background image

Part No. DNA1750-0AAA02 
Published April 2004

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 

S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

Related Documentation

Please use these notes in conjunction with the following 
documents:

SuperStack 3 Switch 3226 and Switch 3250 Getting 
Started Guide

Part number: DUA1750-0AAA01
(supplied with your Switch and in PDF format on the 
3Com Web site)

SuperStack 3 Switch 3226 and Switch 3250 
Implementation Guide

Part number: DUA1750-0BAA01
(supplied in PDF format on the CD-ROM that 
accompanies your Switch and on the 3Com Web 
site)

SuperStack 3 Switch 3226 and Switch 3250 
Management Quick Reference Guide

Part number: DQA1750-0AAA01
(supplied with your Switch and in PDF format on the 
3Com Web site)

SuperStack 3 Switch 3226 and Switch 3250 
Management Interface Reference Guide
” 
Part number: DHA1750-0AAA01
(supplied in HTML format on the CD-ROM that 

accompanies your Switch and on the 3Com Web 
site)

You can obtain the latest technical information for your 
Switch, including a list of known problems and 
solutions, from the 3Com Knowledgebase:

http://knowledgebase.3com.com

Software License Agreement

Before you use the Switch software, please ensure that 
you read the license agreement text. You can find the 
license.txt file on the CD-ROM that accompanies your 
product, or in the self-extracting exe that you have 
downloaded from the 3Com Web site.

About this Software Version

This software provides support for the following:

Switch 3226 (3CR17500-91)

Switch 3250 (3CR17501-91)

The software does not operate on any other 3Com 
Switch.

 


background image

2

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

The software is available in two versions:

s3201_02.bin — Provides normal levels of 
encryption with keys of up to 56 bits in length.

s3201_02s.bin — Provides higher levels of 
encryption including 168-bit 3DES and 
256-bit AES.

The Switch ships with software providing normal 
levels of encryption.

Errors and Omissions

The 

system console speed

 command is 

available on the unit but has been omitted from the 
SuperStack 3 Switch 3226 and Switch 3250 
Management Quick Reference Guide”
 and the 
SuperStack 3 Switch 3226 and Switch 3250 
Management Interface Reference Guide
”.

To change the speed of the console port:

1

Enter 

system console speed

 from the top-level 

menu of the Command Line Interface. 

2

Enter the speed at which you want to set the console 
port or 

?

 to see a list of available speeds.

SuperStack 3 Switch 3226 and Switch 3250 Getting 
Started Guide

Pages 15 and 16 contain the following statement:

“The console port uses a standard null modem 
cable and is set to auto-baud, 8 data bits, no parity 
and 1 stop bit.”

This is incorrect. It should read:

“The console port uses a standard null modem 
cable and is set to 19200 baud, 8 data bits, no 
parity and 1 stop bit.”

If you change the speed, make a note of the new 
setting. If you cannot connect using the console port 
and do not know the speed at which it is set, connect 
using a network port and enter the

 

system console speed

 command to check the 

speed of the console port.

Enhancements and Fixes for Known Faults

The following features and enhancements are 
supported in version 1.02.

Web Interface

The unit only allows printable ASCII characters, with 
character codes between 32 and 127, to be used for 
strings such as the unit location or VLAN name. 
Characters such as those used for accented letters in 
non-English languages are rejected. In previous 
firmware these characters where rejected with a 

 


background image

Errors and Omissions

3

Data is invalid

 error with no explanation. The 

new firmware returns an error describing the field 
containing the error and then returns to the page 
allowing the error to be corrected.

Command Line Interface

The output of the 

bridge port summary

 CLI 

command has been improved:

The 

stpState

 field has been replaced by 

Link

 

and 

Spanning Tree

 columns to more accurately 

report the active port status.

The 

fwdTransitions

 field has been renamed 

Forward Trans

.

The 

LACP PartnerID

 field now reports 

LACP disabled

 if the protocol is disabled or not 

supported on the port.

The output of the 

bridge port detail 

CLI 

command has been improved:

The 

stpState

 field has been added. This shows if 

the Spanning Tree Protocol (STP) has been enabled 
on the port. The field will read 

Enabled

 if STP is 

enabled on the port, even if STP is disabled globally 
on the unit.

