USER MANUAL

Cleans and sanitizes

CPAP tubing

www.3BLumin.com


background image

2


background image

3

Indications for Use    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Specifications    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Understanding your Lumin cleaner   .  .  .  .  .  .  .  .  .  .  . 7

Using your Lumin BULLET   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

Maintenance of your Lumin BULLET  .  .  .  .  .  .  .  .  .  . 9

FAQ   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10


background image

4

Thank you for your recent purchase of the Lumin BULLET 

Hose Sanitizer. The BULLET was developed by 3B Medical, a 
manufacturer and distributor of CPAP devices and masks.

The Lumin BULLET device may be used with all brands of 

tubing, including heated hoses.

The Lumin BULLET disinfects using a very specialized and high 

powered UVC light source, the same type of light source used in 
hospital operating rooms and sterile clean rooms. UVC light will 
disinfect up to 99% of harmful bacteria, pathogens and fungi that 
can cause infection and illness. UV light is fast, safe and clean. 
There are no harmful chemicals.

The 3B Lumin and Lumin BULLET products are intended 

to supplement your CPAP accessory manufacturer’s cleaning 
recommendations.

Please read and follow all directions in this user manual. Any 

questions can be directed to

 support@3Bproducts .com .

Helpful Hint:

We recommend disinfecting 
CPAP hoses twice weekly, and 
daily during cold and flu season.


background image

5

Indications for Use

The Lumin BULLET is a device intended to disinfect 

Continuous Positive Airway Pressure (CPAP) hoses . A person 
using a PAP device to treat Obstructive Sleep Apnea (OSA) may 
use BULLET to sanitize their hose and heated tubing to augment 
their PAP equipment manufacturer’s recommended cleaning 
instructions. The Lumin BULLET is intended for home use. 

Warning - the Lumin BULLET is not a toy and is not 

intended to be used by children.
Warning - the Lumin BULLET has a powerful UV light LED 

included.
Warning - do not use in or around sinks, tubs, pools or any 

bodies of water.
Warning - This device uses powerful magnets, please 

exercise caution if you have an implanted medical device 

affected by magnets (pacemakers, internal defibrillators)
Warning - use this device only for its intended use as 

described in this manual. If the equipment is not used 

in the manner specified, the protection provided by the 

equipment may be impaired. 
Warning - Do not attempt to operate this device with 

the shell open. The device was designed to shut off 

automatically when the shell is open. It is important not to 

defeat or tamper with this safety feature as UVC light can 

cause damage to eyesight.


background image

6

SKU:  

LM4000

Weight:  

10.5 oz.

Dimensions:  

8.5” x 2.5” x 2.5”

Voltage: 

DC 5V  500mA

Power Rating: 

3W

Environmental Conditions:

      Storage Temperature: 0˚ to 120˚ F / -18˚ to 49˚ C

      Operating Temperature: 20˚ to 104˚ F / 7˚ to 40˚ C

      Humidity: Up to 93%, non-condensing

      Altitude: Up to 2000 M

SPECIFICATIONS

EXPLANATION OF SYMBOLS USED

Equipment protected throughout by double 
insulation or reinforced insulation

Refer to instruction manual

Important information concerning your safety or 
the operation of your device


background image

77

Understanding Your Lumin Cleaner

The Lumin BULLET operates using a specialized high powered 

germicidal UV LED. UV disinfection is effective on bacteria, viruses, 
mold and fungi and is well suited for keeping your CPAP tubing 
free from pathogens that can make you sick. CPAP hoses are 
in contact with warm moist air throughout the night, the ideal 
environment for breeding bacteria. Use of the Lumin BULLET will 
help keep you healthy and compliant with your CPAP equipment.

Because the Lumin BULLET operates using a form of high 

energy light, it is very effective in disinfecting your CPAP tubing. 
To keep your hose clean and reduce the risk of infections, we 
recommend using BULLET twice weekly on your hose. Maintain 
healthy breathing with quarterly replacement of your CPAP hose. 
3B’s Ultra Noir CPAP hose is available from your Lumin BULLET 
reseller or online at 3BLumin.com. 

EXPLANATION OF SYMBOLS USED


background image

8

Using your Lumin BULLET

1. Charge Lumin BULLET by plugging in USB cord to bottom of 

BULLET.

2. The BULLET will glow RED while charging, and GREEN when 

fully charged.

3. Remove BULLET and place inside CPAP tubing so there is 

enough tubing hanging over to pull the tubing.

4. Place BULLET in shell, you will feel the magnets grab the 

BULLET.

5. Close shell and slide clasp until the shell locks, your BULLET is 

now activated.

