2-Wire Intercom System

Read this manual carefully before using the product, and keep safe for future use.

CDV17DS INSTALLATION MANUAL(EN)

 


background image

Unit Mounting

The location of outdoor station should keep away from snow,rain,and intensity light.

Accessory contents:

Accessories include a screwdriver T20, one M4X10 screw,  two PA4X25 screws,three PA3x25 

screws,three PM3x12 screws,and five screw stoppers Φ6X30.

Installation steps:

Installation height for door station usually is 145~160cm.

1. Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly.

2. Attach the front panel to the back panel, then use the screw to fix it.

Wiring and Connection

Basic one-to-one connection

1

2
3

4

7

5
6

M4*10

PM3*12

1

2

3

-

+

Monitor

Bus   PL S2+ S1+ S1-

BUS(Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

AC~

PC6

1 2 3

ON

1  2  3

1 2 3

ON

1  2  3

BUS(Blue&Green)

S2+(Red)

PL(White)
S1+(Yellow)

S1-(Black)

4P

terminal

DIP

PROG

SPK adjust

Lock Control

Jumper

CALL button

please refer to DT-CAM user instructions in details.

PL(White): external lock power input, connect to the power positive(power +).

S1+(Yellow): lock power(+) output.

S1-(Black): lock power(-) output.

Parts and Function

Speaker

Unlock Indicator

Talk Indicator

Front Panel

Call Button

Microphone

1

2

3

4

5

6

Terminal Description

The audio door station is designed for the CDV 2Easy 2-wire system. The 17-D is made of 
zinc alloy for protection against vandalism including the call button  featuring  a  blue  
backlight  for  auxiliary  illumination.  The  door  unlock and speech LED indicator show 
visual verification of operation. The rain cover provides  protection adverse weather.

Connection Cable

 BUS(Blue&Green): connect to the bus line, no polarity.
 S2+(Red): the S2+ connect with S1- to activate the relay of ERL to extend a  camera
                 of DT-CAM, please refer to DT-CAM user instructions in details. 

◆ 

Lock Control Jumper:

 For selection of lock type. Please refer to Electric Lock Connection: Pg7.

◆ 

DIP switch:

 

to set ID code for door station, total 4 door stations can be supported. Please refer to    

    DIP Switch Settings.

◆ 

SPK adjust:

 to adjust the talk volume.

◆ 

PROG button:

 reserved.

◆ 

CALL button:

 

press to call the user.

◆ 

4P terminal:

 to update software via specified programmer.

◆ 

Connection cable:

 to connect the bus line and the electronic locks.

7

Rain Cover

-1-

 


background image

Parts and Function

The door station is an audio door station without camera,which is designed for DT 2-wire system.
The front panel is made of zinc alloy for better protection against vandalism & cauterization, and 
the call button is also made of zinc alloy with blue backlight for auxiliary illumination, the unlock 
and talking LED indicator guarantee the door station working efficiently.
With the rainy cover, the door station can be strongly protection against water. 

Terminal Description

Speaker

Talk Indicator

Unlock Indicator

Call Button

Front Panel

Microphone

1

2
3

4

7

5
6

1

2

3

4

5

6

Rainy Cover

7

M4*10

PM3*12

1

2

3

-

+

Bus   PL S2+ S1+ S1-

AC~

PC6

1 2 3

ON

1  2  3

1 2 3

ON

1  2  3

BUS(Blue&Green)

S2+(Red)

PL(White)
S1+(Yellow)

S1-(Black)

4P

terminal

DIP

PROG

SPK adjust

Lock Control

Jumper

Connection line

CALL button

PL(White): external lock power input, connect to the power  positive(power +).
S1+(Yellow): lock power(+) output.
S1-(Black): lock power(-) output.

Unit Mounting

Wiring and Connection

Basic one-to-one connecton

BUS(Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

The location of outdoor station should kept away from direct snow, rain and intense light.
Accessory contents:
Accessories include a screwdriver T20, one M4x10 screw,  two PA4x25 screws, three PA3x25 
screws, three PM3x12 screws  and five screw stoppers  6x30.
Installation steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rain cover to the wall, connect the cable correctly.

