2HEAT MRF Series User Manual

RF Series WW Series

Made by: 2HEAT
Type: User Manual
Category: Thermostat
Pages: 11
Size: 0.15 MB

 

Download PDF User Manual


Related Product Video

 

Full Text Searchable PDF User Manual



background image

Users Manual

Thank you very much for choosing our
product and services as well as your trust
and support to us

 


background image

Preface

>1

This product has the following characteristics:

Conformity with Standard

Conformity with the European Decree

1. Easy operation: One function knob and three push buttons
2. Weekly
3. Two kinds of program selections with permanent memory: Ex-work preset program and

program set by the customers themselves

4. Large screen LCD display
5. Adjustable selection of comfort temperature, economic temperature and antifreeze

temperature

6. Advanced radio transmission technology: Wall penetration transmission distance in the

room 60m(for RF/MRF model);

7. Suitable for the control and energy saving of wall mounted boilers, condensation boilers

and individual household measuring heating system;

8. It can realize the function of one receiver controlling many sub-devices and many rooms

at the same time;

9. Only need 2 Size AA 1.5V batteries for power supply
10. Celsius degree or Fahrenheit degree display
11. Fast and simple installation.
12. The displayed temperature can be calibrated.

EN 60730-1 standard and its revision
EN 60730-2-7 standard
EN 60730-2-9 standard

B. T. 73/23/EEC
E. M. c. 89/336/EEC and Amendments 93/68/EEC

programmable function control

WW/RF/MRF (with-wire /radio frequency / multi-channel RF) series are room

thermostats with 7 days programmable function. This system can completely control the
boiler or heating system according to the program preset when out of the factory or set by
the customers themselves. The controller with electricity supplied by the batteries can
be put any where in the ordinary room, which makes the work and life of the installers and
the customers become more simple and comfortable. F o r RF model

,

the receiver of

this device is connected directly with the hang boiler or the other heating systems. The
transmitter adopts special radio signal and receiver communication with characteristics of
strong wall penetration, stable communication, no interference and low electric
consumption. The MRF model can control inde pendently different tem perature in
the maximum 4 rooms by the multi-channel RF. The damager of radialization to the body is
lower than using the radiogram or TV set.

 


background image

>2

Display screen symbols

A
B
C
D
E
F
G
H
I=
J
K
L
Q
N
O
P
M

= Present ambient temperature

= Comfort temperature

= Economic temperature
= Freeze-proofing temperature

= Present time

= Working state

= 7days display in a week, and the present day display is in the square frame.
= Running symbol of the equipment

Program conditions

= Battery conditions

=

=

= Celsius degree or the Fahrenheit degree

=

"increasing" key

=

"confirmation" key

=

"decreasing" key

= Function change-over switch, totally 7 modes(three application modes, three

setting modes, one off mode)

Automatic operation mode

Manual operation mode

Antifreeze mode

Program setting mode

Temperature setting mode

Date/time setting mode
Power switch off mode

fig.1

[fig.1]

 


background image

>3

Product Specifications

Power supply: Two LR6 type1.5v alkaline batteries, service life more than one year.
Temperature adjustment range: 4

35

Ambient temperature displayed on the screen: 0

40

Temperature test frequency: once/min.
Display accuracy

0.5

Probe

NTC 3%

Protection degree

IP20

Thermal gradient

1K/3min

Output

Switch relay

Load on contacts

16 A/250V(RF); 5A/250V(MRF); 2A/125V(WW)

Insulation conditions: Normal environment
Max. operating temperature

50

Storage temperature

0

60

Frequency

433 MHz(for RF/MRF model)

Programming

Weekly

Software class

A

LCD display
Minimum programming interval: 1 hour
Installation

Wall mounted

Radio transmission distance

Indoor 16/50m

outdoor 100/300m(for RF/MRF model)

÷

÷

: ℃

: ÷

Application

1.

"Automatic" mode

.

The preset ex-work system program can also be changed in the "Program setting". The
running time program is displayed in the "Program display area"

, and in the working

conditions display, the factory preset program that has not been modified by the customer is
displayed as

. The automatic program that has been modified by the customer will

display

and

symbols in order to distinguish from the Ex-work preset program. In

each time period, the executive "Comfortable temperature"

(The preliminary value is

20

), economic temperature

(The preliminary value is 18

) and the antifreeze

temperature

(The preliminary value is 5

) are set in the temperature setting

. After

the function change-over switch is switched to "Turn off the power." the program is still
retained, and after the batteries are taken out, the personally set program and the ex-work
preset program do not lose.

 


background image

>4

Application...

Program presetting when out of factory:

From Monday to Friday

Saturday and Sunday

00:00-----06:00 Economic temperature

06:00-----08:00 Comfort temperature

08:00-----18:00 Antifreeze temperature;

18:00-----22:00 Comfort temperature

22:00-----24:00 Economic temperature

00:00-----06:00 Economic temperature; 06:00-----22:00 Comfort temperature

22:00-----24:00 Economic temperature

2

"Manual" mode

Note:

3

"Antifreeze" mode

The chronothermostat controls the temperature at a constant temperature mode, and the

default temperature is 20

. The temperature can be adjusted with

key or

key

and the temperature display flashes at this time. The screen will recover to display the room

actual temperature when there is no further adjustment within 5 seconds.