The currently active spanning tree state for the 
port is reported in the 

Spanning Tree

 column 

of the VLAN table. Please note that the product 
supports a single spanning tree state for all VLANs 
as per the 802.1d Spanning Tree specification. It 
does not support 802.1s Spanning Tree per VLAN.

The 

LACP PartnerID

 field now reports 

LACP disabled

 if the protocol is disabled or not 

supported on the port.

Traffic Prioritization

In previous versions of the software, the DSCP 
prioritization of the CS6 code point defaulted to 
802.1d priority 7. This has been corrected. The CS6 
code point now defaults to 802.1d priority 6.

VLANs

In previous versions of the software, removing a port 
from a VLAN left static entries bound to the 
port-VLAN. This has been fixed. When you remove a 
port from a VLAN all static entries for that port-VLAN 
will be deleted.

802.1x Network login authentication:

In previous versions of the software, authentication 
attempts for valid users would occasionally fail. 
The bug causing this has been fixed.

The user name reported in the CLI command 

security network access detail

 was 

occasionally displayed with incorrect trailing 
characters. This has been fixed. The user names are 
now displayed correctly.

 


background image

4

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

RMON history statistics and Web port history 
statistics

A bug in previous software versions prevented 
statistics being generated for the first timing interval. 
This has now been fixed.

In previous software versions the 1 hour statistics did 
not appear until the unit had been running for 
2 hours. The statistics would then be correctly 
generated on an hourly interval. This has now been 
fixed. 1 hour statistics are available after 1 hour.

Similarly the 6 hour statistics would not appear until 
the unit had been running for 12 hours and then 
update every 6 hours. This has now been fixed. 
6 hour statistics are available after 6 hours.

Software Version Number

The software version number reported by the 

system control swapSoftware

 CLI command 

is displayed incorrectly in previous versions of the 
software. For example, software version 1.01 displays 
the version as 

1.1

When running the 1.02 or later software, it displays 
all software versions correctly, including 1.00 and 
1.01.

The 

system control swapSoftware

 command 

does not include an indication of the encryption level 
supported by the firmware; the firmware supporting 
the normal encryption level 
1.02, and the strong 
encryption firmware 
1.02s both appear as 

1.02

 

when using this command. The encryption level of 

the current firmware can be verified by running the 

system summary

 command:

Static port security and the bridge MAC address 
table

If static port security is enabled on a port with more 
than 200 addresses the previous software versions 
would report that the command had failed, but 
would add the first 200 addresses to the bridge 
address table and move the port into the secure state.

In addition, disabling port security would occasionally 
fail to flush the secure addresses from the bridge 
address table.

The current software correctly rejects the attempt to 
move the port into secure mode if there are more 
than 200 addresses. When this condition occurs it 
does not change the port security mode or make any 
of the addresses secure. In addition, disabling port 
security always removes all static bridge address 
entries from the port.

Binding an ACL to a port fails occasionally

In previous versions of the software, the unit would 
incorrectly count the number of ACL rules when 
trying to determine whether the ACL could be bound 
to the port.

This has been fixed. In the current software version 
the software correctly allows for an ACL to be bound 
if it is within the limits of the particular port. 

 


background image

Updating the Switch Software

5

See “Access Control Lists” in the “Points to Note 
when using the Switch 3226 and Switch 3250” 
section of this document for further details.

3Com Network Supervisor Discovery

When using 3Com Network Supervisor with previous 
versions of the software, 3Com Network Supervisor 
was unable to display the unit on the network 
topology. This will prevent you from using 3Com 
Network Supervisor to update the software from 1.00 
or 1.01.

This has been fixed. The Switch running software 
version 1.02 and above can be discovered successfully 
using 3Com Network Supervisor and the correct 
network topology generated.

Updating the Switch Software

Software Updates are the bug fix and maintenance 
releases for the version of software initially purchased 
with the product. In order to access these Software 
Updates you must first register your product on the 
3Com Web site at:

http://eSupport.3com.com/

First time users will need to apply for a user name and 
password. A link to software downloads can be found 
from this 

http://eSupport.3com.com/

 page, or 

located from the 

www.3Com.com

 home page.

