Camera Housing – Model 5 D Mark II    (Canon)

   

 

User Manual

 

   

                     

Contents:       

                    1. Introduction   

                     

                    2. Specifications   
                     
                    3. Function Controls   
                     
                    4. Set up Instructions   
                     
                    5. Use & Care of Housing   
                     
                    6. Service   
                     
                    7. Warranty 
                     
                     
                     

 
 
 

 

1. Introduction

   

 

10 BAR Underwater Housings are small,  light and rugged enough to be used on every dive. Use of a clear 
polycarbonate  allows  for  visual  inspection of camera condition  and  the  O-ring seal.  10  BAR  Housings  are 
designed  for the ever  -increasing  variety  of  models of  digital still and  video cameras.  Advanced  computer 
aided  design  and  CNC  manufacturing  technologies  ensure  precise  dimensions.  Each  housing  body  is  first 
injection  molded,  and  then  machined  to  configure  to  individual  camera  model.  A  range  of  lens  ports  and 
controls are fitted, to tailor the housing to your camera model. 

 

 

 

 

 

 

 


background image

 

2. Specifications 5 D Mark II 

 

Test Pressure   

10 Bar (300 ft.) Housings are individually tested 

Closure Design   

Double O-rings, Key-hole Lock 

Body Material   

6061 Aluminium 

Overall Size   

137 x 190 x 167 mm (LxWxH) / 130mm (Port only) 

Total Weight   

Approximately 2.55 Kg (Housing only) 0.90Kg (Port only) 

Buoyancy (with camera) 

Approximately neutral in salt water 

Features 

Visible main O-ring for final pre-dive check   
Double O-ring design on all controls   
Bulkhead and hot shoe plug for External 580-EX e-TTL strobe   
Standard Zoom Port18~55mm Lens 

Accessories 

5D Mark II Opening key / Lever   
Silicone O-ring grease   
Spare main O-ring   
Carrying bag   
Cleaning Kit 

Optional accessories 

Semi-Dome Port for xxxxxxx mm Lens   
580-EX e-TTL Flashlight Housing   
Flex Arm   
Ball-Joint Arm   
Synchronous Cord     

 

3. Function Controls 5 D Mark II 

1. 

Flashlight syn bulkhead

   

2. 

Flashlight syn bulkhead 

 

3. 

Mode Dial

 

4. 

Metering / White Balance

 

5. 

AF.Drive

 

6. 

ISO speedset

   

7. 

Light

 

8. 

Main Dial

   

9. 

Shutter

   

10. 

Screen Display

   

11. 

Menu

   

12. 

Picture Style

 

13. 

INFO

 

14. 

Playback

 

15. 

Erase

 

16. 

Print 

 

17. 

Viewfinder eyepiece

 

18. 

Control dial 

 

19. 

AF Mode

   

20. 

Auto Exposure

 

21. 

AF point selection 

22. 

Setting 

23. 

Turntable

 

    24. 

Power

 

On / Off 

25. 26. 27.

 

28. 

Key Hole Lock

 

 

 


background image

 

4.  Set up Instructions

   

4.1 Special note on responsibility for watertight integrity

 

Each housing is individually inspected and

 

hydrostatically tested in the factory. The design of the 

main piston O-ring seal is among the most reliable in the industry and the watertight integrity is 

excellent. This special O-ring design provides a perfect seal even if there is any movement 

between the body and lid due to change of ambient pressure.

 

However please note that 

responsibility for ensuring the integrity of the watertight seal lies

 

entirely with the user. 10BAR 

accepts no liability for damage to, or loss of any equipment used with, or placed inside the housing.

 

Users are highly recommended to carry out in-water test of the housings without installing of the 

camera for their first dive, after change of new ports or alternation of any new configuration. The 

test can be carried out by lowering the housing with ballast to the working depth or dive down to the 

safe diving range.   

 

 

The O-ring seal is the main barrier between the 

water outside and the air space within the camera. 

