an alarm will sound (if the

sound feature is enabled) as soon as a positive 3M™ Attest™ Rapid Readout Biological

Indicator result is detected.
At the end of the specified incubation time, if a negative 3M™ Attest™ Rapid Readout

Biological Indicator result is detected, a (

‑) will display on the LCD panel directly under

the incubating BI. The final negative fluorescent result (

‑) for a processed 3M™ Attest™

Rapid Readout Biological Indicator 1295 indicates an acceptable sterilization process.
After either the (+) or (

–) symbol is displayed, and the result is recorded, the

3M™ Attest™ Rapid Readout Biological Indicator can be removed from the well. Do not

re-incubate BIs as the result will not be valid.
The positive (unprocessed) control 3M™ Attest™ Rapid Readout Biological Indicator

1295 must provide a positive fluorescent result (+). Processed 3M™ Attest™ Rapid

Readout Biological Indicator results are not valid until the positive control reads fluorescent

positive (+).

 


background image

6

7

1

With a processed 3M™ Attest™ Rapid Readout Biological Indicator, a positive (+) result

indicates a sterilization process failure. Act on any positive test results immediately.

Determine the cause of the positive 3M™ Attest™ Rapid Readout Biological Indicator and

retest the sterilizer following current facility policies and procedures.

Optional Visual pH Color Change Result

3M™ Attest™ Rapid Readout Biological Indicators 1295 for Vaporized Hydrogen Peroxide

Sterilization may be further incubated for a visual pH color change.  Due to the high

sensitivity of the fluorescent result, there is no advantage to continuing to incubate 3M™

Attest™ Rapid Readout Biological Indicators 1295 after the fluorescent result has been

determined and documented. This optional further incubation is not intended for routine

use but may be used for special studies.
In the case of a positive control BI, a yellow color change of the growth media will appear

within 24 hours. Any observation of a yellow color within the vial indicates a positive

result. The pH color change result can be recorded and the BI discarded as soon as the

yellow color is observed and the result recorded.
For processed 3M™ Attest™ Rapid Readout Biological Indicators 1295, the use of a

humidified incubator is recommended to avoid media dry out. If a visual pH color change

result is desired, transfer the processed 1295 BI to a humidified incubator after the

fluorescent result has been determined in the 3M™ Attest™ Auto

‑reader 490H.A media

color change from purple to yellow indicates a sterilization process failure. A negative pH

color change result, i.e., media remains purple, can be assessed at 7 days.

INSTRUCTIONS FOR USE

 DISPOSAL

Instrument contains a lithium battery. Dispose of instrument in accordance with federal,

state, and local requirements.

FEATURES OF THE 3M

™ ATTEST AUTOREADER 490H

Audible Alarm

An audible alarm will sound, the LCD display backlight will flash, and a (+) symbol will

be displayed on the LCD panel directly under the incubating BI when a positive result is

detected. An alarm will also sound if a 3M™ Attest™ Rapid Readout Biological Indicator

is removed from the 3M™ Attest™ Auto

‑reader 490H well before a final result has been

detected. Data will be lost if the 3M™ Attest™ Rapid Readout Biological Indicator is not

replaced in the incubation well within 10 seconds.

Alarm On/Off

The audible alarm for positive results can be turned off for a particular 3M™ Attest™

Rapid Readout Biological Indicator. This is accomplished by pressing the

“Buzzer Alarm

OFF

” button after the alarm has sounded.This will turn off the alarm for that BI only.Any

positive 3M™ Attest™ Rapid Readout Biological Indicator results subsequently detected

in other wells will result in the alarm sounding. Removing the 3M™ Attest™ Rapid

Readout Biological Indicator will reactivate the alarm for that well. Pressing the

“Buzzer

Alarm OFF

” button will not silence the alarm for error or caution code alarm warnings.To

disable the alarm, see configuration section.

Stackable

To save counter space, 3M™ Attest™ Auto

‑readers 490Hs may be stacked two high.