To update the software on the Switch, do the follow-
ing:

1

Locate the software update for the Switch and run 
the (

filename.exe

) executable file.

2

If necessary, download the TFTP server applications 
into the management station.

3

Install the TFTP server (file name 

3ts01_04.exe

) on 

a Microsoft Windows 95, 98, NT, 2000 or XP 
machine.

4

Launch the TFTP server application.

5

Point the Upload/Download default directory on the 
TFTP server to the directory where the upgrade file is 
located. 

6

Make sure the Switch being upgraded has an IP 
address assigned to it.

7

Telnet to the Switch.

a

To Telnet to the Switch, click Start in Microsoft 
Windows 95, 98, NT, 2000, or XP machine.

b

Click Run.

c

In the text area, type 

telnet IP address

d

Click OK.

8

Press Enter to receive a login prompt.

9

Log into the Switch management.

a

The default user login is 

admin

.

b

There is no default password for admin (press 
Enter).

10

From the main menu, select System, then select 
Control.

 


background image

6

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

11

Select SoftwareUpgrade.

12

Enter the IP address of the TFTP server connected to 
the Switch.

13

Enter the upgrade file name.

a

The message will appear, '

Software Upgrade 

in progress.....'

.

b

The entire time the upgrade is in process, the 
Power/Self test LED will flash ON/OFF Green, and a 
series of dots will indicate that the upgrade is 
progressing successfully.

c

When the software upgrade is complete, the 
Switch will reboot itself.

Points to Note when Upgrading Software

The Switch ships with a version of software that 
supports up to 56-bit encryption for SSH and SSL 
(HTTPS). For higher levels of encryption including 
168-bit 3DES and 256-bit AES, download the 
strong encryption version of the Switch software 
from the 3Com Web site and install as detailed in 
“Updating the Switch Software” above. 

When you have a strong encryption version of the 
Switch software loaded, the Software Version field 
on the Web interface will show the version 
number of the software followed by the words 

(Strong encryption)

.

When initiating a TFTP upgrade using the Web 
interface or CLI, if an incorrect TFTP server IP 
address or software upgrade filename is entered 
you will not be able to correct the IP address or 

filename until the TFTP upgrade operation has 
timed out. The default time out period is 1 minute.

When attempting to upgrade the software on the 
unit it may occasionally report the following error:

Error: File service in progress.

If you encounter this error, please wait a minute 
and try the command again.

Points to Note when using the Switch 3226 
and Switch 3250

Password Recovery

The password recovery feature allows you to reset the 
admin user password by logging into the unit via the 
console port using the username 

recover

 and 

password 

recover

. If you power cycle the unit 

within 30 seconds then the password will be reset 
and you will be prompted to enter a new password 
on restart. There is no command to disable the 
password recovery feature.

Configuring Link Aggregations

When creating a manual aggregation between two 
systems the ports in the aggregation must not be 
physically connected together until the aggregation 
has been correctly configured at both ends of the 
link. Failure to configure the aggregation at both ends 
before physically connecting the ports can result in a 
number of serious network issues such as lost packets 
and network loops.

 


background image

Points to Note when using the Switch 3226 and Switch 3250

7

3Com recommends that you set individual ports that 
are to be members of an aggregated link to the same 
VLAN membership. This ensures communication 
between all VLANs at all times.

Telnet and HyperTerminal

Accessing the Command Line Interface via Telnet or 
Windows HyperTerminal using TCP/IP may not work 
correctly on some platforms unless it has been 
configured to send line feeds with carriage returns. To 
set this for Telnet enter 

set crlf

 when in command 

mode. To set this for HyperTerminal click on the 
Settings tab in the Properties screen, click ASCII Setup 
and ensure that Send line ends with line feeds is 
checked within the ASCII Sending section.

You should not configure HyperTerminal in the above 
way if you are using a console cable to make a direct 
connection to the Switch.