It is an effective barrier only if the seal is properly 

maintained. The O-ring seal should be inspected 

before every dive. The following information is 

provided for your guidance in using and 

maintaining the O-ring seal.   

 

 

4.2 Maintaining the O-ring Seal   

If the main body to lid O-rings are not installed, 

install the O-rings before diving. Their care and 

maintenance are critical to the watertight integrity 

of the housing. If the O-rings are contaminated, or 

not already installed; inspect, grease and install 

the O-rings according to the following guidelines.   

 

 

 

 

 

4.3 Inspection, cleaning and re-instillation of the O-rings   
Tools 

 

A soft cotton bud or sponge applicator, make sure these are free of all 

contamination such as loose 

fibers, and the tube of silicone grease supplied with the housing. 

Note other types of silicone grease 

specifically for use with underwater camera equipment

 

can usually also be used. It is advised to 

carry out the following procedure on a firm clean

 

level surface, e.g. at a table, to prevent skidding 

especially when diving from

 

a boat.   

 


background image

 

When to maintain the O-ring seal   

Remove the O-ring periodically for inspection. It is not necessary to remove, clean and re-install the 

O-ring after every dive provided the O-rings are not become contaminated. As a rule of thumbs set 

up the camera and housing before a day

’s diving. If the housing is required to be opened between 

dives for changing memory card or re-charging batteries, make sure the outside of the housing is 

thoroughly toweled dry before opening up. After removing the lid and servicing the camera, replace 

the lid straight away, rather than leaving it lying around. Before replacing the lid, check the o-rings 

and make sure that no contamination such as dust, hair, salt, sand etc. has fallen onto the O-ring or 

O-ring recess, as a precaution we recommend to inspect the O-ring every time the lid is opened 

and to carry out the maintenance only if necessary.   

 

Procedure   
l  Place the lid on firm non-slip level surface. 
l  The O-ring can be extracted using an O-ring extractor tool (make sure the tool has no sharp edges). 

Alternatively use the flats of the thumbs to gently stretch the O-ring on two faces thus making a small 

loop protruding a few mm. The loop can then be grasped between finger and thumb, to pull the O-ring 

over the lip.   

l  Clean the O-ring recess (the square groove 

where the O-ring sits) with a cotton bud. 

l  Inspect the O-ring all the way round its surface 

for damage such as cuts tears or contamination. 
This should be done visually and also by feeling 
the surface texture between finger and thumb.   

 
 
 
 
 

IF THE O-RING IS DAMAGED OR SUSPECTED OF BEING DAMAGED, DISCARD

 IT 

IMMEDIATELY.   

spare O-ring is supplied with your housing, or a replacement O-ring can be ordered from 10 BAR. 

If the O-ring is contaminated or suspected of being contaminated, clean it with a cotton cloth that is 
free of all chemicals or contamination. After cleaning inspect the O-ring again.   
Once the O-ring has been inspected and verified fit for use, apply a small amount of silicone grease 
to the O-ring. The silicone grease must be evenly distributed round the O-ring.   
Replace the O-ring into the groove; run a finger round the O-ring, to make sure it is snugly seated in 
the groove. 
 
 
 
 
 
 
 
 

 


background image

 

4.4 Key Hole Lock   

The Key-hole Lock is simple and easy to use and adding security. 

To open the housing, turn the levers of the lock perpendicular to the wall of the housing until the 

lock is released on both sides.   

 

 

 

 

                    Opening Key 

Pull out the lid by holding on the grip near the lock 

 

 

 

 

 

 

 

 


background image

 

4.5 Mounting the camera in the housing: 
Remove the lens cap and wrist strap.   
Attach the plastic slide tray to the camera

’s tripod mounting fixture with a screwdriver or the end of 

the universal tool supplied. Take care not to excessively tighten the 
screw. Slide the camera into the body along the guide rail. Make sure the camera body reach the 
limit and test the function of the on/of button on the body of the housing. Slide the hot shoe plug into 
the hot shoe.   