Information Button

When the Information button is pressed once the 3M™ Attest™ Auto

‑reader 490H

displays two lines of text in the LCD display.
The top row indicates (left to right):
• 3M™ Attest™ Auto

‑reader 490H serial number

• 3M™ Attest™ Auto

‑reader 490H embedded software version (V X.Y.Z)

• Current date and time.
The bottom row indicates (left to right):
• The BI type configuration for wells 1

‑5 (i.e., 1295)

• The BI type configuration for wells 6

‑10 (i.e., 1295)

Press the information button twice and the 3M™ Attest™ Auto

‑reader 490H LCD display

will present two additional lines of text.
The top row indicates:
• IP address (if unit is connected to an Ethernet jack).
The bottom row indicates (left to right):
• Date (YYYY

‑MM‑DD) and time that power was supplied to the 3M™ Attest™

Auto

‑reader 490H.

Press the information button three times and the 3M™ Attest™ Auto

‑reader 490H LCD

display will present the unique Media Access Control (MAC) Address for the device.

Temperature Monitoring

The 3M™ Attest™ Auto

‑reader 490H contains an internal temperature self‑diagnostic

program. Should the temperature fall outside the specified range (60ºC +/

‑2ºC) an error

code will be displayed. The heater block temperature may be checked by depressing the

Temperature button once.

Easy Configuration

The 3M™ Attest™ Auto

‑reader 490H may be configured using either the buttons located

on the front of the unit or using the optional 3M™ Attest™ Auto

‑reader 490H Web App.

Optional 3M

™ Attest Autoreader 490H Web App

If desired, the 3M™ Attest™ Auto

‑reader 490H may be connected to a PC via an Ethernet

connection for additional capabilities:
• Remotely view current status of BIs in the 3M™ Attest™ Auto-reader 490H via

networked PC or mobile hand held devices. For full functionality, the use of an HTML5

compliant browser with JavaScript enabled is required.

• Remotely view and configure 3M™ Attest™ Auto

‑reader 490H settings.

• View the last 100 BI records.

• Print out documentation using a local or networked printer and/or save documentation

as an electronic file.*

Note: To access the 3M™ Attest™ Auto

‑reader 490H Web App within a secure network,

the PC or mobile device must have access to the secure network; options include

connecting via a network Ethernet cable, signing in to the facility

’s wireless network, or

connecting via a virtual private network (VPN).
* Refer to your facility

’s record keeping policy and procedure.

 


background image

8

9

1

CARE AND CLEANING

Clean the exterior surface of the 3M™ Attest™ Auto

‑reader 490H by wiping it with a

damp cloth moistened with a mild detergent. Do not attempt to clean interior components.

If additional cleaning of the wells is required, call for repair or replacement.
Note: The 3M™ Attest™ Auto

‑reader 490H does not contain any user serviceable parts

or require any routine maintenance or calibration. Any malfunctions will be indicated by an

error code. Refer to the Troubleshooting Guide section for error code explanations.

CAUTION: Always unplug the 3M™ Attest™ Auto

‑reader 490H and allow to

cool before cleaning.

Do not spill liquid onto or into the instrument. Do not immerse the unit in liquid.

Clean external surfaces using only the instructions provided by the manufacturer.

Do not open the instrument housing

– there are no user serviceable parts.The

instrument must be returned to the manufacturer for repair.

TROUBLESHOOTING GUIDE

In the event of an error code, unplug the 3M™ Attest™ Auto

‑reader 490H and plug it back in to initiate the self‑diagnostic test. If error code re‑occurs, call for repair or replacement.

The LCD display will indicate detected malfunctions by displaying a caution or error code under affected BI wells. The audible alarm, if active, sounds and the LCD display backlight

flashes to alert the user to all caution (except C1) and error codes. The alarm and backlight can be silenced and extinguished, respectively, by pressing the Buzzer Alarm OFF button

.

Note that disabling the audible alarm does not disable the flashing LCD display backlight. Refer to the following:

Code/ Issue

Problem

Solution

C1

Unit Warm

‑up Caution

Incubation block not at temperature.

Allow a 30 minute warm

‑up after 3M™ Attest™ Auto‑reader 490H is

plugged in. (Note: 3M™ Attest™ Rapid Readout BI readings are disabled until

incubator block reaches 60ºC +/

‑ 2ºC).

C2

BI Removed from Well Caution
3M™ Attest™ Rapid Readout BI has been removed before incubation is complete.