Accessing the Command Line Interface is not possible 
using the default Telnet program supplied with Win-
dows XP. Use another Telnet program, such as Hyper-
terminal. See the 3Com Knowledgebase for updates 
and a solution, when available:

http://knowledgebase.3com.com

Port Security and Authentication

When enabling the static port security feature on a 
port the Switch will report static fail if you exceed 
the maximum number of secure addresses (200). 
The unit will not move the port into secure mode. 
3Com recommends that port security be enabled 

on only edge ports which will typically have only a 
few addresses.

If the address of a device is added as a static secure 
address on one port and then it is subsequently 
moved to a different port with security disabled 
then the device may get intermittent network 
connectivity. To fix this problem you should remove 
the address from the original port and consider 
enabling security on the new port. 

When configuring RADIUS using the CLI command 

security radius setup

 you should note that 

the wizard does not include a step to configure the 
RADIUS shared secret. You will need to configure 
the shared secret using the 

security radius 

sharedSecret 

command before RADIUS will 

operate.

The Switch does not log authentication requests or 
support logging to a RADIUS accounting server. 
Please use the logs generated on your RADIUS 
authentication server instead. 

To create a user with administrator privileges when 
using RADIUS device authentication you must 
ensure that user has the “Service-Type” attribute 
set to 15.

Some RADIUS servers will not authenticate users 
with a blank password, all user accounts should 
have a valid password configured.

Link aggregation and Gigabit ports

When manually configuring an aggregated link the 
switch may report the following error message:

 


background image

8

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

No more ports may be added to aggregated 

link.

You should check the configuration of the 
following items on the physical port

port security is disabled on the port.

The VLAN membership of the port matches that 
of the aggregated link

LACP is disabled. 

No ACL is bound to the port.

If you attempt to enable LACP on a port which is 
currently a manual member of a link aggregation 
then the following error will be displayed:

Failed to set port 1:50 lacp status

If you wish the ports to automatically form a trunk 
using LACP then the ports must first be removed 
from the manual aggregation.

If a trunk is disabled by using the 

bridge 

linkAggregation modify linkState

 CLI 

command then the physical trunk member ports 
for the aggregation will be disabled. A side effect 
of the ports being disabled is that they will no 
longer negotiate to become LACP-trunk members. 
If the trunk was formed by LACP then the trunk 
will disappear because it no longer has any 
member ports.

If the LACP trunk is disabled as above then 
attempting to enable the trunk with the 

linkState

 command will respond with an error 

that the trunk can not be configured. In order to 
form the LACP trunk you must manually re-enable 
the individual trunk member ports using the 

physicalInterface ethernet portState

 

CLI command

SFP Modules

When adding or removing SFP modules the switch 
will reset a number of port parameters. 3Com 
recommends that you verify the following port 
parameters after adding or removing an SFP module:

Media configuration (auto negotiation, speed and 
duplex)

Link Aggregation membership.

LACP state.

Spanning tree port parameters. 

VLAN membership.

IP Configuration and Routing

The Switch is optimized to operate as an edge 
router with a single default gateway acting as the 
next hop route to all other subnets. 

In larger networks it may take several minutes for 
the unit to learn the correct routing information. 
The unit may have to flush and relearn the routing 
information if there is a topology change in the 
network. During this time the network connectivity 
may be intermittent. 

In certain situations, the Switch will be unable to 
used hardware routing display the following error 
message in the system summary and route table:

Current network configuration requires use of 

software routing, resulting in degraded 

performance.

 


background image

Points to Note when using the Switch 3226 and Switch 3250

9

This message can be caused by one of the 
following situations:

if there are more than14 routes whose next hop 
is not the default gateway. 3Com recommends 
reconfiguring the network so that the uplink 
from the Switch goes directly to another layer 3 
router which is configured as the default gate-
way.

if the unit is unable to contact one or more of 
its next-hop routers then software routing will 
be used. Find the reason why the router cannot 
be contacted and correct the problem.

if there is no default gateway configured. Con-
figure a default gateway and check to see if the 
problem is solved.

when the Switch is learning new routes. The 
Switch may take up to a minute to learn new 
routes. The above message may be displayed 
for a short time while a route is learned. This is 
normal behavior.

When the unit is in the default IP mode of auto it 
will attempt to contact a DHCP server on the 
network to obtain an IP address. If there is no 
DHCP server available on the network then the 
unit will not be accessible using TCP/IP.