2. Attach the front panel to the back panel, then use the screw to fix it.

Audio 

Handset

-2-

 


background image

With DBC-4S  Wiring Mode

1 2

3

ON

1 2

3

ON

1 2

3

ON

1 2

3

ON

1# Camera

DIP=on,off,off

ID=00

ID=10

ID=01

ID=11

2# Camera

3# Camera

4# Camera

DBC-4S

A  B  C  D

OFF

ON

Impedance 

Switch

Bus   PL S2+ S1+ S1-

Bus   PL S2+ S1+ S1-

Bus   PL S2+ S1+ S1-

Bus   PL S2+ S1+ S1-

1 2

3

ON

ID=00

Code=0, DIP-6=off

1 2

3 4 5 6

ON

Code=1, DIP-6=off

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=3, DIP-6=on

Code=1, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=2, DIP-6=on

Code=0, DIP-6=on

Code=15, DIP-6=on

Code=13, DIP-6=on

Code=14, DIP-6=on

Code=12, DIP-6=on

OFF ON

OFF ON

monitor

monitor

monitor

monitor

monitor

monitor

monitor

monitor

DBC-4S

A  B  C  D

DBC-4S

A  B  C  D

Impedance 

switch

Impedance 

switch

DIP=on,off,off

DIP=on,off,off

1 2

3

ON

ID=00

AC~

PC6

AC~

PC6

AC~

PC6

Code=14, DIP-6=off

1 2

3 4 5 6

ON

Code=15, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Mult Door Staton Connecton

BUS(Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

Multi Monitors Connection Basic 

IN-OUT wiring mode

Audio Handset

Audio Handset

Audio Handset

Audio Handset

Audio Handset

-3-

 


background image

Multi Door Station Connection

Multi Monitors Connection
Basic IN-OUT wiring mode

Monitors

1 2

3

ON

1 2

3

ON

1 2

3

ON

1 2

3

ON

1# Camera

DIP=on,off,off

ID=00

ID=10

ID=01

ID=11

2# Camera

3# Camera

4# Camera

DBC-4S

A  B  C  D

OFF

ON

Impedance 

Switch

Bus   PL S2+ S1+ S1-

Bus   PL S2+ S1+ S1-

Bus   PL S2+ S1+ S1-

Bus   PL S2+ S1+ S1-

BUS(Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

1 2

3

ON

ID=00

monitor

monitor

monitor

monitor

Code=0, DIP-6=off

1 2

3 4 5 6

ON

Code=1, DIP-6=off

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=3, DIP-6=on

Code=1, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

Code=2, DIP-6=on

Code=0, DIP-6=on

Code=15, DIP-6=on

Code=13, DIP-6=on

Code=14, DIP-6=on

Code=12, DIP-6=on

OFF ON

OFF ON

DBC-4S

A  B  C  D

DBC-4S

A  B  C  D

Impedance 

switch

Impedance 

switch

DIP=on,off,off

DIP=on,off,off

1 2

3

ON

ID=00

AC~

PC6

AC~

PC6

AC~

PC6

Code=14, DIP-6=off

1 2

3 4 5 6

ON

Code=15, DIP-6=on

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

1 2

3 4 5 6

ON

With DBC-4S  Wiring Mode

Audio 

Handset

Audio 

Handset

Audio

Handset

Audio 

Handset

Audio

Handset

Audio
Handset

Audio 

Handset

Audio 

Handset

-4-

 


background image

Door Lock Controlled with Dry Contact

EB

*

LOCK

Jumper position in 

Connect one lock

2-3

Bus      PL  S2+  S1+  S1-

DIP Switch Setting

The DIP switch is designed to set the code for door station and monitor, there are two states for 
each DIP switch, please refer to the following sketch map.

Door station DIP setting

Indoor monitor DIP setting

Bit state

Description

ON(1)

=

OFF(0)

=

ON

ON

Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is 

used to match the video impedance.The switches can be modified either before or after installation.

There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.

Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance, 

otherwise set to OFF. 

Bit-1~Bit-5 are used to set user code, to DT595A door station, the user code should set to 0~15.