Replace 3M™ Attest™ Rapid Readout BI in proper well within 10 seconds to

prevent loss of collected data.

C4

Ambient Light Caution

Move 3M™ Attest™ Auto

‑reader 490H to reduced ambient light conditions.

E1

Temperature Control Error
This error will occur if system is no longer able to control the temperature of the

incubator block (60ºC +/

‑ 2ºC ).

Unplug the unit and plug it back in to clear error.
If error doesn

’t clear, call for repair or replacement.

E3

Memory Error
3M™ Attest™ Auto

‑reader 490H unable to save/read data from memory.

Unplug the unit and plug it back in to clear error.
If error doesn

’t clear, call for repair or replacement.

E7

Communications Error
This error will occur if internal communications have failed.

Unplug the unit and plug it back in to clear error. If error doesn

’t clear, call for

repair or replacement.

E8

LED Error
This error occurs for a specific well if the system detects that a UV LED or Optics

Detection circuit is not working.

Unplug the unit and plug it back in to clear error.
If error doesn

’t clear, call for repair or replacement. Do not use affected

incubation well.

E11

BI Inserted Incorrectly Error
Incubation time remaining will not display and fluorescent readings are not taken.

Remove BI and inspect to verify cap is fully closed, glass ampoule is crushed,

and growth media is in growth chamber. If necessary, repeat BI activation

steps: place & push BI down FIRMLY into incubation well; remove BI and flick

it; inspect BI; and return BI to incubation well, ensuring it is seated properly.

E12

Power Failure Error
Power to Auto

‑reader was off for too long to provide valid result for affected BI(s).

Ensure power supply connection to Auto

‑reader is secure. Retest sterilizer

with a new BI.

E14

Ambient Light Error (occupied well)
Fluorescent result will not display.

Rely on optional visual pH color change result for BI in affected well. Move

3M™ Attest™ Auto

‑reader 490H to reduced ambient light conditions to avoid

future occurrences. To clear E14 error code, after visual pH color change result

has been documented and BI has been removed, unplug the 3M™ Attest™

Auto

‑reader 490H and plug it back in.

Other

Unwanted alarm sounds when positive BI detected.

Disable alarm; refer to

3M™ Attest™ Auto-reader 490H Configuration

section for instructions.

Other

Alarm Sounds
3M™ Attest™ Rapid Readout Biological Indicator has been removed from

incubation/reader well prematurely.

Replace 3M™ Attest™ Rapid Readout Biological Indicator in incubation/

reader well within 10 seconds to prevent loss of data collected.

Other

LCD display does not display properly.

Unplug the unit and plug it back in. If problem persists call for repair

or replacement.

Other

Negative Control Vial
BI not properly activated/ media did not contact spore carrier.

Ensure BI cap is closed and glass ampoule is crushed. Flick BI until media

flows to spore chamber at bottom of BI.

 


background image

8

9

1

Code/ Issue

Problem

Solution

Other

Negative Control Vial
Control vial was sterilized.

Check process indicator on BI cap. Use a non

‑sterilized vial as a control.

Other

Unexplained Positive BI
Adhesive residue on vial.

Do not place tape or labels on vial.

Other

Unexplained Positive BI
Test vial is absorbing fluorescent residue from a chemical indicator or tape.

Place the vial so it does not come in direct contact with chemical indicators

or tape.

Other

3M™ Attest™ Auto

‑reader 490H will not enter Configuration mode.

Pushbutton Configuration may be disabled on 3M™ Attest™ Auto

‑reader 490H

Web App.

On 3M™ Attest™ Auto

‑reader 490H Web App Configuration Page, go to

Pushbutton Configuration and select the

Enable radio button. Save changes to

begin using new setting.

Other

3M™ Attest™ Auto

‑reader 490H LCD display flashes and asterisks (***) and/or

E11 and/or C4 codes appear on display below unoccupied incubation wells.

Move 3M™ Attest™ Auto

‑reader 490H away from sunlight or sources of

incandescent light.