Please use the console to configure the unit with 
an IP address or connect the unit to a network 
with a DHCP server. If using DHCP you will need to 
use a console connection or log information from 
your DHCP server to discover the address which 
has been assigned to the unit.

Reconfiguring an IP interface may cause the RIP 
configuration and static routes settings for that 
interface to be lost.

When adding or modifying an IP interface the CLI 
and Web interface may appear to hang for up to 
30 seconds while the operation takes place. 

When forwarding DHCP and BOOTP requests in a 
multinetted environment, the UDP helper will only 
use the primary IP interface in the forwarded 
requests. This will cause the BOOTP/DHCP server to 
allocate all dynamic addresses from the primary 
subnet of a multinetted VLAN. 

If the number of multicast traffic groups on your 
network exceeds the maximum supported by the 
Switch (64) then you may see occasional bursts of 
multicast traffic as the Switch updates its internal 
configuration.

Some combinations of IP commands in a 
multinetted environment may cause the IP address 
of interface 1 to become a secondary address. 
Rebooting the unit will reset this interface as the 
primary address. There is no other means of 
clearing this condition.

Access Control Lists

When trying to bind an Access Control List (ACL) to a 
port you may see the following error generated:

Fail to bind port 26 ACL

This error will appear if:

 


background image

10

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

The ACL which is being bound has more rules than 
can be accommodated by the hardware. The 
number rules available depends on the port type:

10/100 Ports - At least 15 rules per port

10/100/1000 Ports - Maximum of 2 rules per 
port.

You try to bind an ACL to a port which forms part 
of an aggregated link, or a port that has LACP 
enabled.

The Switch supports ACLs based on IP addresses and 
port ranges rather than VLAN IDs. To set up ACLs to 
restrict routing between VLANs, each VLAN should 
comprise a clearly defined subnet.

ACLs should not be used on inter-switch links as they 
may interfere with routing messages required for 
normal network operation.

Traffic Prioritization

There is no CLI command available to remove IP 
port based traffic prioritizations. If you wish to 
remove these entries you must either use the Web 
interface or initialize the unit.

The IP Port traffic prioritization only examines the 
destination port number field of TCP and UDP 
frames when determining the priority of the 
packet. This may result in the request and response 
frames being prioritized differently as they traverse 
the network.

The Switch prioritizes traffic internally but does not 
mark or remark packets other than NBX packets. 

NBX traffic is remarked to DSCP 46 and 802.1d 
priority 6.

VLAN Configuration

Every port on the unit must be an untagged member 
of a single VLAN. Every port defaults to being an 
untagged member of VLAN1. If you add the port as 
an untagged member of another VLAN then this will 
replace the VLAN1 membership. If the port is an 
untagged member of a VLAN other than 1, then 
removing membership of this VLAN will cause the 
port to return to being an untagged member of 
VLAN1. The unit will respond with the following error 
if you attempt to remove the untagged membership 
of VLAN1:

Failed to delete untagged port 1:2 from VLAN 

1

Management via SNMP / MIBs

Items configured using SNMP/MIB will be lost 
when the unit is power cycled. 3Com recommends 
that the CLI and Web interfaces are used to 
configure the unit instead.

The counters for the etherStatsPkts(64~1518) MIB 
item count traffic which is sent and received by the 
unit. This does not conform to the MIB which 
states that it should count only received packets.

Small variations in the sampling of traffic statistics 
may cause the unit to incorrectly measure the 
traffic rates used for RMON alarms. To minimize 
the generation of incorrect alarms 3Com 
recommends that they are configured with a 

 


background image

Points to Note when using the Switch 3226 and Switch 3250

11

minimum sampling period of 10 seconds and a 
minimum hysteresis of 20%.

SSH Management

The SSH server in the unit will reject all connection 
requests unless the unit has a SSH host key. This 
host key may be generated using the Security > 
Device > SSH > Server Auth > Key Gen
 command 
on the Web interface. You may wish to keep a 
record of the host key to allow you to confirm the 
identity of the switch when connecting remotely 
using SSH.

If the unit reboots while using SSH you may have 
to manually restart your SSH client to reconnect 
once the unit has restarted.