         

   

 

 
 
 
 
 
 
 
 
 
 
 
 
Note: If you find that the buttons do not align properly with the controls, please check 
again that the camera is properly seated to the limit of the guide rail. 
 
Slide the camera into the body along the rubber packing. Make sure the camera body reach the 
limit and test the function of the On/Off button on ths body of the housing. 
Align the bulkhead cable as shown and check the cable is not jammed under any button or over the 
o-ring. Slide the hot shoe plug into the hot shoe

 

           

 


background image

 

To  close  the housing, place  the lid  over  the housing  and align  the  key-hole  and  press  down  the 
lever.

 

 

 

 

 

 

 

 

 

 

 

 

Turn the lever towards the wall of the housing and check the key is at lock position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the lid and make sure the lever is perpendicular to the side wall of the housing. Lock the lid 
by press down the lever and turn until the lever is parallel to the side wall of the housing. 

After replacing and locking the lid, make a final visual inspection of the main O-ring for 

contamination.   

 

Note: If the O-ring is in good contact, a thin black line, about 0.5 to 1mm in width should be visible, 

where the O-ring is in contact with the lid. Follow this line all the way round the edge of the seal, as a 

final check that the seal is good. 

After replacing the lid, make a final visual inspection of the main O-ring for contamination 

 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

Note: If the O-ring is in good contact, a thin black line, about 0.5 to 1mm in width should be 
visible, where the O-ring is in contact with the lid. Follow this line all the way round the edge 
of the seal, as a final check that the seal is good. The housing is now ready for the dive.

 

 

4.6 Inspection, cleaning and re-instillation of the O-ring: 

 

Tools: 

   

A soft cotton bud or sponge applicator, make sure these are free of all chemicals or contamination such as loose fibers, and 

the  tube  of  silicone  grease  supplied  with  the  housing  are  required.  Note  other  types  of  silicone  grease  specifically  for  use 

with  underwater  camera  equipment  can  usually  also  be  used.  It  is  advised  to  carry  out  the  following  procedure  on  a  firm 

clean level surface, (e.g. at a table), to prevent skidding especially useful to have when diving from a boat.   

 

When to maintain the O-ring seal: 

   

Remove the O-ring periodically for inspection. It is not necessary to remove, clean and re-install the O-ring after every dive 

provided the O-ring did not become contaminated. As a rule of thumb set up the camera and housing before a day’s diving. 

If  the  housing  is  required  to  be  opened  between  dives  for  changing  memory  card  or  re-charging  batteries,  make  sure  the 

outside  of  the  housing  is  thoroughly  toweled  dry  before  opening  up.    After  removing  the  lid  and  servicing  the  camera, 

replace the lid straight away, rather than leaving it lying around. Before replacing the lid, make sure that no contamination 

such as dust,  hair, salt, sand etc.  has fallen  onto the O-ring or O-ring recess, as a precaution we recommend  to inspect the 

O-ring every time the lid is opened and to carry out the maintenance if necessary.   

 

5

. Use & Care of Housing: 

5.1 

Pre Dive Function Check. 

Just before entering the water, make a habit of reviewing the proper steps to close the housing and connect 
the 
bulkhead. Make a visual check of the O-ring seal. It is also useful to switch on the camera, and check that 
the 
controls e.g. on/off, zoom, shutter functions operate normally. 

   

Check housing is closed 

   

Check O-ring is in the groove between housing and Acrylic 

   

Check battery and memory card status on the LCD display 

   

Check control knob and zoom function 

   

Check the Bulkhead is properly connected or blanked. 

Always avoid submerging the housing in hot water for a prolonged time or a cleansing tank where the 
water may be heated up by the sun. 

 

 

 


background image

 

5.2 

General Operation. 

The control levers and push buttons consist of internal double O-ring seals on a stainless steel 
shaft. This arrangement is very reliable, however as a precaution, when operating the controls, avoid 
excessively rapid movements, as this may distort the O-ring. Also please allow for the fact that the camera 
takes a few seconds to power on. If the camera dose not appear to respond to a control action, make sure 
that no other controls are pressing on the camera, i.e. locking out further actions. Wear the wrist strap; it 
is easy to inadvertently let go of the housing, especially if you are distracted. 