OPTIONAL 3M

™ ATTEST AUTOREADER 490H WEB APP

Web Browser Requirements

The web interface is designed to be viewed in Internet Explorer 8.0 or higher. Earlier

versions of Internet Explorer or other browsers may result in some web pages being

displayed in a less-than-optimal manner. For best results, switching to Internet Explorer

8.0 or higher is recommended. For full functionality, the use of an HTML5 compliant

browser with JavaScript enabled is required.

Ethernet Connection:

Connection switch/router with auto

‑negotiation capability to identify the Auto‑reader as

operating at 10 Mbps and half

‑duplex, or able to be manually configured as 10 Mbps

and half

‑duplex.

Connecting to the 3M

™ Attest Autoreader 490H Web App

To use the 3M™ Attest™ Auto-reader 490H Web App, the 3M™ Attest™ Auto-reader

490H must be connected to the facility network using the supplied Ethernet cable. Consult

with your facility IT personnel for assistance with network connectivity. Each 3M™

Attest™ Auto-reader 490H has a unique MAC Address which is presented on the unit

’s

LCD display when the user depresses the Info button three times. The MAC Address is also

provided at the bottom of the 3M™ Attest™ Auto-reader 490H Web App Configuration

page. Communication occurs using the http protocol over Port 80. The 3M™ Attest™

Auto-reader 490H does not collect, process, store, or transmit any Protected Health

Information (PHI). Web App Users may connect to the 3M™ Attest™ Auto-reader 490H

Web App using a URL based upon either the 3M™ Attest™ Auto-reader 490H serial

number or the IP Address. To view the 3M™ Attest™ Auto-reader 490H Web App from a

wireless device such as a mobile hand-held device or a computer on a sub-net different

from that to which the 3M™ Attest™ Auto-reader 490H is connected, use the IP Address

URL.
Note: To access the 3M™ Attest™ Auto

‑reader 490H Web App within a secure network,

the PC or mobile device must have access to the secure network; options include

connecting via a network Ethernet cable, signing in to the facility

’s wireless network, or

connecting via a virtual private network (VPN).

A. Serial number URL

1. Connect the supplied Ethernet cable from the 3M™ Attest™ Auto

‑reader 490H to an

Ethernet jack.

2. Depress the

button once to display the 3M™ Attest™ Auto

‑reader 490H 6‑digit

serial number on the left side of the top row of text on the LCD display.

3. Enter http://attestxxxxxx, where xxxxxx represents the unit

’s serial number (e.g., http://

attest221008) from Step 2, in the PC web browser address bar and press Enter.

4. The 3M™ Attest™ Auto

‑reader 490H Web App Status page will display on the PC. For

future ease of use, add this page to your web browser

“Favorites.”

B. IP Address URL

The 3M™ Attest™ Auto

‑reader 490H Web App may also be accessed using either a

dynamic or static IP address.

1. Dynamic IP Address

A dynamic IP address is assigned when the Ethernet cable is connected from the

3M™ Attest™ Auto

‑reader 490H to a live Ethernet jack.

Press and release the

button twice to display the dynamic IP address for the

3M™ Attest™ Auto

‑reader 490H. Enter http://IPaddress (e.g. http://123.456.789.012) in

the web browser address bar of the PC or mobile hand

‑held device and press Enter.The

3M™ Attest™ Auto

‑reader 490H Web App Status page will display.

2. Static IP address

Some facility IT personnel may require devices connecting to the network to use a Static

IP address. If this is the case at your facility, contact the IT department to request a Static

IP address.
Record the static IP address provided by your facility IT department here: ___________.

You may wish to label the Ethernet jack with the assigned address. Enter

http://StaticIPaddress (e.g. http://111.222.333.444) in the web browser address bar on

your PC or mobile hand

‑held device and press Enter.The 3M™ Attest™ Auto‑reader 490H

Web App Status page will display.