HTTPS Management

The secure Web server on the unit is supplied with 
a default certificate which will fail the browsers 
security checks and an error message like the 
following will be generated:

The name on the security certificate is 

invalid or does not match the name of the 

site.

It is not possible for 3Com to ship a certificate with 
the unit that will satisfy these security checks. The 
browser will normally allow you to accept the 
connection regardless. All of the data which is sent 
between the browser and the unit will be securely 
encrypted. You may upload your own valid 
certificate to the switch if you want to avoid these 
warnings. The software to generate these 
certificates is beyond the scope of this document.

The presence of both a secure (HTTPS) and 
insecure (HTTP) Web interface on a single unit 
causes some browsers to incorrectly report the 
following warning message:

This page contains both secure and insecure 

items. Do you wish to proceed?

This warning message may be safely ignored. All 
traffic to and from the unit using the HTTPS 
interface is encrypted. Alternatively you may try 
clearing the Web cache or upgrading your browser 
to the latest version.

Saving Configuration

When making configuration changes to the 
Switch, do not reboot or turn off the unit for at 
least 10 seconds after the last configuration 
change. If the unit is rebooted or switched off 
before the 10 seconds is complete the 
configuration changes may be lost.

Device Backup and Restore

When the unit backs up the configuration file a 
number of security sensitive settings such as the 
user accounts, RADIUS shared secret and 
community strings are not backed up. The 
comments in the configuration file indicate that 
these commands may be manually appended to 
the end of the file. Contrary to these instructions, 
3Com recommends that you restore the un-edited 
configuration file and manually reconfigure the 
security parameters using the CLI or Web interface.

In some scenarios backing up the configuration on 
one unit and restoring it on another will cause the 

 


background image

12

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

default gateway setting to be lost. You should 
always check the IP address and route 
configuration when restoring the configuration on 
another unit.

IGMP

Disabling IGMP when there are hosts subscribing to 
multicast IP streams may prevent clients from 
subscribing to multicast IP groups. Hosts may be 
unable to re-subscribe to the same multicast IP group, 
for more than 5 minutes, or until the unit is 
re-booted.

Spanning Tree

When connecting switches together, 3Com 
recommends that spanning tree fast start should 
be disabled on the interconnecting ports (it is 
enabled by default on all 10/100 ports and 
disabled by default on 10/100/1000 and SFP 
ports). This can be done using the Physical 
Interface > Ethernet > Setup
 command on the 
Web interface. 

When connecting switches together, if spanning 
tree fast start is not disabled on the 
interconnecting ports, any previously learned 
addresses on links that become blocked will not 
correctly age out until the aging time has passed. If 
the switch is power cycled then the device will 
learn the addresses correctly.

You must enable spanning tree before making 
changes to spanning tree settings. If you try to 
change spanning tree settings while the protocol is 

disabled the following error messages will be 
generated:

Failed to set forward-time

Failed to set hello-time

When you enable spanning tree, all spanning tree 
settings are reset to their default values. If you 
want to use custom settings for spanning tree, you 
must configure spanning tree after enabling it.

Roving Analysis Port

When the roving analysis port feature is activated 
the analyzer should see a copy of all packets sent 
and received by the mirror port. The switch does 
not currently mirror frames sent by the 
management CPU of the switch itself. The analyzer 
port will therefore be unable to show 
management traffic from the unit or protocol 
control packets such as RIP which are being sent 
out of the mirror port.

While the analyzer port is active it still operates as 
a normal network port, allowing traffic to be 
switched to and from other network ports. You 
must be careful to differentiate traffic seen by the 
analyzer which is from the mirror port and other 
network traffic which may be being sent through 
the analyzer port.

The traffic sent out of the analyzer port follows the 
VLAN membership setup for the analyzer port and 
not the mirror port. You must manually 
reconfigure the VLAN membership of the analyzer 
port to match the mirror port or you will not see 
the correct tagged / untagged packets on the 
analyzer.