6. Pull the tubing all the way to the right, then back to the left, 

ensuring you cover the entire length of tubing twice, this process 
should take 30-60 seconds for optimal disinfection.

7. Remove hose from BULLET, it is now ready to use.


background image

9

Caring for your Lumin BULLET Device

Should the shell casing of your 3B Lumin BULLET become 

soiled you may wipe down with any moist cloth. Do not immerse 
your Lumin BULLET into water or any cleaning solvents. Place your 
BULLET on a level counter or tabletop. Do not drop your Lumin 
BULLET or damage may occur.


background image

10

Frequently Asked Questions

How does Lumin BULLET work?

Lumin works by emitting high energy light within a narrow spectrum 
referred to as UV-C. The Lumin relies on a lhigh powered germicidal 
UVC-LED designed to produce the highest amounts of UV energy – 
where 90% of energy is generated around 254nm. This light is very 
close to the peak of the germicidal effectiveness curve of 265nm, 
the most lethal wave to microorganisms. The dose of UV-C emitted 
in one 1 minute cycle is sufficient to kill most bacteria and mold on 
a surface. The use of UV-C is environmentally friendly, leaves no 
residue or toxic gases or chemicals. UV-C systems are currently in 
use to disinfect operating rooms, ambulances, emergency service 
vehicles and other high touch areas.

Why doesn’t the Lumin use Ozone, like other CPAP cleaners?

Because 3B Medical is a manufacturer of CPAP equipment, masks 
and accessories, we have a heightened level of commitment and 
concern for our patients. We did not feel that the safety concerns of 
ozone being used in the home were being adequately disclosed. Due 
to the lifestyles of many of our patients, we also had concerns that 
the two hour wait period in using CPAP equipment might be ignored 
and harmful OZONE inhaled. The U.S. EPA published a serious 
warning about use of ozone in a home environment:
“When inhaled, ozone can damage the lungs. Relatively low 

amounts can cause chest pain, coughing, shortness of breath 

and throat irritation. Ozone may also worsen chronic respiratory 

diseases such as asthma and compromise the ability of the body 

to fight respiratory infections.”

https://www.epa.gov/indoor-air-quality-iaq/ozone-generators-are-sold-air-cleaners

For that reason, in designing the Lumin BULLET, care was taken to 
find the safest and fastest way to disinfect CPAP accessories. UV-C 
was by far the best solution.


background image

11

WARRANTY

Your Lumin BULLET is warranted for a period of 1 years 

from time of purchase to be free from manufacturer defect or 
workmanship. Should you encounter a warranty issue please 
contact 3B Medical at www.3BLumin. com to submit a return 
authorization or email support@3bproducts.com.

It is at the discretion of 3B Medical to repair, replace or 

exchange your Lumin BULLET unit should it be necessary. 3B 
Medical is not liable for misuse, mishandling or breach of this 
written guarantee. Attempts to alter the Lumin in any way will 
void warranty.


background image

203 Avenue A NW Suite 300 • Winter Haven, FL 33881

www.3BLumin.com and www.3Bproducts.com

Technical Support contact 3BLumin.com/support

Sales and Information contact info@3BLumin.com

This product is not intended to diagnose, treat, cure or prevent any 
disease or medical condition. Remember to always consult a physician 
prior to using any medical device, the information provided herein is not 
to be construed as a medical diagnosis or medical advice. No medical 
claims are implied or intended with the sale of this device. Purchaser 
accepts responsibility for correct and proper use of device.

 For more information visit www.3BLumin.com

3B 0219 3765 LUMIN BULLET

5010494

This equipment has been tested and found to comply 
with the limits for a Consumer ISM equipment, 
pursuant to Part 18 of the FCC Rules. These limits 
are designed to provide reasonable protection against 
harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there 
is no guarantee that interference will not occur in a 
particular installation.”

Please note that changes or modifications of this 
product is not expressly approved by the party 
responsible for compliance could void the user’s 
authority to operate the equipment.

If this equipment does cause harmful interference to 
radio or television reception, which can be determined 
by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or 
more of the following measures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and 

receiver.

•  Connect the equipment into an outlet on a 

circuit different from that to which the receiver is 
connected.

•  Consult the dealer or an experienced radio/TV 

technician for help.

This product may cause interference to radio 
equipment and should not be installed near maritime 
safety communications equipment, ships at sea or 
other critical navigation or communications equipment 
operating between 0.45-30 MHz.

Lumin BULLET

Model No .: LM4000

This device complies with Part 18 of the FCC Rules.

Conforms to UL STD 61010-1,61010-2-040