About the 3M

™ Attest Autoreader 490H Web App Pages

The 3M™ Attest™ Auto

‑reader 490H Web App includes four pages.

a) Status page

Status

History

3M™ Attest™ Auto-reader 490H

ATTEST 1295

ATTEST 1295

Auto-reader 490H

1

2

3

4

5

+

24

6

7

8

9

10

SN

200299

2017-05-11 17:13

1. User

‑entered nickname (optional)

2. Well Configuration (1

‑5 and 6‑10)

3. Well Number
4. BI Result/Remaining Incubation Time
5. Date and Time
6. 3M™ Attest™ Auto

‑reader 490H Serial Number

The Status page provides a real

‑time representation of the 3M™ Attest™ Auto‑reader

490H LCD panel display. The current date and time and 3M™ Attest™ Auto

‑reader 490H

serial number are also indicated on this page. From this page, the user may navigate to:
• the History page by clicking on History on the left of the screen.

• the Results Detail page by clicking on the well number of an occupied well (i.e., a well

that currently has an incubating BI). Clicking on an unoccupied well takes the user to

the History page.

 


background image

10

11

1

b) Results Detail page

3M™ Attest™ Auto-reader 490H Results Detail

Status

History

Print

Result

Start Time
Well# and Configuration
490H Serial Number

Control?

BI Lot#

Load#

Sterilizer#

Technician

Chemical Integrator?

Implant?

Cycle Parameters

Notes

no

2018-12DA

1

6

sdf

n/a

n/a

n/a

Daily control BI

2017-05-11 08:05:42

#2 1295

200299

This page provides an individual record for an incubated BI. For complete documentation,

the user may print a hard copy and/or save the record as an electronic file.
Note 1: The top four rows (highlighted in green) are populated automatically by the

3M™ Attest™ Auto

‑reader 490H and cannot be changed by the user.The remaining rows

are completed by the user to satisfy the documentation requirements of their facility.
Note 2: The Results Detail page refreshes less frequently that the Status page. Until the BI

result is available, the Results Detail page displays remaining minutes of incubation in the

results field.
c) History page

Status

History

3M™ Attest™ Auto-reader 490H

Well# and Configuration

#3 1295
#2 1295
#1 1295
#10 1295
#3 1295
#2 1295
#1 1295
#4 1295
#3 1295
#2 1295

Start Time

2017-05-11 13:51:49

2017-05-11 08:05:42
2017-05-11 08:03:56
2017-05-07 11:55:16
2017-05-07 11:06:44
2017-05-07 08:03:19
2017-05-07 08:02:43
2017-05-04 08:57:51
2017-05-04 08:57:12
2017-05-04 08:01:47

Result

---

+

+

ID

1
2
3
4
5
6
7
8
9

10

The 3M™ Attest™ Auto

‑reader 490H stores results for the last 100 incubated BIs on

embedded software. The 3M™ Attest™ Auto

‑reader 490H Web App History page provides

a summary of these last 100 results.
d) Configuration page
This page allows the configuration of the network and language settings for the

3M™ Attest™ Auto

‑reader 490H from the 3M™ Attest™ Auto‑reader 490H Web App.

Documenting BI Results using the 3M

™ Attest Autoreader 490H

Web App

Status

History

3M™ Attest™ Auto-reader 490H

ATTEST 1295

ATTEST 1295

Auto-reader 490H

1

2

3

4

5

+

24

6

7

8

9

10

SN

200299

2017-05-11 17:13

1.

Open the Results Detail page

After inserting a new 3M™ Attest™ Rapid Readout BI in the 3M™ Attest™

Auto

‑reader 490H, it is a best practice to open the 3M™ Attest™ Auto‑reader 490H

Web App Results Detail page for that BI by clicking on the appropriate well number

from the Status page.

2.

Enter the specific information for that BI (e.g., BI Lot #, sterilizer #, load #, technician

name, etc.) in the provided editable fields. Use the Notes section to capture

information not prescribed in the provided row titles; for example, you may wish to use

this field to record load items.

3M™ Attest™ Auto-reader 490H Results Detail

Status

History

Print

Result

Start Time
Well# and Configuration
490H Serial Number

Control?

BI Lot#

Load#

Sterilizer#

Technician

Chemical Integrator?

Implant?

Cycle Parameters

Notes

no

2018-12DA

1

6

sdf

n/a

n/a

n/a

Daily control BI

2017-05-11 08:05:42

#2 1295

200299

3. The entered information is

saved automatically to temporary web browser storage on

the user

’s PC every 60 seconds, or by leaving the Results Details page.

4.