When moving the function change-over switch position every time and when

resetting the manual temperature is needed, the system will automatically start to set from

the manual mode that was set last time, and the state display circular at the right lower

corner will completely display double frames.

The chronothermostat only controls the system to be operated at the state of preventing the

ambient temperature from dropping below the antifreeze temperature to have been set in

order to make the equipment and pipes free from freezing. This temperature is set in the

mode of "Temperature setting", and the default valve is 5

.

 


background image

1.

Setting of date and time: Set present date (which weekday), hour and minute.

A. Set the function change-over switch to

position, the screen mode display area will

display hour

icon.

B. When the frame displaying the present date starts flashing, press

key or

key to

adjust the present weekday, and press

key to confirm, and then turn to next setting

C. Then

the number representing the hour flashes, press

key or

key to adjust the

present hour, and press

key to confirm, and then turn to next setting

D. Then

the number representing the minute flashes, press

key or

key to adjust the

present minute, and press

key to confirm, and then turn to next setting

E. Return to the first setting step;

F. Finish the time setting

Adjust the function change-over switch to the operation mode

("Auto", "Manual", "Antifreeze"), to start the operation or carry out other settings.

>5

Setting

2.

Temperature setting

Set the comfort temperature, economic temperature and

antifreeze temperature.

℃,

: ℃

℃,

℃,

The setting scope of the antifreeze temperature is

4-10

the preliminary antifreeze

temperature value is

5

The setting scope of the economic temperature is

5-30

the preliminary economic

temperature value is

18

The setting scope of the comfort temperature is

10-35

the preliminary comfort

temperature value is : 20

A. Set the function change-over switch to

position

The screen working appearance

column shows the temperature icon

.

B. The left of the temperature number shows the comfort temperature icon

and the

temperature number flashes at the same time. Press

key or

key to adjust the

comfort temperature value

press

key to confirm and then move to next setting

C. Next

the icon representing the economic temperature

and the temperature number

flashes at the same time. Press

key or

key to adjust the economic temperature

value

press

key to confirm and then move to next setting

D. Next

the icon representing the antifreeze temperature

, and the temperature number

flashes at the same time. Press

key or

key to adjust the antifreeze temperature

value, press

key to confirm and then move to next setting

E. Return to the first setting step

F. Finish the temperature setting

the same as the F Clause in "Setting of date and time".

 


background image

>6

3

Setting of self-established program

Set 7-days self-established program as well

as the control temperature for each period.

Copy the program for one day

A. Set the function change-over switch to

position

and screen appearance display area

shows the program setting icon

.

B. The icon and number showing the weekday flash, and press

key or

key to adjust

the date numerical value, press

key to confirm and then move to next setting

C. At this time

the cursor from zero point to 1 and the original temperature setting mode

( the temperature mode icon on the left of the temperature number ) begin to flash, press

key or

key to select the temperature

press

key to confirm

and then the

temperature mode display for this one hour period will be changed into the selected
temperature mode (Double solid frame for the comfortable temperature, single solid
frame plus single hollow frame for the economic temperature, double hollow frame for
the antifreeze temperature), and move to set next one hour temperature

D. Repeat the steps above until complete to set all temperature modes in 24 hours, then

return to the date selection mode, and keep pressing

key for a long time at the

program setting mode for every hour can quit from the temperature setting for the
rest time period. Enter into the date selection mode directly again, the rest unset part of
temperature will remain as the original default temperature or the temperature set before;

E. When the date cursor starts flashing again, it enters a new setting cycle for some day
F. Finish the temperature setting, the same as the F Clause in "Setting of date and time"

The modified time/temp erature program will be remembered as the customer's
self-established program. When the function change-over switch returns to AUTO, the
controller operates the customer's self-established program and

and

program

symbols will be displayed at the working mode display area in order to distinguish from
the ex-work preset program.

After entering a day program you can copy this into another day to save time when

creating a weekly program: For example, if you want to copy the program of Monday to
Thursday, the methods are as follows:
A. Select the program for Monday: With the selector on "AUTO PROG", press

key or

key

The outer frame for Monday flashes

to select Monday

and press

key

for 3 seconds until the

word appears on the screen

B. Copy to Thursday: While pressing

key constantly, press

key or

key at the

same time

and select to Thursday, then release

key or

key

then release

key

to finish the copying

and the

word disappears

At this time

the Thursday

cursor flashes

the setting of the day can be continued through

or

key as well as

the

.

C. Copying for other days, please repeat from the Step A to B.

Setting...

 


background image

>7

Setting...

4. Temporary temperature change:

At

"Automatic" mode

it can temporarily change the temperature at a given program period.