Please refer to the following settings:

Note: if the video impedance need to match, please set the bit-3 on.

1 2

3

ON

1 2

3

ON

1 2

3

ON

1 2

3

ON

ID = 0(00), set to the first door station

ID = 1(10), set to the second door station

ID = 2(01), set to the third door station

ID = 3(11), set to the fourth door station

LOCK

Take off the Jumper

POWER 

SUPPLY

Bus      PL   S2+  S1+  S1-

1 2 3

AC~

PC6

ERL

DT595A

DT-CAM

DS

IM

  Bus   PL S2+ S1+ S1-

OUT IN

With DT-CAM wiring mode - NOT UK

The audio door station DT595A can be extended an additional CCTV camera to be a 
video door station. For more details about the camera, please refer to DT-CAM user 
instructions. 

Note:
1. Electronic lock of Power-on-to-unlock (fail 
    secure) type should be used. 
2. The door lock is limited to 12V, and holding 
    current must be less than 250mA.
3. The door lock control is not timed from Exit 
    Button(EB).
4. The Unlock Mode Parameter of Monitor must

    be set to 0 (by default).

Note:
1. An external power supply must be used 
    depending on they type of lock used.
2. The jumper must be taken off before              
    connecting a lock
3. Set the Unlock Mode of the Monitor for            
    different lock types.
*  Power-on-to-unlock type: Unlock Mode=0 (by  
    default) * Power-off-to-unlock type: Unlock     
    Mode=1

Audio 

Handset

Electric Lock Connecton

Door Lock Controlled with Internal Power

-5-

 


background image

 

 

 

 

Use the DIP switch and PROG button to change the unlock setting. 

 
 

1. Set DIP‐1=ON, DIP‐2=OFF; 
2. Press the PROG (Fig 1) button and hold for 3 secs (blue LED on) to activate the setup option: 

1) NO relay: press the PROG button one more time. 
2) NC relay: press the PROG button and hold for 3s again. 

 

 

1. Set DIP‐1=OFF, DIP‐2=ON; 
2.  Press the PROG (fig 1) button and hold for 3 secs (blue LED on) to activate the setup option: 
3.  Press  the  PROG (fig 1)  button  and  hold  for  the  number  of  seconds  req uired (indicted by beeps and 
red LED).  The  time between pressing and releasing the PRGO button is the unlock time. 

 

 

Note:  DIP‐1  and  DIP‐2  should  reset  to  the  corresponding  ad dress code  after setting the above. 

 
 
 

   Fig. 1 

 
 
 
 
 

1 2 3

Prog Button

CDV17DS PCB

 

Instructions for Lock Relay 1 Setting: 

UNLOCK TYPE 

UNLOCK TIME 

-6-

 


background image

With DT-CAM wiring mode

Electric Lock Connection

Door Lock Controlled with Internal Power

Door Lock Controlled with Dry Contact

EB

*

LOCK

Jumper position in 

Connect one lock

2-3

Bus      PL  S2+  S1+  S1-

DIP Switch Setting

Bit state

Description

ON(1)

=

OFF(0)

=

ON

ON

1 2

3

ON

1 2

3

ON

1 2

3

ON

1 2

3

ON

ID = 0(00), set to the first door station

ID = 1(10), set to the second door station

ID = 2(01), set to the third door station

ID = 3(11), set to the fourth door station

LOCK

Take off the Jumper

POWER 

SUPPLY

Bus      PL   S2+  S1+  S1-

1 2 3

AC~

PC6

ERL

DT595A

DT-CAM

DS

IM

  Bus   PL S2+ S1+ S1-

OUT IN

Monitor

Door station DIP setting

The DIP switch is designed to set the code the for door station and the monitor, there 
are two states for each DIP switch, please refer to the following:

Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door 
station, bit-3 is used to match the video impedance.The switches can be modified either 
before or after installation.

Note: for video impedance EOL: set the bit-3 on.

Indoor monitor DIP setting

There are 6 bits in total. The DIP switches are used to configure the user address for Monitors.

Note:

1. The external power supply must be used 

    according to the lock.