 

5.3 Cleaning & Storage. 

     

The body & lid of the housing are made of polycarbonate. Polycarbonate was selected for its outstanding strength stiffness, 

hardness and toughness. As well as its crystal clear transparency and high gloss surface. It has good resistance to weathering, 

although  long-term  exposure  to  sunlight  should  be  avoided.  Normal  operating  temperature  range  is  3°C  to  36°C  (Storage 

temperature: -10°C to 50°C)     

It is good practice to rinse off your housing with fresh water after every dive. Avoid exposure to fine sand. After a series of 

10  or  more  dives,  e.g.  after  a  dive  holiday,  it  is  recommended  to  immerse  the  housing  for  2-3  hours  in  warm  water  to 

dissolve any salt deposits that  may have built up. No chemical cleaners should be  used. Mild detergents e.g. shampoo and 

soap based cleaners are permitted.   

 

Important !!! 

 

Some  household  chemicals  may  harm  Polycarbonate;  the  housing  should  never  be  exposed  to  the 
following  classes  of  chemicals:  benzene,  toluene,  xylene,  chlorinated  hydrocarbons,  methanol,  any 
other solvents, strong acids and bases. 

 

For long term storage please remove the main o-ring from body. 

     

 

5.4 Transportation.

     

When transporting by air, please ensure the housing is not sealed, to allow the air pressure to equalize. Either remove the O 

-ring (recommended), or open the pressure release port (a spacer is provided to keep the pressure plug in the open position, 

please make sure there is no bending of the plug while open).   

Please protect the housing during transportation. It is recommended to remove the sync cord, and wrap the housing in foam 

or bubble wrap.     

 

5.5 Accidents.   

   

The impact resistance  of the  housing is  excellent. However after an accident the alignment  of the  housing  may  have been 

damaged. Therefore in the event of your housing suffering an impact force, e.g. being dropped, it is essential you do not use 

the housing for diving. Please return the housing immediately for service. Please put a note inside to indicate the nature of 

the accident, so that we can assess the severity.     

 

6.  Service 

 

To ensure the continued performance of your housing, it should be serviced every year, or after every 200 dives.      Please 

note the terms for servicing the housing posted at our website. A full service will include:   

• 

Inspection of all components for wears or damage (report if repair necessary)   

• 

Cleaning of all sealing surfaces, and replacement of all O-ring seals.   

• 

Hydrostatic pressure test to 10 Bar.   

Note: the replacement of damaged components (except replacement O-rings) may require additional cost.

   

 

 

 


background image

 

10 

7. Warranty 

The warranty is valid within two years from the date of first purchase. The warranty applies only to the housing itself.   

10 BAR does not accept any liability either implicit or otherwise for any equipment housed 
inside, or used together with the housing.

 

In  the  event  of  the  housing  flooding  within  the  period  of 

warranty, 10 BAR will repair or replace the housing. Please note that disassembly of the housing will invalidate warranty. 

Please fill in the information below, and return a copy to 10 Bar Underwater Housing at the address below, to validate 

the warranty.

 

 

 

 

 

 

 

 

 

 

 

(Copy to be retained by user)

   

 

Housing Type 

 

Date of Purchase 

Serial Number : 
(Labelled 

inside 

housing) 

 

Dealer : 

Owner’s Name : 

 

E-mail : 

Owner’s 
Address: 

 

Tel    :   
 
Fax :   
 

 

Office & Showroom:     
Unit C, 2/F., Wing Hin Factory Building, 31-33 Ng Fong St.,     
San Po Kong, Hong Kong.     
Tel: (852) 2573 3228 Fax: (852) 2811 9180.       
Email: 

service@10bar.com

    Web site: 

http://www.10bar.com

 

 

     

 

Please keep this document for future reference   