You have set the program already

the comfort temperature is 20

between 9:00~

18:00, but you want to lower the temperature to 18

at 10:00

then you set the temperature to

18

. This setting will not exist forever, it will remain until 18:00 when the program period is ended.

At

"Automatic" mode

set the required temperature directly through

key or

key, the

number representing the temperature will flash, and your adjusted temperature will be displayed
without further adjustment in 5 econds after the adjustment. The number representing the
temperature will stop flashing and continuously to display the present room temperature.
The automatic chronothermostat will recover to automatic mode at the following program
temperature changes.

Moving the function change-over switch can cancel the temporary temperature change

setting.

A. At

mode, keep

pressing

key for 5 seconds, then: the

symbol will be

displayed at the working state display area, and the temperature controller will take out the ex-
work preset program as the automatic control program.

B. Keep pressing

key long for 5 seconds again, the temperature controller will return to the

personal set program mode. At this time

and

program symbols will be displayed at

the working mode display area.

C. These two kinds of program modes can be alternated.

When inserting or taking out of 4V external DC power supply, it will not influence the mode,
operation and memory of the chronothermostat.

Adjustment and calibration of the temperature: When the SET key is at the antifreeze mode, keep
pressing

key for 3 seconds

the LCD screen will reveal

symbol. While pressing

key at the same time, press

or

key each time the original tested value will be rectified by

+0.5 degree or -0.5 degree. After releasing

key

the word

disappears. The maximum

adjusted and calibrated temperature is

3

.

For RF model: Press the learning button in receiver once, then the indicator light will flash.

Turn the change-over switch of sender to OFF position to turn off the LCD, press

key and

key at the same time. The match is finished when the indicator light put out.

For MRF model: Press the leaning button in receiver one time (the indicator light flash one

time in every 0.5 sec) to match the No.1 of transmitter. The method of matching in sender is the
same with the single RF.
Press the leaning button in receiver two times (the indicator light flash two times in every 0.5 sec) to
match the No.2 of transmitter. Press three times (the indicator light flash three times in every 0.5
secretary) to match the No.3. Press the button four times (light flash four times) to match the No.4.

± ℃

For example:

Note

5. Interchanging and application of Ex-work preset program and personal setting program;

6. External power supply

7. Adjustment and calibration of the temperature

8. Code matching

 


background image

1. The internal temperature controller should be installed away from the direct sunlight or

the position directly influenced by other cold and heat sources. The installation height
should be approximately 1.5 m off the floor.

2. Only the professionals can open the receiver box of the chronothermostat. to use 220V

power supply. The power supply wire must be guaranteed to be in the good insulation
during installation.

3. When installing the receiver box, the baseboard must be installed first and after

connecting the power supply and signal wire well, then put up the cover and fix it. The
chronothermostat manual cannot be used for repairing the product

and the user cannot

open the internal circuit board pers onally except for installation or disassembling the
batteries.

4. When you turn the switch to OFF position, you can set the state of the system controlled

after turning off the thermostat. Such as: Opened(AUTO +OF); Closed(AUTO +ON)

Antifreeze Model(

+PF). Operation

Press OK key until display ON

OF

PF under

the closed state, and the user can adjust

key or

key to change state. Then release OK

key.

(ON: Colse; OF:Open; PF : Antifreeze)

5. User can set the time when to turn on/off the system by the temperature difference

between opening and closing when reaching the setting temperature. Operation: press OK
key until display ADJUST under Manual mode, and set temperature difference by

or

key, Then release OK key. (Range: 0.5

3

, Regulation step: 0.5

, Default:1.5

.)

6. For four channel mode(fig 7), The CH5 isn't need to match any code, as long as the any

one of four channel is connected, the CH5 will be connected. But the CH5 is disconnected
just when all the four channel are disconnected.

℃~ ℃

>8

Attention for Installation

1

To control the Boiler shown in fig.4, fig.5.

2

To control the pump or the other heating system shown in fig.6, fig.7.

= phase (power supply 230)

= Neutral

= shared terminal

learning indicator light, will light one time when it receive

the signals from Emitter.

Learning button

Before you connect the Receiver, ensure that the power voltage of the SYSTEM to be
controlled ( boiler, pump, etc.) IS NOT CONNECTED and that it corresponds to the value
indicated on the base of the instrument (250

max).


WIRING
L

N

1

The light in Receiver =

The button in Receiver =
SAFETY PRECAUTIONS

U

2

= Pump, electric 3-way valve ,etc.

= normally open terminal

Installation Examples

 


background image

>9

Installation Examples

12 3

19

8 3.5

60

fig.2

fig.3

fig.4: RF model

fig.5: WW m odel

AC 220 ~

2

1

3

1

2

L

N

L

N

AC 220~

 


background image

>10

Installation Examples

fig.6: RF model

fig.7: MRF model

AC 220~

U

AC 220~

U1 U2 U3 U4

1

2

L

N

L

N

AC 220~

U