 


background image

Points to Note when using the Switch 3226 and Switch 3250

13

Combination Ports

The two 10/100/1000 ports are combination ports. 
When an SFP module is inserted it has priority over 
the 10/100/1000 port of the same number. The 
corresponding 10/100/1000 port is disabled. The 
combination ports are numbered 25-26 on the 
Switch 3226 and 49-50 on the Switch 3250. 

Supported SFP Modules

3CSFP91 — SFP 1000BASE–SX

3CSFP92 — SFP 1000BASE–LX

3CSFP97 — SFP 1000BASE–LH70

Start-up Time

The unit will take approximately 2 minutes to 
become fully operational. The unit is fully 
operational when the Self Test LED is lit solid green

Autonegotiation of Port Speed and Duplex

All ports on the unit default to using autonegotiation 
to determine the correct speed and duplex setting. If 
the link partner also supports autonegotiation then 
this will result in the optimum link speed and duplex. 

The speed and duplex of the port may be manually 
set by using the 

physicalInterface ethernet 

portMode

 command to disable autonegotiation and 

select a fixed speed and duplex.

When autonegotiation is enabled, the unit asks for a 
fallback mode to be entered for use when the port 
connects to a non-autonegotiation device. This 
fallback mode parameter has been left in the CLI for 

compatibility with other 3Com devices but is ignored 
by this device.

When connected to a device that will not 
autonegotiate the device follows the algorithm 
required by the autonegotiation standard which 
states that ports must detect the link speed and then 
operate in half duplex mode. 

Auto-MDIX is not available if auto-negotiation is 
disabled on a port. That port will only operate in 
MDIX mode.

LACP Protocol

The LACP protocol is disabled by default. Some 
legacy devices do not support LACP and 3Com 
strongly recommends LACP remains disabled on 
ports connected to these devices (in rare cases, if 
LACP is enabled on ports connected to these 
devices, it can result in incorrect network 
configurations).

Web Interface

Many Web browsers can be configured to ignore 
stylesheets, substituting user configured fonts and 
font sizes. Ignoring stylesheets may cause 
unpredictable effects when accessing the Web 
interface. 3Com recommends that you enable 
stylesheets on browsers used to access the Web 
interface of the Switch.

 


background image

14

S

UPER

S

TACK

®

 3 S

WITCH

 3226 

AND

 S

WITCH

 3250 S

OFTWARE

 V

ERSION

 1.02 R

ELEASE

 N

OTES

Known Interoperability Issues

An incompatibility exists when changing link speed 
from 10 Mbps half duplex to 100 Mbps half 
duplex. If auto-negotiation on the Switch is 
disabled and the link speed on the Switch is 
changed from 10 Mbps half duplex to 100 Mbps 
half duplex, there is a possibility that the link 
partner will not detect the change. The link will 
have to be broken and reconnected before the link 
partner will detect the speed and change link 
speed to 100 Mbps half duplex.

When using LACP to form a trunk with a 
SuperStack 3 Switch 4400, ensure that the 
Switch 4400 is running the latest software release. 
Older versions of software occasionally fail to 
correctly form the trunk resulting in a network 
loop. Alternatively you could consider configuring 
the trunk manually.

3Com Network Supervisor

The CD-ROM contains 3Com Network Supervisor.

3Com Network Supervisor provides powerful yet 
easy-to-use network management. Focused on the 
needs of small to medium enterprises, it enables you 
to manage your network more efficiently. For larger 
networks (up to 2,500 nodes) and extra functionality 
you can purchase the 3Com Network Supervisor 
Advanced Package.

To download the latest 3Com Network Supervisor 
and Service Pack please visit:

http://www.3com.com/3ns/

After installation, click LiveUpdate to add support for 
the latest 3Com products.

For HP OpenView users the Switch 3226 and Switch 
3250 (and all other 3Com managed products) are 
fully supported by the 3Com Integration Kit for HP 
OpenView (3C15300).

Copyright © 2004, 3Com Corporation. All rights reserved.
Unless otherwise indicated, 3Com registered trademarks are registered in the 
United States and may or may not be registered in other countries.

3Com, SuperStack, and the 3Com logo are registered trademarks of 3Com 
Corporation. 

Windows is a registered trademark of Microsoft Corporation. Other brand and 
product names may be registered trademarks or trademarks of their respective 
holders.