Warning  

• 

Do not connect or disconnect the Lambda Sensor while MegaSpartan is powered, only do so when MegaSpartan is unpowered. 

• 

The Lambda Sensor gets very hot during normal operation, be careful when handling it. 

• 

While the Lambda Sensor is in an active exhaust stream it must be controlled by MegaSpartan. Carbon from an active exhaust can 
easily build up on an unpowered sensor and ruin it. 

• 

Lambda sensor life when used with leaded fuels is between 100-500 hrs. The higher the metal content the shorter the life of the 
Lambda sensor. 

 

MegaSpartan Installation 

 
 
 

 

 
 
 
 
 

 

Lambda 1 

Lambda 2  Lambda 3  Lambda 4 

Lambda 5 

Lambda 6  Lambda 7 

Lambda 8 

Screw 

Terminal 


background image

 

 

MegaSpartan User Manual, Release Date: Aug 22 2018 

 

 

 

 

Screw 

Terminal # 

Name 

Connects to 

Note 

PowerA 

12v 

Use 15A fuse 

PowerB 

12v 

Use 15A fuse 

GroundA 

Ground 

Can connect all grounds to same point 

GroundB 

Ground 

Can connect all grounds to same point 

GroundC 

Ground 

Can connect all grounds to same point 

CANH 

MegaSquirt CAN Bus 

High 

 

CANL 

MegaSquirt CAN Bus 

Low 

 

Pressure sensor 

input 

Pressure Sensor 

Output 

 

5[V] output 

 

Provides 5[V] power to pressure sensor 

10 

12[V] protected 

output 

 

Not currently used. This terminal is protected by; fuse, diode (reverse 

polarity protection), and Transient Voltage Suppressor. 

 

For PowerA and PowerB each should be connected through the supplied fuse holders and 15A fuses. The best place to tap power is generally 
after the ignition switch or any other source of power that is always “live” when the engine is running. If the Lambda sensor is in an active 
exhaust stream and unpowered, carbon from an active exhaust can easily build up on an unpowered sensor and ruin it. 

You can ground all the grounds to the same point. 

 

Lambda Sensor Installation 

The Lambda Sensor should be installed between the 10 o’clock and the 2 o’clock position, 
less than 60 degrees from vertical, this will allow gravity to remove water condensation 
from the sensor. 
 

For all Oxygen sensor installations the sensor must be installed before the catalytic converter.  

 
 
 
For normally aspirated engines the sensor should be installed about 2ft from the engine exhaust port. For Turbocharged engines the sensor 
should be installed about 3ft from the engine exhaust port after the turbocharger. For Supercharged engines the sensor should be installed 3ft 
from the engine exhaust port

 

 

10 


background image

 

 

MegaSpartan User Manual, Release Date: Aug 22 2018 

 

 

 

TunerStudio Configuration for MegaSquirt 2 

 

In TunerStudio under “Basic Setup” select “EGO Control”.

 

 

For MegaSpartan with single Lambda, set “EGO Sensor Type” to “Single Wide Band”, set “1

st

 EGO sensor port” to “Remote ADC0”. “Burn” the 

settings to your MegaSquirt. 

 

 
 
 
 


background image

 

 

MegaSpartan User Manual, Release Date: Aug 22 2018 

 

 
 

 
 
 
 
For MegaSpartan with dual Lambda, set “EGO Sensor Type” to “Dual Wide Band”, set “1

st

 EGO 

sensor port” to “Remote ADC0”, set “2

nd

 EGO sensor port” to “Remote ADC1”. Burn the settings 

to your MegaSquirt. 

 

 

Under “Tools” select “Calibrate AFR Table” 

 

 

Set “EGO Sensor” to “Innovate LC-1/LC-2 Default”. “Write to Controller” your settings. 

 

 
 
 
 


background image

 

 

MegaSpartan User Manual, Release Date: Aug 22 2018 

 

 

TunerStudio Configuration for MegaSquirt 3 

 

In TunerStudio under “Fuel Settings” select “AFR/EGO Control”

 

 

Set “EGO Sensor Type” to “Wide Band”. Set “Number of Sensors” to 
appropriate number of Lambda sensors.  
 
For each Lambda sensor, set the “EGO X Port” to “CAN EGO”.  
 
Set “MS3X Inj A” to “MS3X Inj H” to the appropriate EGO#. EGO1 is 
MegaSpartan Lambda 1 … EGO8 is MegaSpartan Lambda 8. For example, if 
you set “MS3X Inj A” to “EGO1” then MegaSquirt will assign MegaSpartan 
Lambda 1 to Injector A. 
 
“Burn” settings to your MegaSquirt. 

 

 

 
 
 
 
 
 


background image

 

 

MegaSpartan User Manual, Release Date: Aug 22 2018 

 

Hardware DIP Switches 

 

Opening up the MegaSpartan case will reveal a set of DIP switches. 

Position 

PCB Name 

Default 

About 

CA0 

Off 

Bit 0 of CAN Address 

CA1 

On 

Bit 1 of CAN Address 

CA2 

Off 

Bit 2 of CAN Address 

CA3 

On 

Bit 3 of CAN Address 

CR 

On 

CAN Bus Resistor between CANH and CANL 

Boot 

Off 

Triggers Bootloader 

 

Warranty 

14Point7 warrants this product to be free from defects for 2 years. Sensors if purchased from 14Point7 carry no warranty whatsoever. 
Warranty does not cover user error and abuse.  

 

Disclaimer 