2. The jumper must be taken off before connecting.

3. Setup the Unlock Mode of Monitor for different 

    lock types.

* Power-on-to-unlock type:Unlock Mode=0 (by default)

* Power-off-to-unlock type:Unlock Mode=1

-7-

Bit-6 is an video impedance EOL switch,  set to ON to match the impedance.
Bit-1~Bit-5 are used to set user address, the user code should set be set to 
0~15. Please refer to the following settings:

 


background image

When Monitor quantity < 20

When Monitor quantity >20

Bit state

User code

code=0

code=1

code=2

code=3

code=4

code=6

code=7

code=8

code=9

code=10

code=11

code=12

code=13

code=14

code=15

code=5

Bit state

User code

Bit state

User code

Cable Requirements

The maximum distance of the wiring is limited in the DT system. Using different cables may also 
affect the maximum distance which the system can reach. 

Cable Usage

A

B

C

Twisted cable 2x0.75 mm

2

60

60

30

80

80

40

Twisted cable 2x1 mm

2

Cable Usage

A

B

C

Twisted cable 2x1 mm

2

70

30

20

70

50

30

Twisted cable 2x1.5 mm

2

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

The farest monitor

B

A

C

DBC-4S

monitor

monitor

monitor

with two or four monitors

AC~

PC6

Note:If the monitor has been specified 

the distance,refer to the parameter.

Specification

Precautions

•   Power Supply:DC 24V
•   Power Consumption:Standby 60mA; Working status 200mA
•   Lock Power Supply:12Vdc, 300mA(Internal Power)
•   Working Temperature: -10ºC ~ +45ºC
•   Wiring: 2 wires,non-polarity
•   Dimension:137(H)x49(W)x28(D)mm

•  Please clean the unit with soft cotton cloth, do not use a chemical cleaning agent. If  
    necessary, please     use a little pure water or dilute soap water to clean the dust.
•  The unit is weather resistant. However do not spray high pressure water on access    
    control keypad directly. Excessive moisture may cause problems with the unit.
•  You must use the right adaptor which is supplied by the manufacture or approved by
    the manufacturer.
•  Pay attention to high voltage inside the products, please refer service only to a          
   trained and qualified professional.

-8-

 


background image

When Monitor quantity < 20

When Monitor quantity >20

Bit state

User code

code=0

code=1

code=2

code=3

code=4

code=6

code=7

code=8

code=9

code=10

code=11

code=12

code=13

code=14

code=15

code=5

Bit state

User code

Bit state

User code

Specification

•   Power Supply:DC 24V

•   Power Consumption:Standby 60mA; Working status 200mA

•   Lock Power Supply:12Vdc, 300mA(Internal Power)

•   Working Temperature: -10ºC ~ +45ºC

•   Wiring: 2 wires,non-polarity

•   Dimension:137(H)x49(W)x28(D)mm

Precaustions

•  Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. 

If necessary, please use a little pure water or dilute soap water to clean the dust.

•  The unit is weather resistant. However do not spray high pressure water on access control keypad 

directly. Excessive moisture may cause problems with the unit.

•  You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.

•  Pay attention to the high voltage inside the products, please refer service only to a trained and qualified 

professional.

Cable Usage

A

B

C

Twisted cable 2x0.75 mm

2

60

60

30

80

80

40

Twisted cable 2x1 mm

2

Cable Usage

A

B

C

Twisted cable 2x1 mm

2

70

30

20

70

50

30

Twisted cable 2x1.5 mm

2

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

1 2

3 4 5

6

ON

B

A

C

DBC-4S

AC~

PC6

Cable Requirements

The maximum wiring distance is limited in the 2Easy system. Using different 
cables can also affect the maximum distance achievable. 

The furthest monitor

with two to four monitors

Note: If the monitor has been specified 

the distance, refer to the parameter.

Audio 

Handset

Audio 

Handset

Audio 

Handset

-9-

 


background image

 


background image

Printed  2012. 09

. Right to interpret and copyright of this manual are preserved.

The design and specifications can be changed without notice to the user. Right to 

interpret and copyright of this manual are preserved.

DT-ENG-595A-V1   P120924