Print/File. Once the BI result is available, print or file the Results Detail page to create

a record. The page may be physically printed and/or saved as an electronic file.

Important! Data is only stored for the last 100 incubated BIs.

Embedded software in the 3M™ Attest™ Auto

‑reader 490H saves the data from the

auto

‑populated (i.e., green highlighted) fields.The application relies on the temporary

storage in the user

’s web browser to save the data in the user‑populated fields. In

both cases, data is only stored for the last 100 records, i.e., the 101st incubated BI will

overwrite the information saved for the 1st incubated BI. To retain the Results Detail

information for future reference it is best practice to print the page or save to an electronic

file as soon as the BI result is available.

 


background image

10

11

1

Using the BI History Page

Status

History

3M™ Attest™ Auto-reader 490H

Well# and Configuration

#3 1295
#2 1295
#1 1295
#10 1295
#3 1295
#2 1295
#1 1295
#4 1295
#3 1295
#2 1295

Start Time

2017-05-11 13:51:49

2017-05-11 08:05:42
2017-05-11 08:03:56
2017-05-07 11:55:16
2017-05-07 11:06:44
2017-05-07 08:03:19
2017-05-07 08:02:43
2017-05-04 08:57:51
2017-05-04 08:57:12
2017-05-04 08:01:47

Result

---

+

+

ID

1
2
3
4
5
6
7
8
9

10

To view or print an individual record, click on the ID number of the desired record to

navigate to the Results Detail page for that BI.
Note 1: Column 1,

“ID” is the assigned ID number with ID 1 representing the newest

record and ID 100 representing the oldest record. For convenience, all columns are

sortable; to help find a particular record, simply click once on the column heading to sort

in ascending order and click a second time to reverse the order.
Note 2: The History page refreshes less frequently than the Status page. Until the BI result

is available, the History page displays

••• in the Results column indicating incubation is

still in

‑process.

Using the Configuration Page

Certain set

‑up and configuration options are available on the password‑protected

3M™ Attest™ Auto

‑reader 490H Web App Configuration page. Ideally, the 3M™ Attest™

Auto

‑reader 490H should be empty (i.e., have no incubating BIs) when it is reconfigured.

Navigate to the Configuration page by entering either:
1) http://attestxxxxxx/protect/config.htm (where xxxxxx is the 6

‑digit unit serial number), or

2) http://xxx.xxx.xxx.xxx/protect/config.htm (where xxx.xxx.xxx.xxx is the IP address)
in the web browser address bar and pressing Enter. A security screen will appear. Fill in

the fields as follows:
User name: manager
Password: Attest
and click OK.

Click on the desired radio buttons to change settings.

Language

Selected setting indicates language in which text on 3M™ Attest™ Auto

‑reader 490H Web App pages will appear on the PC/mobile device screen.

Pushbutton

Configuration

Selecting

Enable  allows the user to configure the 3M™ Attest™ Auto

‑reader 490H from the buttons on the unit itself.

Selecting

Disable  prevents the user from being able to configure the 3M™ Attest™ Auto

‑reader 490H from the buttons on the unit itself.

Buzzer Configuration

Selecting

Enable  enables the audible alarm. The speaker icon will appear on the 3M™ Attest™ Auto

‑reader 490H LCD panel.

Selecting

Disable  disables the audible alarm. The speaker icon will disappear from the 3M™ Attest™ Auto

‑reader 490H LCD panel.

Attest Auto-reader

490H Nickname

Naming the 3M™ Attest™ Auto

‑reader 490H may be useful in facilities with multiple units. The assigned nickname will appear on the 3M™ Attest™

Auto

‑reader 490H Web App Status page.

Enable DHCP

Default: Setting is checked indicating the Web App will use the Dynamic IP address automatically assigned when the 3M™ Attest™ Auto

‑reader 490H is

connected to the network. Remove the check if you wish to use a Static IP address assigned by your facility IT.

IP Address

Enter Static IP address assigned by IT.

Gateway

Enter Gateway.

Subnet Mask

Enter Subnet Mask.

Primary DNS

Enter Primary DNS.

Secondary DNS

Enter Secondary DNS.

MAC Address

XX:XX:XX:XX:XX:XX

(Unique MAC address assigned to device. This value cannot be changed.)

Use Computer Time

Check this box if you wish to set the clock on

‑board the 3M™ Attest™ Auto‑reader 490H using the computer’s clock.

Attest Auto-reader

490H Time

Alternatively, leave the Use Computer Time box unchecked and complete the date and time boxes to set the 3M™ Attest™ Auto

‑reader 490H clock.

After changing desired settings, click on Save Config button to save your changes. A new screen confirming the settings were successfully changed appears.

 


background image

12

1

TROUBLESHOOTING THE 3M

™ ATTEST AUTOREADER 490H WEB APP

Issue

Problem

Solution

Unable to access 3M™ Attest™

Auto

‑reader 490H Web App on

networked computer

3M™ Attest™ Auto

‑reader 490H and/or

computer not connected to network.
Auto

‑negotiation issue between the

3M™ Attest™ Auto

‑reader 490H and facility

network switch.

Ensure 3M™ Attest™ Auto

‑reader 490H Ethernet cable is connected to a live jack and

that connection to 3M™ Attest™ Auto

‑reader 490H is secure.

Ensure computer is connected to network.
If failure is with connection attempted using 3M™ Attest™ Auto

‑reader 490H serial

number URL, try connecting using IP address URL.
Switch port setting must be set at 10 Mbps and half

‑duplex.

Contact facility IT or 3M if problem persists.

Unable to access 3M™ Attest™

Auto

‑reader 490H Web App on

mobile device

3M™ Attest™ Auto

‑reader 490H not connected

to network.
For security reasons, facility firewall may prevent

mobile devices not connected to the facility

network from connecting to secure IP addresses.

Ensure 3M™ Attest™ Auto

‑reader 490H Ethernet cable is connected to a live jack and

that connection to 3M™ Attest™ Auto

‑reader 490H is secure.

Contact facility IT for their recommendation on connecting to the secure network.

Solutions may include enabling Wi

‑Fi on the mobile device and signing into the facility

network or connecting to the facility virtual private network (VPN) on the mobile device.

Data entered by user on Results

Detail page disappears

User entered data is written to temporary

web browser storage. Browser may have

cleared data.

Set web browser to accept (allow or enable) cookies.
As a best practice, print or save Results Detail record as soon as BI result is final.

BI result displayed on

3M™ Attest™ Auto

‑reader 490H

LCD display does not appear on

Results Detail page

The Results Detail page has not refreshed yet.

Use your browser to refresh the Results Detail page, or wait up to 60 seconds for the

page to automatically refresh.

Results Detail page will not open

from the Status page

The Results Detail page only opens from the

Status page for occupied 3M™ Attest™

Auto

‑reader 490H wells.

Do not attempt to navigate to the Results Detail page from unoccupied wells on the

Status page.

REPAIR AND REPLACEMENT

In the U.S.A., 3M™ Attest™ Auto

‑readers 490H must be repaired at:

3M Health Care Service Center

Suite 200, Bldg. 502

3350 Granada Avenue North

Oakdale, MN 55128

1

‑800‑292‑6298

Fax: 1

‑800‑770‑8016

Outside of the U.S.A., contact your local 3M Subsidiary.
If you have questions, call our Customer Service number: 1

‑800‑292‑6298.

Made in the U.S.A. of globally sourced materials by 3M Health Care.

3M Health Care

2510 Conway Ave

St. Paul, MN 55144

1

‑800‑228‑3957

www.3M.com/healthcare
© 2017, 3M. All rights reserved.
3M and Attest are trademarks of 3M.

Used under license in Canada.
Issue Date: XXXX-XX

3M Deutschland GmbH

Health Care Business

Carl-Schurz-Str. 1

41453 Neuss

Germany

 


background image

 


background image

Made in U.S.A. by

3M Health Care

2510 Conway Ave.

St. Paul, MN 55144

1-800-228-3957
3M.com/Medical         

3M Deutschland GmbH

Health Care Business

Carl-Schurz-Str. 1

41453 Neuss

Germany

© 2017, 3M. All rights reserved.

3M and Attest are trademarks of 3M.

Used under license in Canada.
Issue Date: 2017-03

34-8720-4946-4